Towel rails with nominal heat output of >60W and ≤250W
Brand: Warmup
EcoDesign Compliance Information
This product is a towel rail with an output of >60 W and ≤250 W. To meet the mandatory EcoDesign requirements set by Commission Regulation (EU) 2024/1103, it must be supplemented with control functions providing at least the following control features:
Type of heat output / room temperature regulation (one of them)
- TE - Electronic room temperature regulation (requires at least 1 additional regulation option)
- TD - Electronic room temperature regulation plus daily timer
- TW - Electronic room temperature regulation plus weekly timer
Further regulation options (multiple selection possible)
- f2 - Open window detection
- f4 - Adaptive start control
- f5 - Operating time limitation
- f7 - Learning function
- f8 - Control accuracy
Example of permissible control function codes
| Control Type | Permissible Codes | Example Control |
|---|---|---|
| TE | (f8) | Manual thermostat |
| TW | (f4/f8) | 7-day programmable thermostat |
| TW | (f2/f3/f4/f8) | Smart WiFi thermostat |
EcoDesign Compliance Information Card
This EcoDesign card must remain permanently attached near the appliance. This product is a towel rail with an output of >60 W and ≤250 W. To meet the mandatory EcoDesign requirements set by Commission Regulation (EU) 2024/1103, it must be supplemented with control functions providing at least the following control features:
Nominal heat output: 60W < Pnom ≤ 250W
| Type of heat output / room temperature regulation (one of them) | Regulation Code (TC) | Note |
|---|---|---|
| Single level without temperature control | NC | N/A |
| Electronic room temperature control | TE | 1* |
| Electronic room temperature control plus daily timer | TD | 0* |
| Electronic room temperature control with weekly timer | TW | 0* |
* = Minimum number of additional regulation options required for each type of heat output / room temperature regulation.
Further regulation options (multiple selection possible)
| f2 - Open window detection | [✓] |
| f4 - Adaptive start control | [ ] |
| f5 - Operating time limitation | [ ] |
| f7 - Learning function | [ ] |
| f8 - Control accuracy | [ ] |
Energy consumption for room temperature regulation
Regulation must include off mode and/or standby mode in addition to the standby mode. Energy consumption must comply with the requirements for each mode, as appropriate.
- Off mode: Poff ≤ 0.5W
- Standby mode (select one):
- Psm ≤ 0.5W (if the controller has an active display in standby mode)
- Pdsm ≤ 1.0W (if the controller has an active display in standby mode)
- Pnsm ≤ 2.0W (if the controller has network connection in standby mode)
- Idle mode (select one):
- Pidle ≤ 1.0W (if the controller has network connection)
- Pnidle ≤ 3.0W (if the controller has network connection)
Warmup Thermostats with Control Function Codes and Energy Consumption
The following Warmup thermostats contain these control function codes and energy consumption:
| Thermostat Model | Control Function Codes | Energy Consumption | |||||
|---|---|---|---|---|---|---|---|
| Poff ≤ 0.5W | Psm ≤ 0.5W | Pdsm ≤ 1.0W | Pnsm ≤ 2.0W | Pidle ≤ 1.0W | Pnidle ≤ 3.0W | ||
| Tempo | TW (f4/f8) | ✔ | ✔ | ✔ | ✔ | ||
| Element | TW (f2/f3/f4/f8) | ✔ | ✔ | ✔ | ✔ | ||
| 6iE / 7iE | TW (f2/f3/f4/f8) | ✔ | ✔ | ✔ | ✔ | ||
The combined heat output of all local electric space heaters connected to individual control can be found on the technical specifications page in this manual.
Heated Towel Rail
If you use alternative thermostats, the above card must be filled in according to the definitions of control function codes specified in Regulation (EU) 2024/1103 to ensure compatibility with this local electric space heater. Only functions that are active when the control element is put into operation can be declared above and used for compliance.
| Model | Power (kW) | Model | Power (kW) |
|---|
Control Function Codes and Mapping
Further Regulation Options
- f2 - Open window detection
- f4 - Adaptive start control
- f5 - Operating time limitation
- f7 - Learning function
- f8 - Control accuracy
Control Function Codes Mapping
This table shows the mapping between temperature control types, their codes (TC), and the associated control functions (f1-f8) as required by Regulation (EU) 2024/1103.
| Type of temperature control | Temperature controller code (TC) | Control functions | |||||||
|---|---|---|---|---|---|---|---|---|---|
| f1 | f2 | f3 | f4 | f5 | f6 | f7 | f8 | ||
| Single level without temperature control | NC | ||||||||
| Two or more manual levels without temperature control | TX | ||||||||
| Room temperature control with mechanical thermostat | TM | ||||||||
| Electronic room temperature control | TE | ✔ | ✔ | ||||||
| Electronic room temperature control with daily timer | TD | ✔ | ✔ | ||||||
| Electronic room temperature control with weekly timer | TW | ✔ | ✔ | ✔ | ✔ | ✔ | |||
The table below provides details on specific control functions and their typical associated TC codes:
| Control Function | Code | Typical Associated TC Code(s) |
|---|---|---|
| Presence detection | f1 | |
| Open window detection | f2 | TW |
| Remote control possibility | f3 | TW |
| Adaptive start control | f4 | TW |
| Operating time limitation | f5 | TW |
| Black bulb sensor | f6 | |
| Learning function | f7 | TE, TD, TW |
| Control accuracy with CA < 2 Kelvin and CSD < 2 Kelvin | f8 | TE, TD, TW |