Installation Guide for MOXA models including: UC-2222A-T, UC-2200A, UC-2200A Series Arm Based Computers, UC-2200A Series, Arm Based Computers, Based Computers, Computers
UC-2222A-T | Moxa Moxa | Industrial IT Systems
To install the cards, remove the screw and the protection cover to access the sockets and insert the Micro SD card or the SIM card into the sockets. Make sure ...
File Info : application/pdf, 12 Pages, 922.48KB
DocumentDocumentUC-2200A Series Quick Installation Guide Version 1.2, August 2024 Technical Support Contact Information www.moxa.com/support 2024 Moxa Inc. All rights reserved. P/N: 1802022220012 *1802022220012* Overview The UC-2200A computing platform is designed for embedded dataacquisition applications. The UC-2200A computer comes with two RS232/422/485 serial ports, two 10/100/1000 Mbps Ethernet ports, and a Mini PCIe socket to support cellular modules. These versatile communication capabilities let users efficiently adapt the UC-2200A to a variety of complex communications solutions. Package Checklist Before installing the UC-2200A, verify that the package contains the following items: · UC-2200A Series computer · 3 round stickers for the screws to preventing tampering · Quick installation guide (printed) · Warranty card IMPORTANT! Notify your sales representative if any of the above items are missing or damaged. Panel Layouts The following figures show the panel layouts of the UC-2200A: Top Panel View Bottom Panel View - 2 - Front Panel View LED Indicators LED Status Function Power Green Power plugged in OFF Power is OFF SW Ready/ Yellow System is ON and the computer is working Programmable normally OFF System is not ready. USB/ Green USB device is connected and working normally Programmable OFF USB device is not connected SD/ Green Micro SD card inserted and working normally Programmable OFF Micro SD card is not detected. Wireless Signal Yellow The number of glowing LEDs indicates the Strength/ signal strength: Programmable 2 (both Yellow): Excellent 1 (Yellow): Poor 1 (Yellow, blinking, heartbeat): Very Poor OFF Wireless module is not detected. Serial Tx Green Steady ON: Serial 1/2 not working normally Blinking: Serial 1/2 transmitting data OFF Serial 1/2 not used Serial Rx Yellow Steady ON: Serial 1/2 working normally Blinking: Serial 1/2 receiving data OFF Serial 1/2 not being used. LAN Green Steady ON: A 10/100 M link has been established Blinking: Receiving or Transmitting data Yellow Steady ON: A 1000 M link has been established Blinking: Receiving or Transmitting data OFF No Ethernet connection - 3 - Installing the UC-2200A DIN-rail Mounting The stainless-steel DIN-rail mounting plate comes attached to the product's casing (the specification for the screws is M3 x 6 mm). To mount the UC-2200A on to a DIN rail, make sure that the stiff metal spring is facing upwards and follow these steps. 1. Insert the top of the DIN rail into the slot just below the upper hook of the DIN-rail bracket. 2. Latch the unit firmly onto the DIN rail as shown in the illustrations below: - 4 - Wall Mounting (optional) The UC-2200A can be mounted using a wall-mounting kit, which needs to be purchased separately. Follow these steps to mount the computer on to a wall: Step 1: Use four screws (M3 x 4 mm) to fasten the wall-mounting brackets on the left panel of the computer. Step 2: Use another four screws (M3 x 6 mm) to mount the computer on a wall or a cabinet. Connector Descriptions Power Connector Connect the power jack (in the package) to the UC-2200A's DC terminal block (located on the top panel), and then connect the power adapter. It takes about 30 seconds for the system to boot up. Once the system is ready, the Power LED will light up. ATTENTION The wiring for the input terminal block should be installed by a skilled person. The wire type should be copper (Cu), wire size should be 14 to 16 AWG, and a torque of 0.19 n-m should be used for V+, V-, and GND connections. The wire size of the power input and earthing conductor should be the same. The recommended wire stripping length is 6 to 7 mm. WARNING The product is intended to be supplied by a UL Listed Power Unit marked "L.P.S." (or "Limited Power Source") and is rated 12 to 24 VDC, 0.9 A min., Tma = 75°C (min). If you need further help with purchasing the power source, please contact Moxa for further information. WARNING The means of power cord of adapter should be connected to a socket-outlet with earthing connection. - 5 - WARNING EXPLOSION HAZARD! Do not disconnect equipment unless the power has been removed or the area is known to be non-hazardous. Grounding the UC-2200A Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). SG: The Shielded Ground (sometimes called Protected Ground) contact is the right-most contact of the 3-pin power terminal block connector when viewed from the angle shown here. Connect the SG wire to an appropriate grounded metal surface. Ethernet Ports The two 10/100/1000 Mbps Ethernet ports (LAN 1 and LAN 2) come with RJ45 connectors. The pin diagram of the ports is given below: 10/100 Mbps Pin Signal 1 Tx+ 2 Tx- 3 Rx+ 4 5 6 Rx- 7 8 1000 Mbps Pin Definition 1 TRD(0)+ 2 TRD(0)- 3 TRD(1)+ 4 TRD(2)+ 5 TRD(2)- 6 TRD(1)- 7 TRD(3)+ 8 TRD(3)- Serial Ports The two serial ports (P1 and P2) come with terminal-block connectors. Each port can be configured by software for the RS-232, RS-422, or RS-485 mode. The pin assignments for the ports are given below: Pin RS-232 RS-422 RS-485 1 TXD TXD+ 2 RXD TXD- 3 RTS RXD+ D+ 4 CTS RXD- D- 5 GND GND GND - 6 - Micro SD/SIM Card Sockets The UC-2200A comes with a Micro SD socket for storage expansion and a SIM card socket for cellular communication. The Micro SD card and SIM card sockets are located on the lower part of the front panel. To install the cards, remove the screw and the protection cover to access the sockets and insert the Micro SD card or the SIM card into the sockets. Make sure you insert the cards in the correct direction. Refer to the instructions above the socket. You will hear a click when the cards are in place. To remove the cards, push the cards in before releasing them. Console Port The console port is an RS-232 port that can be connected to a 4-pin pin header cable. You can use this port for debugging or firmware upgrade. The console port is located on the top panel of the device and is accessible after removing the cover of the slot. Pin Signal 1 TxD 2 RxD 3 NC 4 GND USB Port The USB 2.0 port is located at the lower part of the front panel. By default, the USB auto-mount is disable. If enabled, the USB storage is mounted at /media/USB_P1 /media/USB_P2. Antenna Connectors There are three antenna connectors on the front panel of the UC-2200A. W1 and W2 are for cellular modules. A GPS antenna connector is located at the top of the front panel. All three connectors are of SMA type. - 7 - Real-time Clock The real-time clock in the UC-2200A is powered by a lithium battery. We strongly recommend that you do not replace the lithium battery without the help of a Moxa support engineer. If you need to change the battery, contact the Moxa RMA service team. ATTENTION There is a risk of explosion if the battery is replaced with an incorrect type of battery. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. Placing the Round Stickers on a Screws Three round stickers are included in the product package. Stick one of them on to an external screw as indicated in the figure below to help detect unauthorized access and tampering. Follow these steps to place the stickers. 1. Use a cloth to clean the surface of the screws with a 75% alcohol solution. 2. Use a tweezer to place the stickers. 3. Press the sticker down on to the screw with 15 psi (pound/square inch) pressure for at least 15 seconds. 4. Keep the device at room temperature for 24 hours before deploying the devices in harsh environments. NOTE 1. Place the stickers carefully as they are thin and fragile. 2. The ideal environment for the stickers to be stored in is 22°C (72°F) and 50% relative humidity. 3. Keep the extra two stickers in a safe place so that only authorized persons can access them. - 8 - Specifications Input Current Input Voltage Power Consumption Operating Temperature Storage Temperature Models Without Built-in LTE: 600 mA @ 12 VDC 300 mA @ 24 VDC Models With Built-in LTE: 900 mA @ 12 VDC 450 mA @ 24 VDC 12 to 24 VDC (3-pin terminal block, V+, V-, SG) Models Without Built-in LTE: 4.5 W (w/o external USB device attached) 7.2 W (external USB device attached) Models With Built-in LTE: 7.8 W (w/o external USB device attached) 10.5 W (external USB device attached) Models Without Built-in LTE: -40 to 75°C (-40 to 167°F) Models With Built-in LTE: -40 to 70°C (-40 to 158°F) -40 to 80°C (-40 to 176°F) Accessing the UC-2200A Using a PC You can use a PC to access the UC-2200A by one of the following methods: A. Through the serial console port with the following settings: Baudrate=115200 bps, Parity=None, Data bits=8, Stop bits =1, Flow Control=None ATTENTION Remember to choose the "VT100" terminal type. Use the console cable to connect a PC to the UC-2200A's serial console port B. Using SSH over the network. Refer to the following IP addresses and login information: LAN 2 Default IP Address 192.168.4.127 Netmask 255.255.255.0 Login: moxa Password: moxa - 9 - Hazardous Locations Specifications Model: Rating: ATEX information: UC-1222A UC-2222A-T UC-2222A-T-EU UC-2222A-T-AP UC-2222A-T-US UC-1222A, UC-2222A-T: 12-24 VDC, 0.6 A max. UC-2222A-T-EU, UC-2222A-T-AP, UC-2222A-T-US: 1224 VDC, 0.9 A max. II 3G Ex ec IIC T4 Gc UL 23 ATEX 3131X Ambient Range: -40°C Tamb +60°C for UC-1222A Ambient Range: -40°C Tamb +75°C for UC-2222A- T Ambient Range: -40°C Tamb +70°C for UC-2222A- T-EU, UC-2222A-T-AP, UC-2222A-T-US Rated Cable Temp 83.3°C Address of No. 1111, Heping Rd., Bade Dist., Taoyuan City manufacturer: 334004, Taiwan ATTENTION · The peripheral devices should be kept at least 25 mm away from the main device. · The devices are OPEN-TYPE and are required to be installed in a suitable enclosure for the environment such that the devices can only be accessed with use of a tool. · The devices are suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous location only. · The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP 54 in accordance with EN IEC 60079-0 and accessible only by use a tool. · The equipment shall only be used in an area of at least pollution degree 2, as defined in EN IEC 60664-1. - 10 - ATTENTION · · MPE 0.35 mW/cm² 0.23482 mW/cm² 20 BSMI Certification for Taiwan Declaration of the Presence Condition of the Restricted Substances Marking : : UC-2222A-T Equipment name Type designation (Type) Restricted substances and its chemical symbols Unit Lead (Pb) Mercury (Hg) Cadmium Hexavalent chromium Polybrominat ed biphenyls Polybrominated diphenyl ethers (Cd) (Cr+6) (PBB) (PBDE) // - - 1. " 0.1 wt %" " 0.01 wt %" - 11 - Note 1: "Exceeding 0.1 wt %" and "exceeding 0.01 wt %" indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition. 2. "" Note 2: "" indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence. 3. "" Note 3: The "" indicates that the restricted substance corresponds to the exemption. Moxa +886-3-2737575 1111 . : Moxa Inc. : LTE () : UC-2222A-T, UC-2222A-T-AP : Moxa Inc. / - 12 -