User Manual for Sunco models including: WH-2760K 6 Inch Ultra Thin LED Recessed Ceiling Lights Slim, WH-2760K, 6 Inch Ultra Thin LED Recessed Ceiling Lights Slim, Thin LED Recessed Ceiling Lights Slim, Recessed Ceiling Lights Slim, Ceiling Lights Slim, Lights Slim
Sunco Lighting 12 Pack 6 Inch Ultra Thin LED Recessed Ceiling Lights Slim, Night Light, Baffle Trim, 2700K/3000K/4000K/5000K/6000K Selectable, Dimmable, 14W, Canless Wafer with Junction Box - ETL, ES
Recessed LED Lighting, 6 Inch, Slim, Baffle Trim, Night Light, 850 Lum – Sunco Lighting
Lighting made better. User Manual Recessed LED 6 Baffle Slim Downlight SKU: DL_BS6_NL-WH-2760K support @sunco.com (844) 334-9938 AMERICAN COMPANY Whats in the Box? Nightlight Downlight Le(tlittheerraellbye) light! x1 Light Fixture Get Your Gear x1 Junction Box x1 Installation Template x2 Wire Nuts Tape Hole Saw 1 Ladder Wire Strippers Before You Start Safety Information To reduce the risk of fire, electric shock, or physical injury: · Turn off circuit breaker before installing this fixture. · This product should be installed by a person familiar with the construction and operation of the product the hazards involved. Safety eyeglasses and gloves are recommended. · Abide by related regional and local laws or regulations. · Proper grounding is required to ensure safety. · Do not alter, relocate, or remove wiring during installation. · Do not make or alter any open holes in wiring enclosure or electrical components during installation. · Check for shipping damage before insatalling. If the product is damaged, do not use it. · Keep fixture away from corrosive substances. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.) This device may not cause harmful interference. · Suitable for damp locations at temperature ranging from 4°F to 113°F. Not for use where directly exposed to water. · Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents. · Use safety precautions and abide by regional and local laws or regulations. · This product is not compatible with 3rd party sensors. · This product is not compatible with photo controls. · This product is not compatible with occupancy sensors. · This product is not compatible with timing devices. 2.) This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation. Quickstart Guide 1 2 Step 1 Use template to cut hole. Step 2 Connect supply & junction wires. 22 Step 3 Attach fixture to junction box. Step 4 Insert fixture into ceiling. Installation Guide 6.33" Knockout STEP 1 a. Turn off circuit breaker before installation. b. Cut out 6.33" housing size on Installation Template, then tape onto ceiling in desired location. c. Cut ceiling hole using Installation Template as a guide. STEP 2 a. Open junction box and remove appropriate knockout. STEP 3 a. Connect supply and junction wires using wire nuts: -Black to Black (Live) -White to White (Neutral) b. Tuck connected wires inside junction box & close cover. 3 Installation Guide (Cont.) Ceiling STEP 4 Insert junction box through ceiling hole. a. New Construction Applications: Secure to studs, joists, or similar fixed structural units. b. Remodel Applications: Do not require to secure to studs, joists, or similar fixed structural units. 1 2 STEP 5 a. Attach fixture to junction box using connector as shown on image (1). Tighten connector by hand (2). b. Push up spring clips and insert fixture into ceiling. Turn on circuit breaker and test light. STEP 6 Note: To toggle between downlight and nightlight, turn wall switch and night light off, wait 3 seconds, then switch on. To reset fixture, turn off, wait 5 seconds, then turn on. 4 Product Details Recommended Dimmers Brand LUTRON LUTRON LUTRON LUTRON LUTRON LEVITON KASA SMART KASA SMART Specifications Voltage Wattage Wattage Equivalency Beam Angle Weight Housing Material Dimmable 120V 14W 140W 90° 0.73lbs Plastic Yes Model P-PKG1WB-WH MACL-153M-WH PD-6WCL-WH AYCL-153P-WH DVCL-153P-WH D26HD-2RW HS220 HS220P3 Sccaonmfpoarttihbleefduillmmer list! Average Lifetime Lumens Moisture Rating CRI Usage IC Rated Warranty 50,000 hrs 1200LM Damp 80+ Indoor Yes 7 Years 5 Common Troubleshooting Feeling in the dark about an issue with your product? No If you still need some assistance, please feel free to worries! Our troubleshooting section is here to shed some light contact us with any questions. Our team of lighting experts and provide you with easy-to-follow solutions for any problem. are happy to help brighten your day. Installation Light isn't turning on. Double check if fixture is properly connected and circuit breaker hasn't been tripped. Light isn't bright enough. Dimming Light not dimming to lowest setting. Light not dimming smoothly. Light not compatible with dimmer switch. Flickering Light is flickering when turning on. Light flickering with other lights on the same circuit. Light flickering when turned on. Light flickering when dimmed. Buzzing Fixture buzzing with power outages. Fixture buzzing with appliances or electronic devices. Fixture buzzing when dimmed. Check proper wattage and for unobstructed fixture. Ensure minimum dimmer load requirement is met. Verify dimmer compatibility with fixture. Check light-dimmer compatibility. Consider purchasing compatible switch if necessary. Check that fixture wiring connections are secure. Check that the lights on the same circuit are not overloading the circuit. Verify fixture compatibility and that it is grounded. Verify dimmer switch compatibility. Verify light is connected to surge protector securely. Look for nearby interferences that can cause buzzing. Such as televisions, radios, computers, etc. Verify dimmer switch compatibility. 6 Light Distribution Angle Not No awloirgrhiteisn, gyonuercda?n skip this page AVERAGE BEAM ANGLE (50%): 115.3 DEG C0/180 115.4° C90/270 115.2° UNIT:cd Luminous Intensity Distribution 1 Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles: A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting. An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more. It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated. 7 Customer Support Warranty Policy This product is covered by our industry leading 7 year warranty. It gets even better - scan the QR code for 2 extra years of protection! Secxatnramyeeafrosr! two 30 Day Return Policy At Sunco we value our customers and stand by the quality and performance of our products. If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date. Customer Service Our Los Angeles team of lighting experts is here to assist you with all your needs! Contact us at: Email: support@sunco.com Text or Call: (844) 334-9938 6AM - 6PM PST Monday - Friday 8 Lighting made better. support @sunco.com (844) 334-9938 REV1.0 AMERICAN COMPANYAdobe PDF Library 17.0 Adobe InDesign 19.2 (Windows)