Instruction Manual for Danfoss models including: KE04201 Valve Drive Amplifier, KE04201, Valve Drive Amplifier, Drive Amplifier, Amplifier

KE04201 Valve Drive Amplifier Installation Guide

PDF preview unavailable. Download the PDF instead.

AN152886481741en-000401
3500 Annapolis Lane North, Minneapolis, MN 55447 Telephone: (763) 509-2084 Telefax: (763) 559-0108
GENERAL DESCRIPTION

Unit Specification
KE04201 Valve Drive Amplifier

ISSUE: 3

DATE: September 1996

The device is a free­standing amplifier mounted on 4 standoffs. Voltage from a sensor potentiometer, through the amplifier, produces current to drive electrohydraulic actuators. Connections to the amplifier are via screw terminals. An external switch can change gain settings by shorting between two terminals.

DIMENSIONS

CONNECTION DIAGRAM

6,35 (0.25)

114,30 (4.50) 101,60 (4.00)

76,20 (3.00)
57,15 (2.25)

9,65 (0.38)

5,33 (0.21) INSIDE DIA.

12,70 (0.50)
1647
Dimensions of the KE04201 in Millimeters (Inches).

1

2

3

4

KE04201

5

VALVE DRIVE

6

AMPLIFIER

7

8

9

10

MED LOW HIGH

GAIN SWITCH

NO CONNECTION
OUTPUT TO 30  LOAD + - BATTERY
-

+ ACX104C
POTENTIOMETER ROTARY POSITION
SENSOR

POLARITY OF BATTERY CONNECTIONS MAY BE REVERSED TO CHANGE ACTION OUTPUT VERSUS SENSOR INPUT
GAIN SWITCH IS OPTIONAL. JUMPERS MAY BE USED IN PLACE OF SWITCH

1648

OUTPUT CHARACTERISTICS

SUPPLY VOLTAGE 24 Vdc (22 to 30 Volts)
TURN ON VOLTAGE 48% of supply
MAXIMUM OUTPUT CURRENT 600 mA to 30  Load
K14512 UNIT SPEC
© Danfoss, 2013-09

100

90

80

% MAXIMUM

70

OUTPUT VOLTAGE 60

HIGH GAIN MED GAIN LOW GAIN

50

40

30

20

10

10 20 30 40 50 60 70 80 90 100

% SUPPLY VOLTAGE

1649A

K145112OUNFIT1SPEC

ange.

1

