Owner's Manual for Mircom models including: i3 SERIES 2-Wire Loop Test-Maintenance Module, i3 SERIES, 2-Wire Loop Test-Maintenance Module, Loop Test-Maintenance Module, Test-Maintenance Module, Maintenance Module, Module
Mircom CAT-5129 i3 Series 2-wire Loop Test Maintenance Module (English) - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 2 Pages, 799.96KB
DocumentDocument2-WIRE LOOP TEST/MAINTENANCE MODULE i3 SERIES Features · Allows all 2-wire i3TM detectors to be used on any compatible 2 or 4-wire fire alarm control panel · Interprets the i3 remote maintenance signal · Provides visual indication and an output relay when a detector on the loop requires cleaning · Initiates the EZ Walk loop test · Provides Style D wiring on IDC loops · Green, red, and yellow LEDs indicate Loop communication status Maintenance alert Freeze trouble Alarm EZ Walk test enabled Wiring fault · Mounts to 4"-square back box · Durable terminal blocks with SEMS screws Description The 2W-MOD2 two-wire loop test/maintenance module maximizes the benefits of the i3TM series smoke detectors, by offering detector remote maintenance signaling and EZ Walk loop testing capabilities. Installation Ease The 2W-MOD2 mounts to a 4"-square back box for quick and easy installation. Terminal blocks with durable SEMS screws assure a reliable connection. Intelligence The 2W-MOD2 allows communication to 2-wire i3 detectors with any listed fire alarm control panel. This in turn enables i3 detectors to initiate a remote maintenance signal when they are in need of cleaning, and to provide a visual indication of this condition at the module and at the panel. The 2W-MOD2 also features the EZ Walk loop test for 2-wire i3 series detectors. This function verifies the entire initiating loop wiring with just the press of a button. Engineering Specifications Loop test/maintenance module shall be an i3 series model number 2W-MOD2, listed to Underwriters Laboratories UL 864 for Control Units for Fire Protection Signaling Systems. The module shall include provisions for mounting to 4-inch square back boxes. Wiring connections shall be made by means of SEMS screws. The module shall provide three LED indicators which will blink or illuminate to indicate communication status, maintenance alert, alarm or freeze trouble conditions, and EZ Walk loop test mode. The module shall allow communication to 2-wire i3 detectors with any UL listed fire alarm control panel. The 2W-MOD2 shall offer provisions for Style D wiring on IDC loops, and shall provide a loop testing capability to verify the initiating loop wiring. Mounting Instant Inspection The 2W-MOD2 includes three LEDs -- green, red, and yellow -- that provide status indication for the loop. These LEDs indicate the following: Loop communication status Maintenance alert Alarm Freeze trouble EZ Walk test enabled Wiring fault The 2W-MOD2 mounts directly to 4" square electrical boxes. MEA approved 5129 CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. firealarmresources.com Electrical Specifications Operating Voltage Nominal: 12/24 V Min.: 8.5 V power limited Max.: 35 V power limited Maximum Ripple Voltage 30% of nominal (peak to peak) Maximum Standby Current 30 mA Maximum Alarm Current 90 mA Max. Maintenance Current 53 mA Alarm Contact Ratings 0.5 A @ 36VDC, Resistive Maintenance Contact Ratings 2 A @ 30VDC, Resistive LED Modes LED Color Status Green LED Red LED On Blinking 1 sec. on / 1 sec. off Off On Blinking 1 sec. on / 1 sec. off On Yellow LED Blinking 0.5 sec. on / 0.5 sec. off Condition Power on. Detectors on loop do not have communication capability. Power on. Detectors on loop are communicating normally. Power not applied or module not in operation. Detector on loop in alarm. One or more detector on loop is in need of maintenance or is in freeze trouble. Loop wiring fault exists. EZ Walk test mode. Power Up Sequence for LED Indication Condition Initial LED status indication EZ Walk test available Duration 2 minutes 6 minutes after reset Physical Specifications Operating Temperature Range 14°F122°F (10°C to 50°C) Operating Humidity Range 0 to 95% RH non-condensing Input Terminals 1422 AWG Dimensions Height: 4.5 inches (114 mm) Width: 4.0 inches (101 mm) Depth: 1.25 inches (32 mm) Weight 8 oz. (225 grams) Mounting 4-inch square back box Ordering Information Model 2W-MOD2 Description 2-wire loop test/maintenance module for 2-wire i3 Series standard, sounder and Form C relay smoke detectors NOT TO BE USED FOR INSTALLATION PURPOSES. Distributed by: Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com firealarmresources.com CAT. 5129 Rev. 4