Instruction Manual for CommScope models including: CS04 PGP Polymer Cable Management System, CS04, PGP Polymer Cable Management System, Cable Management System, Management System

7859822

COMMSCOPE\convsrvr (GPR1PAPEDLNT03)

PGP Series Installation Instructions

PGP-CS18 | CommScope


File Info : application/pdf, 2 Pages, 3.14MB

PDF preview unavailable. Download the PDF instead.

PGP Series Installation Instructions
Installation Instructions

PGP-CS04, PGP-CS08, PGP-CS10, PGP-CS16 and PGP-CS18

PGP Polymer Cable Management System

Bulletin 7859822

Revision C page 1 of 2

Product Parts

PGCS-1000

PGP-CS02

T shape holes

Hardware kit

The clamp is combined by two PGCS-1000 and hardware kit. Can assembled on 2-3/8" or 2-7/8" pipe with an applied torque of 15 Nm.

Wedge structure

PGCS-2000

T shape holes

PGCS-3000
3/4" holes

Wedge structure

PGCS-4000
3/4" holes

NOTE: 1. Please use the recommended torque to install
the clamp. 2. This product only use for Gen1 & Gen2 Snap-in
hangers.

Panels: For installing Snap-in cable hangers
Recommended Configurations

PGP-CS04

PGP-CS08

PGP-CS10

PGP-CS16

PGP-CS18

WARNING
Improper installation may cause structural damage or difficulty in disassembly.

Quantities of parts used in different configurations

PGP-CS02 PGCS-2000 PGCS-3000 PGCS-4000

PGP-CS04

1

X

X

2

PGP-CS08

1

X

1

1

PGP-CS10

1

1

1

1

PGP-CS16

1

2

2

X

PGP-CS18

1

1

2

2

NOTE: 1. Can only be applied to jump cable. 2. Stack up to two hangers in each 3/4" hole. 3. Can not use the two holes near the clamp on the inside of the panel. (PGP-CS08 and PGP-CS18)

CommScope 3642 E US Highway 70, Claremont, NC 28610 USA (828) 324-2200 (800) 982-1708 www.commscope.com

Customer Service 24 hours North America: +1-800-255-1479 (toll free) Any country: +1-779-435-6500 email: acicustomersupportcenter@commscope.com

Notice: CommScope disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices. Aviso: CommScope no acepta ninguna obligación ni responsabilidad como resultado de prácticas incorrectas o peligrosas de instalación, inspección, mantenimiento o retiro. Avis : CommScope décline toute responsabilité pour les conséquences de procédures d'installation, d'inspection, d'entretien ou de retrait incorrectes ou dangereuses. Hinweis: CommScope lehnt jede Haftung oder Verantwortung für Schäden ab, die aufgrund unsachgemäßer Installation, Überprüfung, Wartung oder Demontage auftreten. Atenção: A CommScope abdica do direito de toda responsabilidade pelos resultados de práticas inadequadas e sem segurança de instalação, inspeção, manutenção ou remoção. Avvertenza: CommScope declina eventuali responsabilità derivanti dell'esecuzione di procedure di installazione, ispezione, manutenzione e smontaggio improprie o poco sicure.

© May, 2020 CommScope

Installation Instructions

PGP-CS04, PGP-CS08, PGP-CS10, PGP-CS16 and PGP-CS18

PGP Polymer Cable Management System

Bulletin 7859822

Revision C page 2 of 2

First install the components on both sides of the Clamp, then install the two assembled clamps to the 2-3/8" or 2-7/8" pipe with bolts.

A

B

Tongue Lug

Lug Tongue

D

E

C

Installation of Clamp: Fix clamp to the pipe, then insert the tongues on both sides

of the clamp into the corresponding lugs.

C+C is combined into PGP-CS04. C+D is combined into PGP-CS08. B+C is combined into PGP-CS10. B+B is combined into PGP-CS16. A+E is combined into PGP-CS18.
NOTE: When clamp (PGCS-1000) and long panel (PGCS-3000) are directly installed, two bolts need to be pre-inserted into the mounting holes. (D and E in the picture above)

Disassembly of Clamp: Hold the tongues on both sides of the clamp. Use both hands to pull the clamp halves apart by removing the tongue from the lug.
WARNING
Do not tighten the clamp to the pipe with bolts alone to prevent it from deforming and causing other components to fail to be installed.

Installation of wedge structure: Fully insert the wedge structure into the T shape holes, slide the wedge structure down, after hear a "click" to indicate that the installation is complete.

Disassembly of wedge structure:
PGCS-1000 Tooling PGCS-2000

Use tooling as shown in the figure to push back the beam, then tilt up PGCS-2000 so that the beam snaps onto the mounting surface. And follow the same method to push out the other beam.

Hold the PGCS-1000, push out the PGCS-2000 as shown in the figure, and then pull it out to complete the disassembly.
Push

CommScope 3642 E US Highway 70, Claremont, NC 28610 USA (828) 324-2200 (800) 982-1708 www.commscope.com

Customer Service 24 hours North America: +1-800-255-1479 (toll free) Any country: +1-779-435-6500 email: acicustomersupportcenter@commscope.com

Notice: CommScope disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices. Aviso: CommScope no acepta ninguna obligación ni responsabilidad como resultado de prácticas incorrectas o peligrosas de instalación, inspección, mantenimiento o retiro. Avis : CommScope décline toute responsabilité pour les conséquences de procédures d'installation, d'inspection, d'entretien ou de retrait incorrectes ou dangereuses. Hinweis: CommScope lehnt jede Haftung oder Verantwortung für Schäden ab, die aufgrund unsachgemäßer Installation, Überprüfung, Wartung oder Demontage auftreten. Atenção: A CommScope abdica do direito de toda responsabilidade pelos resultados de práticas inadequadas e sem segurança de instalação, inspeção, manutenção ou remoção. Avvertenza: CommScope declina eventuali responsabilità derivanti dell'esecuzione di procedure di installazione, ispezione, manutenzione e smontaggio improprie o poco sicure.

© May, 2020 CommScope



References

CIDEON PdfEditor (x64) V 3.7.208.0