User Guide for DIGITUS models including: DN-3P16-050, MIDA-EVST-11KW, 3-Phase Wall-Box 11KW with 5m Standard Charger Cable, MIDA-EVST-11KW 3-Phase Wall-Box 11KW with 5m Standard Charger Cable
2022-05-03 — Installation. ➢ Installation must be carried out by personnel with professional qualification, otherwise there is a risk of electric shock.
File Info : application/pdf, 20 Pages, 479.57KB
DocumentDocument3-Phase Wall-Box 11KW with 5m standard charger cable Quick Installation Guide DN-3P16-050 Rev 1.0 Please read this manual carefully before installation and use, otherwise, it may interfere with the normal use of the equipment and even risk causing personal injury. 1. Safety and Points for Attention 1.1. Installation Installation must be carried out by personnel with professional qualification, otherwise there is a risk of electric shock. It shall be installed in the place without violent vibration and impact and placed vertically to facilitate ventilation. It shall be installed on noncombustible materials such as metal, or there is a risk of fire. Do not drop any foreign objects, especially metal objects, into the inside of the charging station or there is a risk of fire. The lead nose of the charging station must be securely attached or there is a risk of damaging the equipment. The power supply input cable should have at least 5G2.5mm² (minimum) copper cable while it is recommended 5G4mm² copper input cable. 1.2. Maintenance It is recommended that routine safety inspection visits to charging station be conducted at least once a week. Please do not attempt to disassemble, repair, or modify the charger by yourself. If there is a need for maintenance or modification, please contact certified 2 Electrician/Installers. Improper operation may cause damage to the equipment. Do not put inflammable, explosive or combustible materials, chemicals, combustible steam and other dangerous goods near the charging station, otherwise there is a risk of fire. Please keep the charging adapter clean and dry and wipe with a clean, dry cloth if soiled. Do not touch the charging station with your hand when charged. 1.3. Operation Strictly forbidden for Children or persons of restricted capacity to approach the charging station to avoid injury. Forced charging is strictly forbidden when the electric vehicle or charging station fails. Electric vehicle can only be charged with the engine is off and stationary. Do not charge in rainy and thunderous weather. It is strictly prohibited to use the charging station when the charging adapter or charging cables are defective, cracked, worn, broken or the charging cables is exposed. If you find any, please contact the supplier in time. In case of rain or thunder, please charge with care. DO not use the device in extreme temperatures outside the normal operating range at -30°C to 55°C. 3 Lightning-proof Overvoltage protection Overcurrent protection Overheat protection Flame resistance Waterproof IP55 Leakage protection IEC 62196-2 (Type 2) connector 4 2. Feature · Compact size design with charging power up-to 11kW. · Charging plug meet IEC 62196-2 (Type 2) standard. · Charging adapter is with IP55 waterproof rating for outdoor usage. · EV Charger meets IEC 61851 control principle · Long durability: Charging adapter at no-load plug in/ pull out > 10000 times · High impact of external force resistance 3. Package Content · AC EV Charging Station including charging cable x 1pc · Mounting accessory set including screws x 1set · Cable management hook x 1pc · User manual x 1pc 5 4. Technical Specification Electric parameters Functional description Charging mode Input Voltage Rated frequency Branch breaker Input circuit conductor Charging control Display screen Indicator lights Communication interface Safety precautions Mode 3 3-phase AC, 400V±15% 50/60Hz N/A L1/ L2/ L3/ N/ PE Copper cable is recommended with appropriate conductor size. Direct "Plug-andcharge" N/A LED light indicator with 3-color (status, connect, charging and fault) Onboard RS-485 interface Surge protection, Over temperature protection, RCD Type A + DC6mA, Over/under voltage protection, over current protection, ground protection 6 Mounting Wall-mounted Charging adapter IEC 62196-2, Type 2 Mechanical parameters Charging cable length Dimension (H×W×D) Weight 5m 310mm × 161mm × 79.8mm 5kg IP rating IP55 Operational environment Environmental conditions Vibration Storage temperature Operating temperature Operating humidity Indoor or outdoor, good ventilation, no flammable, explosive gases No violent vibration and impact -40~75°C -30~55°C 95%RH, no water droplet condensation 7 5. Product Dimension 6. Internal Wiring on AC Terminal Block AC Input Cable Pin Definition L3 L2 L1 N PE 8 7. Installation process 1. Position the mounting bracket at the desired height or following the recommendation below. Install the bracket onto the wall with the screws packed inside the package 9 2. Open the back-cover of the Charger and pre-install the AC input cables following the pin definition on the Terminal Block. AC Input Cable Pin Definition L3 L2 L1 N PE 10 3. Mount the EV Charger onto the wall by hanging it on the installed bracket. Install another screw from the front to lock it. 11 4. It is recommended to install the Charging adapter hook onto the wall at an installation height of 800mm from the ground 12 5. To complete the installation with an external circuit breaker at the input side. 13 8. Power-on inspection 8.1. Check before operation Before operation, please check carefully and ensure the following: · The installation position of the EV Charger is convenient for operation and maintenance · The EV Charger and its accessories are correctly connected and installed firmly · Reasonable selection of leakage protection switch for AC inlet · No external objects or parts are left on the top or inside the Charging Station 8.2. Power on the device 1. Switch on the AC power inlet leakage protection circuit breaker 2. Power on the Charger: It would take 5 seconds initially for power-on self-check. 3. After the power-on self-check is completed, the LED indicator would show the status: a. Normal standby: the green light is always (constant) ON. b. Equipment failure: Red light is always (constant) ON. 4. When the EV Charger is showing GREEN light constant ON, then you can take out the Charging adapter to start charge your Electric Vehicles. 14 5. If your EV Charger is showing RED color, please check below LED status for error code or contact the manufacturer 8.3. Start charging 1. Park the electric car into place, turn off the engine, and put the car under braking. 2. Pick up the charging adapter from the Charger after Charger is showing Green light constant ON after poweron self-test. 3. Plug the charging adapter into the AC charging socket of the electric vehicle and you will see Blue light flashes indicating charging in progress. 4. As this is direct "plug-and-charge" charging station, it will automatically enter the charging process. 8.4. Normal stop charging 1. There are two ways to stop charging: a. Automatic stop when fully charged. b. Manually stop by removing the charging adapter from the car socket. 2. Pull the charging adapter out from the vehicle to complete charging process. If you can't pull out the adapter, usually because the vehicle is locked, press the unlock button of the vehicle key and the adapter can be pulled out. 15 8.5. Abnormally stop charging 1. Forced fault stop: A fault stop initiated by the onboard charger of vehicle. 2. Automatic fault stop: A fault stop initiated by the charging station due to internal protection mechanisms 9. LED indicator for Status and Error codes LED Color Indicator Index Description Green Blue Red 1 Initial Power-on ON Off Off Connecting (hand- 2 shaking Flashes Off Off with EV) Definition Ready to be used after 5 seconds of Power-On Initialization. When LED is Green, it is ready to be used. After self-test, the device is READY to plug into Electric Carsocket. During connection, there is a handshaking process with EV which the Green LED will flashes quickly. 16 During charging, 3 Charging starts Off Flashes Off the Blue light flashes as charging in progress Charging 4 Off finishes When charging On Off finishes, the Blue light will be constant ON When Control 5 Control Pilot Off Off Fault (0.5s) Pilot pin detects error during handshaking Pin Error 1 time with Electric vehicle 6 Under Fault Error detected: Off Off (0.5s) when Voltage Voltage 2 time < 304Vac 7 Over Voltage Off Fault Error detected: Off (0.5s) When Voltage 3 time > 456Vac 17 When RCD detects leakage, the relay automatically disconnected the 8 Leakage Detected Fault system. It needs to be re-powered Off Off (0.5s) after the fault is 4 time removed before the relay is allowed to close to function again When over current is detected, the relay is disconnected then Fault it will automatically 9 Over Current Off Off (0.5s) restart after 10s. 5 time When over current is detected, the charging would be ended. Temperature >85 degrees, it will disconnect the relay automatically. 10 Over Temp Off Off Fault (0.5s) Wait for the device 6 time to cool down before turning on the EV Charger again 18 RCD leakage 11 detection Off self-check 12 Emergency Stop button Off When wall-box is powered-on each time, it will trigger Fault a self-check for Off (0.5s) RCD leakage 7 time detection. If RCD is not working, it will flash red color LED 7x times. When the emergency stop button is pressed on the side of the wall-box, it will Off Fault (0.5s) 8 time flash 8x times red LED to indicate this situation. Please release the Emergency Stop button after all fault is removed to return back to normal state. 19 Hereby Assmann Electronic GmbH, declares that the Declaration of Conformity is part of the shipping content. If the Declaration of Conformity is missing, you can request it by post under the below mentioned manufacturer address. www.assmann.com Assmann Electronic GmbH Auf dem Schüffel 3, 58513 Lüdenscheid Germany 20