User Manual for Winsen models including: ZE03, Electro Chemical Gas Sensor, Chemical Gas Sensor, Electro Gas Sensor, Gas Sensor, Sensor, ZE03

Guoshuang

Electrochemical Gas Detection Module ... - Winsen Sensor

20 juin 2022 — ZE03 is a general-purpose and high-performance electrochemical module. It uses three electrodes, electrochemical gas sensor and high-performance ...

16 juin 2022 — ZE03 is a general-purpose and high-performance electrochemical module. It uses three electrodes, electrochemical gas sensor and high-performance ...


File Info : application/pdf, 8 Pages, 322.05KB

PDF preview unavailable. Download the PDF instead.

ze03-electrochemical-module-manualv2 8(5)
Zhengzhou Winsen Electronics Technology Co.,Ltd

www.winsen-sensor.com

Electrochemical Gas Detection Module User's Manual V2.8 ModelZE03
Valid from: 2021-08-04
Zhengzhou Winsen Electronics Technology Co., Ltd

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email: sales@winsensor.com

Leading gas sensing solutions supplier in China!

Zhengzhou Winsen Electronics Technology Co.,Ltd

www.winsen-sensor.com

Statement

This manual copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can't spread through electronic, copying, record ways.

Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, change the components inside of the sensor, we shall not be responsible for the loss.

The specific such as color, appearance, sizes ...etc., please in kind prevail. We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users' comments on optimized using way are welcome. Please keep the manual properly, in order to get help if you have questions during the usage in the future.

Zhengzhou Winsen Electronics Technology CO., LTD

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email: sales@winsensor.com

Leading gas sensing solutions supplier in China!

Zhengzhou Winsen Electronics Technology Co.,Ltd

www.winsen-sensor.com

Electrochemical Detection Module ZE03

ZE03 is a general-purpose and high-performance electrochemical module. It uses three electrodes, electrochemical gas sensor and high-performance micro-processor. By installing different gas sensor, the module could detect relevant gas. It is with built-in temperature sensor to make temperature compensation, which makes it could detect the gas concentration accurately. It has the digital output and analog voltage output at the same time which facilities the usage and calibration and shorten the development period. It is a combination of mature electrochemical detection principle and sophisticated circuit design, to meet customers' different detection needs.

Features

High sensitivity & resolution Low power consumption UART and analog voltage output Good stability and excellent anti-interference ability

Main Application
Portable and fixed gas detector, various gas detection equipment and occasion.

Technical Parameters

Model No.

ZE03

Target Gas

CO, O2, NH3, H2S, NO2, O3, SO2, CL2, HF, H2, PH3, HCL etc

Measurement Range Refer stable 2.(can be customized also)

Working Voltage

DC 5±0.1V

Working Current

 5 mA

Output Data Working Life

UART Output (TTL electrical level,3V)
Analog Voltage (refer stable2. for sensor original amplifying signal)
2 years

Operating Environment

Temp.: -2050
Humidity.: 15%-90RH (no condensation)

Storage Environment Size

Temp.: -2050 Hum.: 15%RH-90RH
ø23.5mm*24.5mm

Fig1. Structure( tolerance ±0.25mm )

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email: sales@winsensor.com

Leading gas sensing solutions supplier in China!

Zhengzhou Winsen Electronics Technology Co.,Ltd

www.winsen-sensor.com

Fig2. Socket size for module (mm )
Detection range and signal output Table 2

Detection gas Detection range

CO (0-1000)ppm

O2 (0-25) %VOL

NH3 (0-100)ppm

H2S (0-100)ppm

Resolution
VO Voltage output Range
Response Time(T90)

1ppm (0.6-3) V
30S

0.1 %VOL (1.5-0) V
15S

1ppm 0.6-3) V 150S

1ppm 0.6-3) V
30S

SO2 (0-20) ppm
0.1ppm (0.6-3) V
30S

Detection gas Detection range
Resolution VO Voltage output
Range Response Time(T90)

H2 (0-1000)ppm
1ppm (0.6-3) V 120S

PH3 (0-1000)ppm
0.1ppm (0.6-3) V
30S

NO2 (0-20) ppm
0.1ppm 2-0) V
30S

O3 (0-10) ppm
0.1ppm (2-0) V 120S

CL2 (0-20) ppm
0.1ppm (2-0) V 60S

DG01 (0-50)ppm 0.01ppm
(0.6-3)V 120S
HCL (0-10)ppm
0.1ppm (2-0) V 60S

VOC (0-100)ppm
0.1ppm (0.6-3) V 120S
HF (0-10)ppm
0.1ppm (2-0) V 60S

Detection gas Detection range

C2H4 (0-100)ppm

ETO (0-100)ppm

CH2O (0-50)ppm

Resolution

0.1ppm

0.1ppm

0.1ppm

VO Voltage output Range

(0.6-3)V

(0.6-3)V

(0.6-3)V

Response Time(T90)

30S

120S

30S

Left side value of detection range (zero point) is corresponding to left side value of voltage output range ,BUT right side value of detection(max detection value ) is NOT corresponding to the right side value of voltage output range.

Take ZE03-O2 (0-25%vol) as an example: 0%vol is corresponding to 1.5V, but the corresponding value of 25%vol should subject to inspection report, not 0V, other values like 0.1V or 0.2V are possible.

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email: sales@winsensor.com

Leading gas sensing solutions supplier in China!

Zhengzhou Winsen Electronics Technology Co.,Ltd

Pin definition stable3.

GND

Ground

VCC

Power supply

VO

Original Voltage output

RXD

Series port input

TXD

Series port output

www.winsen-sensor.com

Fig3.Bottom view
The meaning of VO (Vout) : It means original voltage (linear) after amplifying circuit, rather than concentration value of current target gas in environment. If choose this pin test, users need to know when purchase, the zero voltage Vout0 and test voltage Vout1 can be shown in the inspection report delivered to customer with the modules together. Users can calculate gas concentration of current target gas in environment based on Vout0 and Vout1.
Take ZE03-CO for example: zero voltage Vout0 = 0.6 V; in 200ppm CO gas,Vout1=0.9V,
If the current voltage Voutx=1.2V, then the CO concentration:

Name rules
Model name: ZE03-X-X-X "Z" means module, "E " means electrochemical type sensor, "03" means version, the first X means detected gas, the second X means detection range, the third X means output way. Eg. "ZE03-CO-(0-1000)ppm-UART/VDC","ZE03-O2-(0-25)%VOL-UART/VDC". "UART/VDC" means the output way is series port and analog voltage (non standard voltage, refer to stable2.)
Communication Protocol

1.General Settings

Baud Rate

9600

Data Bits

8

Stop Bits

1

Parity

None

2.Communication Specification The default communication type is active upload and it sends gas concentration once every second (the concentration is 16 hexadecimal). If you want to switch to Q&A mode, please send 0x78 command, to change communication mode to 0x04(Q&A mode), then current concentration will be sent by module after it receiving 0x86 command (reading concentration), suggested communication cycle is 1s.

3.Communication Commands The default mode is active upload mode, the sensor will send gas concentration actively as follow without sending any command by users.

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email: sales@winsensor.com

Leading gas sensing solutions supplier in China!

Zhengzhou Winsen Electronics Technology Co.,Ltd

www.winsen-sensor.com

Receive 0

1

2

3

4

5

6

7

8

Start byte

Command Gas concentration

Gas No

number of decimal

reserved

Checksum
reserved

0xFF

0x86

High

Low 0x2B 0x01 0

0

4E

byte

byte

EXP.

FF 86 00 00 2B 01 00 00 4E (Take SO2 for example, the concentration is 0)

gas concentration=(High byte*256+Low byte)*resolution. Please note in the calculation formula, the High byte and Low byte means the decimalism value changed from hexadecimal. Number of decimal is 0, resolution is 1ppm, number of decimal is1, resolution is 0.1ppm, number of decimal is 2, resolution is 0.01ppm.

0X78--To modify the communication mode (0x03 is active upload mode, 0x04 is Q&A mode)

1

0x78

To change communication mode

Send

0

1

2

3

4

5

6

Start Byte Address Command

Communication Type

--

--

--

0XFF

0X01

0x78

0x04

0

0

0

EXP.

FF 01 78 04 00 00 00 00 83 (to switch to Q&A mode)

0

1

2

3

4

5

6

Start Byte Command

Return

--

--

--

--

Receive

0XFF

0X78

Success: 1 Failure: 0

0

0

0

0

EXP

FF 78 01 00 00 00 00 00 87

If users want to switch to active upload mode, send FF 01 78 03 00 00 00 00 84(hexadecimal).

0x86 -- To read the concentration value (This command is needed just under Q&A mode.)

1

0x86

To read concentration

0

1

2

3

4

5

6

7

Send

Start Byte

Address

Command

--

--

--

--

--

7

8

-- Checksum

0

0x83

7

8

-- Checksum

0

0x87 0x88

8 Checksum

0XFF

0X01

0x86

0

EXP.

FF 01 86 00 00 00 00 00 79

0

1

2

3

Receive

Start Byte

Command

Gas Concentration

0

0

0

0

4
Gas No.

5
number of decimal

6
reserved

7
reserved

0x79 8
Checksum

0XFF

0X86 High byte Low byte 0x2B 0x01

0

0

4E

EXP.

FF 86 00 00 2B 01 00 00 4E (Take SO2 for example, the concentration is 0)

gas concentration=(High byte*256+Low byte)*resolution

Please note that in the calculation formula, the High byte and Low byte means the decimalism value

changed from hexadecimal.

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email: sales@winsensor.com

Leading gas sensing solutions supplier in China!

Zhengzhou Winsen Electronics Technology Co.,Ltd

www.winsen-sensor.com

Instruction for Gas No.

No.

0x02 0x03

Gas

NH3

H2S

No.

0x2C 0x2E

Gas

NO2

HCL

0x04 CO 0x2F HCN

0x05 O2 0x31 CL2

0x06 H2 0x32 HF

0x08 C2H4 0x34 VOC

0x17 CH2O 0x3B C2H3CL

0x2A O3 0x45 PH3

0x2B SO2 0x46 DG01(NH3)

4.Checksum and calculation
/**********************************************************************
* Function Name: ucharFucCheckSum (uchar *i,ucharln)
* Functional description: checksumNon(sending/receiving commend Byte1+Byte2+...Byte7) +1

**********************************************************************/
unsigned char FucCheckSum(unsigned char *i,unsigned char ln)
{
unsigned char j,tempq=0;
i+=1;
for(j=0;j<(ln-2);j++)
{
tempq+=*i;
i++;
}
tempq=(~tempq)+1;
return(tempq);
}
Cautions
1. Please do not take away or plug the sensor in the module. 2. It is prohibited to weld the pins of the module. The socket could be welded. 3. Sensor shall avoid organic solvent, coatings, medicine, oil and high concentration gases. 4. Excessive impact or vibration should be avoided. 5. Please keep the modules warming up for at least 5 minutes when first using. 6. Please do not use the modules in systems which related to human being's safety. 7. Please do not use the modules in strong air convection environment. 8. Please do not expose the modules in high concentration organic gas for a long time. 9. Returned data of module serial port is real-time concentration of current target gas in environment, If you don't have standard gas, please do not use standard command, for it will cause calibrated data is clear

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email: sales@winsensor.com

Leading gas sensing solutions supplier in China!

Zhengzhou Winsen Electronics Technology Co.,Ltd

www.winsen-sensor.com

away and returned data of serial port is not accurate. 10. To judge whether module communication is normal, it is advisable to use tools that can change USB to TTL(communication level 3V), debug assistant software via serial port, and determine it by communication protocol. 11. When choosing module, users should choose products of different applications and ranges. If there is no special requirement, products will use conventional range.

Zhengzhou Winsen Electronics Technology Co., Ltd Add: No.299, Jinsuo Road, National Hi-Tech Zone,
Zhengzhou 450001 China
Tel: +86-371-67169097/67169670 Fax: +86-371-60932988 E-mail: sales@winsensor.com Website: www.winsen-sensor.com

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email: sales@winsensor.com

Leading gas sensing solutions supplier in China!

