HIKVISION DS-PS1-E-WA Wireless External Sounder Quick Start Guide
This guide provides essential information for the installation and operation of the HIKVISION DS-PS1-E-WA Wireless External Sounder.
Product Overview and Standards
Brand: HIKVISION
Model: DS-PS1-E-WA Wireless External Sounder
Standards Compliance:
- EN 50131-1:2006+A2:2017
- EN 50131-4:2019
- EN 50131-6:2017
- EN 50131-5-3:2017
- Security Grade (SG): 2
- Environmental Class (EC): IV
Certified by Telefication.
Appearance and Components
The sounder unit features the following components:
- 1. Strobe Light
- 2. Water-Proof Transparency Cover
- 3. Tamper Switch (Front and rear tamper-proof)
- 4. Buzzer
- 5. Battery Connector
- 6. Power Switch
- 7. 12 VDC Power Terminal
- 8. Power Cable Knock Out
- 9. Gradienter (for level installation)
- 10. Indicator Light
Power Options
The device can be powered by either batteries or a 12 VDC power supply.
Battery Power
Uses 4 x CR123A batteries.
12 VDC Power
Connects via the 12 VDC power terminal.
Note: For 12 VDC power supply, route cables before installation.
Installation and Enrollment
Installation Steps:
- Check signal strength: Ensure adequate wireless signal before mounting.
- Mounting: Install the device on a non-flammable surface, such as a concrete wall, using wall mounting. Ensure the equipment remains secure and undamaged after installation. The additional force for mounting should be equal to three times the weight of the equipment but not less than 50N.
Enrollment Process:
The enrollment process typically involves using a mobile application:
- Scan the QR code on the device to download the user manual or access setup information.
- Follow the on-screen instructions in the mobile app to enroll the sounder.
A signal strength test is performed during setup, indicated by the device's indicator light.
Specifications
Parameter | Details |
---|---|
RF Frequency | 915 MHz |
RF Method | Two-way communication |
RF Distance | 1.6 KM |
Indicator | Red/Green |
Strobe Light | Red/Blue (white on the board) |
Power Supply | Battery (default) or 12 VDC |
Quiescent Current | 40uA |
Power Consumption (Battery) | Max. 3 V/4A (alerts at volume level 3) |
Power Consumption (12 VDC) | Max. 12 V/1.3A (alerts at volume level 3) |
Low Battery Cut Off | 2.45 V |
Voltage Range (Battery) | Fully charged (new) to 2.45V DC |
Battery Life Span | 4 CR123A, 3 years (triggered every two weeks, alerting 90s each time) |
Interface | Power switch, Tamper switch |
Buzzer | Piezo Decibel: 102 dB |
Max. Sound Duration | 15 min (900s) |
Operation Temperature | -25 °C to 60 °C (-13 °F to 140 °F) |
Operation Humidity | 10% to 90% |
Material | PC+ABS |
Dimension (W x H x D) | 190 x 200 x 47.3 mm (7.48" x 7.87" x 1.86") |
Weight | 606.5g |
Protection Level | IP65 |
Installation | Wall mounting |
Safety and Compliance Information
Battery Safety:
- Do not swallow the battery.
- Keep new and used batteries away from children.
- Seek immediate medical attention if batteries are swallowed or placed inside any part of the body.
- Risk of explosion if battery is replaced by an incorrect type.
- Dispose of used batteries according to instructions and local regulations.
- Ensure the battery compartment closes securely.
- Install batteries according to polarity marks; incorrect polarity may damage the device.
- Specific cautions regarding fire, crushing, extreme temperatures, and low pressure are noted for battery safety.
Installation Safety:
- Ensure mounting is secure and the equipment is not damaged after installation.
- Install on non-flammable surfaces like concrete walls.
FCC Information:
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) it may not cause harmful interference, and (2) it must accept any interference received. This equipment complies with FCC radiation exposure limits for an uncontrolled environment, requiring a minimum distance of 20cm between the radiator and the body.
CE Compliance:
The product is marked with "CE" and complies with applicable harmonized European standards under the RE Directive 2014/53/EU, EMC Directive 2014/30/EU, and RoHS Directive 2011/65/EU.
WEEE and Battery Directives:
Information regarding proper disposal and recycling according to WEEE (2012/19/EU) and Battery (2006/66/EC) directives is provided, directing users to local suppliers or designated collection points.
About this Manual
This manual provides instructions for using and managing the product. Information is subject to change without notice. The latest version can be found at the Hikvision website: https://www.hikvision.com/.
Use this manual with guidance from trained professionals.
Disclaimer
Hikvision provides the product "as is" without warranties. The use of the product is at the user's own risk. Hikvision is not liable for damages arising from product use, business interruption, data loss, or security risks related to internet usage. Users are responsible for complying with applicable laws and respecting third-party rights. Prohibited end-uses include the development of weapons of mass destruction or support for human rights abuses.