Test Report

Report No.: BL-SZ23A1021-701

Test Report Details

Applicant: Ugreen Group Limited

Address: UGREEN Building, Longcheng Industrial Park Longguanxi Road, Longhua, ShenZhen, China

Equipment Type: Ergonomic Wireless Mouse

Model Name: MU006 (refer to section 2.3)

Brand Name: UGREEN

FCC ID: 2AQI5-90855

Test Standard: 47 CFR Part 2.1093 (refer to section 3.1)

Sample Arrival Date: Oct. 23, 2023

Test Date: Oct. 27, 2023 - Nov. 17, 2023

Date of Issue: Nov. 29, 2023

Issuing and Approval Information

Issued By: Shenzhen BALUN Technology Co., Ltd. [Accreditation Mark: BALUN]

Tested by: Xiong Lining [Signature of Xiong Lining]

Checked by: Xu Rui [Signature of Xu Rui]

Approved by: Hanson Lin (Vice General Manager) [Signature of Hanson Lin]

Revision History

Version Issue Date Revisions Content
Rev. 01 Nov. 29, 2023 Initial Issue

Table of Contents

1 GENERAL INFORMATION ......................................................................................................... 3

1.1 Test Laboratory .............................................................................................................. 3

1.2 Test Location.................................................................................................................. 3

2 PRODUCT INFORMATION ......................................................................................................... 4

2.1 Applicant Information...................................................................................................... 4

2.2 Manufacturer Information ............................................................................................... 4

2.3 General Description for Equipment under Test (EUT) ................................................... 4

2.4 Technical Information ..................................................................................................... 4

3 SUMMARY OF TEST RESULT ................................................................................................... 5

3.1 Test Standards ............................................................................................................... 5

4 DEVICE CATEGORY AND LEVELS LIMITS .............................................................................. 6

5 ASSESSMENT RESULT ............................................................................................................. 8

5.1 Output Power ................................................................................................................. 8

5.2 Tune-up power ............................................................................................................... 8

5.3 RF Exposure Evaluation Result ..................................................................................... 8

5.4 Conclusion...................................................................................................................... 8

1 GENERAL INFORMATION

1.1 Test Laboratory

Name Address Phone Number
Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China +86 755 6685 0100

1.2 Test Location

Name Location Accreditation Certificate
Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China
1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China
The laboratory is a testing organization accredited by FCC as a accredited testing laboratory. The designation number is CN1196.

2 PRODUCT INFORMATION

2.1 Applicant Information

Applicant Address
Ugreen Group Limited UGREEN Building, Longcheng Industrial Park Longguanxi Road, Longhua, ShenZhen, China

2.2 Manufacturer Information

Manufacturer Address
Ugreen Group Limited UGREEN Building, Longcheng Industrial Park Longguanxi Road, Longhua, ShenZhen, China

2.3 General Description for Equipment under Test (EUT)

EUT Name Model Name Under Test Series Model Name
Ergonomic Wireless Mouse MU006 90855, 25752, 25753, 15508, 25709, 90545B, 90545
Description of Model name differentiation: All models are same with electrical parameters and internal circuit structure, but only differ in model name. (this information provided by the applicant)
Hardware Version Software Version Dimensions (Approx.)
V1.0 V1.0 N/A
Weight (Approx.)
N/A

2.4 Technical Information

Network and Wireless connectivity
Bluetooth (BLE)
2.4G ISM Band

The requirement for the following technical information of the EUT was tested in this report:

Operating Mode Frequency Range Antenna Type Exposure Category EUT Type
Bluetooth, 2.4G ISM Band Bluetooth: 2400 ~ 2483.5 MHz
2.4G ISM Band: 2400 ~ 2483.5 MHz
Bluetooth: PCB Antenna
2.4G ISM Band: PCB Antenna
General Population/Uncontrolled Exposure Portable Device

3 SUMMARY OF TEST RESULT

3.1 Test Standards

No. Identity Document Title
1 47 CFR Part 2.1093 Radiofrequency radiation exposure evaluation: portable devices
2 KDB 447498 D04 v01 KDB 447498 D04 Interim General RF Exposure Guidance v01

4 DEVICE CATEGORY AND LEVELS LIMITS

Portable Derives:

CFR Title 47 §2.1093(b)

(b) For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user.

FCC KDB 447498 Derives:

According with FCC KDB 447498 D04, Appendix B, The SAR-based exemption formula applies for single fixed, mobile, and portable RF sources with available maximum time-averaged power or effective radiated power (ERP), whichever is greater, of less than or equal to the threshold Pth (mW).

This method shall only be used at separation distances from 0.5 cm to 40 cm and at frequencies from 0.3 GHz to 6 GHz (inclusive). The following table shows the power threshold from 5mm to 50mm.

Frequency (MHz) Power Thresholds (mW)
At separation distance of ≤5 mm At separation distance of 10 mm At separation distance of 15 mm At separation distance of 20 mm At separation distance of 25 mm
300 39 mW 65 mW 88 mW 110 mW 129 mW
450 22 mW 67 mW 89 mW 112 mW 90 mW
835 9 mW 44 mW 66 mW 90 mW 66 mW
1900 3 mW 26 mW 44 mW 66 mW 59 mW
2450 3 mW 18 mW 38 mW 59 mW 49 mW
3600 2 mW 10 mW 22 mW 32 mW 25 mW
5800 1 mW 6 mW 14 mW 25 mW 40 mW
Frequency (MHz)
At separation distance of 30 mm At separation distance of 35 mm At separation distance of 40 mm At separation distance of 45 mm At separation distance of 50 mm
300 148 mW 166 mW 184 mW 201 mW 217 mW
450 135 mW 158 mW 180 mW 203 mW 226 mW
835 116 mW 145 mW 175 mW 207 mW 240 mW
1900 92 mW 122 mW 157 mW 195 mW 236 mW
2450 83 mW 111 mW 143 mW 179 mW 219 mW
3600 71 mW 96 mW 125 mW 158 mW 195 mW
5800 58 mW 80 mW 106 mW 136 mW 169 mW

Note:

  1. Maximum power is the source-based time-average power and represents the maximum RF output power including tune-up tolerance among production units.
  2. Per KDB 447498 D04, for larger devices, the test separation distance of adjacent edge configuration is determined by the closest separation between the antenna and the user.
  3. Per KDB 447498 D04, standalone SAR test exclusion threshold is applied; If the distance of the antenna to the user is < 5mm, 5mm is used to determine SAR exclusion threshold.
  4. Per KDB 447498 D04, for separation distances from 0.5 cm to 40 cm and at frequencies from 0.3 GHz to 6 GHz (inclusive), the threshold Pth (mW) is given by Following:

Pth (mW) = 60 / ( (f(GHz)^0.8) * (d/20cm) ) for d ≤ 20cm

Pth (mW) = 60 / ( (f(GHz)^0.8) * (20cm/d) ) for 20cm < d ≤ 40cm

where

x = -log10( (ERP20cm / (1000mW/W)) / (60) )

a. f(GHz) is the RF channel transmit frequency in GHz

b. d is the separation distance (cm), The result is rounded to one decimal place for comparison

c. ERP20cm are determined by:

ERP20cm(mW) = f(x) = { 20*f(GHz) if 0.3GHz < f < 1.5GHz ; 30*f(GHz) if 1.5GHz ≤ f ≤ 6GHz }

5 ASSESSMENT RESULT

5.1 Output Power

Mode Conducted Power (dBm) Antenna Gain (dBi) EIRP (dBm)
Bluetooth (BLE) -2.34 -0.50 -2.84

Note: This report listed the worst case power value, please refer to BL-SZ23A1021-601 report for more details.

Mode Conducted Power (dBm) Antenna Gain (dBi) EIRP (dBm)
2.4G ISM Band (GFSK) -2.35 -0.50 -2.85

Note: This report listed the worst case power value, please refer to BL-SZ23A1021-602 report for more details.

5.2 Tune-up power

Mode Conducted Power Range (dBm) EIRP Range (dBm) ERP Range (dBm)
Bluetooth [-4.00, -2.00] [-4.50, -2.50] [-6.65, -4.65]
2.4G ISM Band [-4.00, -2.00] [-4.50, -2.50] [-6.65, -4.65]

Note1: ERP= EIRP -2.15dB

Note2: According KDB 447498 D04, used the greater of maximum conducted power and ERP to compare with the threshold value Pth.

5.3 RF Exposure Evaluation Result

Mode Distance (mm) Calculation Frequency (MHz) Tune-up limit power (dBm) Tune-up limit power (mW) Threshold Value(mW) Verdict
Bluetooth 5.00 2480 -2.00 0.63 2.72 Compliance
2.4G ISM Band 5.00 2480 -2.00 0.63 2.72 Compliance

5.4 Conclusion

This EUT is deemed to comply with the reference level limits, therefore the basic restrictions are compliant with human exposure limits.

Statement

  1. The laboratory guarantees the scientificity, accuracy and impartiality of the test, and is responsible for all the information in the report, except the information provided by the customer. The customer is responsible for the impact of the information provided on the validity of the results.
  2. The report without China inspection body and laboratory Mandatory Approval (CMA) mark has no effect of proving to the society.
  3. For the report with CNAS mark or A2LA mark, the items marked with "☆" are not within the accredited scope.
  4. This report is invalid if it is altered, without the signature of the testing and approval personnel, or without the "inspection and testing dedicated stamp" or test report stamp.
  5. The test data and results are only valid for the tested samples provided by the customer.
  6. This report shall not be partially reproduced without the written permission of the laboratory.
  7. Any objection shall be raised to the laboratory within 30 days after receiving the report.

--END OF REPORT--

PDF preview unavailable. Download the PDF instead.

90855-RF-Exposure-Info-Ugreen-Group-2aqi5-90855-ex-1-12 钛和检测认证集团股份有限公司

Related Documents

Preview UGREEN MU006 Ergonomic Wireless Mouse FCC Test Report
This document details the FCC compliance test report for the UGREEN MU006 Ergonomic Wireless Mouse, covering technical specifications, test results, and configurations.
Preview UGREEN MU006 Ergonomic Wireless Mouse FCC Test Report
This document details the FCC compliance test results for the UGREEN MU006 Ergonomic Wireless Mouse, covering technical specifications, test procedures, and performance data.
Preview UGREEN MU006 Ergonomic Wireless Mouse User Manual
This user manual provides detailed instructions for the UGREEN MU006 Ergonomic Wireless Mouse, covering setup, connectivity options (2.4G and Bluetooth), DPI adjustment, low battery indication, and product specifications. It also includes important regulatory information such as WEEE, EU Declaration of Conformity, GB Declaration of Conformity, IC Statement, FCC Statement, and warranty information.
Preview UGREEN MU006-90855 Ergonomic Wireless Mouse - Product Overview and EU Declaration of Conformity
Detailed specifications and EU Declaration of Conformity for the UGREEN MU006-90855 Ergonomic Contoured-Shape Design Wireless Mouse, featuring adjustable DPI, silent operation, and compatibility with multiple operating systems.
Preview Ugreen MU006 Wireless Optical Mouse - 2.4GHz/Bluetooth 5.0, 4000 DPI, Black
Discover the Ugreen MU006 wireless optical mouse. Featuring dual connectivity (2.4GHz and Bluetooth 5.0), 4000 DPI resolution, and an ergonomic design in black. Ideal for productivity and everyday use.
Preview Ugreen MU006 Wireless Mouse Internal Photos and FCC ID
Internal photographs of the Ugreen MU006 Ergonomic Wireless Mouse, FCC ID: 2AQI5-MU006, showing the circuit board and components. Includes Anbotek Product Safety testing information.
Preview FCC Test Report for Ugreen Ergonomic Wireless Mouse (Model MU006)
This document is an FCC test report for the Ugreen Ergonomic Wireless Mouse, Model MU006, detailing compliance with FCC Part 15 Subpart C regulations. It includes test results for conducted emissions, radiated emissions, peak output power, bandwidth, frequency separation, hopping channels, dwell time, band edge, and antenna requirements.
Preview Ugreen MU006 Ergonomic Wireless Mouse Technical Specifications and FCC Information
Detailed information and FCC compliance data for the Ugreen MU006 Ergonomic Wireless Mouse, including model number, ratings, and regulatory markings.