Instruction Manual for beyond battery models including: CNB-12-ELEC17, CNB-12-ELEC18, CNB-12-ELEC19, CNB-12-ELEC17 Mini HydroFlex Hydrogen Reference Electrode, CNB-12-ELEC17, Mini HydroFlex Hydrogen Reference Electrode, HydroFlex Hydrogen Reference Electrode, Hydrogen Reference Electrode, Reference Electrode, Electrode
Standard Hydrogen Reference Electrode – Beyond Battery
File Info : application/pdf, 4 Pages, 252.73KB
DocumentDocumentSpecification Data Sheet Beyond Battery Pte. Ltd. sales@beyond-battery.com www.beyond-battery.com Product Information Product Code: CNB-12-ELEC17, CNB-12-ELEC18, CNB-12-ELEC19 Product Name: Mini-HydroFlex Hydrogen Reference Electrode Specifications Material Shaft Material Head Shaft Diameter Shaft Length Diameter Head Heigth Head Sealings Thread Contact Socket Sensor Element Hydrogen Source PEEK (Polyetheretherketone) PTFE (Polytetrafluorethylene) 1.6mm 56mm 20mm 30mm plus 6.2mm for cell holder Fluor rubber G1/8 Gold-plated socket for 2mm plugs Palladium gas diffusion electrode Replaceable hydrogen cell (80521) Operating Instructions Intended Use The mini-HydroFlex is a reference electrode intended only for potential measurement during electrochemical measurements. Safety Information The electrode is intended only for the purpose above. Specification Data Sheet Beyond Battery Pte. Ltd. sales@beyond-battery.com www.beyond-battery.com The manufacturer is not liable for damage resulting from improper use. Observe the following instructions, otherwise the electrode may be damaged, or measurement results may be falsified. When working with chemicals, all relevant safety regulations of the manufacturer and the laboratory must be respected. Commissioning 1.Unscrew the black cap. 2.Take the replacement hydrogen cell and remove the protective foil. There are two openings visible. If any adhesive residue remains, remove it by rubbing with a cloth. 3.Insert the hydrogen cell with these two openings down into the recess. 4.Turn the cap back in. 5.Mark month and year on the label. Attach the sticker to the electrode head. 6.Remove the protective cap from the electrode carefully. 7.Place Mini-HydroFlex in water for 24 hours. Please do not remove the labelling with the serial number and the sticker with the activation date. Specification Data Sheet Beyond Battery Pte. Ltd. sales@beyond-battery.com www.beyond-battery.com Storage After the measurements, rinse the electrode thoroughly with water. Place the hydrogen electrode in a liquid (such as measuring solution, 1 mol/l hydrochloric acid, 1 mol/l sodium hydroxide solution, water) to keep it functional. Runtime of Hydrogen Source Once the end of runtime has been reached, Mini HydroFlex must not longer be stored in liquid. Replace the hydrogen source immediatly. 1.Unscrew the black cap and remove the hydrogen cell. 2.In the recess in the electrode head you see a small o-ring. Please grease this, e.g. with silicone grease. 3.Take the replacement hydrogen cell and remove the protective foil. There are two openings visible. If any adhesive residue remains, remove it by rubbing with a cloth. 4.Insert the hydrogen cell with these two openings down into the recess. 5.Turn the cap back in. 6.Mark month and year on the label. Attach the sticker to the electrode head. Specification Data Sheet 7.Place Mini-HydroFlex in water for 24 hours. Beyond Battery Pte. Ltd. sales@beyond-battery.com www.beyond-battery.com Troubleshooting Make sure all cables are connected correctly. Check if the connections are corroded or damp. Note the lifetime of the hydrogen source! if necessary, replace them. Disposal The electrode must not be disposed of as household waste. Please dispose of the electrode in a separate collection for electrical and electronic equipment according to local regulations. This also applies to the hydrogen cells. lf you have further questions, please contact us. Construction and Dimensions