MANUAL-Evo-Flex
Page 1 Evo Flex Series Manual
Contents
1. Introduction...............................................................................................................................................2 2. Dimensions...............................................................................................................................................3 3. Safety Instructions ....................................................................................................................................4 4. Installation ................................................................................................................................................5
4.1 Transit.................................................................................................................................................5 4.2 Location of Install ................................................................................................................................5 4.3 Minimum Clearances ..........................................................................................................................5 4.4 Plumbing.............................................................................................................................................5 4.5 Electrical Connection ..........................................................................................................................5 4.6 Initial Start-up......................................................................................................................................6 5. Operation..................................................................................................................................................7 5.1 The Controller .....................................................................................................................................7 5.2 Operating Functions............................................................................................................................7
5.2.1 Start-up & Shutdown.....................................................................................................................7 5.2.2 Mode Switch .................................................................................................................................7 5.2.3 Setting the Target Temperature....................................................................................................7 5.2.4 Fast Heating Mode .......................................................................................................................8 5.2.5 Setting a Timer .............................................................................................................................8 5.2.6 Setup Interface .............................................................................................................................8 5.2.7 Setting the Date & Time................................................................................................................8 5.2.8 Fault Interface...............................................................................................................................8 5.2.9 Colour Display Calibration ............................................................................................................8 6. Troubleshooting........................................................................................................................................9 6.1 Electronic Control Fault Table .............................................................................................................9 6.2 Frequency Conversion Board Fault Table .........................................................................................10 6.3 Troubleshooting Table ......................................................................................................................11 7. Appendix ................................................................................................................................................12 7.1 Parameter List...................................................................................................................................12 7.2 Install Sketch Map.............................................................................................................................12 7.3 Automatic Filled Water Valve ............................................................................................................12 7.4 Leakage Pressure Valve ...................................................................................................................12 7.5 Assistant Heat Source Connection....................................................................................................13 7.6 Cable Specifications..........................................................................................................................13 7.7 Controller Interface Diagram .............................................................................................................14 8. Maintenance...........................................................................................................................................15 9. Warranty.................................................................................................................................................16

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

Page 2 Evo Flex Series Manual
1. Introduction
This manual contains information relating to the installation, troubleshooting, operation, and maintenance of this EvoHeat unit. Instructions in this manual must always be followed. Failure to comply with these recommendations will invalidate the warranty. Should you have any questions or require technical support, call the EvoHeat office on 1300 859 933 to speak to our team.
The data and information contained in this manual is correct at the time of publishing and is subject to change without notice. For the most up to date manual, contact EvoHeat directly.
The Evo Flex Series heat pumps utilise advanced heat pump technology to achieve high efficiency with a C.O.P. of up to 4.8. With the application of DC inverter technology, the Evo Flex Series can adjust the output capacity automatically and control the room temperature accurately.

TECHNICAL DATA Heating Capacity Range Heating Power Input Range Cooling Capacity Range Cooling Power Input Range Frequency ErP Level (35°C) ErP Level (55°C) Power Supply Electric Heater Max. Running Current Refrigerant Type Refrigerant Quantity Water Connection Water Flow Water Pressure Drop Water Pump Head DC Fan Motor Quantity DC Motor Power Input (MIN-MAX) DC Fan Speed (MIN-MAX) Pressure Sensor 1 Pressure Sensor 2 Noise Net Weight Net Dimensions (LxWxH) Operation Ambient Temp.

kW kW kW kW Hz
/ / / kW A / kg / m3h kPa M / W rpm Bar Bar dB(A) kg mm °C

Evo Flex 10 2.5-10.8 0.8-2.77 2.0-10.0 1.0~3.4 30~90 A++ A+
220-240/1/50 3.0
18+13.7 R410A
2.4 1" 1.6 22 10 1 18-136 300-850 0~20 0~45 54 110 980 x 465 x 910 -20~52

Evo Flex 17 5.0-17.3 1.2-4.55 5.0-14.5 1.6~5.6 30~90 A++ A+
220-240/1/50 / 27
R410A 3.2 1 ¼" 2.8 52 17 2
36-272 300-850
0~20 0~45
58 163 990 x 437 x 1315 -20~52

Evo Flex 25 7.0-25.1 2.5-6.54 7.0-20.0 2.5~9.0 30~90 A++ A+
380-415/3/50 / 14
R410A 4.4 1 ¼" 4.2 45 18 2
50-340 300-900
0~20 0~45
62 219 1175 x 450 x 1588 -20~52

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

2. Dimensions

Page 3 Evo Flex Series Manual

Evo Flex

A (L)

B (W)

C (H)

D

E

F

G

10

980

465

910

700

445

338

132

Evo Flex A (L)

B (W)

C (H)

D

E

F

G

H

17

990

437

1315

650

525

395

330

133

Evo Flex

A (L)

B (W)

C (H)

D

E

F

G

25

1175

450

1588

725

400

320

254

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

Page 4 Evo Flex Series Manual

3. Safety Instructions

·

Installation, repairs and maintenance of this unit must be performed by a qualified technician.

·

Any wiring must comply with local electrical regulations.

·

If any abnormal instances occur or a strange smells, the unit must be shut off by the power supply.

·

Do not put fingers or objects into the fans or evaporator of the unit.

·

The unit must be earthed to avoid any risk caused by insulation defects.

·

No wiring must come into contact with the heat source or the rotating fan parts.

·

The unit must be handled and lifted with appropriate equipment in correlation with the unit's size and

weight.

·

Electrical power must be switched off before any work is started on the unit.

·

Do not expose the unit to or install near any flammable gases.

·

Ensure there is a circuit breaker for this unit.

·

Copper and iron can not be used as a fuse.

·

The unit is equipped with an over-load protection system. After a previous stoppage, the unit will not

start for at least 3 minutes.

·

If the supply cord is damaged, it must be replaced by the manufacturer, our service agent or a

similarly qualified person in order to avoid a hazard.

·

USE SUPPLY WIRES SUITABLE FOR 75.

·

Caution: Single wall heat exchanger, not suitable for potable water connection.

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

Page 5 Evo Flex Series Manual

4. Installation

4.1 Transit
When transporting the unit, ensure the unit is kept standing upright. Laying the unit down may damage internal parts.

If the unit needs to be hung up (such as for lifting with a crane) use an 8 metre cable. Ensure there is some kind of padding between the cable and the unit to prevent damage to the heat pump cabinet.

4.2 Location of Install
The unit can be installed in any outdoor area which can carry the weight of heavy machinery, such as a terrace, rooftop, the ground etc.

·

The location must have adequate ventilation and be free from strong winds.

·

The installation location must be free from heat radiation and fire hazards.

·

Ensure there are no obstacles near the air inlet and outlet of the heat pump.

·

There must be a water channel around the heat pump to drain condensing water.

·

Ensure that there is enough space around the unit for maintenance.

·

The heat pump can be installed onto the concrete basement using expansion screws, or onto a steel frame

with rubber feet which can be placed on the ground or rooftop. Ensure the unit is placed horizontally.

4.3 Minimum Clearances

A: 500mm B: 1500mm C: 1000mm D: 500mm

4.4 Plumbing
· Try to reduce the resistance to the water from the piping.
· The piping must be clear and free from dirt and blockage. A water leakage test must be carried out to ensure that there is no water leaking before the installation can be made.
· The pipe must be tested by pressure separately. DO NOT test it together with the unit.
· There must be an expansion tank on the top point of the water loop, and the water level inside the tank must be at least 0.5meters higher than the top point of the water loop.
· The flow switch is installed inside of the heat pump, check to ensure that the wiring and action of the switch is normal and controlled by the controller.
· Try to avoid any air from being trapped inside the water pipe, there must be an air vent on the top point of the water loop.
· There must be a thermometer and pressure meter at the water inlet and outlet for easy inspection during running.
· There must be drainage on the low points of the water system, and there is already drainage on the chassis of the heat pump. The water in the system must be drained out during winter if the heat pump is not to be used.
4.5 Electrical Connection
· Open the panel and open the power line hole · Thread the power line though the hole and connect it to the power line terminal. The three-core control line of the
remote controller shall be plugged with the three-core signal line on the main board according to the wiring diagram. · For an external water pump, thread the power line of the water pump through the hole and connect it to the water pump terminals. · If an additional auxiliary heater is needed to be to be controlled by the heat pump controller, the relay (or power) of the aux-heather must be connected to the relevant output of the controller.

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

Page 6 Evo Flex Series Manual
4.6 Initial Start-up Prior To:
Check the indoor unit, make sure that the pipe connection is done correctly and that the relevant valves are open.
Check the water loop to ensure that there is enough water inside of the expansion tank, that the water supply is good and that the water loop has no air in it and is full of water. Make sure there in good insulation for the water pipe.
Check the electrical wiring. Make sure that the power voltage is normal, the screws are fastened, the wiring is made in line with the diagram and the earthing is connected.
Check that the heat pump, including all the screws and different parts are in good order. When the power is on, review the indicator on the controller to see if there is any failure indications. The gas gauge can be connected to the check valve to see the high pressure (or low pressure) of the system during trial running.
Trial Operation:
Start the heat pump and check whether the water pump is running, if it is running normally there will be 0.2MPa on the water pressure meter.
When the water pump runs for 1 minute, the compressor will start. Hear whether there is a strange sound coming from the compressor. If an abnormal sound occurs, please stop the unit and check the compressor. If the compressor runs well, look for the pressure meter of the refrigerant.
Check whether the power input and running current is in line with the manual. If not stop the unit and check for why this may be occurring.
Adjust the valves on the water loop to make sure that the hot (cool) water supply to each door is good and meets the requirement of heating (or cooling).
Review whether the outlet water temperature is stable.

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

5. Operation 5.1 The Controller

Page 7 Evo Flex Series Manual

ON/OFF

Turn the unit on or off. When the unit is on, the button will be red.

MODE Switch modes

TEMP. SETTING

Enter the temperature setting menu.

FAST HEATING

Press this to begin rapid heating.

TIMER SETUP

Set a unit on/off timer. When a timer is on, this icon will be green.
Check the unit status, time, factory parameters, temp. curve, timer & mute settings.

FAULT
When an error occurs this icon will flash at the top right of the screen. Tap the icon to
see a record of failures.

DEFROSTING
When this icon is shown the unit is in defrosting mode.

HOT WATER MODE
When this icon is shown the unit is in hot water mode.

HEATING MODE
When this icon is shown the unit is in heating mode.

5.2 Operating Functions
5.2.1 Start-up & Shutdown To turn the unit on or off, press ON/OFF button. The icon will be grey when the unit is off, and green when it is on. 5.2.2 Mode Switch
From the main menu there are five different operating modes that can be chosen from. Press MODE to select from the options:
Hot Water, Heating, Cooling, Hot Water & Heating or Hot Water & Cooling
Note: If you have purchased a heating-only model (with no cooling functions) "cooling" mode will not appear.

5.2.3 Setting the Target Temperature

Press the TEMP. SETTING button to change the set temperature values of heating and/or cooling mode.
Press the temperature value to alter the value, then press `Enter' to save and return to the main menu.

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

5.2.4 Fast Heating Mode

Page 8 Evo Flex Series Manual

While the unit is in heating mode, press the FAST HEATING to enable the rapid heating function.

button

5.2.5 Setting a Timer 5.2.6 Setup Interface 5.2.7 Setting the Date & Time

You can set a customised start-up and shutdown timer for your unit.
Press the TIMER button on the main menu and enter your desired `ON' & `OFF' times.
Press the On/Off button to the left of each time to toggle the start/end timers. When they are not on the button will be grey instead of coloured.
Example: The unit will turn on at 17:10 and shut down at 20:10.

STATUS Press this to view the status interface.

CLOCK

View/change system time & date settings.

MUTE

Turn on/off the silent function OR set mute timing intervals

FACTORY Enter the factory interface.

CURVE

View the temperature curves.

From the Setup interface, press CLOCK to enter into the system date & time setting menu. Use the arrows to adjust the date & time as required, then press the enter button to save changes.
Press the return key to return to the previous menu or to cancel any changes.

5.2.8 Fault Interface

Press the FAULT icon on the main menu to display a record of all failures that have occurred.
After faults have been reviewed and corrected, press the top right `Clear' button to wipe the records.
Note: when clearing the fault records, it may ask for a password first. The password will be the first 2 numbers of the top fault. In this example, the password would be 12.

5.2.9 Colour Display Calibration
Keep clicking quickly at the blank area on any interface till you hear a long beep. You will then enter the calibration interface. Click "+" to start calibration. When you hear the beep again, you will have finished calibration and can exit.

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

Page 9 Evo Flex Series Manual

6. Troubleshooting

6.1 Electronic Control Fault Table

Protect/Fault Inlet Temp. Sensor Fault Outlet Temp. Sensor Fault Water Tank Temp Sensor At Sensor Fault Suction Temp. Sensor Fault Coil Temp Sensor Exhaust Temp Sensor Exhaust Overtemp Suction Pressure Sensor Fault Exhaust Pressure Sensor Fault Low AT Protection Electric Overheat Protection
Communication Fault
HP Protection LP Protection Primary Anti-Freezing Prot.

Error Code P01 P02 P03 P04 P17 P153 P181 P182 PP2

Cause
The temp. sensor is broken or short circuited
The temp. sensor is broken or short circuited
The temp. sensor is broken or short circuited
The temp. sensor is broken or short circuited
The temp. sensor is broken or short circuited
The temp. sensor is broken or short circuited
The temp. sensor is broken or short circuited
The temp. sensor is broken or short circuited
The pressure sensor is broken

PP1 The pressure sensor is broken TP The environment temp. is low E04 The compressor is overloaded

E08

Communication failure between wire controller and mainboard

E11

The high-pressure switch is broken

E12 Low pressure1 protection

E19 The ambient temp. is low

Solution
Check or change the temp. sensor
Check or change the temp. sensor
Check or change the temp. sensor
Check or change the temp. sensor
Check or change the temp. sensor
Check or change the temp. sensor
Check or change the temp. sensor
Check or change the temp. sensor Check or change the pressure sensor or pressure Check or change the pressure sensor or pressure
Check whether the system of the compressor is running normally Check the wire connection between remote wire controller and main board Check the pressure switch and cold circuit Check the pressure switch and cold circuit

Secondary Anti-Freezing Prot. E29 The ambient temp. is low

Flow Switch Protection Compressor Overcurrent Shutdown Fault Anti-Freezing Prot
DC Fan Motor 1 Failure

E032 E051 E171
F031

No water/little water in water system
The compressor is overloaded
Water flow is not enough
1. Motor is in locked-rotor state 2. The wire connection between DC-fan motor module and fan motor is in bad contact

Check the pipe water flow and water pump
Check whether the system of the compressor is running normally
Check the pipe water flow and whether water system is jammed
1. Change a new fan motor 2. Check the wire connection and make sure they are in good contact

DC Fan Motor 2 Failure Dc Fan Motor Comms Failure

F032 E081

1. Motor is in locked-rotor state 2. The wire connection between DC-fan motor module and fan motor is in bad contact
Speed control module and main board communication fail

1. Change a new fan motor 2. Check the wire connection and make sure they are in good contact
Check the communication connection

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

Page 10 Evo Flex Series Manual

6.2 Frequency Conversion Board Fault Table

Protect/Fault

Error Code

Cause

IPM Overcurrent Shutdown Fault F00 IPM Input current is large

Solution
Check and adjust the current measurement

Compressor Activation Failure

F01

Lack of phase, step or drive hardware damage

Check the measuring voltage, check frequency conversion board hardware

PFC Fault

F03 The PFC circuit protection

Check the PFC switch tube short circuit or not

DC Bus Overload

F05

DC bus voltage<Dc bus Overload ­ voltage protection value

Check the input voltage measurement

DC Bus Underload

F06

DC bus voltage<Dc bus underload ­ voltage protection value

Check the input voltage measurement

AC Input Underload

F07

The input voltage is under, causing the input current to be too low

Check the input voltage measurement

AC Input Overload

F08

The input voltage is over, causing the input current to be too high

Check and adjust the current measurement

Input Voltage Sample Fault

F09 The input voltage sampling fault

Check and adjust the current measurement

Communication Failure between DSP and PFC

F10 DSP and PFC connect fault

Check the communication connection

Communication Fault (DSP)

F11

DSP and Inverter board communication failure

Check the communication connection

Communication Fault (Inverter Board) IPM Overheat Stop
Weak Magnetism Alarm
Input Voltage Lacking Phase
IPM Current Sample Fault
Sensor Fault of Module/Radiator IGBT Power Device Overhear Alarm Overload Alarm
AC Input OverCurrent Alarm EEPROM Fault Alarm Destroyed EEPROM Activation Ban Alarm LP 15V Underload Fault

F12

Communication failure between inverter Check the wire connection between

board and main board

remote inverter board and main board

F13 The IPM module has overheated

Check and adjust the current measurement

F14

Compressor magnetic force is not enough

F15 The input voltage lost phase

Check and measure the voltage adjustment

F16 IPM Sampling electricity is fault

Check and adjust the current measurement

F17 The transducer is overheating

Check and adjust the current measurement

F20 The transducer is overheating

Check and adjust the current measurement

F21

The compressor input current is too large

Check and adjust the current measurement

F22 Input current is too large F23 MCU Error

Check and adjust the current measurement

F24 MCU Error

F25 The V15V is overload or undervoltage

Check the V15V input voltage in range 13.5V~16.5 or not

IGBT Power Device Overheat Fault

F26 Transducer temperature is too high

Check and adjust the current measurement

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

6.3 Troubleshooting Table

Failure

Possible Causes for the Failure Wrong power supply

Heat pump cannot be started Power supply cable loose

Circuit breaker open

Lack of water in the piping

Water pump is running with high noise or without heater

Too much air in the water loop Water valves closed Dirt and blockage on the water filter

Lack of refrigerant

Heat pump capacity is low, compressor does not stop
High compressor exhaust
Low pressure problem of the system

Bad insulation on water pipe Low heat exchange rate on air side exchanger Lack of water flow Too much refrigerant Low heat exchange rate on air side exchanger Lack of gas Block on filter or capillary
Lack of water flow

Compressor do not run

Power supply failure Compressor contactor broken Power cable loose Protection on compressor Wrong setting on return water temp

Lack of water flow

High noise of compressor Fan do not run

Liquid refrigerant goes into compressor
Compressor failure Failure on fan relay Fan motor broken

The compressor runs but heat pump has no heating or cooling capacity

No gas in the heat pump Heat exchanger broken

Compressor failure

Low water flow rate Low outlet water temperature
Low setting for the desired water temp

Low water flow protection

Lack of water in the system Failure on flow switch

Page 11 Evo Flex Series Manual
Solutions Shut off the power and check power supply Check power cable and make right connection Check for the cause and replace the fuse or circuit breaker Check the water supply and charge water to the piping Discharge the air in the water loop Open the valves in the water loop Clean the water filter Check for the gas leakage and recharge the refrigerant Make good insulation on water pipe
Clean the air side heat exchanger
Clean the water filter Discharge the redundant gas
Clean the air side heat exchanger
Check the gas leakage and recharge freon Replace filter or capillary Clean the water filter and discharge the air in water loop Check off the power supply Replace compressor contractor Tighten the power cable Check the compressor exhaust temp Reset the return water temp Clean the water filter and discharge the air in water loop Bad evaporation, check the cause for bad evaporation and fix Use new compressor Replace the fan relay Replace fan motor Check system leakage and recharge refrigerant Find out the cause and replace the heat exchanger Replace compressor Clean the water filter and discharge the air in water loop Reset the desired water temperature Clean the water filter and discharge the air in water loop Replace the flow switch

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

7. Appendix 7.1 Parameter List
Meaning Refrigeration target temperature set point Heating the target temperature set point

7.2 Install Sketch Map
Special Installation (Expandable Water Tank)

1. Main Unit 2. Connecting Hose
3. Pressure Meter
4. General Valve 5. Three-way Valve 6. Y-type Filter 7. Safety Valve 8. Expansion Tank

9. Vent Valve
10. Automatic Refill Valve
11. Pressure Differential Bypass Valve 12. Drain Valve 13. Non-return Valve 14. Water Pump 15. Fan Coil

Page 12 Evo Flex Series Manual

Default 12°C 40°C

Remarks Adjustable Adjustable

7.3 Automatic Filled Water Valve

B
When the automatic filled-water valve is installed, the arrowhead orientation of inlet

water must accord with the orientation of the valve.

C

Automatic filled-water has been adjusted in advance to 1.5ba.

If readjusting the pressure of inlet water, please operate as follows:

·

Open the Screw Cap ( C )

·

If reducing the pressure of water supply, unscrew the pressure to adjust the

1/4'

screw (B)

1/2'

·

If increasing the pressure of water supply, screw down the pressure to

adjust the screw (B)
D

When the system needs to be filled with water at first, rest the handle (A) of filled-

A

water. Then the handle (A) can return (close) when the system is full of water.

Automatic filled-water valve needs periodic cleaning. When you must close the tap, unscrew the plug (D), remove the inside filter net. Reassemble after cleaning.

NOTE: There are two connections for water pressure meters in the central section of automatic filled-water, where the water pressure meter can be connected directly and display the set pressure. The screw cap ( C ) must be tweaked after adjusting the filled-water pressure.

7.4 Leakage Pressure Valve
The action pressure of the leakage pressure valve is more than 3bar (valve is open), but the pressure cannot be adjusted.
The valve will open automatically to make sure that the water loop of air-con system is safe when the water pressure in the backwater side is higher than the set pressure.

ou tle t in le t

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

Page 13 Evo Flex Series Manual
7.5 Assistant Heat Source Connection
Unit provides the connection of assistant heat-source, which can be not only be for a gas fired boiler, but also for an electronic boiler or warm-net pipe for city accordingly.

Water Chiller & Heat Pump + Assistant Gas-Fired Boiler

Water Chiller & Heat Pump + Assistant Electronic Boiler

7.6 Cable Specifications
Nameplate maximum current
No more than 10A 10~16A 16~25A 25~32A 32~40A 40~63A 63~75A 75~101A
101~123A 123~148A 148~186A 186~224A

Phase line (Single Phase)
2 x 1.5mm2 2 x 2.5mm2 2 x 4mm2 2 x 6mm2 2 x 10mm2 2 x 16mm2 2 x 25mm2 2 x 25mm2 2 x 35mm2 2 x 50mm2 2 x 70mm2 2 x 95mm2

Phase Line (Three Phase)
3 x 1.5mm2 3 x 2.5mm2 3 x 4mm2 3 x 6mm2 3 x 10mm2 3 x 16mm2 3 x 25mm2 3 x 25mm2 3 x 35mm2 3 x 50mm2 3 x 70mm2 3 x 95mm2

Earth line MCB

1.5mm2 2.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 25mm2 35mm2 50mm2 70mm2 95mm2

20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A

Creepage Signal Protector Line

30mA less

n x

than 0.1 sec 0.5mm2

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

7.7 Controller Interface Diagram

No.

Sign

Meaning

01

RO 01

Compressor (output 220230VAC)

02

RO 02

Water Pump (output 220230VAC)

03

RO 03

4-way valve (output 220230VAC)

04

RO 04

Fan (output 220-230VAC)

05

RO 05

Reserved

06

RO 06

Anti-freezing heater (output 220-230VAC)

07

RO 07

Crankshaft Heater (output 220230VAC)

08

RO 08

Spray Valve (output 220230VAC)

09

RO 09

Electric Auxiliary Heater (output 220-230VAC)

10

RO 10

Reserved

12

RO 11

Alarm (output 220-230VAC)

12

RO 12

Hot Water Pump

13

RO 13

Electromagnetic three-way valve

14 RO 14~RO18 Reserved

15

AC-L

Live Wire (output 220-230VAC)

16

AC-N

Neutral Wire (output 220230VAC)

17

AI01

Water Inlet Temperature (input)

18

AI02

Water output temperature (input)

19

AI03

System exhaust temperature (input)

20

AI04

Reserved

21

AI05

System suction temperature (input)

22

AI06

System coil temperature (input)

23

AI07

Ambient temperature (input)

24

AI08

Water tank temperature (input)

25

AI09-AI20 Reserved

26

AI21

Suction pressure input

27

AI22

Exhaust pressure input

28

DI01

System high pressure (input)

29

DI02

System low pressure (input)

30

DI03

Water flow switch (input)

31

DI04

Emergency switch (input)

32

DI05

Mode switch (input)

33

DI06

Master-slave machine switch (input)

34

DI07

Electric heating overload protection switch (input)

35

485_A1

Frequency Conversion Board Communications

36

485_B1

Frequency Conversion Board Communications

37

485_A2

Communicate with wire controller and DC fan module

38

485_B2

Communicate with wire controller and DC fan module

39

485_A3

Reserved

40

485_B3

Reserved

41

12V

12V (output)

42

5V

5V (output)

43

CN1

Electronic expansion valve

44

CN2-CN4 Reserved

Page 14 Evo Flex Series Manual

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

8. Maintenance

Page 15 Evo Flex Series Manual

DO I NEED TO GET MY UNIT SERVICED?

It is recommended that you get your EvoHeat unit serviced once a year by your local certified air conditioning or refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary. During the service, they will check the operational pressures of the refrigeration system and give the unit and fins a good clean to ensure maximum performance.

DO WE HAVE RECOMMENDED SERVICE AGENTS?

EvoHeat have a large database of recommended service agents. Please contact EvoHeat tech support on 1300 859 933 for your local service agent details.

SHOULD I CHECK MY UNIT REGULARLY?

We recommend you check your unit regularly to avoid potential issues and damage to your heat pump.

Check the water inlet/outlets often for leaks. You should avoid the condition of no water or air entering into the system, as this will influence unit's performance and reliability.

The area around the unit should be dry, clean and well ventilated. Make sure there is nothing blocking the airflow of the heater e.g. Leaf litter. Clean the heat exchanger every few months to keep a good heat exchange rate and save energy.

WHAT SHOULD I BE CHECKING REGULARLY?

You should discharge the water at the bottom of the water pump if the unit will not be used for an extended period. Discharge all water in the water pump and water system so that freezing of the water in the pump or water system does not occur. Check the unit thoroughly and fill the system with water fully before using it for the first time after a period of time.
Check the power supply and cable connection often, should the unit begin to operate abnormally, switch it off and contact the qualified technician

Clean the water filter periodically to maintain good water quality. Lack of water and dirty water can damage the unit. The heat pump will start the water every 72 hours when it is not running to avoid freezing.

The water loop of the heat pump MUST be protected from freezing in winter. Do not shut off the power supply to the heat pump in winter. When the air temperature is below 0°C, if the inlet water temperature is above 2°C and below 4°C the water pump will begin freezing protection. If the inlet water is lower than 2°C, the heat pump will begin heating.

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

9. Warranty

Refer to the EvoHeat website for warranty details

·

Australia: https://evoheat.com.au/warranty-terms/

·

South East Asia: http://evoheat.com.sg/warranty/

Page 16 Evo Flex Series Manual

1. Warranty terms are from date of purchase.
2. This warranty excludes any defect or injury caused by or resulting from misuse, abuse, neglect, accidental damage, improper voltage, vermin infestation, incompetent installation, any fault not attributable to faulty manufacture or parts, any modifications which affect the reliability or performance of the unit.
3. This warranty does not cover the following:
a. Natural Disasters (hail, lightening, flood, fire etc.) b. Rust or damage to paintwork caused by a corrosive atmosphere c. When serviced by an unauthorized person without the permission of Evo Industries d. When a unit is installed by an unqualified person e. Where a unit is incorrectly installed f. When failure occurs due to improper or faulty installation g. Failure due to improper maintenance (refer Operating Instructions) h. `No Fault Found' service calls where the perceived problem is explained within the i. Costs associated with delivery, handling, freighting, or damage to the product in transit.
4. If warranty service is required, you should:
a. contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b. provide a copy of your receipt as proof of purchase c. have completed the online Warranty Registration Form
5. Onsite technical service is available within the normal operating area of your Evo Authorised Service Agents. Service outside this area will incur a traveling fee.
6. Unless otherwise specified to the purchaser, the benefits conferred by this express warranty and additional to all other conditions, warranties, rights and remedies expressed or implied by the Trade Practices Act 1974 and similar consumer protection provisions contained in legislation of the States and Territories and all other obligations and liabilities on the part of the manufacturer or supplier and nothing contained herein shall restrict or modify such rights, remedies, obligations or liabilities.

REGISTER YOUR WARRANTY
EvoHeat highly recommend customers complete their warranty details online to ensure efficient warranty claim processing.
To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/

info@evoheat.com.au

1300 859 933

www.evoheat.com.au

