Instruction Manual for GREISINGER models including: RT420-SG, GTP-SG, GTP-SG Temperature Transducer, Temperature Transducer, Transducer

GREISINGER RT420-SG (01) PDF MANUAL - Manual-Hub.com

PDF preview unavailable. Download the PDF instead.

GREISINGER RT420-SG (01)
T07.S.0Y.6C-03

Temperature Transducer (click housing)

Operating Manual

GTP -SG GNTP -SG RT420 - SG

WEEE-Reg.-Nr. DE93889386
GREISINGER electronic GmbH
D - 93128 Regenstauf, Hans-Sachs-Straße 26
 +49 (0) 9402 / 9383-0  +49 (0) 9402 / 9383-33  info@greisinger.de
https://manual-hub.com/

T07.S.0Y.6C-03

Operating Manual GTP ­SG, GNTP -SG

page 2 of 4

General
The transducer is ready to use und especially designed for top hat rail mounting.
1 Safety instructions
This device has been designed and tested in accordance to the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using it. 1. Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected to any other
climatic conditions than those stated under "Specification". Transporting the device from a cold to a warm environment condensation may result in a failure of the function. In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up. 2. General instructions and safety regulations for electric, light and heavy current plants, including domestic safety regulations (e.g. VDE), have to be observed. 3. If device is to be connected to other devices (e.g. via PC) the circuitry has to be designed most carefully. Internal connection in third party devices (e.g. connection GND and earth) may result in not-permissible voltages impairing or destroying the device or another device connected. 4. Whenever there may be a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may be a risk if: - there is visible damage to the device - the device is not working as specified - the device has been stored under unsuitable conditions for a longer time In case of doubt, please return device to manufacturer for repair or maintenance. 5. Warning: Do not use this product as safety or emergency stop device or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage.

2 Housing

78

12

12

95 105

https://manual-hub.com/

T07.S.0Y.6C-03
3 Assignment

Operating Manual GTP ­SG, GNTP -SG

Voltage

Current

page 3 of 4

2 wire connection

3 wire connection

4 wire connection

Thermocouple element

4 Disposal instructions
This device must not be disposed as "residual waste". To dispose this device, please send it directly to us (adequately stamped). We will dispose it appropriately and environmentally friendly.
https://manual-hub.com/

T07.S.0Y.6C-03
5 Specification

Operating Manual GTP ­SG, GNTP -SG

page 4 of 4

Sensor element:

Pt100, NiCr-Ni

Pt100 (RT 420), RT420

Measuring range:

please refer to type plate

please refer to type plate

Output signal:

please refer to type plate

4-20mA

Accuracy electronic: (at nominal temperature)
Temperature coefficient:

< ±0.2% FS (Full Scale) Pt100 < ±0,2% FS (Full Scale) ±0,5°C NiCr-Ni
0.05 % / °C

range < 250°C: < ±0.25°C range > 250°C: < ±0.1% FS (Full Scale)
0.01 % / °C

Auxiliary energy: (supply voltage)
Permissible impedance: (current output)
Permissible load: (voltage output)
Reverse voltage protection:

12 ... 30V DC 18 ... 30V DC (0-10V output) 4-20mA: < ( (Uv-12V) / 0.02) Ohm 0-20mA: < 150 Ohm >3000 Ohm
max. 50V dauernd

8 ... 35V DC < ((Uv - 8V) / 23)*1000 Ohm
max. 35V

Nominal temperature:

+25 °C

+23 °C ± 2°C

Operating temperature:

0 ... +70 °C

-20 ... +70 °C

Storage temperature:

-20 ... +70 °C

-20 ... +70 °C

Relative humidity:

0 .. 95 % r.H. non condensing

0 .. 95 % r.H. non condensing

Dimensions / housing:

approx. 22.5 x 78 x105 (H x W x D), for top hat rail mounting

Connecting terminals:

For cable with max. 1.5mm² cross section

EMC:

The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG). In accordance with EN 61326 (appendix B, class B), performance criterion D

https://manual-hub.com/