User Manual for BROMIC HEATING models including: Tungsten Smart-Heat Electric Wireless Dimmer Controller, Tungsten Smart-Heat, Electric Wireless Dimmer Controller, Wireless Dimmer Controller, Dimmer Controller, Controller
Official Bromic Heating USA - Wireless Dimmer Controller
Bromic Wireless Dimmer Controller — The Torch Guys
File Info : application/pdf, 8 Pages, 210.84KB
DocumentDocumentTUNGSTEN SMART-HEATTM ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC USER MANUAL Version 1.0 Doc. T744.01_EN (TEMP) TVHET916A07BK ! IMPORTANT READ THIS MANUAL CAREFULLY. SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT THIS MANUAL. KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE. ! IMPORTANT This manual contains important information about the installation, and operation of Tungsten Electric controller. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols: ! DANGER, ! WARNING, ! IMPORTANT · READ THIS MANUAL CAREFULLY before installing or servicing this product. · Improper installation or operation can result in death, severe injury, or property damage. · Use this controller only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons · This controller is intended for fixed installation with 110 - 277 volt power supply. · Installation MUST be carried out by a licensed and authorised technician in accordance with local electrical codes. · For Commercial Use Only NOTE: IMPORTANT INSTRUCTIONS, SAVE THESE INSTRUCTIONS WARNING · The radio signal reception of the device can be affected by the presence of electrical disturbances being transmitted by other appliances working on the same frequency or if the product is shielded by metal parts. · Do not use the remote in places where systems are sensitive to radio emissions. · Do not keep or use the remote in places that are damp, where there is steam, high air humidity, dust or where it is exposed to direct sunlight or similar environmental conditions. · Do not drop the remote. This could damage or reduce the range of action of the remote. · Do not use your nails to press remote buttons. · Keep remote batteries out of reach of children. · Call a doctor immediately if a battery is swallowed. · See remote instruction manual for more details on the included remote. BROMIC HEATING Head Office: 10 Phiney Place, Ingleburn, NSW, 2565, Australia Telephone: +61 2 9426 5222 Fax: +61 1300 735 115 Email: info@bromicheating.com Web: www.bromicheating.com Note: Bromic Heating reserves the right to make changes to specifications, parts, components and equipment without prior notification. This Installation, operation and service manual may not be reproduced in any form with prior written consent from Bromic Heating. Manufactured by Teleco Automation s.r.l. - Italy - www.telecoautomation.com 2 www.bromicheating.com CONTENTS IMPORTANT NOTES & WARNINGS 4 PRODUCT OVERVIEW 5 INSTALLATION & OPERATION 6 TECHNICAL SPECIFICATIONS 7 WIRING DIAGRAM 8 www.bromicheating.com 3 IMPORTANT NOTES AND WARNINGS ! WARNING · This appliance must only be used on a 110 - 277 Volt AC Single Phase electricity supply. · Read all instructions before installing or using this heater · This controller is NOT intended to be installed on recreational · Use this controller only as described in this manual. Any other vehicles and/or boats. use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. · Do not run cord under carpeting. Do not cover with throw rugs, runners or the like arrange cord away from traffic area and · Improper installation, adjustment, or alteration and failure to where it will not be tripped over follow the warnings and instructions in this manual could result in · A controller has hot and arcing or sparking parts inside. Do not severe personal injury, death or property damage. use it in areas where gasoline, paint or flammable liquids are · The manufacturer is not responsible for any damage that could used or stored. happen from improper use. The manufacturer emphasises that · This Installation and Operation manual should not be removed this controller should be used in a responsible manner and that from the site of installation. Installer should leave manual with all procedures, warnings, and safety instructions contained in this the customer for future reference. booklet be followed strictly. · Any guard or other protective device removed for servicing · The product must be fixed on surfaces which cannot be (conducted by an authorised person) must be replaced before damaged by the high temperature. It must be placed in a well operating the controller. ventilated location. It cannot be hermetically closed. It must be fixed vertically, with cable glands downward. · If the controller has not been used, or will not be used, for a long period of time, disconnect power supply · The connection cables must be protected against any accidental impacts, using proper pipes. · For the disconnection from the power line, use an all-pole switch with contacts having a dimension of at least 3,5mm. · This controller is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate controller where MAINTENANCE/ REPAIR it may fall into a bathtub or other water container. · Installation and repair must be carried out by a qualified & · Do not install the controller directly near a bathtub, shower or swimming pool. Any switches or controls must not be within reach of a person in the bathtub, shower or swimming pool. licenced service person only. The controller should be inspected before use and at least annually serviced & inspected by a qualified & licenced service person. · Extreme caution is necessary when any controller is used by or · Do not perform maintenance until controller has been turned near children or invalids and whenever the controller or heater is off and power disconnected. left operating and unattended. · Check for damage to the controller regularly. If damage to · This controller is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or the appliance is suspected, discontinue use immediately and contact the supplier or qualified person to repair. lack of experience and knowledge, unless they have been given · If the supply cord is damaged, it must be replaced by an supervision or instruction concerning use of the appliance by a authorised and licenced person in order to avoid a hazard. person responsible for their safety. · At the end of this product's useful life, it must not be disposed · Keep packaging materials out of reach of children of as domestic waste, but must be taken to a collection · Children and adults should be alerted to the hazards of electrocution and should stay away to avoid serious personal injury · Children should be carefully supervised when they are in the area of the controller. centre for waste electrical and electronic equipment. It is the user's responsibility to dispose of this appliance through the appropriate channels at the end of its useful life. Failure to do so may incur the penalties established by laws governing waste disposal. Proper differential collection and the subsequent · Do not attempt to alter the controller in any manner. · Do not paint any surface of the controller. recycling, processing and environmentally compatible disposal of waste equipment avoids unnecessary damage to the environment and possible related health risks, and also · Do not touch the controller with wet hands at any time. · Do not use or store flammable materials near this appliance. promotes recycling of the materials used in the appliance. For further information on waste collection and disposal, contact your local waste disposal service, or the place of purchase · Do not spray aerosols or flammable materials in the vicinity of the ELECTRICAL CONNECTIONS controller while it is in operation · All connections must be rated for a single-phase 110 - 277VAC · Never operate the controller in an explosive environment such as power supply, with an earth connection. areas where petrol or other flammable liquids or vapours are stored. · Arrange all the necessary safety devices and use only materials INSTALLATION that comply with standard electrical installations. · IMPORTANT - Installation must be carried out by a licensed and · Signal and power voltage wiring (110 - 277Vac) must be authorised person. separated one from the other. · The installer is to ensure that the requirements of the local · The protective device (ln = 32A) must protect the building from authority, local electrical installation code, municipal building overcurrents and short circuit codes, and any other relevant statutory regulations are carried out. · A readily accesible disconnect device shall be incorporated in the building installation wiring. · After unpacking, make sure the controller shows no signs of visible damage or tampering. If the controller appears damaged, · The cable must have a section properly rated according to the contact the place of purchase for assistance. load connected and nominal temperature range up to 90°C. · Remove transit protection before use. 4 www.bromicheating.com PRODUCT OVERVIEW 1 DESCRIPTION The Wireless Dimmer is suitable for resistive and infrared heaters. The controller allows the power output of the heater to be dimmed down for maximum comfort. The control can be used with 110 - 277VAC supply voltages. 1.1 FEATURES Controls ONE 6800W heater at 277/240VAC (3080W at 110VAC) or Controls TWO 3400W heaters at 277/240 VAC (1540W at 110VAC). Wireless control with dimming 0% - 100%. Wired control capabilities Configurable soft-start function for increased heater life. 1.2 KIT CONTENTS Wireless dimmer enclosed in a protective box. 7-channel remote 2. INSTALLATION / SAFETY INFORMATION Responsibility for determining suitability for use in any application / equipment lies solely on the purchaser. Suitability for use in your application is determined by applicable standards such as UL, cUL and CE and the completed system involving this component should be tested to those standards. Please consult with Local authorities and applicable wiring standards for your application. ! WARNING: Operate the Wireless control only when the connected heater is visible to the user. ! WARNING: Isolate mains before installing. Use only on with a properly secured heater. PLUG AND SUPPLY CORD: Use an appropriately rated plug and supply cord - check the power requirements of the connected loads. Socket outlet used must be near the equipment. 2.1 INSTALLATION Study the WIRING DIAGRAM at the end of this document before starting installation. 1. Open cover to the box. 2. Setup the DIP switch settings. Use the `DIP SWITCH FUNCTION' section for guideline. 3. Wire in power and heater as per the wiring diagram. 4. Power on the wireless control. 5. Program the wireless control as per `OPERATION' section. 6. Refit cover to the box. 2.2 OPERATION 2.2.1 DIP switch function Functioning time (activated by PIR) DIP1 = OFF 15 min DIP1 = ON 30 min AREA PIR enabling Configuration of the load type DIP2 = OFF OFF DIP3 = OFF Resistive DIP2 = ON ON DIP3 = ON Inductive (infrared) When Infrared Heater is selected and a command is received, the device activates the load with a "soft start", for extending the lifetime of the heater. ! WARNING: FIRE HAZARD!! Even quality electronic components CAN FAIL, KEEPING FULL POWER ON! Provide a SEPARATE (redundant) protective device where advisable and or required by local codes. ! WARNING: HIGH VOLTAGE!! This controller is used to control HIGH VOLTAGES and must be installed in a GROUNDED enclosure by a qualified electrician in accordance with applicable local and national codes including NEC and other applicable codes. www.bromicheating.com 5 OPERATION 2.2.2 Programming of 7-channel remote 1. Press P1 once and hold down. A continuous beep will sound. 2. While holding the P1 button (during the continuous beep), press a push button on the 7-channel remote that is going to be programmed. The programming is confirmed by an intermittent sound. 100% CH1 CH5 DIM + All buttons are automatically P1 75% CH2 CH6 DIM - memorised with a preset 50% CH3 configuration as in the drawing. Min. CH4 CH7 OFF Once and hold 2.2.3 Copying a function of remote to a new remote. See remote manual for detail on P3 button. 1. Press the P3 button inside the already programmed remote. The active receiver will sound continuously. 2. Within 5 seconds, press a button of the already programmed remote. The sound will be interrupted, and continue for another 5 seconds. 3. During the sound, press a button of the new remote that requires to be programmed. The programming is indicated by an intermittent sound. Memorised P3 Memorised 100% CH1 75% CH2 50% CH3 Min. CH4 CH5 DIM + CH6 DIM - CH7 OFF New 100% CH1 75% CH2 50% CH3 Min. CH4 CH5 DIM + CH6 DIM - CH7 OFF Attention: when a 7 channel transmitter is copied, also its levels will be copied into the new one. 2.2.4 Deleting a remote 1. Press the P2 button once and hold it down. There will be a slow and intermittent sound. 2. During the sound, press the button of the remote that will be deleted. The deletion is indicted by a continuous sound. To be deleted P2 100% CH1 CH5 DIM + 75% CH2 CH6 DIM - 50% CH3 Min. CH4 CH7 OFF Once and hold 2.2.5 Deleting all remote 1. Press the P2 button two times and hold it down the second time until there will be a continuous sound after a quick and intermittent sound. 2. Hearing the sound sequence above indicates that the whole memory of the receiver is deleted. P2 Twice and hold 2.2.6 Deleting a remote from a remote. See remote manual for detail on P3 button. 1. Press the P3 button inside the remote. There will be slow and intermittent sound. 2. During the sound, press the button of the remote that will be deleted. The deletion is indicted by a continuous sound. Memorised P3 To be deleted 100% CH1 75% CH2 50% CH3 Min. CH4 CH5 DIM + CH6 DIM - CH7 OFF 6 www.bromicheating.com TECHNICAL SPECIFICATIONS WIRELESS CONTROLLER Power Supply Max Output Power Fuse Protection Reception Frequency Operating Temperature Range Maximum Remote Memorised Dimensions Protection Class 110/277VAC 50/60Hz (29A. max) 6800W @ 277VAC (25A.) 6800W @ 240VAC (28,5A.) 3080W @ 110VAC (28A.) 32A (FWC high speed, 10 x 38mm) 916MHz (AUS/US) 868.3MHz (EU) -20/+30°C 42 195 x 200 x 75mm IP54 75 15 150 119 227.5 Ø4.2 188 200 Manufactured by Teleco Automation s.r.l. - Italy - www.telecoautomation.com The manufacturer reserves the right to modify design features and technical data without notice. www.bromicheating.com 7 WIRING DIAGRAM Do not operate in the high voltage area of the electronic board, when it is supplied. LED ERROR L3 TR1 DIP SWITCH P1 P2 P3 AREA 1 POWER SUPPLY (LIVE) 2 POWER SUPPLY (NEUTRAL) 3 POWER SUPPLY (GROUND) 4 GROUND (OUTPUT ELEMENT 1) 5 GROUND (OUTPUT ELEMENT 2) 6 OUTPUT ELEMENT 1 (NEUTRAL) 7 OUTPUT ELEMENT 2 (NEUTRAL) 8 OUTPUT ELEMENT 2 (LIVE) 9 OUTPUT ELEMENT 1 (LIVE) M5-T1 PUSHBUTTON INPUT (N.O.) M5-T2 PIR INPUT (N.O.) M5-COM INPUTS COMMON NTC TEMPERATURE PROBE INPUT M4-LED+ LED INDICATOR OUTPUT (+) M4-LED- LED INDICATOR OUTPUT (-) AREA M4-T4 PUSHBUTTON INPUT (N.O.) L1, L2 INPUT LED L3 RADIO RECEIVER LED LED ERROR ON = OVERLOAD FLASHING = OVERHEATING LED BAR OUTPUT LEVEL TR1 TEMPERATURE ADJUSTMENT P1-P3 PROGRAMMING BUTTONS - S + EXTERNAL LEVEL VISUALIZER 110-277Vac IN HOT, BLACK (120V)* / L HOT, RED (120V)* / N GND Section 4 mm Note: Neutral (N) is not required when using split-phase 220-240V. 8 Section 1.5 mm L N Gnd L N Gnd ELEMENT 1 1.5KW (110Vac) 3.4KW (240Vac) 3.4KW (277Vac) ELEMENT 2 1.5KW (110Vac) 3.4KW (240Vac) 3.4KW (277Vac) www.bromicheating.com