User Guide for ideal models including: 1000kW, Evojet 1000kW Condensing Pressure Jet Boilers, Evojet 1000kW, Condensing Pressure Jet Boilers, Pressure Jet Boilers, Jet Boilers, Boilers
Product Guides, Manuals and | Ideal Commercial
File Info : application/pdf, 4 Pages, 472.24KB
DocumentDocumentEVOJET 1000kW Pressure jet Floor standing BIM Dual fuel Part L Features and specification The Evojet condensing range of pressure jet boilers are available in 14 models with outputs from 150-3000kW. Floor standing boilers for applications in either single or multiple configurations. · Up to 109.3% part load efficiency · Designed to operate up to 40°C T providing minimum flow rates are achieved · Triple flue pass for high operating efficiencies · Multiple burner options available (see page 3 for details) · Dedicated low temp return · Stainless steel heat exchanger · Modulation via 0-10 volt BMS, or RWF controller DIMENSIONS AND CLEARANCES BOILER 1000 DIM A 1080 DIM B 2810 DIM C 1910 The following minimum clearances must be maintained for operation and servicing: FRONT: BURNER LENGTH + 600MM (FOR ACCESS / MAINTENANCE) BOILER LENGTH (FOR CLEANING) REAR: 1000mm (Min) TOP: 1000mm (Min) SIDES: 1000mm (Min) 1155 14 17 16 9 12 11 5 13 7 3 8 1 1 10 4 20 20 6 2 2 18 19 20 CONTROL PANEL 80 120 100 60 40 20 0 40 60 20 80 0 100 120 HORIZONTAL VERTICAL BOILER ASSEMBLY EXPLODED VIEW KEY 1. Boiler frame 2. Side Panel 3. Side Panel 4. Rear Panel 5. Rear Panel 6. Central side panel 7. Central side panel 8. Top cross beams 9. Top rear panel 10. Bottom rear bracket 11. Bottom rear panel 12. Bottom rear panel 13. Front top panel 14. Top panel 15. Top panel 16. Top panel 17. Top panel 18. Front trim panel 19. Front trim panel 20. Control panel idealheating.com | 01482 492251 | commercial@idealheating.com Ideal Heating, National Avenue, Kingston upon Hull, East Yorkshire, HU5 4JN EVOJET 1000kW TECHNICAL SPECIFICATIONS GENERAL Dry Weight Boiler Dimensions Boiler Clearances KG mm mm Full load efficiency NCV (80/60) Part load efficiency NCV (50/30) Seasonal efficiency GCV (Part L vol.2 2022) Min gas pressure (Nat Gas) % % % mbar 2085 1910 (H) x 1080 (W) x 2810 (D) Front (maintain): Burner Length + 600mm Front (clean): Boiler Length Left Side: 1000 Right Side: 1000 Rear: 1000 Top: 1000 98.2 108.7 96.0 20* Burner and Gas Train selections for Natural Gas applications are based on standard design requirements (as stated in IGE/UP/2) of 20mbar gas pressure available at the appliance under max flow conditions. If this pressure is not available, or the available gas pressure is higher, or for alternative fuel types - please consult your sales contact for alternative matching. HYDRAULICS Pressure drop T 10°C Pressure drop T 20°C Nominal flow rate t 10°c Nominal flow rate t 20°c Min flow rate Min flow temperature Max flow temperature High limit set point Max working pressure Condensate connection Flow connection Return connection (lt) Return connection (ht) Safety valve connection Water content mbar mbar l/sec l/sec l/sec °C °C °C bar inches DN DN DN DN / Ø" litres 121.5 30.6 23.89 11.95 3.17 30 95 110 6 1.25 DN125 PN6 DN125 PN6 DN80 PN6 DN80 PN6 1395 BURNER (Low NOx) Fuel Fuel consumption (Nat Gas) Boiler output (mean 70°C) Boiler output (mean 40°C) Boiler input (GCV) NOX (GCV EN676) NOX (at 3% 02 dry flue gas reference) Furnace pressure Furnace volume Min burner length Burner hole diameter (Type G20) m³/h kW kW kW mg/kWh mg/Nm³ mbar dm³ mm mm Natural Gas 103.0 982.0 1065.0 1110.0 63 68 6.3 845.0 200 235 FLUE/AIR INLET Flue size Max flue gas mass airflow rate Min-max flue gas temperature ** Dependent on return temperature. mm kg/sec °C 350 0.4540 <45 - 75** ELECTRICAL (PRIMETECH CONTROL PANEL) Electrical supply Current (Max no pump) Power consumption Fuse rating Insulation class IP amp watt amp 230 ± 10% 50Hz 1 Ph 6.3 250 6.3T X4D CONTROL/BOILER/BURNER OPERATION 0-10V DC BMS or Siemens RWF High limit protection Boiler temperature gauge Control thermostat sensor Safety thermostat sensor Two stage thermostat Optional Standard Standard Standard Standard Yes BURNER MATCHING OPTIONS NG LPG Pre-mix Oil Dual fuel Yes Yes* Yes Yes No Modulating and Low NOx options available; please contact us for full details. Oil burners would be subject to confirmation that the fuel supply was a suitable type / grade. * Burner matching for LPG operation by special request. GET A QUOTE idealheating.com | 01482 492251 | commercial@idealheating.com EVOJET 1000kW SUGGESTED ENGINEERING SPECIFICATION The Suggested Engineering Specification is wording designed for specifiers to copy and paste into their specifications to ensure inclusion of Ideal Heating commercial boilers. OVERVIEW The boiler must be a fully automatically controlled, floor standing condensing boiler with a triple flue pass stainless steel heat exchanger. While they are designed primarily for central heating purposes, in conjunction with a suitable storage cylinder they can also be used to produce domestic hot water on an indirect fully pumped sealed water system. DIMENSIONS The condensing boiler must fit within maximum permitted floor space of 0.97m² (150 and 210kW models)/1.23m² (270 and 350kW models)/1.47m² (450 and 900kW models)/2.03m² (800 and 1000kW models)/2.40m² (1250kW model)/2.67m² (1450kW model)/6.34m² (1750kW model)/7.04m² (2100kW model)/8.19m² (2700kW) model/9.00m² (3000kW model). MOUNTING / POSITIONING The condensing boilers will be floor standing. EFFICIENCY All parts that come into contact with the combustion gases are made from titanium stabilised stainless steel to ensure maximum resistance to the corrosive action of acid condensation. The boiler must incorporate two return water connections to facilitate multiple applications e.g. CH & DHW and enables the optimum operating efficiency to be achieved. The boilers must be designed to operate with Natural Gas, LPG or Oil (delete as required) using pressure-jet or premixed burners. The burner specification will enable the choice of 2-stage, Modulating, Low NOx and Ultra Low NOx operation. The condensing boilers are capable of high seasonal efficiencies with a minimum requirement of 95.8% (Part L Vol.2 2022) and low NOx emissions between 43 - 65mg/kWh (47 - 70mg/Nm³) depending on boiler model, using Low NOx Natural Gas burner. APPROVALS The manufacturer must be ISO 9001 accredited SPECIFICATION The boiler must be capable of the below flow rates: CONTROLS The boiler control options must be selected at the time of purchase: · Two stage burner · Modulating burner · BMS 0-10V · Oil & dual fuel The boiler must include control features enabling set point adjustment, heating circuit control of one constant temperature, one variable temperature and one DHW circuit and safety lock out parameters including fault diagnosis for both boiler and external components such as sensors or pumps. Boiler capabilities must include, with the use of external components, frost protection, weather or room compensation and system pump control. FLUE The condensing boilers must be suitable for use with an open flued application in B23 configuration. The B23P configuration can only be used with a premix gas burner. HYDRAULIC BOILER MODEL 150 210 270 350 450 600 800 1000 1250 1450 1750 2100 2600 3000 MIN FLOW (L/H) 1,700 2,400 3,100 4,000 5,100 6,800 9,100 11,400 14,200 16,500 20,400 24,500 30,400 35,000 The condensing boiler must be suitable for connection to a fully pumped sealed water system. All hydraulic connections including flow return and condensate drain must be located on the bottom or rear of the boiler. The boiler must have a maximum operating pressure of 6 bar and be suitable for heating and indirect hot water systems. WARRANTY The boiler must be available with a 2 year warranty. Please note that the above information is correct at time of publication. Ideal Heating pursues a policy of continuous improvement in design and performance of its products and reserves the right to vary specification without notice. IHC_Evojet_Spec_Sheet_1000kW GET A QUOTE idealheating.com | 01482 492251 | commercial@idealheating.com