User Manual for EVO HEAT models including: EVO FLEX Domestic Hot Water and Space Heat Pump, EVO FLEX, Domestic Hot Water and Space Heat Pump, Domestic Hot Water, Space Heat Pump, Heat Pump, Hot Water Pump, Pump, Domestic Pump, 1300 859 933
Manuals - Evoheat
EVO Flex | Domestic - Evoheat
File Info : application/pdf, 17 Pages, 2.12MB
DocumentDocumentPage 1 Evo Flex Series Manual Contents 1. Introduction...............................................................................................................................................2 2. Dimensions...............................................................................................................................................3 3. Safety Instructions ....................................................................................................................................4 4. Installation ................................................................................................................................................5 4.1 Transit.................................................................................................................................................5 4.2 Location of Install ................................................................................................................................5 4.3 Minimum Clearances ..........................................................................................................................5 4.4 Plumbing.............................................................................................................................................5 4.5 Electrical Connection ..........................................................................................................................5 4.6 Initial Start-up......................................................................................................................................6 5. Operation..................................................................................................................................................7 5.1 The Controller .....................................................................................................................................7 5.2 Operating Functions............................................................................................................................7 5.2.1 Start-up & Shutdown.....................................................................................................................7 5.2.2 Mode Switch .................................................................................................................................7 5.2.3 Setting the Target Temperature....................................................................................................7 5.2.4 Fast Heating Mode .......................................................................................................................8 5.2.5 Setting a Timer .............................................................................................................................8 5.2.6 Setup Interface .............................................................................................................................8 5.2.7 Setting the Date & Time................................................................................................................8 5.2.8 Fault Interface...............................................................................................................................8 5.2.9 Colour Display Calibration ............................................................................................................8 6. Troubleshooting........................................................................................................................................9 6.1 Electronic Control Fault Table .............................................................................................................9 6.2 Frequency Conversion Board Fault Table .........................................................................................10 6.3 Troubleshooting Table ......................................................................................................................11 7. Appendix ................................................................................................................................................12 7.1 Parameter List...................................................................................................................................12 7.2 Install Sketch Map.............................................................................................................................12 7.3 Automatic Filled Water Valve ............................................................................................................12 7.4 Leakage Pressure Valve ...................................................................................................................12 7.5 Assistant Heat Source Connection....................................................................................................13 7.6 Cable Specifications..........................................................................................................................13 7.7 Controller Interface Diagram .............................................................................................................14 8. Maintenance...........................................................................................................................................15 9. Warranty.................................................................................................................................................16 info@evoheat.com.au 1300 859 933 www.evoheat.com.au Page 2 Evo Flex Series Manual 1. Introduction This manual contains information relating to the installation, troubleshooting, operation, and maintenance of this EvoHeat unit. Instructions in this manual must always be followed. Failure to comply with these recommendations will invalidate the warranty. Should you have any questions or require technical support, call the EvoHeat office on 1300 859 933 to speak to our team. The data and information contained in this manual is correct at the time of publishing and is subject to change without notice. For the most up to date manual, contact EvoHeat directly. The Evo Flex Series heat pumps utilise advanced heat pump technology to achieve high efficiency with a C.O.P. of up to 4.8. With the application of DC inverter technology, the Evo Flex Series can adjust the output capacity automatically and control the room temperature accurately. TECHNICAL DATA Heating Capacity Range Heating Power Input Range Cooling Capacity Range Cooling Power Input Range Frequency ErP Level (35°C) ErP Level (55°C) Power Supply Electric Heater Max. Running Current Refrigerant Type Refrigerant Quantity Water Connection Water Flow Water Pressure Drop Water Pump Head DC Fan Motor Quantity DC Motor Power Input (MIN-MAX) DC Fan Speed (MIN-MAX) Pressure Sensor 1 Pressure Sensor 2 Noise Net Weight Net Dimensions (LxWxH) Operation Ambient Temp. kW kW kW kW Hz / / / kW A / kg / m3h kPa M / W rpm Bar Bar dB(A) kg mm °C Evo Flex 10 2.5-10.8 0.8-2.77 2.0-10.0 1.0~3.4 30~90 A++ A+ 220-240/1/50 3.0 18+13.7 R410A 2.4 1" 1.6 22 10 1 18-136 300-850 0~20 0~45 54 110 980 x 465 x 910 -20~52 Evo Flex 17 5.0-17.3 1.2-4.55 5.0-14.5 1.6~5.6 30~90 A++ A+ 220-240/1/50 / 27 R410A 3.2 1 ¼" 2.8 52 17 2 36-272 300-850 0~20 0~45 58 163 990 x 437 x 1315 -20~52 Evo Flex 25 7.0-25.1 2.5-6.54 7.0-20.0 2.5~9.0 30~90 A++ A+ 380-415/3/50 / 14 R410A 4.4 1 ¼" 4.2 45 18 2 50-340 300-900 0~20 0~45 62 219 1175 x 450 x 1588 -20~52 info@evoheat.com.au 1300 859 933 www.evoheat.com.au 2. Dimensions Page 3 Evo Flex Series Manual Evo Flex A (L) B (W) C (H) D E F G 10 980 465 910 700 445 338 132 Evo Flex A (L) B (W) C (H) D E F G H 17 990 437 1315 650 525 395 330 133 Evo Flex A (L) B (W) C (H) D E F G 25 1175 450 1588 725 400 320 254 info@evoheat.com.au 1300 859 933 www.evoheat.com.au Page 4 Evo Flex Series Manual 3. Safety Instructions · Installation, repairs and maintenance of this unit must be performed by a qualified technician. · Any wiring must comply with local electrical regulations. · If any abnormal instances occur or a strange smells, the unit must be shut off by the power supply. · Do not put fingers or objects into the fans or evaporator of the unit. · The unit must be earthed to avoid any risk caused by insulation defects. · No wiring must come into contact with the heat source or the rotating fan parts. · The unit must be handled and lifted with appropriate equipment in correlation with the unit's size and weight. · Electrical power must be switched off before any work is started on the unit. · Do not expose the unit to or install near any flammable gases. · Ensure there is a circuit breaker for this unit. · Copper and iron can not be used as a fuse. · The unit is equipped with an over-load protection system. After a previous stoppage, the unit will not start for at least 3 minutes. · If the supply cord is damaged, it must be replaced by the manufacturer, our service agent or a similarly qualified person in order to avoid a hazard. · USE SUPPLY WIRES SUITABLE FOR 75. · Caution: Single wall heat exchanger, not suitable for potable water connection. info@evoheat.com.au 1300 859 933 www.evoheat.com.au Page 5 Evo Flex Series Manual 4. Installation 4.1 Transit When transporting the unit, ensure the unit is kept standing upright. Laying the unit down may damage internal parts. If the unit needs to be hung up (such as for lifting with a crane) use an 8 metre cable. Ensure there is some kind of padding between the cable and the unit to prevent damage to the heat pump cabinet. 4.2 Location of Install The unit can be installed in any outdoor area which can carry the weight of heavy machinery, such as a terrace, rooftop, the ground etc. · The location must have adequate ventilation and be free from strong winds. · The installation location must be free from heat radiation and fire hazards. · Ensure there are no obstacles near the air inlet and outlet of the heat pump. · There must be a water channel around the heat pump to drain condensing water. · Ensure that there is enough space around the unit for maintenance. · The heat pump can be installed onto the concrete basement using expansion screws, or onto a steel frame with rubber feet which can be placed on the ground or rooftop. Ensure the unit is placed horizontally. 4.3 Minimum Clearances A: 500mm B: 1500mm C: 1000mm D: 500mm 4.4 Plumbing · Try to reduce the resistance to the water from the piping. · The piping must be clear and free from dirt and blockage. A water leakage test must be carried out to ensure that there is no water leaking before the installation can be made. · The pipe must be tested by pressure separately. DO NOT test it together with the unit. · There must be an expansion tank on the top point of the water loop, and the water level inside the tank must be at least 0.5meters higher than the top point of the water loop. · The flow switch is installed inside of the heat pump, check to ensure that the wiring and action of the switch is normal and controlled by the controller. · Try to avoid any air from being trapped inside the water pipe, there must be an air vent on the top point of the water loop. · There must be a thermometer and pressure meter at the water inlet and outlet for easy inspection during running. · There must be drainage on the low points of the water system, and there is already drainage on the chassis of the heat pump. The water in the system must be drained out during winter if the heat pump is not to be used. 4.5 Electrical Connection · Open the panel and open the power line hole · Thread the power line though the hole and connect it to the power line terminal. The three-core control line of the remote controller shall be plugged with the three-core signal line on the main board according to the wiring diagram. · For an external water pump, thread the power line of the water pump through the hole and connect it to the water pump terminals. · If an additional auxiliary heater is needed to be to be controlled by the heat pump controller, the relay (or power) of the aux-heather must be connected to the relevant output of the controller. info@evoheat.com.au 1300 859 933 www.evoheat.com.au Page 6 Evo Flex Series Manual 4.6 Initial Start-up Prior To: Check the indoor unit, make sure that the pipe connection is done correctly and that the relevant valves are open. Check the water loop to ensure that there is enough water inside of the expansion tank, that the water supply is good and that the water loop has no air in it and is full of water. Make sure there in good insulation for the water pipe. Check the electrical wiring. Make sure that the power voltage is normal, the screws are fastened, the wiring is made in line with the diagram and the earthing is connected. Check that the heat pump, including all the screws and different parts are in good order. When the power is on, review the indicator on the controller to see if there is any failure indications. The gas gauge can be connected to the check valve to see the high pressure (or low pressure) of the system during trial running. Trial Operation: Start the heat pump and check whether the water pump is running, if it is running normally there will be 0.2MPa on the water pressure meter. When the water pump runs for 1 minute, the compressor will start. Hear whether there is a strange sound coming from the compressor. If an abnormal sound occurs, please stop the unit and check the compressor. If the compressor runs well, look for the pressure meter of the refrigerant. Check whether the power input and running current is in line with the manual. If not stop the unit and check for why this may be occurring. Adjust the valves on the water loop to make sure that the hot (cool) water supply to each door is good and meets the requirement of heating (or cooling). Review whether the outlet water temperature is stable. info@evoheat.com.au 1300 859 933 www.evoheat.com.au 5. Operation 5.1 The Controller Page 7 Evo Flex Series Manual ON/OFF Turn the unit on or off. When the unit is on, the button will be red. MODE Switch modes TEMP. SETTING Enter the temperature setting menu. FAST HEATING Press this to begin rapid heating. TIMER SETUP Set a unit on/off timer. When a timer is on, this icon will be green. Check the unit status, time, factory parameters, temp. curve, timer & mute settings. FAULT When an error occurs this icon will flash at the top right of the screen. Tap the icon to see a record of failures. DEFROSTING When this icon is shown the unit is in defrosting mode. HOT WATER MODE When this icon is shown the unit is in hot water mode. HEATING MODE When this icon is shown the unit is in heating mode. 5.2 Operating Functions 5.2.1 Start-up & Shutdown To turn the unit on or off, press ON/OFF button. The icon will be grey when the unit is off, and green when it is on. 5.2.2 Mode Switch From the main menu there are five different operating modes that can be chosen from. Press MODE to select from the options: Hot Water, Heating, Cooling, Hot Water & Heating or Hot Water & Cooling Note: If you have purchased a heating-only model (with no cooling functions) "cooling" mode will not appear. 5.2.3 Setting the Target Temperature Press the TEMP. SETTING button to change the set temperature values of heating and/or cooling mode. Press the temperature value to alter the value, then press `Enter' to save and return to the main menu. info@evoheat.com.au 1300 859 933 www.evoheat.com.au 5.2.4 Fast Heating Mode Page 8 Evo Flex Series Manual While the unit is in heating mode, press the FAST HEATING to enable the rapid heating function. button 5.2.5 Setting a Timer 5.2.6 Setup Interface 5.2.7 Setting the Date & Time You can set a customised start-up and shutdown timer for your unit. Press the TIMER button on the main menu and enter your desired `ON' & `OFF' times. Press the On/Off button to the left of each time to toggle the start/end timers. When they are not on the button will be grey instead of coloured. Example: The unit will turn on at 17:10 and shut down at 20:10. STATUS Press this to view the status interface. CLOCK View/change system time & date settings. MUTE Turn on/off the silent function OR set mute timing intervals FACTORY Enter the factory interface. CURVE View the temperature curves. From the Setup interface, press CLOCK to enter into the system date & time setting menu. Use the arrows to adjust the date & time as required, then press the enter button to save changes. Press the return key to return to the previous menu or to cancel any changes. 5.2.8 Fault Interface Press the FAULT icon on the main menu to display a record of all failures that have occurred. After faults have been reviewed and corrected, press the top right `Clear' button to wipe the records. Note: when clearing the fault records, it may ask for a password first. The password will be the first 2 numbers of the top fault. In this example, the password would be 12. 5.2.9 Colour Display Calibration Keep clicking quickly at the blank area on any interface till you hear a long beep. You will then enter the calibration interface. Click "+" to start calibration. When you hear the beep again, you will have finished calibration and can exit. info@evoheat.com.au 1300 859 933 www.evoheat.com.au Page 9 Evo Flex Series Manual 6. Troubleshooting 6.1 Electronic Control Fault Table Protect/Fault Inlet Temp. Sensor Fault Outlet Temp. Sensor Fault Water Tank Temp Sensor At Sensor Fault Suction Temp. Sensor Fault Coil Temp Sensor Exhaust Temp Sensor Exhaust Overtemp Suction Pressure Sensor Fault Exhaust Pressure Sensor Fault Low AT Protection Electric Overheat Protection Communication Fault HP Protection LP Protection Primary Anti-Freezing Prot. Error Code P01 P02 P03 P04 P17 P153 P181 P182 PP2 Cause The temp. sensor is broken or short circuited The temp. sensor is broken or short circuited The temp. sensor is broken or short circuited The temp. sensor is broken or short circuited The temp. sensor is broken or short circuited The temp. sensor is broken or short circuited The temp. sensor is broken or short circuited The temp. sensor is broken or short circuited The pressure sensor is broken PP1 The pressure sensor is broken TP The environment temp. is low E04 The compressor is overloaded E08 Communication failure between wire controller and mainboard E11 The high-pressure switch is broken E12 Low pressure1 protection E19 The ambient temp. is low Solution Check or change the temp. sensor Check or change the temp. sensor Check or change the temp. sensor Check or change the temp. sensor Check or change the temp. sensor Check or change the temp. sensor Check or change the temp. sensor Check or change the temp. sensor Check or change the pressure sensor or pressure Check or change the pressure sensor or pressure Check whether the system of the compressor is running normally Check the wire connection between remote wire controller and main board Check the pressure switch and cold circuit Check the pressure switch and cold circuit Secondary Anti-Freezing Prot. E29 The ambient temp. is low Flow Switch Protection Compressor Overcurrent Shutdown Fault Anti-Freezing Prot DC Fan Motor 1 Failure E032 E051 E171 F031 No water/little water in water system The compressor is overloaded Water flow is not enough 1. Motor is in locked-rotor state 2. The wire connection between DC-fan motor module and fan motor is in bad contact Check the pipe water flow and water pump Check whether the system of the compressor is running normally Check the pipe water flow and whether water system is jammed 1. Change a new fan motor 2. Check the wire connection and make sure they are in good contact DC Fan Motor 2 Failure Dc Fan Motor Comms Failure F032 E081 1. Motor is in locked-rotor state 2. The wire connection between DC-fan motor module and fan motor is in bad contact Speed control module and main board communication fail 1. Change a new fan motor 2. Check the wire connection and make sure they are in good contact Check the communication connection info@evoheat.com.au 1300 859 933 www.evoheat.com.au Page 10 Evo Flex Series Manual 6.2 Frequency Conversion Board Fault Table Protect/Fault Error Code Cause IPM Overcurrent Shutdown Fault F00 IPM Input current is large Solution Check and adjust the current measurement Compressor Activation Failure F01 Lack of phase, step or drive hardware damage Check the measuring voltage, check frequency conversion board hardware PFC Fault F03 The PFC circuit protection Check the PFC switch tube short circuit or not DC Bus Overload F05 DC bus voltage<Dc bus Overload voltage protection value Check the input voltage measurement DC Bus Underload F06 DC bus voltage<Dc bus underload voltage protection value Check the input voltage measurement AC Input Underload F07 The input voltage is under, causing the input current to be too low Check the input voltage measurement AC Input Overload F08 The input voltage is over, causing the input current to be too high Check and adjust the current measurement Input Voltage Sample Fault F09 The input voltage sampling fault Check and adjust the current measurement Communication Failure between DSP and PFC F10 DSP and PFC connect fault Check the communication connection Communication Fault (DSP) F11 DSP and Inverter board communication failure Check the communication connection Communication Fault (Inverter Board) IPM Overheat Stop Weak Magnetism Alarm Input Voltage Lacking Phase IPM Current Sample Fault Sensor Fault of Module/Radiator IGBT Power Device Overhear Alarm Overload Alarm AC Input OverCurrent Alarm EEPROM Fault Alarm Destroyed EEPROM Activation Ban Alarm LP 15V Underload Fault F12 Communication failure between inverter Check the wire connection between board and main board remote inverter board and main board F13 The IPM module has overheated Check and adjust the current measurement F14 Compressor magnetic force is not enough F15 The input voltage lost phase Check and measure the voltage adjustment F16 IPM Sampling electricity is fault Check and adjust the current measurement F17 The transducer is overheating Check and adjust the current measurement F20 The transducer is overheating Check and adjust the current measurement F21 The compressor input current is too large Check and adjust the current measurement F22 Input current is too large F23 MCU Error Check and adjust the current measurement F24 MCU Error F25 The V15V is overload or undervoltage Check the V15V input voltage in range 13.5V~16.5 or not IGBT Power Device Overheat Fault F26 Transducer temperature is too high Check and adjust the current measurement info@evoheat.com.au 1300 859 933 www.evoheat.com.au 6.3 Troubleshooting Table Failure Possible Causes for the Failure Wrong power supply Heat pump cannot be started Power supply cable loose Circuit breaker open Lack of water in the piping Water pump is running with high noise or without heater Too much air in the water loop Water valves closed Dirt and blockage on the water filter Lack of refrigerant Heat pump capacity is low, compressor does not stop High compressor exhaust Low pressure problem of the system Bad insulation on water pipe Low heat exchange rate on air side exchanger Lack of water flow Too much refrigerant Low heat exchange rate on air side exchanger Lack of gas Block on filter or capillary Lack of water flow Compressor do not run Power supply failure Compressor contactor broken Power cable loose Protection on compressor Wrong setting on return water temp Lack of water flow High noise of compressor Fan do not run Liquid refrigerant goes into compressor Compressor failure Failure on fan relay Fan motor broken The compressor runs but heat pump has no heating or cooling capacity No gas in the heat pump Heat exchanger broken Compressor failure Low water flow rate Low outlet water temperature Low setting for the desired water temp Low water flow protection Lack of water in the system Failure on flow switch Page 11 Evo Flex Series Manual Solutions Shut off the power and check power supply Check power cable and make right connection Check for the cause and replace the fuse or circuit breaker Check the water supply and charge water to the piping Discharge the air in the water loop Open the valves in the water loop Clean the water filter Check for the gas leakage and recharge the refrigerant Make good insulation on water pipe Clean the air side heat exchanger Clean the water filter Discharge the redundant gas Clean the air side heat exchanger Check the gas leakage and recharge freon Replace filter or capillary Clean the water filter and discharge the air in water loop Check off the power supply Replace compressor contractor Tighten the power cable Check the compressor exhaust temp Reset the return water temp Clean the water filter and discharge the air in water loop Bad evaporation, check the cause for bad evaporation and fix Use new compressor Replace the fan relay Replace fan motor Check system leakage and recharge refrigerant Find out the cause and replace the heat exchanger Replace compressor Clean the water filter and discharge the air in water loop Reset the desired water temperature Clean the water filter and discharge the air in water loop Replace the flow switch info@evoheat.com.au 1300 859 933 www.evoheat.com.au 7. Appendix 7.1 Parameter List Meaning Refrigeration target temperature set point Heating the target temperature set point 7.2 Install Sketch Map Special Installation (Expandable Water Tank) 1. Main Unit 2. Connecting Hose 3. Pressure Meter 4. General Valve 5. Three-way Valve 6. Y-type Filter 7. Safety Valve 8. Expansion Tank 9. Vent Valve 10. Automatic Refill Valve 11. Pressure Differential Bypass Valve 12. Drain Valve 13. Non-return Valve 14. Water Pump 15. Fan Coil Page 12 Evo Flex Series Manual Default 12°C 40°C Remarks Adjustable Adjustable 7.3 Automatic Filled Water Valve B When the automatic filled-water valve is installed, the arrowhead orientation of inlet water must accord with the orientation of the valve. C Automatic filled-water has been adjusted in advance to 1.5ba. If readjusting the pressure of inlet water, please operate as follows: · Open the Screw Cap ( C ) · If reducing the pressure of water supply, unscrew the pressure to adjust the 1/4' screw (B) 1/2' · If increasing the pressure of water supply, screw down the pressure to adjust the screw (B) D When the system needs to be filled with water at first, rest the handle (A) of filled- A water. Then the handle (A) can return (close) when the system is full of water. Automatic filled-water valve needs periodic cleaning. When you must close the tap, unscrew the plug (D), remove the inside filter net. Reassemble after cleaning. NOTE: There are two connections for water pressure meters in the central section of automatic filled-water, where the water pressure meter can be connected directly and display the set pressure. The screw cap ( C ) must be tweaked after adjusting the filled-water pressure. 7.4 Leakage Pressure Valve The action pressure of the leakage pressure valve is more than 3bar (valve is open), but the pressure cannot be adjusted. The valve will open automatically to make sure that the water loop of air-con system is safe when the water pressure in the backwater side is higher than the set pressure. ou tle t in le t info@evoheat.com.au 1300 859 933 www.evoheat.com.au Page 13 Evo Flex Series Manual 7.5 Assistant Heat Source Connection Unit provides the connection of assistant heat-source, which can be not only be for a gas fired boiler, but also for an electronic boiler or warm-net pipe for city accordingly. Water Chiller & Heat Pump + Assistant Gas-Fired Boiler Water Chiller & Heat Pump + Assistant Electronic Boiler 7.6 Cable Specifications Nameplate maximum current No more than 10A 10~16A 16~25A 25~32A 32~40A 40~63A 63~75A 75~101A 101~123A 123~148A 148~186A 186~224A Phase line (Single Phase) 2 x 1.5mm2 2 x 2.5mm2 2 x 4mm2 2 x 6mm2 2 x 10mm2 2 x 16mm2 2 x 25mm2 2 x 25mm2 2 x 35mm2 2 x 50mm2 2 x 70mm2 2 x 95mm2 Phase Line (Three Phase) 3 x 1.5mm2 3 x 2.5mm2 3 x 4mm2 3 x 6mm2 3 x 10mm2 3 x 16mm2 3 x 25mm2 3 x 25mm2 3 x 35mm2 3 x 50mm2 3 x 70mm2 3 x 95mm2 Earth line MCB 1.5mm2 2.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 25mm2 35mm2 50mm2 70mm2 95mm2 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A Creepage Signal Protector Line 30mA less n x than 0.1 sec 0.5mm2 info@evoheat.com.au 1300 859 933 www.evoheat.com.au 7.7 Controller Interface Diagram No. Sign Meaning 01 RO 01 Compressor (output 220230VAC) 02 RO 02 Water Pump (output 220230VAC) 03 RO 03 4-way valve (output 220230VAC) 04 RO 04 Fan (output 220-230VAC) 05 RO 05 Reserved 06 RO 06 Anti-freezing heater (output 220-230VAC) 07 RO 07 Crankshaft Heater (output 220230VAC) 08 RO 08 Spray Valve (output 220230VAC) 09 RO 09 Electric Auxiliary Heater (output 220-230VAC) 10 RO 10 Reserved 12 RO 11 Alarm (output 220-230VAC) 12 RO 12 Hot Water Pump 13 RO 13 Electromagnetic three-way valve 14 RO 14~RO18 Reserved 15 AC-L Live Wire (output 220-230VAC) 16 AC-N Neutral Wire (output 220230VAC) 17 AI01 Water Inlet Temperature (input) 18 AI02 Water output temperature (input) 19 AI03 System exhaust temperature (input) 20 AI04 Reserved 21 AI05 System suction temperature (input) 22 AI06 System coil temperature (input) 23 AI07 Ambient temperature (input) 24 AI08 Water tank temperature (input) 25 AI09-AI20 Reserved 26 AI21 Suction pressure input 27 AI22 Exhaust pressure input 28 DI01 System high pressure (input) 29 DI02 System low pressure (input) 30 DI03 Water flow switch (input) 31 DI04 Emergency switch (input) 32 DI05 Mode switch (input) 33 DI06 Master-slave machine switch (input) 34 DI07 Electric heating overload protection switch (input) 35 485_A1 Frequency Conversion Board Communications 36 485_B1 Frequency Conversion Board Communications 37 485_A2 Communicate with wire controller and DC fan module 38 485_B2 Communicate with wire controller and DC fan module 39 485_A3 Reserved 40 485_B3 Reserved 41 12V 12V (output) 42 5V 5V (output) 43 CN1 Electronic expansion valve 44 CN2-CN4 Reserved Page 14 Evo Flex Series Manual info@evoheat.com.au 1300 859 933 www.evoheat.com.au 8. Maintenance Page 15 Evo Flex Series Manual DO I NEED TO GET MY UNIT SERVICED? It is recommended that you get your EvoHeat unit serviced once a year by your local certified air conditioning or refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary. During the service, they will check the operational pressures of the refrigeration system and give the unit and fins a good clean to ensure maximum performance. DO WE HAVE RECOMMENDED SERVICE AGENTS? EvoHeat have a large database of recommended service agents. Please contact EvoHeat tech support on 1300 859 933 for your local service agent details. SHOULD I CHECK MY UNIT REGULARLY? We recommend you check your unit regularly to avoid potential issues and damage to your heat pump. Check the water inlet/outlets often for leaks. You should avoid the condition of no water or air entering into the system, as this will influence unit's performance and reliability. The area around the unit should be dry, clean and well ventilated. Make sure there is nothing blocking the airflow of the heater e.g. Leaf litter. Clean the heat exchanger every few months to keep a good heat exchange rate and save energy. WHAT SHOULD I BE CHECKING REGULARLY? You should discharge the water at the bottom of the water pump if the unit will not be used for an extended period. Discharge all water in the water pump and water system so that freezing of the water in the pump or water system does not occur. Check the unit thoroughly and fill the system with water fully before using it for the first time after a period of time. Check the power supply and cable connection often, should the unit begin to operate abnormally, switch it off and contact the qualified technician Clean the water filter periodically to maintain good water quality. Lack of water and dirty water can damage the unit. The heat pump will start the water every 72 hours when it is not running to avoid freezing. The water loop of the heat pump MUST be protected from freezing in winter. Do not shut off the power supply to the heat pump in winter. When the air temperature is below 0°C, if the inlet water temperature is above 2°C and below 4°C the water pump will begin freezing protection. If the inlet water is lower than 2°C, the heat pump will begin heating. info@evoheat.com.au 1300 859 933 www.evoheat.com.au 9. Warranty Refer to the EvoHeat website for warranty details · Australia: https://evoheat.com.au/warranty-terms/ · South East Asia: http://evoheat.com.sg/warranty/ Page 16 Evo Flex Series Manual 1. Warranty terms are from date of purchase. 2. This warranty excludes any defect or injury caused by or resulting from misuse, abuse, neglect, accidental damage, improper voltage, vermin infestation, incompetent installation, any fault not attributable to faulty manufacture or parts, any modifications which affect the reliability or performance of the unit. 3. This warranty does not cover the following: a. Natural Disasters (hail, lightening, flood, fire etc.) b. Rust or damage to paintwork caused by a corrosive atmosphere c. When serviced by an unauthorized person without the permission of Evo Industries d. When a unit is installed by an unqualified person e. Where a unit is incorrectly installed f. When failure occurs due to improper or faulty installation g. Failure due to improper maintenance (refer Operating Instructions) h. `No Fault Found' service calls where the perceived problem is explained within the i. Costs associated with delivery, handling, freighting, or damage to the product in transit. 4. If warranty service is required, you should: a. contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b. provide a copy of your receipt as proof of purchase c. have completed the online Warranty Registration Form 5. Onsite technical service is available within the normal operating area of your Evo Authorised Service Agents. Service outside this area will incur a traveling fee. 6. Unless otherwise specified to the purchaser, the benefits conferred by this express warranty and additional to all other conditions, warranties, rights and remedies expressed or implied by the Trade Practices Act 1974 and similar consumer protection provisions contained in legislation of the States and Territories and all other obligations and liabilities on the part of the manufacturer or supplier and nothing contained herein shall restrict or modify such rights, remedies, obligations or liabilities. REGISTER YOUR WARRANTY EvoHeat highly recommend customers complete their warranty details online to ensure efficient warranty claim processing. To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/ info@evoheat.com.au 1300 859 933 www.evoheat.com.au