Mitsubishi Electric FR-D740-012SC-EC Inverter - Material Fact Sheet
General Data
Product Hierarchy | IAK23801 |
Ext. Material Group | INVERTER |
ABC Indicator | A (Available from Stock) |
e-shop | https://mitsubishi-electric-eshop.mee.com/mee/FA_IA/EUR/en/p/000000000000312334 |
FA-Inverter: Inverter
Series | FR-D700 SERIES |
Type | FR-D700 COMPACT INVERTER |
Minimum Rated Voltage (V) | 380 |
Min. Permissible Voltage (V) | 325 |
Maximum Rated Voltage (V) | 480 |
Max. Permissible Voltage (V) | 528 |
Current Type | AC |
Phases | 3 |
Rated Output Current ND (A) | 1,2 |
Rated Motor Capacity ND (kW) | 0,4 |
Frequency Range (Hz) | 0,2-400 |
Control Method | MAGNETIC FLUX VECTOR CONTROL |
Control Method (2) | SOFT-PWM/HIGH FREQUENCY PWM |
Control Method (3) | V/F CONTROL |
Motor Type | INDUCTION MOTOR |
Brake Chopper ED (%) | 30 |
Integrated EMC Filter | NO |
Safe Torque Off (STO) | YES |
Regenerative (4Q) | NO |
Integrated DC Choke | NO |
Display | BUILT-IN |
Display Type | 4 DIGITS LED |
PLC Function | NO |
Integrated Digital Inputs | 5 |
Digital Outputs (Transistor) | 1 |
Digital Outputs (Relay) | 1 |
Integrated Analogue Inputs | 2 |
Integrated Analogue Outputs | 1 |
IO Type of Terminal Block | SPRING CLAMP |
Expandable | NO |
RS-485 | 1 |
USB | NO |
Ethernet Port | NO |
Built-In Network | MODBUS-RTU |
Leakage Current (mA) | 1 |
Power Loss ND (W) | 40 |
Standby Power Consumption (W) | 10,5-15 |
Protection Class | IP20 |
Product Dimensions & Weight
Width (mm) | 108 |
Height (mm) | 128 |
Depth (mm) | 129,5 |
Weight (kg) | 1,2 |
Logistic Dimensions & Gross Weight
Length (cm) | 19,0 |
Width (cm) | 17,5 |
Height (cm) | 22,0 |
Gross Weight (kg) | 1,580 |
Volume (cdm) | 7,315 |
Stock Data
Planned Delivery Time (Days) | 103 |
Life Cycle
Sales Start | 05.03.2012 |
Predecessor | 212414/FR-D740-012-EC |
Additional Product Information
Binding Tariff Information | DEBTI-14477/24-1 |
BTI validity date | 07.07.2027 |
Battery included | NO |
Export Data
Commodity Code | 85044095 |
Legal Control (Dual Use List) | Not Listed |
Country of Origin | China (CN) |
Preference Status (Supplier Declaration) | Non EU |
Environmental
Dangerous Goods Class | NO |
Dangerous Goods Identifier | NO |
RoHS Compliance | COMPLIANT |
WEEE | B2B |
Conformity
CE | COMPLIANT |
UL/cUL | COMPLIANT |
EAC | COMPLIANT |
UKCA | COMPLIANT |
Documentation & Media Data
Product Packaging
Cardboard (g) | 330,5 |
Other paper (g) | 0 |
Aluminum (g) | 0 |
Steel (g) | 0 |
Styrofoam (g) | 0 |
Other plastic (g) | 2,2 |
Wood (g) | 0 |
Glass (g) | 0 |
Others (g) | 0 |
Compatible products
Material | Description / Price List Text / Classification |
---|---|
70727 | FR-ABR-H0.4K External High-Duty Brake Resistor; 400V; 0,4kW; 1200 Ohm; 10%ED Class 100100407: FA-Inverter: Brake Option |
70728 | FR-A CBL 1 Cable for connecting Inverter and Programming panel; 1m Class 100100405: FA-Inverter: Cable |
70729 | FR-A CBL 3 Cable for connecting Inverter and Programming panel; 3m Class 100100405: FA-Inverter: Cable |
70730 | FR-A CBL 5 Cable for connecting Inverter and Programming panel; 5m Class 100100405: FA-Inverter: Cable |
88426 | SC-FR-PC CONNECTION CABLE PC>INVERTER Programming Cable RS 232>RS485/422; 5m Class 100100405: FA-Inverter: Cable |
127947 | BU-UFS 22 Brake Unit 400V; Contin. Braking Current 22A; 10sec peak current 34A Class 100100407: FA-Inverter: Brake Option |
129629 | RUFC22 (PACK OF 1) Brake Resistor for BU-UFS22; 2kW; 1x24 Ohm Class 100100407: FA-Inverter: Brake Option |
130832 | FR-UDA02 DIN-Rail Adaptor for FR-D720S-1,5k; FR-D740-0,4k-3,7k Class 100100403: FA-Inverter: External Option |
134971 | FR-BAL-B-0,4K Input Reactor 3ph; 400V; for 0,4kW Class 100100406: FA-Inverter: Choke |
157514 | FR-DU07 Parameter Unit for inverter type FR-A700-NA Class 100100403: FA-Inverter: External Option |
157515 | FR-ADP Adaptor Module for Operator Panel FR-DU07 Class 100100403: FA-Inverter: External Option |
166134 | FR-PU07 Programming panel with LCD-Display for all units of FR-700 series Class 100100403: FA-Inverter: External Option |
209052 | FR-PU07BB-L Programming Panel with Copy Function; batterypowered; all FR-700 units; w/o bat. Class 100100403: FA-Inverter: External Option |
209735 | FFR-SI-4.5A-SS1 Sinusfilter for 200/230/400V Inverters; max. 4,5A;FT=4-16kHz; (W*H*D) 125*180*75mm Class 100100404: FA-Inverter: Filter |
209755 | FFR-DT-10A-SS1 du/dt Filter for 400V Inverters; max. 10A; FT=2-16kHz; (W*H*D) 100*120*65mm Class 100100404: FA-Inverter: Filter |
214795 | FR-PA07 Simple Parameter Unit for mounting on enclosure surface; for all FR-E700 Class 100100403: FA-Inverter: External Option |
238342 | FFR-HEL-H0.4K-E DC Link choke for 400V Inverter; 0,4kW; 88mH; 0,9A Class 100100406: FA-Inverter: Choke |
247638 | BH-D6 3P 6A TYPE C N MCB 3-poles, Rated current 6A, Operating characteristic C Class 100100801: FA-MCB: Miniature Circuit Breaker |
254683 | NF32-SV 3P 6A Circuit breaker 3pole. In = 6A; Icu = Ics = 2,5kA at AC 440V Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker |
275503 | FR Configurator-M+FR-Configurator2 FR-Configurator for 700 series; multi I + FR-Configurator2 for 800 series Class 100101203: FA-Software: Software Inverter |
279143 | S-T10 AC200V 1A Magnetic contactor. 4kW; 1NO; Us = AC 200V, 50Hz Class 100101001: FA-MC: Magnetic Contactor |
287431 | SD-T12 DC24V 1A1B Magnetic contactor. 5,5kW; 1NO + 1NC; Us = DC 24V Class 100101001: FA-MC: Magnetic Contactor |
312332 | FFR-CSH-036-8A-SF1 Radio Noise Filter for E840-016/026/040; C1 20m, C2 100m Class 100100404: FA-Inverter: Filter |
312334 | FFR-CSH-036-8A-SF1-LL Radio Noise Filter for E840-016/026/040; C1 10m, C2 30m Class 100100404: FA-Inverter: Filter |