User Manual for TechniSat models including: TechniSat, Dimmer
5 Z-Wave Plus This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.
To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance.
10 giu 2020 —
File Info : application/pdf, 21 Pages, 327.11KB
DocumentDocumentUser manual Dimmer Please keep this page with the full device specific key (DSK) in a safe place! It is needed throughout the entire product lifetime 1 Safety warnings ...............................................................................................................3 2 IMPORTANT DISCLAIMER.............................................................................................. 4 3 Key features......................................................................................................................5 4 Overview........................................................................................................................... 6 5 Wiring diagram ................................................................................................................8 6 SmartStart inclusion...................................................................................................... 9 7 Manually adding the device to the Z-Wave network .......................................... 9 8 Removing the device from the Z-Wave network ............................................... 10 9 Factory Default Reset ................................................................................................. 10 10 Configuration................................................................................................................ 11 11 Supported Association Groups................................................................................13 12 Basic Command Class ............................................................................................... 14 13 Notification Command Class ....................................................................................15 14 Supported Command Classes documentation...................................................15 15 Central Scene................................................................................................................17 16 Firmware update.........................................................................................................18 17 Technical Data ..............................................................................................................19 2 1 Safety warnings INSTALLATION 1. To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance. 2. Be aware that even if the circuit breaker is off, some voltage may remain in the wires -- before proceeding with the installation, be sure no voltage is present in the wiring. 3. Take extra precautions to avoid accidentally turning on the device during installation. 4. Connect the device according to the wiring diagram. Danger of electrocution! Installation of this device requires a great degree of skill and may be performed only by a licensed and qualified electrician. Please keep in mind that even when the device is turned off, voltage may still be present in the device's terminals. 3 2 IMPORTANT DISCLAIMER Wireless communication is not always 100% reliable. This device should not be used in situations in which life and/or valuables are solely dependent on its functioning. If the device is not recognized by your gateway (hub) or shows up incorrectly, you may need to change the device type manually and make sure your gateway (hub) supports Z-Wave Plus devices. WARNING Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal free of charge. Z-Wave This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. 4 Z-Wave Plus This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions. 3 Key features The Dimmer controls the on/off and dimming function for one electrical device. It measures power consumption of the connected device. - In-wall mounted light dimmer - Z-Wave Plus - Security S2 - SmartStart - compatible with German market wall switch product lines - Overload protection 5 4 Overview Front LED T1 T T2 LED status-LED T1 short press = on / hold = dim up (brighter) T2 short press = off / hold = dim down (darker) 6 Back L Live lead Switched output with dim function to electrical device (T1 - T2) N Neutral lead S Extension input (can detect a live lead) 7 5 Wiring diagram N L S push-button switch 8 N L S toggle switch 6 SmartStart inclusion SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. 1. The Z-Wave QR-Code is located on the back of the product. 2. Please follow your SmartStart enabled Z-Wave gateway`s manual, on how to use SmartStart inclusion. 3. Install the TechniSat Dimmer. 4. After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker 5. The TechniSat Dimmer will be added to your Z-Wave network within 10 minutes after re-enabling electrical power. 7 Manually adding the device to the Z-Wave network 1. Install the TechniSat Dimmer. 2. After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker. 3. Start the Z-Wave device add mode on your Z-Wave gateway, according to the gateway`s manual. 4. Press position T1 3x within 1 second. 9 5. The red status LED is on while the device is added to the Z-Wave network. 6. The green LED is on for 5 seconds after successfully adding the device. 8 Removing the device from the Z-Wave network 1. Start the Z-Wave device remove mode on your Z-Wave gateway, according to the gateway`s manual. 2. Press and hold position T1 for more than 10 seconds. 3. The red status LED is on while the device is removed from the Z-Wave network. 4. The green LED is on for 5 seconds after successfully removing the device. 9 Factory Default Reset Use this procedure only when the network primary controller is missing or otherwise inoperable. 1. Press and hold position T2 for more than 20 seconds. 2. The LED will alternately flash red and green for 5 seconds after a successful reset. 10 10 Configuration Parameter 1 2 Description Size (Bytes) Enable/Disable 1 Central scene notifications for 2x-5x press Interval of current 2 wattage meter reports in 10 seconds Value 0 - disable 1 - enable 0 - disable unsolicited reports Default 1 3 (30s) 1 ... 8640 (30 seconds - 1 day) 3 Interval of active 2 0 - disable 60 energy meter reports unsolicited (1hour) in minutes reports 10 ... 30240 (10 minutes - 3 weeks) 11 Parameter Description 4 Operation mode of button T Size (Bytes) 1 Value 0 - T1 turns output L1 on, T2 turn output L1 off Default 0 1 - T1 & T2 toggle output L1 5 Configuration 1 0 - toggle 0 of switch type switch connected to extension connector 1 - push button S switch 6 Central Scene 1 1 - map S to 1 mapping of extension central scene input S of T1 2 - map S to central scene of T2 3- map S to own central scene 12 Parameter Description 7 Dimming curve selection Size (Bytes) 1 Value 0 - dimming curve 1 1 - dimming curve 2 11 Supported Association Groups Default 0 ID Name Max group members CC-Commands 1 Lifeline 1 - Device Reset Locally Notification - Central Scene notification - Meter Report - Multilevel Switch Report - Notification Report 2 Switch 10 State - Basic Set 13 12 Basic Command Class This device controls members of association group 2 with Basic Command Class Set commands. The set commands mirror the device`s state. When the device is set to a specific multilevel value, the same value is send as a Basic Set to members in association group 2. If the target value is unspecific, because the up or down buttons are held (the dimmer will dim until the button is released or min/max brightness is reached), a Basic Set with the min/max dimming value corresponding with the current direction of dimming (either 0x01 or 0x63)) will be send to members in association group 2. If dimming is stopped before min/max brightness is reached, an additional Basic Set command with the current dimming value where the dimming was stopped, will be send to members in association group 2. 14 13 Notification Command Class Notification Type Power Management (0x08) Notification Event Idle (0x00) Overload detected (0x08) Description No event detected / event cleared The maximum resistive load on L1 has been exceeded 14 Supported Command Classes documentation Command Class Association Association Group Information Basic Central Scene Configuration Device Reset Locally Firmware Update Meta Data Manufacturer Specific Version Required Security Class 2 highest granted 1 highest granted 2 highest granted 3 highest granted 1 highest granted 1 highest granted 4 highest granted 2 highest granted 15 Command Class Meter Multilevel Switch Notification Powerlevel Security 0 Security 2 Supervision Transport Service Version Z-Wave Plus Info Version Required Security Class 4 highest granted 4 highest granted 8 highest granted 1 highest granted 1 none 1 none 1 none 2 none 3 highest granted 2 none 16 15 Central Scene The Dimmer can send central scene activation notifications to a Z-Wave gateway. Pressing the respective button position multiple times, will send the corresponding scene number: Button position T1 Scene number 1 T2 S (switch connected to extension input) 2 1 or 2 or 3 depending on configuration parameter 6 The following Z-Wave key attributes are available for all scenes: Button position pressed Z-Wave key attribute two times Key Pressed 2 times three times Key Pressed 3 times four times Key Pressed 4 times five times Key Pressed 5 times 17 16 Firmware update This device supports firmware update via Z-Wave. For enhanced security, the device requires a manual confirmation, before an update of the device`s firmware can be initated. To perform a firmware update follow these steps: 1. Follow your Z-Wave gateway`s manual, on how to update the firmware of a Z-Wave device. 2. From your gateway issue a Z-Wave request to get the current firmware version of the device to be updated. 3. When the request has been received, your device`s LED will glow red for 10 seconds. 4. While the LED glows red, press T1 or T2 to allow a firmware update - the LED will now glow green for 10 seconds. 5. While the LED glows green, start the device`s firmware update from your gateway. 18 17 Technical Data Product Key Features supply voltage line frequency rated load current of output (resistive load) output circuit power - minimum load - resistive load - capacitive load - inductive load power consumption (without load) In-wall mounted binary switch control Z-Wave Plus Security S2 SmartStart compatible with German market wall switch product lines Overload protection 230 VAC +/- 10% 50Hz +/- 10% 0.87 A 1 W 200 W 200 VA 200 VA (cos phi > 0,95 (0 < phi < 18°) in case of transformer) < 0.5 W 19 extension input S supply voltage 230 VAC +/- 10% power consumption: < 35 mW operation altitude < 2000 m sea level IEC protection class II accuracy of power measurement >= 100W: +/- 3% Status LED Red status LED is on while adding the device Z-Wave frequency and transmission power Ambient Conditions Operational Ambient Conditions Warehousing & Transport: Green LED is on for 5 s after successfully adding the device 868,42MHz 4dBm Temperature: +5°C to +35°C Humidity: 10 % to 75% RH IP Code: IP20 Temperature: -20°C to +60°C Humidity: 5 % to 90% RH non condensing 20 Subject to technical changes and errors. Subject to change for amendments and printing errors. Last updated: 02/20 Duplication and reproduction only with the publisher`s approval. TechniSat is a registered trademark of: TechniSat Digital GmbH PO box 560 54541 Daun (Germany) www.technisat.com Technical Hotline Mon. - Fri. 8:00 - 18:00 03925/9220 1800 Caution! If you encounter a problem with this equipment, please contact our Technical Hotline immediately. Z-Wave and Z-Wave Plus are registered trademarks of Silicon Laboratories and its subsidiaries in the United States and other countries. 07022020ORV1.6 21Adobe PDF Library 15.0 Adobe InDesign 15.0 (Windows)