Instruction Manual for Q-TRAN models including: QUOVA-STANDARD Linear Fixture, QUOVA-STANDARD, Linear Fixture, Fixture

QUOVA-STANDARD Applications/Install

QUOVA-STANDARD | Knife Edge | Q-Tran


File Info : application/pdf, 7 Pages, 2.66MB

PDF preview unavailable. Download the PDF instead.

INSTALL-QUOVA-STND ?d=104202332626
INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD

QUOVA-STANDARD

COMPLIANT

5YEAR WARRANTY

© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com Specification subject to change. Rev-09-29-23

1

METHODS & INSTALLATIONS

COMPONENTS & HARDWARE

MAIN HOUSING MOUNT

INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD
ATTENTION: Please read all instructions BEFORE installation
· Product to be installed by a licensed electrician - Field modifications void warranty · Use only with Class 2 power supply unit -- Compatible for use with Q-Tran power supplies · Knife edge cove mount · Input Voltage: 24VDC · Diagrams for representation only and not to scale.

METHODS OF INSTALLATION

Compatible Fixtures

THIN

WIDE

ROND

TORQ

LALO

ARKA

TELA

VEVE

OPTI

VERS

CEILING

Quova-Standard
3.20"

MOUNTING METHOD · MAIN HOUSING MOUNT: page 4-5 · FIXTURES MOUNT: page 6 · DUST COVER(optional): page 7

FLOOR

WALL WALL 1.06" 1.88"

FIXTURES MOUNT

DUST COVER

© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com Specification subject to change. Rev-09-29-23

2

INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD

METHODS & INSTALLATIONS

1.06" 1.88"
.21"
1.06" 1.12" 1.88"

COMPONENTS & HARDWARE

MAIN HOUSING MOUNT

FIXTURES MOUNT

3.20" QUOVA-STANDARD

.80" 3.20"
Profile with OPTI and Frosted Optional Dust Cover

COMPONENTS & HARDWARE

STAINLESS STEEL CLIP

1.25"

.81" .20"

SST-01

.18" .7"

1.25"

CC-01

Included
.188"
Stainless Steel Phillip #4-40 - X 3/16"

MAGNET CLIP

1.25"

.81" .20"

.20"

MG-01

.15" 3.13" .35" MG-02

MAGNET MOUNT ACCESSORY (sold individually)

.23" .75"

.64" 2.5"
12"
MMA-01

Included
· 2#6x5/8" Flat Head SS

.64" .58"

1.86" 12"
MMA-02

Included
· 2#6x5/8" Flat Head SS

DUST COVER

11.6.6""

Outside

Inside
CORNER 1
2 3 A B 4 5 6

A - Fixture Housing B - Lighting Module
1 - Inside and Outside Corners. 2 - Fixture Mounting Channel. 3 - Mounting Screws, by Others. 4 - Fixture Housing Extrusion - Anodized Aluminum - surface
treated to accept paint. Provided in 8ft nominal lengths. Field cut final piece in linear run to desired length. 5 - End Cap - Used to close the end of the fixture housing extrusion. Not required when the fixture housing extrusion ends in a corner or against a wall. Available in Left and Right Configurations. 6 - Inline Bracket; Designed to align and hold sections of fixture housing together.

..1166" " QV-STND-FR Frosted Dust Cover (optional)
STAINLESS STEEL CLIP · 2 clips provided for 4' or less; 4 clips provided for greater than 4'

NOTES: MAGNET CLIP
· One magnet clip per foot · MMA-01/MMA-02 comes in 12" pieces; use at least one clip per MMA accessory · MMA-01/MMA-02 can be cut into smaller pieces, if desired

© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com Specification subject to change. Rev-09-29-23

3

DUST COVER

METHODS & INSTALLATIONS

COMPONENTS & HARDWARE

INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD

MOUNTING METHOD: MAIN HOUSING MOUNT

1

2

16"

16" Corner

a: Pre-drill 1/4" pilot holes every 16" to align with studs start with corners and fill in with straight sections..
b: Align QUOVA to be level, and if necessary, to line up with ceiling/soffit.
c: Mount QUOVA to wall with #6 screws (by others) every 16" into studs.

a: Determine wire feed location. b: Drill 1/4" Hole through QUOVA and drywall.

MAIN HOUSING MOUNT

FIXTURES MOUNT

DUST COVER

3
Corner
a: If multiple lengths are being used, install the inline bracket. b: Install inline bracket in mounted piece. c: Follow Instructions of step 1 for second length. d: Confirm both pieces are level and aligned, mount second piece, slide inline bracket over and tighten set screws. e: Repeat for additional lengths as needed.

ISO View
4

Front View

a LEFT

ISO View

RIGHT b
Front View
Install the endcap on the appropriate side and tighten set screw and repeat on the other side.

© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com Specification subject to change. Rev-09-29-23

4

METHODS & INSTALLATIONS

COMPONENTS & HARDWARE

INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD

MOUNTING METHOD: MAIN HOUSING MOUNT

5

6

View Bottom

ISO-Top View

Dry wall Tape
Apply drywall tape at joint of QUOVA to wall and underneath.

Joint Compound
a: Apply joint compound to wall and underneath. b: Allow to dry. c: Sand and repeat as necessary. d: Once completed, apply primer and paint.

MAIN HOUSING MOUNT

FIXTURES MOUNT

DUST COVER

© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com Specification subject to change. Rev-09-29-23

5

METHODS & INSTALLATIONS

INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD

MOUNTING METHOD: FIXTURES MOUNT

1

2

b
With MMA installed

With MMA installed

a

b

With Mounting Clip installed

a: Install mounting clips in screw track.
a&b: Mount Lighting fixture inside of QUOVA. Run wire through pre-drilled hole back to power supply or junction box.

QUOVA Standard Install Assembly.

With Mounting Clip installed

COMPONENTS & HARDWARE

MAIN HOUSING MOUNT

FIXTURES MOUNT

DUST COVER

© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com Specification subject to change. Rev-09-29-23

6

METHODS & INSTALLATIONS

COMPONENTS & HARDWARE

INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD

MOUNTING METHOD: DUST COVER OPTION

a

11

2

CEILING

b

Install the dust cover.
a. Connect the dust cover to the front lip of housing and rotate it into place. Run finger along seam to lock dust cover into place.
b. Peel dust cover tape .

ISO VIEW
Assembled fixture.

SIDE VIEW

MAIN HOUSING MOUNT

FIXTURES MOUNT

DUST COVER

© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com Specification subject to change. Rev-09-29-23

7



References

Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)