Instruction Manual for UEi TEST INSTRUMENTS models including: RLD15B, RLD15B Refrigerant Leak Detector, Refrigerant Leak Detector, Leak Detector, Detector

Edmondson Supply | UEi RLD15B Refrigerant Leak Detector w/ Solid Electrolyte Sensor

Installation Instructions

17" L Probe, Digital 7-Segment LED Display, Leak Detector with Solid Electrolyte Sensor/(5) RLDTF Sensor Filter/RLDLS Leak Test Vial/(4) AA Battery/Hard Carrying Case and Manual for Refrigerant | Design Air

Instruction Manual

UEi 3-Pack Replacement Sensor for RLD15B Refrigerant Leak Detector - RLD15SENS


File Info : application/pdf, 2 Pages, 684.34KB

PDF preview unavailable. Download the PDF instead.

390273 WonJJX
Refrigerant Leak Detector

INSTRUCTION MANUAL
RLD15B

FEATURES

Leak Size Indicator

8

Low Bat.

The digital leak size indicator remains off until a leak is detected. A number from 1 - 9 will be displayed regardless of the sensitivity settings.

The number will increase or decrease
depending on the amount of refrigerant sensed.
The maximum value will be displayed once the
leak source has been located.
8
Low Bat.
Approximate Size Indications

Lo Norm. Hi Mute Sens.

Maximum # Displayed 1-3 4-6 7-9

Leak Size (oz/yr) < 0.1
0.1 - 0.5 > 0.5

1-800-547-5740 · Fax: (503) 643-6322 www.ueitest.com
email: info@ueitest.com

Audio Mute Function
1. Press Mute button to Mute speaker.

Mute Sens.

INTRODUCTION
Getting Started

1. TURN ON: Press Power Button

Lo Norm. Hi Mute Sens.

2. WARM UP:

Allow 20 sec. to warm up

0

(Indicator will blink

Low Bat.

and alarm will beep)

3. READY: When the flashing "0" stops and the green sensitivity indicator LED turns on

Lo Norm. Hi

4. The leak detector response to changes in refrigerant concentration. When detection occurs, move the probe away from the source and back again to confirm the leak source. The detector alarm will reset if the probe is held fixed at the source.

Sensitivity Level
1. Press Sens. button to Change / Scroll Sensitivity Levels. (Indicated By LED)
Work light

Mute Sens. Lo Norm. Hi

1. Press button to turn work light.

Low Battery Indicator Low Bat. Replace batteries when flashing
Battery replacement: 1. Remove battery cover on end of
instrument. (Fig1) 2. Replace 4 (AA) batteries with correct
polarity.
(Fig1)

AA AA

AA AA

RLD15B
Refrigerant Leak Detector
Limited Warranty
The RLD15B is warranted to be free from defects in materials and workmanship for a period of two years from the date of purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi's option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. Instruments out of warranty will be repaired (when repairable) for a service charge.
For more information on warranty and service:
www.ueitest.com · Email: info@ueitest.com 1-800-547-5740 · FAX: (503) 643-6322
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

Copyright © 2021 Kane USA Inc. All rights reserved. 17203

Filter Replacement
1. Replace Filter: Unscrew sensor tip as shown to replace filter. Replace filter whenever it becomes visibly dirty or every 2 to 3 months depending on use.
Remove Old (Dirty) Filter

Unscrew Sensor Tip

Replace w/ New Filter

Sensor Replacement
1) Remove sensor by unscrewing sensor tip and pulling out the socket.
Pull Straight Apart DO NOT TWIST!
Filter
Unscrew Sensor Tip
2) Install the new sensor by aligning the mark on the sensor cover with that on the probe and pressing together.

Align New Sensor With Tip And Push Straight On.

Screw On Sensor Tip

Filter
Push Straight Together DO NOT TWIST!

DO NOT TWIST!

WARNING
DO NOT TWIST OR FORCE THE SENSOR INTO THE SOCKET. Misalignment can damage the sensor pins.

SPECIFICATIONS

Sensitivity
Sensor Life Response Time Power Supply
Battery Life Warm-Up Time Probe Length Numerical Display Display Refresh Rate Operating Temperature Operating Humidity Operating Altitude Storage Temperature Pollution Degree
Weight, lbs
Certifications
Warranty

.05 oz/yr R134a .025 oz/yr R22, R1234yf
> 300 Hours  1sec
4 (AA) Alkaline 4 - 6 Hrs. Continuous
<20 Seconds 17 inches
7 Segment Digital (1-9) 3/sec.
-24 to 125°F (-31 to 52°C) <95% non. condensing
<10,000 ft. -4 to 122°F (20 to 50°C)
4 1.5 Lbs SAE J2791, SAE J2913 (A2L certified) EN14624-2012 ASHRAE 173-2012 2-Year limited warranty

Cross Sensitivity to Automotive Chemicals Some Automotive solvents and chemicals
have similar hydrocarbon properties as R134a and may elicit a positive response (< 30 seconds) from the RLD15B. Before leak detecting, clean up any chemicals in the list below that elicit a response.
Rain-X® Windshield wash fluid Ford® silicone lubricant Ford® Gasket adhesive (when wet) Ford® rust inhibitor (when wet) Loctite® Natural Blue® Degreaser (undiluted) Ford® brake parts cleaner (when wet) Ford® silicone rubber (when uncured) Motorcraft® antifreeze heated to 160°F Gunk® liquid wrench (when wet) Ford® spot remover (when wet) Ford® pumice lotion (with mineral solvent) Ford® motorcraft brake fluid Ford® carburetor cleaner (when wet)
Third party trademarks referenced are the property of their respective owners.



References

Adobe PDF Library 17.0 Adobe InDesign 18.0 (Macintosh)