User Guide for Milesight models including: WS513 Smart Wall Socket, WS513, Smart Wall Socket, Wall Socket, Socket

WS51x Smart Wall Socket User Guide-V1.0

Milesight WS513 - Airteq


File Info : application/pdf, 22 Pages, 2.38MB

PDF preview unavailable. Download the PDF instead.

WS51x-Smart-Wall-Socket-User-Guide-V1.0
Smart Wall Socket
Featuring LoRaWAN®
WS51x
User Guide

Safety Precautions
Milesight will not shoulder responsibility for any losses or damages resulting from not following the instructions of this operating guide.  The device must not be modified in any way.  In order to protect the security of the device, please change the device password when first
configuration. The default password is 123456.  The device is intended for indoor use only. Do not place the device where the temperature is
below/above the operating range.  Do not overload the maximum capacity to avoid damaging the device.  Do not place the device close to naked flames, heat sources (such as oven or sunlight), cold
sources, liquid, and objects with extreme temperature changes.  Use the device in a clean environment only. Dusty or dirty environments may prevent the
proper operation of this device.  The device must never be subjected to physical shocks or strong vibration.
Declaration of Conformity
WS51x is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.
Copyright © 2011-2023 Milesight. All rights reserved. All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means without written authorization from Xiamen Milesight IoT Co., Ltd.
For assistance, please contact Milesight technical support: Email: iot.support@milesight.com Support Portal: support.milesight-iot.com Tel: 86-592-5085280 Fax: 86-592-5023065 Address: Building C09, Software Park III,
Xiamen 361024, China
2

Revision History
Date July 15, 2023

Doc Version Description

V 1.0

Initial version

3

Contents
1. Product Introduction ......................................................................................................................... 5 1.1 Overview ...................................................................................................................................5 1.2 Features ................................................................................................................................... 5
2. Hardware Introduction ...................................................................................................................... 5 2.1 Packing List ..............................................................................................................................5 2.2 Hardware Overview ................................................................................................................. 6 2.3 Power Button and LED Patterns ............................................................................................. 6 2.4 Dimensions (mm) .................................................................................................................... 6
3. Installation ......................................................................................................................................... 7 4. Operation Guide .................................................................................................................................8
4.1 NFC Configuration ................................................................................................................... 8 4.2 LoRaWAN Settings .................................................................................................................. 9
4.2.1 Basic Settings ............................................................................................................... 9 4.2.2 Frequency Settings .....................................................................................................10 4.2.3 Multicast Settings .......................................................................................................12 4.3 General Settings .................................................................................................................... 14 4.4 Milesight D2D Settings ..........................................................................................................15 4.5 Maintenance .......................................................................................................................... 15 4.5.1 Upgrade ....................................................................................................................... 15 4.5.2 Backup .........................................................................................................................16 4.5.3 Reset to Factory Default .............................................................................................17 5. Device Payload ................................................................................................................................ 17 5.1 Basic Information .................................................................................................................. 18 5.2 Sensor Data ........................................................................................................................... 19 5.3 Downlink Commands ............................................................................................................ 19
4

1. Product Introduction 1.1 Overview
WS51x is an in-wall smart socket panel with a stylish and minimalist design that combines power control and electricity consumption statistics features. It can intelligently manage appliances and promote the scientific use of electricity. The product offers various power control methods, such as local button control and remote control through wireless LoRaWAN® network communication. WS51x is compatible with Milesight's LoRaWAN® gateway and IoT Cloud solution, which allows for remote monitoring and control via a webpage or mobile App, triggered by other Milesight sensors. Designed for in-wall installation, WS51x has broad applications in smart homes, smart offices, smart campuses, and other scenarios.
1.2 Features
 Turn on/off devices and create delay switch-on/off schedules remotely  Collect current, voltage, power, electrical consumption and support overload protection  Elaborate structural and safety door design for both safe usage and convenient installation  Easy configuration via NFC  Function well with standard LoRaWAN® gateways and network servers  Standard LoRaWAN® technology  Compatible with Milesight IoT Cloud  Support Milesight D2D protocol to enable ultra-low latency control without gateway  Support multicast for control in bulk
2. Hardware Introduction 2.1 Packing List

1 × WS51x Wall Socket

2 × Mounting Screws 1 x Quick Start Guide 1 x Warranty Card

If any of the above items is missing or damaged, please contact your sales representative.

5

2.2 Hardware Overview

Note: Product appearance will differ according to socket types.

2.3 Power Button and LED Patterns

Function

Action

LED Indicator

Open the socket to supply power
Close the socket to supply power

Press the power button.

Off  On On  Off

Network Status

Send join network requests. Join the network successfully.

Blinks once Blinks twice

Reset to Factory Default

Press and hold the power button for more than 10s.

Quickly blinks

Note:

1) Network status will only display when LED is enabled and on.

2) If WS51x still fails to join the network after 32 join requests, the LED will stop blinking.

3) Reset operation is not affected even if the button lock is enabled or the LED indicator is

disabled.

2.4 Dimensions (mm)
EU Type:

FR Type:
6

3. Installation
Installation Note
 The installation and maintenance must be conducted by a qualified service person and should strictly comply with the electrical safety regulations of the local region.
 In order to realize the best data transmission, ensure the device is within the signal range of the LoRaWAN® gateway and keep it away from metal objects and obstacles.
 Ensure the breaker is powered off during the installation.  Do not dig the screw holes on the enclosure of this device, otherwise it will break this
device.  The nominal cross-sectional area of electrical wires should be not more than 2.5 mm2,
otherwise the wires will be easy to drop from the device.  It is suggested to mount the socket with default mounting screws. If using other screws,
ensure the width of screw head is not more than 9mm, otherwise it will break the device.  Ensure the width of socket box is more than 40mm.  Do not leave any object inside the socket box during installation.
Installation Steps
1. Ensure the circuit has been turned off and the old socket has been removed. 2. Open the face plate of WS51x wall socket. 3. Loose the screws next to the holes and connect corresponding wires to the WS51x socket.
7

4. Fix the socket to the socket box with mounting screws, then attach the face plate back onto the socket.
4. Operation Guide 4.1 NFC Configuration
WS51x can be configured via an NFC supported mobile phone. 1. Download and install "Milesight ToolBox" App from Google Play or Apple App Store. 2. Enable NFC on the smartphone and open Milesight ToolBox. 3. Attach the smartphone to the NFC area of the socket, click NFC Read to read device information.
4. Basic information and settings of WS51x socket will be shown on the ToolBox if it's recognized successfully. You can read and configure the device by tapping the Read/Write button on the App. In order to protect the security of devices, password validation is required when first configuration. The default password is 123456.
8

Note: 1) Ensure where is the NFC area on your smartphone, and it's recommended to take off the phone case. 2) If the smartphone fails to read/write configurations via NFC, keep the phone away and back to try again. 3) WS51x can also be configured by ToolBox software via a dedicated NFC reader provided by Milesight IoT.
4.2 LoRaWAN Settings
LoRaWAN settings are used to configure the data transmission parameters in the LoRaWAN® network.
4.2.1 Basic Settings
WS51x supports basic configurations like join type, App EUI, App Key and other information. You can also keep all settings unchanged by default.

Parameters Device EUI
App EUI Application Port
Join Type Application Key

Description Unique ID of the device which can also be found on the label. The default App EUI is 24E124C0002A0001. The port used for sending and receiving data, the default port is 85. OTAA and ABP modes are both available. The default Appkey for OTAA mode is

9

5572404C696E6B4C6F52613230313823.

Device Address The default DevAddr for ABP mode is the 5th to 12th digits of SN.

Network Session The default Nwkskey for ABP mode is

Key

5572404C696E6B4C6F52613230313823.

Application

The default Appskey for ABP mode is

Session Key

5572404C696E6B4C6F52613230313823.

LoRaWAN Version V1.0.2 and V1.0.3 are available.

Work Mode

It's fixed as Class C.

RX2 Data Rate RX2 data rate to receive downlinks or Milesight D2D commands.

RX2 Frequency RX2 frequency to receive downlinks or Milesight D2D commands. Unit: Hz

If the device does not receive ACK packet from network server, it will resend Confirmed Mode
data once.

Reporting interval  35 mins: the device will send a specific number of

LinkCheckReq MAC packets to the network server every reporting interval or

2*reporting interval to validate connectivity; If there is no response, the device

Rejoin Mode

will re-join the network. Reporting interval > 35 mins: the device will send a specific number of

LinkCheckReq MAC packets to the network server every reporting interval to

validate connectivity; If there is no response, the device will re-join the

network. Only OTAA mode supports rejoin mode.

Set the number of When rejoin mode is enabled, set the number of LinkCheckReq packets sent.

packets sent Note: the actual sending number is Set the number of packets sent + 1.

ADR Mode

Allow the network server to adjust the data transmission rate of the device.

Spread Factor If ADR is disabled, the device will send data via this spread factor.

Tx Power

Transmit power of the device.

Note:

1) Please contact sales representative for device EUI list if there are many units.

2) Please contact sales representative if you need random App keys before purchase.

3) Select OTAA mode if you use Milesight IoT Cloud to manage devices.

4.2.2 Frequency Settings
Select supported frequency and channels to send uplinks. Make sure the channels match the LoRaWAN® gateway. Note: When Single-Channel Mode is enabled, only one channel can be selected to send uplinks and the ADR will not work. Please enable Single-Channel Mode if you connect the device to

10

DS7610.
If device frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box, making them separated by commas. Examples: 1, 40: Enabling Channel 1 and Channel 40 1-40: Enabling Channel 1 to Channel 40 1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60 All: Enabling all channels Null: Indicates that all channels are disabled
11

4.2.3 Multicast Settings
WS51x supports setting up several multicast groups to receive multicast commands from the network server, then users can use this feature to control devices in bulks. 1. Enable Multicast Group feature on the device, and set a unique multicast address and keys to distinguish other groups. You can also keep these settings by default.

Parameters

Description

Multicast Address Unique 8-digit address to distinguish different multicast groups.

32-digit key. Default values:

Multicast McNetSkey

Multicast Group 1: 5572404C696E6B4C6F52613230313823 Multicast Group 2: 5572404C696E6B4C6F52613230313824 Multicast Group 3: 5572404C696E6B4C6F52613230313825

Multicast Group 4: 5572404C696E6B4C6F52613230313826

32-digit key. Default values:

Multicast McAppSkey

Multicast Group 1: 5572404C696E6B4C6F52613230313823 Multicast Group 2: 5572404C696E6B4C6F52613230313824 Multicast Group 3: 5572404C696E6B4C6F52613230313825

Multicast Group 4: 5572404C696E6B4C6F52613230313826

2. Add a multicast group on the network server. Take Milesight UG6x gateway as example, go to Network Server > Multicast Groups, click Add to add a multicast group.

12

Fill in the multicast group information the same as WS51x settings, and select the devices which you need to control, then click Save.
3. Go to Network Server > Packets, select the multicast group and fill in the downlink command, click Send. The network server will broadcast the command to devices that belong to this multicast group. Note: ensure all devices' application ports are the same.
13

4.3 General Settings

Parameters Reporting Interval
LED Indicator
Power Consumption When Power is Restored Button Lock
Overcurrent Alarm Overcurrent Protection
Change Password

Description The interval of reporting socket status and electrical parameters. Default: 20 mins, Range: 1 - 1080 mins Enable or disable the light indicating in chapter 2.4. This will not affect the blinks when you hold on the button to reset the device. Record the power consumption. If disabled, the device will stop recording and the power consumption value will stop updating. If the device is powered off and restored, the device will switch on or off according to this parameter. If enabled, the power button will not be allowed to turn on/off the socket. When current reaches the threshold, the device will send socket status and device electrical parameters. When current reaches the threshold, the device will stop supplying power. Change the password for ToolBox App to write this device.

Note: even overcurrent alarm or overcurrent protection is disabled, the device will also stop supplying power when the current is over rated current by 30%, then send out an alarm packet.

14

4.4 Milesight D2D Settings
Milesight D2D protocol is developed by Milesight and used for connection among Milesight devices without gateway. When D2D setting is enabled, WS51x can work as the Milesight D2D agent device to receive commands from Milesight D2D controller devices or work as Milesight D2D controller device to send commands to trigger D2D agent devices. 1. Ensure the RX2 datarate and RX2 frequency in LoRaWAN settings are the same as the D2D controller device. 2. Enable D2D Agent Settings, and define a unique D2D key to be the same as the setting in D2D controller device. (Default D2D Key: 5572404C696E6B4C6F52613230313823) 3. Define a 2-byte hexadecimal control command (0x0000 to 0xffff) and command action. For example, you can configure a control command 1510 to turn on, turn off or reverse the button as below. WS51x supports 16 control commands at most.
4.5 Maintenance
4.5.1 Upgrade
1. Download firmware from Milesight official website to your smartphone. 2. Open ToolBox App and click Browse to import firmware and upgrade the device. Note: 1) Operation on ToolBox is not supported during the upgrade. 2) Only Android version ToolBox supports the upgrade feature.
15

4.5.2 Backup
WS51x supports configuration backup for easy and quick device configuration in bulk. Backup is allowed only for devices with the same model and LoRaWAN® frequency band. 1. Go to Template page on the App and save current settings as a template. You can also edit the template file. 2. Select one template file that saved in the smartphone and click Write, then attach it to another device to write configuration.
Note: Slide the template item to the left to edit or delete it. Click the template to edit the configurations.
16

4.5.3 Reset to Factory Default
Please select one of the following methods to reset the device: Via Hardware: Hold on power button for more than 10s until LED indicator blinks. Via ToolBox App: Go to Device > Maintenance to tap Reset, then attach smartphone with NFC area to the device to complete the reset.
5. Device Payload
All data are based on the following format (HEX), the Data field should follow little -endian: 17

Channel1 Type1 Data1 Channel2 Type2 Data2 Channel 3 ...

1 Byte 1 Byte N Bytes 1 Byte 1 Byte M Bytes 1 Byte

...

For decoder examples you can find at https://github.com/Milesight-IoT/SensorDecoders.

5.1 Basic Information

WS51x reports basic information of the device whenever it joins the network.

Channel

Type

Description

01(Protocol Version)

11=>V1.1

09 (Hardware Version)

01 40 => V1.4

0a (Software Version)

01 14 => V1.14

0b (Power On)

Device is on

16 (Serial Number)

Serial number of this device, 16 digits

ff 24 (Overcurrent Alarm)

Byte 1: 00-disabled, 01-enabled Byte 2: current threshold

25 (Button Lock)

00 00-disabled, 00 80-enabled

26 (Power Consumption) 00-disabled, 01-enabled

Byte 1: 00-disabled, 01-enabled 30 (Overcurrent Protection)
Byte 2: current threshold

Example:

ff0bff ff0101 ff166762d21130962038 ff090100 ff0a0108 ff240000 ff30010a ff250000

ff2601

Channel

Type

Value

Channel

Type

Value

0b

01

ff

ff (Reserved)

ff

01(V1.0)

(Power On)

(Protocol Version)

Channel

Type

Value

Channel

Type

Value

16 (Serial 6762d21130

ff

Number)

962038

ff

09 (Hardware Version)

0100 (V1.0)

Channel

Type

Value

Channel

Type

Value

0a

0108

ff

(Software

(V1.8)

Version)

24(Overcurrent 00=disable

ff

Alarm)

00=0A

Channel

Type

Value

Channel

Type

Value

30

01=enable

00

ff

(Overcurrent

ff

25 (Button Lock)

0a=10A

00=disable

Protection)

Channel

Type

Value

18

26 (Power

ff

01=enable

Consumption)

5.2 Sensor Data

WS51x reports socket status and electrical data according to reporting interval (20 mins by

default). Besides, when the socket status changes, the device will upload the status immediately.

Channel

Type

Description

UINT16, Unit: V

03

74 (Voltage)

Resolution: 0.1 V

04

80 (Active Power)

UINT32, Unit: W

05

81 (Power Factor)

UINT8, Unit: %

06

83 (Power Consumption) UINT32, Unit: Wh

07

c9 (Total Current)

UINT16, Unit: mA

00: Close/Close by Command, 10: Close by button

08

70 (Socket Status)

01: Open/Open by Command, 11: Open by button

Examples: 1. Periodic package

087001 058164 07c90200 0374b208 068301000000 048001000000

Channel 08
Channel

Type 70 (Socket
Status) Type

07

c9 (Current)

Channel

Type

06

83(Power Consumption)

Value 01 => Open
Value
02 00=>00 02=2mA
Value 01 00 00 00=>00
00 00 01=1 Wh=0.001 kWh

Channel 05
Channel
03
Channel 04

Type 81 (Power
Factor) Type
74(Voltage)
Type 80 (Active
Power)

Value
64=> 100%
Value b2 08=>08 b2=2226 Voltage=2226 *0.1=222.6V
Value 01 00 00 00=>00 00 00 01=1 W

2. Socket status change
Channel 08

087011 Type 70 (Socket Status)

Value 11 => Open by button

5.3 Downlink Commands
WS51x supports downlink commands to configure the device. The application port is 85 by default.

19

Channel

Type

08 -

03 (Set Reporting Interval)

10 (Reboot Device)

22 (Add Delay Task)

23 (Delete Delay Task)

ff

24 (Overcurrent Alarm)

25 (Button Lock) 26 (Power Consumption) 27 (Reset Power Consumption) 28 (Enquire Electrical Status) 2f (LED Indicator)

30 (Overcurrent Protection)

a5 (Socket Status Reverse)

Description 00 00 ff-Socket close, 01 00 ff-Socket open 2 Bytes, unit: s ff Byte 1: 00 Byte 2-3: delay time, unit: s Byte 4: 10-close, 11-open Note: WS51x supports adding only one task. Later command will cover previous command. 00 ff Byte 1: 00-disable, 01-enable Byte 2: current threshold 0000-disable, 0080-enable 00-disable, 01-enable ff ff 00-disable, 01-enable Byte 1: 00-disable, 01-enable Byte 2: current threshold 01

Examples: 1. Open the supply of the socket.
Channel 08

080100ff Command
01 00 ff=>Open

2. Set reporting interval as 20 minutes.

ff03b004

Channel ff

Type 03 (Set Reporting Interval)

Value b0 04 => 04 b0 = 1200 s = 20 minutes

3. Add a delay task: open the socket after 1 minute

ff22003c0011

Channel ff

Type 22

Value Byte 1:00

20

(Add Delay Task)

Byte 2-3: 3c 00=>00 3c=60s=1min Byte 4: 11=>open

4. Delete the delay task.

ff2300ff

Channel ff

Type 23 (Delete Delay Task)

Value 00ff

5. Enable overcurrent alarm and protection and set current threshold as 10A.

ff24010a ff30010a

Channel

Type

24

ff

(Overcurrent

Alarm)

Value Byte 1: 01=>enable
Byte 2:0a=>10A

Channel

Type

30

ff

(Overcurrent

Protection)

Value Byte 1: 01=>enable
Byte 2:0a=>10A

6. Reboot the device.

Channel ff

ff10ff Type 10 (Reboot Device)

Value ff (Reserved)

7. Disable the LED indicator.

Channel ff

ff2f00 Type 2f (LED Indicator)

Value 00=disable

-END-