Instruction Manual for DAYLYRIDE models including: YG90 E-bike Hand Control Panel 1000W 48V 17Ah, YG90, E-bike Hand Control Panel 1000W 48V 17Ah, Hand Control Panel 1000W 48V 17Ah, Control Panel 1000W 48V 17Ah, Panel 1000W 48V 17Ah
Manualul de utilizatori Ebik – DAYLYRIDE
Ebike brugermanual – DAYLYRIDE
File Info : application/pdf, 8 Pages, 315.01KB
DocumentDocumentDAYLYRIDE E-bike User Operation Manual Hand Control Panel Operation Instruction OneOut shell Size and Material Out shell material is ABS, Liquid crystal transparent window material is high hardness acrylic Front view Side view 1 31.8mm stent is available 22.2mm25.4mm28.6mm Transfer Ring Selection Switching view Switch Side View TwoWork Voltage and connection mode 1Work voltageDC24V 36V48V60V (which you can choose on the meter),the others you can customized. 2Connection mode Line sequence of the label connector Order of line 1 2 3 4 5 Instrument Outlet Table: Line sequence of the label connector table Color of line RedVCC BlueK BlackGND GreenRX YellowTX Function Instrument power cord Controller power line Meter earth wire Meter data receiving line Data transmission line of instrument Notes: Part of the products lead wire use waterproof connection. User cannot see the color of lead line. ThreeFunction description 2 1Display function Speed display, power level display, power indicator, failure warning, total mileage, single mileage, headlight display, single driving time display 2. Control, setting up functions Power switch control, headlight switch control, 6Km/h point control, wheel diameter setting, maximum speed setting, idle automatic hibernation time setting, backlight brightness setting, voltage level setting 3.Communication protocolUART All the contents of the display screen(full display in boot 1S) Battery Headlight Cycling model Status display area Brake prompt Cruise Speed PAS and Model Multifunctional display area Show content introduction 3.1 Headlight The instrument can be manually turned on and the brightness of the sensing environment is automatically turned on(light sensitivity support is required). 3.2 Battery power display BATTERY 3.3 Multifunctional display area Total mileage ODO, single mileage TRIP A, single mileage TRIP B, battery current voltage VOL, current operating current CUR, remaining mileage RM; Instrument boot time TM 3.4 Cycling model Walk boost mode; Cruise: constant speed cruise mode; PAS: Power file position: 0 ~ 9 adjustable; 3 3.5 Speed display area Maximum speed MAX, average speed AVG Unit MPH, KM/H The meter will calculate the true speed based on the wheel diameter and signal data 3.6 Vehicle Status Display Area Meaning of fault icon Under-voltage fault Motor fault Controller the fault Status prompt icon Cruise ON Vehicle Status Code Meaning Status State Meaning Code(Decimal) E00 E02 E06 E07 E08 E09 E10 E11 Normal Brakes Battery undervoltage Motor failure Turn malfunctioning Controller failure Communication reception failure Communication dispatch failure Turn the fault Communication failures Remarks 3.7.install P01Backlight brightness the darkest level 1, the brightest level 3; P02: mileage unit 0: KM; 1: MILE; P03: Voltage level: 24V, 36V, 48V, 60V; P04: Dormancy time 0, not dormancy; Other numbers are dormancy times, range: 1-60; Unit minutes; P05: PAS number selection: 0, 3 file mode: 1,5 gear mode: P06: Wheel setting: unit, inch; 4 wheel diameter value: 5.0 ~ 50 Precision: 0.1 inch This parameter is related to the meter display speed and needs to be entered correctly; P07: Speed gauge magnetic steel number: range: 1-100; This parameter is related to the meter display speed and needs to be entered correctly; If it is an ordinary hub motor, the number of magnetic steel is input directly; If it is a high-speed motor, it is also necessary to calculate the deceleration ratio, and the input data = the number of magnetic steel × deceleration ratio; For example: number of motor magnets 20, deceleration ratio 4.3: input data is: 86 = 20 × 4.3 P08: Speed limit setting: Agreement No. 2 range 0-100km / H, 100 means no speed limit; The input data here represents the maximum operating speed of the vehicle: for example, input 25, indicating that the maximum operating speed of the vehicle will not exceed 25km/h; The drive speed is maintained at the set value, Error: ± 1km/h; (The speed limit for power and turning is equal) Note: The value here is based on kilometers. When the unit setting is converted from kilometers to miles, the speed value of the display interface automatically converts to the correct mile value, but the speed limit value data set at this menu under the mile interface is not converted. Is inconsistent with the actual speed limit of the mile speed; P09: zero start, non-zero start setting 0: zero start; 1: Non-zero start;(valid for protocol 2 only) P10: The drive mode is setting 0: Power Drive(how much power is output is determined by the power file bit, and the switch is invalid at this time).(valid for protocol 2 only) 1: Electric drive(by turning the handle drive, the power file bit is invalid at this time). 2: Power Driven and Electric Driven Coexistence P11: Help sensitivity settingrange: 1-24;(valid for protocol 2 only) P12: Help start intensity settingrange: 1-5;(valid for protocol 2 only) P13: Power Magnetic Steel Disk Type Setting 5, 8, 12 Magnetic Steel Types P14: Controller limit value settingrange: 1-20A P15: Controller undervoltage P16: ODO zero setting length press key 5 seconds ODO zero P17 :Automatic cruise optional0: No enabling cruising, 1: enabling cruising; (valid for protocol 2 only)(valid for protocol 2 only) P18: Display speed ratio adjustment range: 50 % ~ 150 %, P19:Zero PAS selection 0: 0 file, 1: does not include 0 file P20 :0:2 Protocol 1:5 S Protocol 2: Standby 3: Standby 5 FourKey Introduction The specific combination of keys is as follows Press the button to use the brief Key operation is divided into short press and long press, and combination key length press Short press is used for rapid/frequent operations, such as the specific key combination position as follows 1. When riding, you need to modify the power/speed file, short press 2. Toggle display data for multi-function areas during cycling, short click Single key length is mainly used to switch the mode / switch state Composite keys(long presses) are used to set parameters because the operation is complex, which can reduce errors (Short press does not make the composite key, because it is easy to trigger mistakenly, so it is too difficult to do Specific operational explanations: modify the power ratio / power file Let's say the current is power mode. 1 Short press Help + 1 2 Short press Help - 1 Toggle speed display 6 Long press, + Toggle speed display Set / Disable 6Km/h Cruise, Switch Headlight, ODO Clear Zero Static state of vehicleslong press Will enter 6KM/h cruise mode, let go of cruise mode;long press Turn the lights on and off P16Menu Interfacelong press five secondsODO clear zero Switching liquid crystal display If the current display is workinglong press on the screen Will turn off the screen, instead turn Toggle multi-function display area content Short Can switch the value of the multifunction display area Set Parameters Long press + Will enter the parameter setting interface. Parameters that can be set include,Wheel diameter(in: inches), number of magnetic steel, liquid crystal brightness, low pressure points, etc.(see settings: P01-P20) Under Settings InterfaceCan be short press or Set the value to perform a minimum-precision unit value operationyou can also long press Continuous Fast Modify Parameters or 7 1.Short press Switch to Next ParameterExit settings and save parameters. If not operated, the modified parameters will automatically exit and be saved after 8 seconds. Note: due to the upgrade of the e-bike, the content of the product will be different from the specifications, but it will not affect your normal use. DAYLYRIDE Bikes AddressNO.68 HOI YUEN ROAD,KWUN TONG,KOWLOON,HONG KONG Contact Email: daylyridebikes@gmail.com Contact Number0519-69656597 Web: https://daylyridebikes.com/ 8