IT8200
Regenerative AC/DC Electronic Load

IT8200
Regenerative AC/DC Electronic Load

Adopting advanced SiC technology, IT8200 Series is a regenerative programmable AC/DC electronic load. It is power regenerative, which not only saves electricity and cooling costs for you, but also good for energy saving and environmental protection. AC load mode supports both rectification andnon-rectification, providing CC/CR/CP/CS/CC+CR/CE operating modes. It can simulate multiple circuit topologies under CE mode such as single-phase rectification RLC Circuit and parallel RLC Circuit. IT8200 can be applied to the test of V2G, EVSE, PCS, UPS, inverter, etc.

IT8200 Series adopt a high power density design, and the power can reach 15kVA in a 3U unit. After parallelconnection, the power can be extended to 960kVA at most.Its LCD touch screen with graphical UI interface can directly define differentwaveforms. Combined with arbitrary waveform editing function and perfect protection function, it is an ideal choice for R&D testing andsystem construction.

FEATURE
Adopt advanced SiC technology High power density, 15kVA in 3U unit Measure up to 16 parameters including Vrms/Arms/Freq/ CF/PF/UTHD/ITHD/±Vpeak. Master/Slave parallel, power up to 960kVA High efficient energy regeneration Voltage - 350 VL-N Comprehensive working modes selectable: single-phase, three-phase, reversed phase. Rated voltage can be extended to 200% under reversed phase Frequency: 16-500Hz Support NORMAL/LIST/SWEEP/Surge&Sag modes Built-in various waveforms Touch screen, simple UI for easy operation Built-in USB/CAN/LAN/Digital IO interface, optional GPIB /Analog&RS232 DC mode supports nine working modes, including CC, CR,CP, and CV

AC mode supports CC/CP/CR/CS/CC+CR/CE multiple working modes, CE mode can simulate various circuit topologies such as single-phase rectifier RLC and parallel RLC AC mode supports both rectification and non-rectification modes Adjustable crest factor: 1.414 ~ 5.0 Supports phase shift, ranging from -90 º to 90.0 º *1 The unit power factor1 function allows the current waveform to vary with the voltage waveform and the power factor is as close to 1 as possible In three-phase AC mode, two access modes are supported: Y and  Comprehensive harmonics measurement and analysis, up to 50th. Built-in IEC61000-3-2/3-12 pre-compliance test standard *2 Support the loading and unloading angle control, the full range of 0-359° can be set Various protection functions such as Protect auto clear (UV&FE auto Clear), POVP, POCP, UVP, Software watchdog

* 1 After the rectification function is enabled, the setting range of phase shift is restricted by the peak factor * 2 Voltage/current harmonic analysis, current harmonic simulation, fundamental wave  60Hz

01 IT8200 Regenerative AC/DC Electronic Load

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load
APPLICATION

Solar

Energy storage

Grid-connected inverter, Hybrid inverter

PCS, Micro-grid

EV
V2G, EVSE, converters

Power electronics
UPS, AC power supply, frequency converter, generator

Electronic components
Circuit breaker, fuse, connectors,
switches

Model IT8203-350-30U IT8205-350-30U IT8206-350-90 IT8209-350-90 IT8212-350-90 IT8215-350-90 IT8230-350-180 IT8245-350-270 IT8260-350-360 IT8275-350-450 IT8290-350-540 IT82105-350-630 IT82120-350-720 IT82135-350-810 IT82150-350-900 IT82165-350-990

Voltage 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V

* Please contact ITECH for high power needs. * The above specifications are subject to update without notice.

Current 30 A 30 A 90 A 90 A 90 A 90 A 180 A 270 A 360 A 450 A 540 A 630 A 720 A 810 A 900 A 990 A

Power 3 kVA 5 kVA 6 kVA 9 kVA 12 kVA 15 kVA 30 kVA 45 kVA 60 kVA 75 kVA 90 kVA 105 kVA 120 kVA 135 kVA 150 kVA 165 kVA

Phase 1 1 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3

Height 3 U 3 U 3 U 3 U 3 U 3 U 6 U 15 U 27 U 27 U 27 U 27 U 37 U 37 U 37 U 37 U

02 www.itechate.com

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load

Regenerative AC/DC electronic load
The IT8200 series are new regenerative AC Electronic Load with 88% energy recovery capability. Whether in AC mode or DC mode, the power generated by the DUT can be fed back to the grid,rather than being dissipated as heat, which protects the environment and save the cost of electricity, HVAC and cooling infrastructure.

Production facility
24hours/day x 7 working days x 52 weeks

Power (kW) 15 90 165 960

Electricity saved (appr.USD/year)
17,428 104,570 191,712 1,115,412

CO2 emission reduced (appr.ton/year)
124 745 1,365 7,943

R&D lab
8hours/day x 5 working days x 52 weeks

Power (kW) 15 90 165 960

Electricity saved (appr.USD/year)
4,368 26,208 48,048 279,552

CO2 emission reduced (appr.ton/year)
30 177 325 1,891

* The data is based on : 1. approximate electricity price 0.14USD/kWh for industry facility 2. 1kWh power consumption  0.997 CO2 emission * The extra cost of air conditioning is not included.

High power density
The IT8200 series is available from 3U stand-alone to 15 U/27 U/37 U cabinets and other different compact structure design. It can meet different test requirements of users from 5k~165kVA, and the voltage output can reach 350V. The size of 3U/15 kVA model is only 1/12 of a conventional type of AC power supply, saving a lot in space and cost and providing users with a high-power test program that can be directly placed on the experimental table.
Master/slave parallel, large capacity free combination
The 3U model of IT8200 can be master-slave paralleled to to reach 960kVA output at most. It can improve the output current and power capacity to meet the requirements of higher power testing. IT8200 comes with synchronous On/Off input and output signals, which ensure the synchronization of paralleling and ensures synchronous current sharing of multiple modules. After paralleling, all functions are retained and there' s no loss of accuracy, making the construction of the power system faster, more flexible, and more economical, either it is a stand-alone test or ATE system.
3U 3~15 kVA

03 IT8200 Regenerative AC/DC Electronic Load

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load

High efficient power regeneration
After parallel, Power up to
960kVA
Single-phase/ Three-phase/ Reverse phase
IT8200

Optional interfaces

Multiple operating modes
Various protection functions

15U 27U 37U

04 www.itechate.com

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load

Single-phase, three-phase, reverse-phase
The IT8200 series has single-phase, three-phase, and reverse-phase output modes, which can be selected through the menu. Under reverse mode, the single-phase 350V input voltage can be increased to 700V with the power down to 2/3 of the original. Under the three-phase mode, you can choose a Y-type or a -type connection. The Y-type connection supports the C-phase loss.

1
AC
single phase AC

1
DC
single phase DC

3
AC
three phase AC

AC

D E LTA

WYE

reverse phase ¶-type connection Y-type connection

AC

three phase

three phase

WYE
Y-type phase loss

Y-type phase loss
CF 1.414-5.0
The crest factor indicates the extreme peaks of the waveform. For applications that require a pure sine wave, it is desirable to have a CF value of the load current waveform of 1.414 or as close as possible. However, in practical applications, the peak shape of the current waveform of the load may become very sharp and its CF is often higher than 1.414. At this time, the starting point of the sine wave starts to shift from 0 degrees to the positive degree. So you need to correct the waveform. The Crest Factor of the IT8200 can be adjusted from 1.414 to 5.0, and it also allows to set the phase shift angle from -90 º~90 º, correct the resulting amplitude, and keep the RMS unchanged. This enables more accurate simulation of field test conditions to ensure the reliability of the unit under test (UUT).

CC phase leading / lagging

CC mode,CF=5

CC mode,CF=1.414

CC mode,CF=3

05 IT8200 Regenerative AC/DC Electronic Load

Phase=90º Phase=-90º

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load

IT8200 Regenerative AC/DC Electronic Load

AC/DC load conditions emulation

DC load mode
Constant Voltage (CV)

AC load mode
Constant Current (CC)

Constant Current (CC)

Constant Resistance (CR)

Constant Resistance (CR)

Constant Power (CP)

Constant Power (CP)

Constant apparent power (CS)

CC+CV

CC+CR

CR+CV

CE RLC

CP+CV

CC+CR

CP+CV+CR+CC

Single rectified RLC Parallel RLC ......

I(t)

RL

RC

V(t)

R

L

C

I(t) V(t)

Parallel rlc RS L
RC

Rectifier single phase rlc
IT8200 AC electronic load can enable the 'Rectified' function in AC mode, so that the load works in the first and third quadrants to ensure that the voltage and current flow always in the same direction. At this time, full wave, positive half wave, or negative half wave can be freely selected.

full wave

positive half wave

negative half wave
06 www.itechate.com

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load
Waveform
Oscilloscope function
The IT8200 series has built-in digital oscilloscope functions, which can collect time domain signals of voltage and current, phase relationship, and perform waveform triggering, etc. Its sampling rate is as high as 10us, up to 6 oscilloscope curves can be displayed at the same time, and instantaneous analysis can be completed. Further more, with its data recording function, you can observe the output for a long time, and store the obtained data to an external storage device for secondary analysis. A wide variety of test requirement can be met even without a data acquisition instrument or an oscilloscope.
Data record
Thanks to the data record function, the IT8200 series can continuously record data for up to 7 hours at the fastest time interval of 100ms, and provides you with a 'trend' graph to check the curve of the entire test process. Up to 6 curves can be displayed simultaneously. In addition, you can also observe the precise data at a certain moment in the trend graph by sliding on the front panel. This function helps to analyze the abnormality of DUT during long-term testing, inflection point under loading, etc. Test data can be exported by a USB for further analysis.
Harmonic analysis
Harmonic analysis functions include both voltage and current harmonic measurement. In the harmonic mode, the voltage and current total harmonic distortion (THD) and the phase difference test of the harmonic to the fundamental wave can be realized. In addition, you can make multiple harmonic measurements. The test results are displayed in a list, histogram or vector diagram, easy to check. In the meantime, IT8200 AC electronic load also has built-in IEC 61000-3-2 / 61000-3-12 regulations, which can be recalled directly for pre-compliance testing.
07 IT8200 Regenerative AC/DC Electronic Load

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load
Built-in multiple waveforms
IT8200 has built-in sine, triangle, square, trapezoidal and clipped-sine wave. These waveforms can be recalled through the menu and displayed on the screen. Further more, the complex testing requirement can be met by further editing the relevant parameters.

Harmonic simulation
Harmonic test is one of the important test items for EMC immunity. IT8200 series has built-in 30 THD waveforms for quick recall. Thanks to the high-speed DSP technology, IT8200 series can also customize THD waveform. By setting the amplitude and phase, it can simulate up to 50th order harmonics (fundamental frequency is 50Hz or 60Hz), forming a periodic distortion waveform.

Intuitive software interface
IT8200 series provides free PC software PV8200 with an intuitive GUI. Meanwhile, it allows remote control, even the ATE models without display screen can be programmed, communicated and monitored.

08 www.itechate.com

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load LIST/SWEEP/Surge&Sag
IT8200 series supports NORMAL,LIST and SWEEP mode. Each mode can work with Surge&Sag function. In LIST mode, you can edit multiple steps and any waveform can be selected for each step. One List file can contain maximum 200 steps. Parameters such as frequency, amplitude, running time, and rising slope of each waveform can be edited.
The SWEEP function helps to test the efficiency of the switching power supply in AC mode, grab the voltage and frequency of the maximum power point, and make the setting parameters change step by step.
Surge&Sag works in each mode of NORMAL/LIST/SWEEP. Use trigger or cycle to control the drop of surge and sag, set the starting angle of the drop, and support waveform smoothing, symmetrical and asymmetrical waveform operations. Waveforms can be quickly created to reproduce waveform distortions or transient events such as spikes, dropouts or any other anomalies.
09 IT8200 Regenerative AC/DC Electronic Load

Your Power Testing Solution
IT8200 Regenerative AC/DC Electronic Load

AC Input

Wiring connection Line voltage Line current Apparent power Frequency Power factor

Input voltage Input frequency
Input current
Input power
Current range Resolution Accuracy*3

Range
Resolution Accuracy

AC mode

Range
Resolution Accuracy
Range Resolution Accuracy*5
R Range L Range C Range Rc Range RL Range IL Range Max peak current
R Range L Range C Range RS Range Vcap Range Vdiode RangeL Max peak current

IT8215-350-90 AC parameter

3phase 3wire + ground(PE)

RMS

( 200 ~ 220 V) ±10% *1 ( 380 ~ 480V ) ±10%

RMS

< 34A

< 17kVA

45 ~ 65Hz

typ

0.98

Input

VLN

30 ~ 350V

VLL

51.96 ~ 606V(3phase)/60 ~ 700V(reverse)

16 ~ 500Hz

RMS

90A(1phase)/30A(3phase/reverse)

Peak

270A(1phase)/90A(3phase/reverse)

Crest Factor *2

5

Per Phase

5kVA

Max. Power

CCCCmmoodedesestetitntging

10kVA(reverse phase)/15kVA(1phase/3phase)

RMS

90A(1phase)/30A(3phase/reverse)

0.01A <0.1% + 0.2% F.S.(DC,16Hzj150Hz)/<0.2% + 0.3% F.S.(150.1Hz ~ 500Hz *4 )
CP mode setting

Max. Power

15kW(1phase/3phase)/10kW(reverse phase)

Per Phase

5kW(3phase)

0.001kW <0.4% +0.4% F.S.(DC,16Hzj500Hz)

CS mode setting

Max. Power

15kVA(1phase/3phase)/10kVA(reverse phase)

Per Phase

5kVA(3phase)

0.001kVA <0.4% +0.4% F.S.(DC,16Hzj500Hz)
CR mode setting 0.334j388.88(1phase) / 1.002j1166.6 (3phase/reverse phase)

0.001 0.4%+0.4%F.S. Circuit Emulation(CE)-Parallel rlc

0.334j388.88(1phase) / 1.002j1166.6(3phase/reverse phase)

1 ~ 2000uH(1phase)/3 ~ 2000uH(reverse phase)/3 ~ 2000uH(3phase)

0.001 ~ 9900uF(1phase)/0.001 ~ 3300uF(reverse phase)/0.001 ~ 3300uF(3phase) 0.334j388.88(1phase) / 1.002j1166.6(3phase/reverse phase) 0.334j388.88(1phase) / 1.002j1166.6(3phase/reverse phase)

0 ~ 272.7A(1phase)/0 ~ 90.90A(reverse phase)/0 ~ 90.90A(3phase)

272.7A(1phase)/90.9A(reverse phase)/90.9A(3phase) Circuit Emulation(CE)-Rectifier single phase rlc 0.334j388.88(1phase) / 1.002j1166.6(3phase/reverse phase)

0.1 ~ 2000uH(1phase)/0.3 ~ 2000uH(reverse phase)/0.3 ~ 2000uH(3phase)

0.001 ~ 9900uF(1phase)/0.001 ~ 3300uF(reverse phase)/0.001 ~ 3300uF(3phase) 0j388.88(1phase) / 0j1166.6(3phase/reverse phase)

0 ~ 499.924V(1phase)/0 ~ 499.924V(reverse phase)/0 ~ 499.924V(3phase)

0 ~ 5V(1phase)/0 ~ 5V(reverse phase)/0 ~ 5V(3phase)

272.7A(1phase)/90.9A(reverse phase)/90.9A(3phase)

* 1 (200~220) ±10%, models of 12Kw and above output 60% of rated power. * 2 Under the input frequency of 50Hz/60Hz, the maximum CF is 5 without exceeding the peak current; under the condition of full current and full power, the maximum CF is 3. * 3 For frequency <150Hz, the minimum current for accuracy test is 1%F.S., for frequency>150Hz, the minimum current for accuracy test is 3%F.S. * 4 When LoopSpeed is Low, it is more adaptable to the load; when LoopSpeed is Fast, the dynamic response is faster; when the frequency is high, use Fast mode. * 5 Test frequency <150Hz, works with this specification. * The above specifications are subject to update without notice.

10 www.itechate.com

AC mode

Range
Resolution Accuracy

DC mode

Range Resolution Voltage Current Current rising time

Voltage RMS
Current RMS
Peak current
Input active power Input reactive power Input apparent power CF
PF
Harmonic

Range Resolution Accuracy Range Resolution Accuracy Range Resolution Accuracy Range Resolution Accuracy Range Resolution Accuracy Range Resolution Accuracy Range Resolution Range Resolution Accuracy Max.harmonic analysis

Regenerative Pmax Output current THD

Efficiency

typ

Protection

Dimension

Weight

Working temperature

Programming response time

Phase angle setting -82.8º~+82.8º(Rectified Mode *6)
-90º~+90º 0.01
1% F.S. CF setting 1.414 ~ 5.0
0.001 30 ~ 499V 0 ~ 90A(1phase)
200s Measure Parameter
0 ~ 350Vrms 0.01
< 0.1%+0.1% F.S.(DC,16Hzj500Hz) 0 ~ 90A 0.01A
< 0.1% + 0.2% F.S.(DC,16Hzj150Hz)/< 0.2% + 0.3% F.S.(150.1Hz ~ 500Hz) 0 ~ 270A 0.1A
< 0.3% + 0.6% F.S.(16Hz ~ 500Hz) 0 ~ 15kW 0.001kW
< 0.4% +0.4% F.S. 0 ~ 15kVAR 0.001kVAR
< 0.4% +0.4% F.S. 0 ~ 15KVA 0.001KVA
< 0.4% +0.4% F.S. 1 ~ 5 0.01 0.1 ~ 1 0.01 1%F.S.
up to 50orders(50/60Hz) Power regeneration
15kVA < 5% Other 88% OVP, OCP, OPP, OTP, FAN,ECP 483.00mm (W)*151.3mm (H)*700mm (D) (841.6mm cover and holder included) 42kg 0¥~50¥ 2ms

* 6 In the rectifier load mode, the setting range of the phase angle is related to CF. The larger the CF, the larger the settable range of the phase angle. * The above specifications are subject to update without notice

ITECH ELECTRONICS
www.itechate.com info@itechate.com

