LG Air Conditioner Owner's Manual
Model: MFL69781202
Type: WALL MOUNTED
Read this owner's manual thoroughly before operating the appliance and keep it handy for reference at all times.
Copyright © 2017 - 2021 LG Electronics Inc. All Rights Reserved. Visit: www.lg.com
Safety Precautions
IMPORTANT SAFETY PRECAUTION
Notes for Precaution
- The appliance shall be installed in accordance with national wiring regulations.
- Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard.
- For more information on installation, please refer to the installation manual provided.
- The installation manual includes: Instructions for safe use, precautions during user maintenance, necessary space dimensions for installation, method of connection/disconnection, fuse/circuit breaker details, and fixing instructions.
- The service manual includes: A wiring diagram with connections to external control devices and supply cord.
For R32 Refrigerant
- Minimize pipe-work installation and protect it from physical damage.
- Observe national gas regulations.
- Ensure mechanical connections are accessible for maintenance.
- Keep ventilation openings clear of obstructions.
- Personnel working on the refrigerant circuit must hold a valid certificate for handling refrigerants.
- Servicing should only be performed as recommended by the manufacturer.
- Store the appliance in a well-ventilated area appropriate for its operation.
- Do not store in rooms with open flames or ignition sources.
- Store to prevent mechanical damage.
- The installation manual provides details on refrigerant charge amount and handling, installation, cleaning, servicing, and disposal.
- The service manual provides the minimum rated airflow.
Safety Instructions
The following safety guidelines prevent unforeseen risks or damage from unsafe or incorrect operation.
Symbols:
- ⚠️ (Risk Symbol): Indicates matters and operations that can cause risk. Follow instructions carefully.
- WARNING: Failure to follow instructions can cause serious injury or death.
- CAUTION: Failure to follow instructions can cause minor injury or product damage.
Symbols on Units:
- ? (Flammable Refrigerant): Indicates the appliance uses a flammable refrigerant. Leakage and exposure to ignition sources pose a fire risk.
- ? (Read Manual): Indicates the Operation Manual should be read carefully.
- ?️ (Service Personnel): Indicates service personnel should handle equipment with reference to the Installation Manual.
- ℹ️ (Information Available): Indicates information is available in the Operating or Installation Manual.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
- Installation: Do not install on unstable surfaces. Contact an authorized service center for installation/relocation. Install control box panel safely. Do not install where flammable liquids/gases are stored. Ensure pipes and cables are not pulled too tight. Use appropriate circuit breakers/fuses. Do not input air/gas other than specified refrigerant. Use non-flammable gas (nitrogen) for leak checks. Secure wiring connections tightly.
- Operation: Use only specified parts; do not modify. Ensure children do not climb on or hit the outdoor unit. Dispose of batteries safely. Use only specified refrigerant. Cut off power if noise, smell, or smoke occurs. Keep flammable substances away. Contact service if submerged in flood water. Do not use in small spaces without ventilation. Ventilate sufficiently after gas leaks. Contact service for interior cleaning. Ventilate when using with heating appliances. Do not block air flow. Do not insert objects into air inlets/outlets. Ensure power cable is in good condition. Never operate with wet hands.
- Maintenance/Safety: Do not place objects on the power cable. Do not place heaters near the power cable. Do not modify/extend power cables. Cut off power during blackouts/thunderstorms. Ensure power cable is not pulled out or damaged. Do not touch refrigerant/water pipes or internal parts during/after operation. Do not clean by spraying water directly. Disconnect power before cleaning/maintenance. Installation/repairs by unauthorized persons are hazardous.
- General: Information is for qualified service technicians. Failure to follow instructions can lead to malfunction, damage, injury, or death. Power cord replacement must be done by authorized personnel with genuine parts. Ensure proper grounding to minimize electric shock risk. Do not remove grounding prong. Attaching earth wire to cover screw does not ground unless specific conditions are met. Consult an electrician if unsure about grounding. Refrigerant and blowing gas require special disposal procedures.
CAUTION
- Installation: Do not install in areas exposed to sea wind (salt spray). Install drain hose properly. Exercise caution during unpacking/installation. Do not touch leaking refrigerant. Transport with two or more people or use a forklift. Protect outdoor unit from direct sunlight. Do not place indoor unit where exposed to sunlight via windows. Dispose of packing materials safely. Install away from neighbors' inconvenience due to noise or fumes.
- Operation: Remove batteries from remote control if not used for an extended period. Ensure filter is installed. Check for refrigerant leaks. Do not place objects on the unit. Do not mix battery types. Do not run for long periods in high humidity with open doors/windows. Stop using remote if battery leaks; wash skin if exposed. Do not expose people/animals/plants to cold/hot wind for extended periods. If battery fluid is swallowed, rinse mouth and consult a doctor. Do not drink drained water. Do not use for special purposes (preserving food, art); it's for consumer use. Do not recharge or disassemble batteries.
- Maintenance: Never touch metal parts when removing the air filter. Use a sturdy stool/ladder for work at height. Never use strong cleaning agents/solvents or spray water; use a smooth cloth.
Operation
Notes for Operation
Suggestion for Energy Saving
- Do not over-cool; it's harmful and consumes more electricity.
- Block sunlight with blinds or curtains.
- Keep doors/windows closed tightly.
- Adjust air flow direction vertically or horizontally to circulate air.
- Use higher fan speed for quick cooling/warming.
- Open windows regularly for ventilation; indoor air quality may deteriorate with prolonged use.
- Clean the air filter every 2 weeks to maintain performance.
- For Australia/New Zealand: Complies with AS/NZS 4755.3.1 for DRM1, DRM2, DRM3 models (Optional).
Parts and Functions
Indoor Unit:
- 1 Air Filter
- 2 Air Intake
- 3 Front Cover
- 4 Air Outlet
- 5 Air Deflector (Horizontal Vane)
- 6 Air Deflector (Vertical Louver)
- 7 On/Off Button
Outdoor Unit:
- 1 Air Intake Vents
- 2 Air Outlet Vents
Note: Operation lamp numbers/locations and features may vary by model.
Wireless Remote Control
Inserting Batteries:
- Remove the battery cover.
- Insert AAA (1.5 V) batteries, ensuring correct polarity (+/-).
Operating Method: Point the remote control towards the signal receiver on the right side of the air conditioner.
Installing the Remote Control Holder:
- Choose a safe, accessible location away from direct sunlight.
- Fix the holder with 2 screws.
Note: The remote may affect other electronic devices if pointed at them. Use a soft cloth to clean the signal transmitter/receiver. Some functions may not produce a buzzer sound if not supported by the product.
Setting the Current Time:
- Insert batteries. The time icon blinks.
- Press `^` or `v` buttons to select minutes.
- Press SET/CANCEL to finish. (On/Off Timer is available after setting the current time.)
Using the °C/°F Conversion Function (Optional): Press and hold the SWING button for about 5 seconds.
Operating the Air Conditioner without the Remote Control:
- Open the front cover (Type2) or horizontal vane (Type1).
- Press the ON/OFF button.
Note: Stepping motor may break if vane opens rapidly. Fan speed is set to high. Temperature cannot be altered. For cooling-only models, temp is 22°C; for cooling & heating, 22°C to 24°C.
Using Wireless Remote Control:
The remote control operates various functions:
- ON/OFF Button: Turns the air conditioner on/off.
- TEMP Buttons (`^`/`v`): Adjusts desired room temperature.
- MODE Button: Selects Cooling, Heating, Dehumidification, Fan, or Auto Operation mode.
- JET MODE Button: Changes room temperature quickly.
- FAN SPEED Button: Adjusts fan speed.
- SWING Button: Adjusts air flow direction vertically or horizontally.
- TIMER Button: Sets On/Off timer.
- SET/CANCEL Button: Sets/cancels functions and timers.
- LIGHT OFF Button: Adjusts display screen brightness.
- ENERGY SAVING Button: Minimizes power consumption.
- COMFORT AIR Button: Adjusts air flow to deflect wind.
- ENERGY CTRL Button: Controls power saving steps.
- COMFORT SLEEP Button: Creates a comfortable sleeping environment.
- DIAGNOSIS Button: Checks maintenance information.
Note: Buttons may vary by model.
Restarting the Air Conditioner Automatically
This function restores previous settings after a power failure.
Disabling Auto Restart: Open front cover/vane, press and hold ON/OFF for 6 seconds (unit beeps twice, lamp blinks 4 times). Re-enable by repeating the process.
Note: Holding ON/OFF for 3-5 seconds initiates test operation (strong cooling for 18 mins).
Using the Mode Function:
Cooling Only Model: Cooling Mode, Auto Operation (AI) Mode, Dehumidification Mode, Fan Mode.
Cooling & Heating Model: Cooling Mode, Auto Changeover Mode, Dehumidification Mode, Heating Mode, Fan Mode.
Cooling Mode: Turn on, press MODE repeatedly, display shows `❄️`, adjust temp with `^`/`v`.
Auto Operation (AI) Mode: Automatically sets fan speed and temperature based on room temp. Display shows `A`.
Auto Changeover Mode: Automatically maintains set temperature ±2°C. Display shows `(A)`. Adjust fan speed with FAN SPEED.
Dehumidification Mode: Removes excess moisture. Display shows `?`. Compressor/fan may not operate below 24°C.
Heating Mode: Turn on, press MODE, display shows `☀️`, adjust temp with `^`/`v`. Unit may show `?` during defrosting or preheating.
Fan Mode: Circulates indoor air without changing temperature. Display shows `?️`. Fan speed adjustable.
Using the Jet Mode Function: Cools or warms air quickly.
- Available in Cooling, Heating, Dehumidification (Cooling & Heating models).
- Available in Cooling, Dehumidification, Fan, Auto Operation, Air Purification (Cooling Only models).
- Turn on, press MODE, press JET MODE. Display shows `?`.
- Jet Cooling: Strong air for 30 mins, then maintains 18°C.
- Jet Heating: Strong air for 30 mins, then maintains 30°C.
- Jet Heating Mode may not be available on some models.
Using the Fan Speed Function: Press FAN SPEED to adjust speed (High, Medium-High, Medium, Medium-Low, Low, Natural Wind). Natural Wind adjusts automatically.
Using the Air Flow Direction Function: Press SWING button to adjust vertical/horizontal direction. Select `?` for automatic adjustment.
Note: Horizontal adjustment may vary. Arbitrary deflector adjustment can cause failure. Restarting may reset direction.
Setting the On/Off Timer: Sets the air conditioner to turn on/off automatically.
Setting the On Timer: Press TIMER, select minutes with `^`/`v`, press SET/CANCEL. `ON 6:00` icon displayed.
Setting the Off Timer: Press TIMER, select minutes with `^`/`v`, press SET/CANCEL. `OFF 6:00` icon displayed.
Note: Disabled if Simple Timer is set.
Canceling the On Timer: Press TIMER, press SET/CANCEL.
Canceling the Off Timer: Press TIMER, press SET/CANCEL.
Canceling the Timer Setting: Press CANCEL to cancel all timer settings.
Using the Sleep Function (Optional): Turns off the air conditioner automatically when you go to sleep.
- Turn on appliance.
- Press TIMER repeatedly. Icon `?` blinks.
- Press `^`/`v` to select hour (up to 7 hours).
- Press SET/CANCEL to finish. `?` icon displayed.
Note: Display shows 1H to 7H. In Cooling/Dehumidification, temp increases by 1°C after 30 mins, then another 1°C. Max increase is 2°C. Fan speed adjusts automatically.
Using the Simple Timer Function (Optional): Turns off the air conditioner automatically when you go to sleep.
- Turn on appliance.
- Press TIMER repeatedly. Icon `S` blinks.
- Press `^`/`v` to select hour (up to 7 hours).
- Press SET/CANCEL to finish. `S` icon displayed.
Note: Disabled when Off Timer is set.
Using the Energy Display Function (Optional): Displays electricity usage.
Display Current Energy Usage: Turn on, press `L8
Display Cumulative Energy Usage: Turn on, press `L8
Note: `kW` for instantaneous, `kWh` for cumulative. Max display 99 kWh. Power off resets value.
Using the Light Off Function (Optional): Press LIGHT OFF to set display screen brightness.
Using the Comfort Air Function (Optional): Sets vane to deflect air away from occupants.
- Turn on appliance.
- Press COMFORT AIR repeatedly, select direction. `?` or `➡️` displayed.
Note: Disabled when MODE or JET MODE is pressed. Disabled with SWING button (sets auto vertical swing). When off, horizontal vane operates automatically.
Using the Energy Saving Function (Optional): Minimizes power consumption in Cooling mode, raises set temp to 22°C for comfort.
- Turn on appliance.
- Press MODE for Cooling Mode.
- Press ENERGY SAVING. `❄️` displayed.
Using the Energy Control Function (Optional):
- Turn on appliance.
- Press ENERGY CTRL repeatedly to select steps.
Note: Step 1: 20% power reduction (`40%`). Step 2: 40% power reduction (`60%`). Step 3 (Optional): 60% power reduction (`80%`). Available in Cooling Mode. Capacity may decrease.
Using Special Functions:
- Turn on appliance.
- Press FUNC repeatedly to select function.
- Press SET/CANCEL to finish.
Functions include:
- Ionizer (`⚡`): Improves indoor air quality by using ions.
- Noise Reduction (`?`): Reduces noise from outdoor units.
- Ion Care (`?`): Moisturizes skin with ion clusters.
- Humidity Control (`?`): Lowers indoor humidity quickly.
- Minimum Temp (`❄️`): Maintains minimum room temp to prevent freezing.
- Mosquito Away (`?`): Scares away mosquitos with high-frequency waves.
- Moisture Removal (`?`): Removes moisture from the indoor unit.
- Comfort Sleep (`?`): Creates a comfortable sleeping environment.
Note: Functions may vary by model and may operate differently from the remote display.
Canceling Special Functions: Press FUNC to select, then SET/CANCEL.
Using the Air Purification Function: Supplies clean air via ion particles and filter.
- Ionizer: Reduces surface bacteria.
- Plasma: Removes microscopic contaminants.
Note: Can be used without turning the air conditioner on. Do not touch ionizer during operation.
Using the Silent Function: Reduces noise from outdoor units. Display shows `?`.
Note: Disabled with MODE, ENERGY CTRL, JET MODE. Available with Cooling, Heating, Auto Changeover, Auto Operation.
Using the Ion Care Function: Moisturizes skin. Display shows `?`.
Note: Available with Cooling, Fan Mode, Air Purification.
Using the Jet Dry Function: Maximizes dehumidification performance. Display shows `?` or `?`.
Note: Available with Cooling, Dehumidification, Auto Operation, Fan Mode, Air Purification. Not available with Sleep function. Disabled with MODE button.
Using the Low Heating Function: Maintains minimum room temperature and prevents freezing in unoccupied rooms.
- Display shows `?` or `LH` during operation.
- Available with Heating Mode.
- Other functions may be temporarily disabled.
- JET MODE disables this function.
Using the Mosquito Away Function: Fans away mosquitos with high-frequency waves. Display shows `?`.
Note: Can be used without turning the air conditioner on.
Using the Auto Clean Function: Removes moisture generated inside the indoor unit during Cooling/Dehumidification. Display shows `?`.
Note: Fan continues for 30 mins after unit is turned off to clean the inside.
Using the Comfort Sleep Function: Automatically adjusts for a comfortable sleep environment. Display shows `?` or `SL`.
Note: Available with Cooling Mode. Vane stops swing after 30 mins.
Smart Functions
LG ThinQ Application
This feature is available on models with the `LG ThinQ` logo. It allows communication with the appliance via a smartphone.
LG ThinQ Application Features: Communicate with the appliance using smart features.
Smart Diagnosis: Helps diagnose and solve problems.
Settings: Adjust appliance and application options.
Note: Re-register if Wi-Fi router, provider, or password changes. Application subject to change. Functions vary by model.
Before Using LG ThinQ Application:
- Check distance between appliance and Wi-Fi router. Weak signal may cause registration failure.
- Turn off mobile/cellular data on your smartphone.
- Connect smartphone to the wireless router.
Note: Verify Wi-Fi connection via `?` icon. Supports 2.4 GHz Wi-Fi only. LG ThinQ is not responsible for network issues. Use a Wi-Fi repeater if signal is weak. Network connection may be affected by home environment or ISP.
RF Radiation Exposure Statement: Install and use at a minimum distance of 20 cm from the human body.
Wireless LAN Module Specifications:
Model | Frequency Range | Output Power (Max) |
LCW-003 | 2412 MHz - 2472 MHz | IEEE 802.11b: 18.37 dBm IEEE 802.11g: 17.67 dBm IEEE 802.11n: 17.67 dBm |
LCW-007 | 2412 MHz - 2472 MHz | IEEE 802.11b: 17.59 dBm IEEE 802.11g: 17.39 dBm IEEE 802.11n(HT20): 16.64 dBm IEEE 802.11n(HT40): 17.05 dBm |
Open Source Software Notice: Obtain source code at opensource.lge.com.
Smart Diagnosis:
Available on models with `LG ThinQ` or `diag` logo. Helps diagnose and solve appliance problems.
Note: Service may not operate due to external factors (Wi-Fi unavailability, etc.). Feature may change.
Using LG ThinQ to Diagnose Issues: Launch LG ThinQ app, select Smart Diagnosis, follow instructions.
Using Audible Diagnosis to Diagnose Issues:
- Plug in the power.
- Place smartphone mouthpiece near `LG ThinQ` or `diag` logo.
- Press and hold DIAGNOSIS [5s] button for 5+ seconds while holding mouthpiece to logo until data transfer completes.
- Diagnosis will be displayed in the app.
Note: Do not move phone during transmission. Keep ambient noise minimal.
Maintenance
WARNING: Before cleaning or maintenance, disconnect power and wait for the fan to stop.
If the air conditioner will not be used for an extended period, dry it to maintain best condition. Clean regularly for optimal performance and to prevent breakdown.
- Dry the air conditioner in Fan mode for 3-4 hours and disconnect power. Moisture left inside can cause internal damage.
- Before using again, dry inner components in Fan mode for 3-4 hours to remove odors from moisture.
Filter Cleaning Schedule:
Type | Description | Interval |
Air filter | Clean with vacuum or hand wash. | 2 weeks |
Triple filter | Clean with vacuum or brush. | Every 3 months |
Micro dust filter | Clean with vacuum or brush. | Once a month |
Allergy filter | Clean with vacuum or brush. | Every 6 months |
Ionizer (Optional) | Use dry cotton bud to remove dust. | Every 6 months |
Indoor unit surface | Clean with a soft, dry cloth. | Regularly |
Condensate drain pan | Professional cleaning. | Once a year |
Condensate drain pipe | Professional cleaning. | Every 4 months |
Remote control batteries | Replace. | Once a year |
Heat exchanger coils & panel vents | Professional cleaning (Consult technician). | Once a year |
Fan | Professional cleaning. | Once a year |
Outdoor unit condensate drain pan | Professional cleaning. | Once a year |
Fan assembly | Professional verification of tightening. | Once a year |
Electric components | Clean with air. | Once a year |
Note: Never use water > 40°C or volatile substances for cleaning filters. Do not wash Micro dust, Triple, or Allergy filters with water.
Clean the Air Filter:
Clean air filters every 2 weeks or as needed.
Note: Filter can break if bent. Incorrect assembly allows dust entry.
Type 1 Filter Removal/Cleaning:
- Turn off power.
- Hold filter knobs, lift slightly.
- Remove from indoor unit.
- Clean with vacuum cleaner or lukewarm water with neutral detergent.
- Dry in shade.
- Insert filter hooks into front cover.
- Push down hooks to assemble.
- Check front cover for correct assembly.
Type 2 Filter Removal/Cleaning:
- Turn off power.
- Open front cover (lift sides slightly).
- Hold filter knobs, pull down slightly, remove from indoor unit.
- Clean with vacuum cleaner or lukewarm water with neutral detergent.
- Dry in shade.
- Insert filter hooks into front cover.
- Check front cover for correct assembly.
Clean the Micro dust, Triple and Allergy Filter (Optional):
- Turn off power.
- Remove air filters from indoor unit.
- Remove Micro dust, Triple, and Allergy filter.
- Clean filter with a vacuum cleaner.
- Insert the filter.
- Assemble air filters.
- Check front cover for correct assembly.
Note: Filter features and location may vary by model.
Troubleshooting
Self-diagnosis Function: If an error occurs, the indoor unit lamp blinks every 2 seconds. Contact dealer/service center.
Before Calling for Service: Check the following:
Symptoms | Possible Causes & Solution |
The air conditioner does not work normally. |
|
The air conditioner does not work. |
|
The air conditioner does not emit cool air. |
|
The fan speed cannot be adjusted. |
|
The temperature cannot be adjusted. |
|
The air conditioner stops during operation. |
|
Indoor unit still operating after being turned off. |
|
Air outlet discharging mist. |
|
Water leaks from outdoor unit. |
|
Noise or vibration. |
|
Indoor unit gives off an odor. |
|
Air conditioner does not emit warm air. |
|
Home appliance and smartphone not connected to Wi-Fi network. |
Note: Some functions may not be supported by model. |