User Guide for Edge-core models including: AS4630-54PE 48-Port Ethernet Switch, AS4630-54PE, 48-Port Ethernet Switch, Ethernet Switch, Switch

AS4630-54PE Quick Start Guide

Edgecore Networks Corporation

Download

EPS202 (AS4630-54PE) Quick Start Guide R04 – Edgecore Networks

EPS202 – Edgecore Networks


File Info : application/pdf, 9 Pages, 940.09KB

PDF preview unavailable. Download the PDF instead.

?wpdmdl=1082&refresh=662d369f1966b1714239135
Quick Start Guide
48-Port Ethernet Switch
AS4630-54PE
Package Contents

www.edge-core.com

1

2

3

4

5

1. AS4630-54PE Ethernet Switch
2. Rack mounting kit--2 front-post brackets, 2 rear-post brackets, and screw kit
3. 2 x Power cord

4. Console cable--RJ-45 to D-Sub
5. Documentation--Quick Start Guide (this document) and Safety and Regulatory Information

Overview

1

4

2

3

5

1. 1 x USB port 2. 1 x Management port 3. 1 x Serial console port 4. System buttons/LEDs 5. 48 x RJ-45 1G PoE ports

7

8

9

6
6. 4 x SFP28 10G/25G ports 7. 2 x QSFP28 40G/100G uplink or stacking ports 8. 3 x Fan trays 9. 2 x AC PSUs

System Buttons/LEDs

Port/FRU LEDs

STK M/S button Reset button System LED: Green (OK), Amber (fault) PRI LED: Green (primary unit), Amber (secondary unit) PSU LEDs: Green (OK), Amber (fault) STK LEDs: Green (stacking ports active) FAN LED: Green (OK), Amber (fault) PoE LED: Green (OK), Amber (High PoE load)
FRU Replacement

RJ-45 Port LEDs: Green (link), Amber (link with PoE), Blinking (activity) SFP28 Port LEDs: White (25G), Green (10G), Blinking (activity) QSFP28 Port LEDs: White (100G), Green (40G link), Blinking (activity) PSU Status LED: Green (OK), Red (fault or fan failure) Fan Tray Status LED: Green (OK), Red (fault)

PSU Replacement 1. Remove the power cord.
2. Press the release latch and remove the PSU.
3. Install replacement PSU with matching airflow direction.

Fan Tray Replacement 1. Loosen the fan tray screw.
2. Remove fan tray from the chassis.
3. Install replacement fan with matching airflow direction.



­ 1 ­

E022023-MR-R04 150200002243A

Quick Start Guide

Installation

Warning: For a safe and reliable installation, use only the accessories and screws provided with the device. Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty. Avertissement: Pour une installation sûre et fiable, utilisez uniquement les accessoires et les vis fournies avec l'appareil. L'utilisation d'autres accessoires et vis pourrait endommager l'appareil. Les dommages causés par l'utilisation d'accessoires non approuvés ne sont pas couverts par la garantie. Caution: The device includes plug-in power supply (PSU) and fan tray modules that are installed into its chassis. Make sure all installed modules have a matching airflow direction. Attention: Le appareil comprend des modules d'alimentation et de modules de ventilation installés dans son châssis. Assurez-vous que tous les modules installés ont une direction d'air adaptée. Note: The device has the Open Network Install Environment (ONIE) software installer preloaded on the switch, but no switch software image. Information about compatible switch software can be found at www.edge-core.com.
1 Mount the Switch

Optional Slide-Rail Installation An optional slide-rail kit is available for rack installation. Follow the installation procedure provided with the kit.
2 Connect Power
AC Power Install two AC PSUs and connect them to an AC power source.
3 Verify Switch Power
Check the PSU LEDs The PSU1/PSU2 LEDs should be on green when operating normally.

1. Attach the Brackets Use the included screws to attach the front- and rear-post brackets.

4 Perform Initial System Boot
1. ONIE Installer Software If the network operating system (NOS) installer is located on a network server, first connect the RJ-45 Management (Mgmt) port to the network using 100-ohm Category 5, 5e or better twisted-pair cable. (Not required if the NOS installer is located on attached storage.)
2. Boot the Switch Wait for the ONIE software to locate and execute the NOS installer, and then wait for the installer to load the NOS software image. Subsequent switch boots will bypass ONIE and directly run the NOS software.
Note: For switches with ONIE software pre-loaded, refer to the network operating system (NOS) installer and NOS documentation for details on software options and set up for ONIE.

2. Mount the Switch Mount the switch in the rack and secure it with rack screws.

3. Lock the Rear-Post Brackets Use the included screws to lock the position of the rear-post brackets.
­ 2 ­

5 Make Network Connections
1. RJ-45 ports Connect 100-ohm Category 5, 5e or better twisted-pair cable. 2. SFP+/SFP28 slots First install SFP+/SFP28 transceivers and then connect fiber optic cabling to the transceiver ports.
6 (Optional) Make Stack Connections

Quick Start Guide

Hardware Specifications

Switch Chassis

Size (WxDxH) 438 x 442 x 43.7 mm (17.24 x 17.40 x 1.72 in)

Weight

7.67 kg (16.91 lb), with two installed PSUs

Temperature Operating: 0° C to 45° C (32° F to 113° F) Storage: -40° C to 70° C (-40° F to 158° F)

Humidity

Operating: 5% to 90% (non-condensing)

Power

1800 Watts max.

Consumption

System Input Power Rating

AC Input

100-120 Vac, 50-60 Hz, 12 A max. 200-240 Vac, 50-60 Hz, 7.5 A max.

Regulatory Compliances

Emissions

EN 55032:2015+AC:2016, Class A EN 61000-3-2:2014, Class A EN 61000-3-3:2013 FCC Class A VCCI Class A BSMI Class A, CNS 13438

Immunity

EN 55024:2010+A1:2015 EN 55035:2017 IEC 61000-4-2/3/4/5/6/8/11

Safety

UL (UL 62368-1 & CSA C22.2 No. 62368-1) CB (IEC/EN 60950-1, IEC/EN 62368-1) BSMI, CNS 14336-1

Taiwan RoHS CNS 15663

1. Connect the top device Plug one end of a DAC cable in the bottom QSFP28 port of the top unit.
2. Connect the next device Plug the other end of the DAC cable into the top QSFP28 port of the next unit.
3. Repeat Repeat for each unit in the stack.
4. (Optional) Connect the top and bottom devices Plug one end of a DAC cable into the bottom QSFP28 port on the bottom unit and the other end into the top QSFP28 port on the top unit.
5. Reboot Reboot each switch in the stack to start the stack operations.
Note: Stacking support is dependent on the switch software. For stacking support information, refer to the NOS software documentation.

­ 3 ­


48-
AS4630-54PE



www.edge-core.com

1

2

1. AS4630-54PE  2.  --2  2  3. 2 

3

4

5

4.  --RJ-45  D-Sub 5.  --  



1

4

2

3

5

1. 1 x USB 

2. 1 x 

3. 1 x 

4.  /LED 

5. 48 x RJ-45 1G PoE 

/LED

7

8

9

6
6. 4 x SFP28 10G/25G  7. 2 x QSFP28 40G/100G  8. 3 x  9. 2 x  PSU

/FRU LED

STK M/S    LED   PRI LED   PSU LED    STK LED    LED    PoE LED    PoE  )
FRU

RJ-45  LED  :    PoE)   SFP28  LED  :  (25G) (10G)   QSFP28  LED  :  (100G) (40G)   PSU  LED     :   

PSU  1.  2.  PSU
3.  PSU

 1. 
2. 
3.  



­ 4 ­

E022023-MR-R04 150200002243A




 

2 

 PSU 
 (ONIE) www.edge-core.com

1 



  PSU
3 
 PSU LED   PSU1/PSU2 LED 

1.  

4 
1.ONIE   (NOS)  100  5 5e  RJ-45  (Mgmt)  NOS 
2.   ONIE  NOS   NOS  ONIE  NOS 

2.  

 ONIE   ONIE  NOS NOS 
5 

3.  
  

1.RJ-45   100-ohm 5  5e 
2.SFP+/SFP28   SFP+/SFP28  

­ 5 ­



6 
1.   DAC  QSFP28  2.   DAC  QSFP28  3.   4.   DAC  QSFP28   QSFP28  5.  
  NOS 




  x  438 x 442 x 43.7 mm17.24 x 17.40 x 1.72  x 

 

7.67 kg (16.91 lb) PSU 0° C  45° C 32° F  113° F -40° C  70° C -40° F  158° F



5%  90% 



1800 Watts max.





100-120 Vac, 50-60 Hz, 12 A max. 200-240 Vac, 50-60 Hz, 7.5 A max.

 
   RoHS

EN 55032:2015+AC:2016, Class A EN 61000-3-2:2014, Class A EN 61000-3-3:2013 FCC Class A VCCI Class A BSMI Class A, CNS 13438 EN 55024:2010+A1:2015 EN 55035:2017 IEC 61000-4-2/3/4/5/6/8/11 UL (UL 62368-1 & CSA C22.2 No. 62368-1) CB (IEC/EN 60950-1, IEC/EN 62368-1) BSMI, CNS 14336-1 CNS 15663

­ 6 ­


48 
AS4630-54PE



www.edge-core.com

1

2

1. AS4630-54PE  2.  --2 2  3. 2 x 

3

4

5

4.  Console Cable --RJ-45  D-Sub 5.  --  



1

4

2

3

5

1. 1 x USB 

2. 1 x 

3. 1 x 

4.  LED

5. 48 x RJ-45 1G PoE 

LED

7

8

9

6
6. 4 x SFP28 10G/25G  7. 2 x QSFP28 40G/100G  8. 3 x 
9. 2 x AC PSU

/FRU LEDs

STK M/S    LED   PRI LED   PSU LED   STK LED   LED (OK)  PoE LED   PoE 
 FRU

RJ-45  LED   PoE   SFP28  LED (25G) (10G)  QSFP28  LED (100G) 40G    PSU  LED (OK)   LED (OK) 

 PSU 1.  2.  PSU
3.  PSU

 1. 
2. 
3.  



­ 7 ­

E022023-MR-R04 150200002243A



    (PSU)   (ONIE)   www.edge-core.com

2 

1 

AC   AC PSU  AC 



3 
 PSU LEDs PSU1  PSU2 LED 

1.  
2.  

4 
1.ONIE   NOS 100ohm  5 5e  RJ-45  Mgmt NOS  
2.   ONIE  NOS  NOS  ONIE NOS 
 ONIE   (NOS)  NOS  ONIE  
5 

3.  
 

1.RJ-45   100-ohm Category 55e 
2.SFP+/SFP28   SFP+/SFP28 

­ 8 ­



6 
1.   DAC  QSFP28  2.   DAC  QSFP28  3.   4.   DAC  QSFP28   QSFP28  5.  
  NOS 





 x  438 x 442 x 43.7 mm17.24 x 17.40 x 1.72  x 



7.67 kg (16.91 lb) PSU



0° C  45° C 32° F  113° F -40° C  70° C -40° F  158° F



5%  90% 



 1800 



AC 

100-120 Vac50-60 Hz 12 A 200-240 Vac50-60 Hz 7.5 A

 

EN 55032:2015+AC:2016, Class A EN 61000-3-2:2014, Class A EN 61000-3-3:2013 FCC Class A VCCI Class A BSMI Class A, CNS 13438



EN 55024:2010+A1:2015 EN 55035:2017 IEC 61000-4-2/3/4/5/6/8/11



UL (UL 62368-1 & CSA C22.2 No. 62368-1) CB (IEC/EN 60950-1, IEC/EN 62368-1) BSMI, CNS 14336-1

 CNS 15663  RoHS

­ 9 ­



References

Adobe PDF Library 15.0