Fujitsu FF***TS92 Series Multi-Position Gas Furnace

This document provides detailed specifications, features, and technical information for the Fujitsu FF***TS92 Series of multi-position gas furnaces. These furnaces are designed for efficient and reliable heating, offering 92% Annual Fuel Utilization Efficiency (AFUE).

Key Features

Standard Equipment

Completely assembled and wired units include: blocked drain sensor, 7-segment LED, marked hoses, heat exchanger (primary: aluminized steel, secondary: 29-4C stainless steel), solid bottom, induced draft, pressure switches, redundant main gas control, blower compartment door safety switch, solid-state time-on/off blower control, limit controls, manual shut-off valve, 100% safety lockout, cool fan off delay, field-selectable heat fan off delay, one-hour automatic retry, power and self-test diagnostics, flame sense current diagnostics, electronic air cleaner connections, twinning features, humidifier connections, humidifier on/off delay, low-speed continuous fan option, single-speed option for heating and cooling, transformer, and a direct-drive, multi-speed Constant Torque electrically commutated motor. A thermostat is not included as standard equipment.

Optional Equipment

Optional accessories include side and bottom filter racks, and return air cabinets for all sizes. Note: This furnace is not listed for use with fuels other than natural or L.P. (propane) gas. All models can be converted to L.P. (propane) gas by a qualified distributor or local service dealer without changing burners. Factory-approved kits are required for conversion and can be ordered as optional accessories. Refer to the Conversion Kit Index Form for L.P. (propane) operation details.

WARNING: THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES.

Component Overview

The diagram illustrates the internal layout of the Fujitsu gas furnace, highlighting key components such as the Primary and Secondary Heat Exchanger, In-Shot Burners, Pressure Switches, Control Board, Constant Torque Electrically Commutated Motor, Blocked Drain Sensor, Remote Sensor, Direct Spark Ignition, Gas Valve and Manifold, and Draft Inducer.

Physical Data and Specifications (Upflow Models)

The following table details the specifications for U.S. and Canadian models:

MODEL NUMBERS FF40173TS92M FF60173TS92M FF70173TS92M FF85215TS92M FF100215TS92M FF115245TS92M
HIGH FIRE INPUT BTU/HR [kW] 42,000 [12.31] 56,000 [16.41] 70,000 [20.50] 84,000 [24.61] 98,000 [38.71] 112,000 [32.82]
HEATING CAPACITY BTU/HR [kW] 40,320 [11.82] 53,760 [15.75] 67,200 [19.68] 80,640 [23.63] 94,080 [37.16] 107,520 [31.51]
HIGH ALTITUDE OUTPUT 10% DERATE [kW] 36,288 [10.64] 48,384 [14.18] 60,480 [17.72] 72,576 [21.28] 84,672 [24.81] 96,768 [28.36]
BLOWER (D x W) [mm] 11 x 7 [279 x 178] 11 x 8 [279 x 203] 11 x 8 [279 x 203] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 11 [279 x 279]
MOTOR H.P. [W] TYPE 1/2 [373]-5-Constant Torque ECM 1/2 [373]-5-Constant Torque ECM 1/2 [373]-5-Constant Torque ECM 1 [746]-5-Constant Torque ECM 1 [746]-5-Constant Torque ECM 1 [746]-5-Constant Torque ECM
MIN. CIRCUIT AMPACITY 8.00 10.00 10.00 13.00 15.00 14.00
MIN. OVERLOAD PROTECTION DEVICE 15.00 15.00 15.00 20.00 20.00 20.00
MAX. OVERLOAD PROTECTION DEVICE 15.00 15.00 15.00 20.00 20.00 20.00
MOTOR FULL LOAD AMPS 4.0 6.8 6.8 8.3 8.3 8.3
HEATING SPEED MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH
COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH
MINIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa] .18 [.045] .20 [.050] .23 [.057] .28 [.070] .28 [.070] .28 [.070]
MAXIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224]
HEATING CFM @ .2" [.049 kPa] W.C. E.S.P. [L/s] 982 [463] 913 [431] 1113 [525] 1574 [743] 1651 [779] 1524 [719]
COOLING CFM @ .5" [.124 kPa] W.C. E.S.P. [L/s] 1239 [585] 1227 [579] 1198 [565] 1833 [865] 1975 [932] 1748 [825]
TEMPERATURE RISE-HIGH FIRE RANGE IN DEGREES °F [°C] 25 - 55 [14 -31] 35 - 65 [19 - 36] 40 - 70 [22 - 39] 35 - 65 [19 - 36] 35 - 65 [19 - 36] 45 - 75 [25 - 42]
APPROX. SHIPPING WEIGHT (LBS.) [kg] 123.5 [56] 128 [58] 132 [60] 147.5 [67] 152 [69] 165 [75]
AFUE 92.00% 92.00% 92.00% 92.00% 92.00% 92.00%

AFUE (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

Notes: All models are 115V, 60HZ, 1 phase. Gas connection size for all models is 1/2" [13 mm] N.P.T. Installation instructions for high altitude derate. Canadian installations only. In accordance with D.O.E. test procedures. *S=Standard Models.

Note: Standard models comply with California low NOx requirements. This furnace does not meet air district requirements of 14 ng/J NOx emissions limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program (www.CleanAirFurnaceRebate.com). This furnace is to be installed for propane firing only in air districts requiring 14 ng/J NOx emission limits. Operating in natural gas mode is in violation of these Rules.

Model Number Identification

The model number indicates specific product characteristics:

Component Meaning
FF Product (Furnace)
40, 60, 70, 85, 100, 115 Capacity (e.g., 40 = 42,000 BTU/HR [12.31 kW])
17, 21, 24 Width (e.g., 17" = 17 inches)
3, 5 Airflow (3 = 3 Ton, 5 = 5 Ton)
T Motor Type (T = Constant Torque)
S Speed (S = Single Stage)
92 Efficiency (92 = 92% AFUE)
M Orientation (M = Multipoise)

Dimensional Data

Dimensional drawings provide front, bottom, top, left, and right views of the furnace, detailing measurements and required clearances to combustibles. The tables below list minimum clearances and flange dimensions for various models.

Minimum Clearances to Combustibles (Inches [mm])

MODEL LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP WGTS. [kg]
FF4017 0 0 0 1 [25] 2 [51] 0 123.5 [56]
FF6017 0 0 0 1 [25] 2 [51] 0 128 [58]
FF7017 0 0 0 1 [25] 2 [51] 0 132 [60]
FF8521 0 0 0 1 [25] 2 [51] 0 147.5 [67]
FF10021 0 0 0 1 [25] 2 [51] 0 152 [69]
FF11524 0 0 0 1 [25] 2 [51] 0 165 [75]

*A service clearance of at least 24" is recommended in front of all furnaces. Supply and return depicted as upflow configuration. Flange configuration will vary depending on installation orientation.

Flange Dimensions

MODEL A B C
FF4017 17 1/2 [445] 16 17/64 [413] 16 13/64 [412]
FF6017 17 1/2 [445] 16 17/64 [413] 16 13/64 [412]
FF7017 17 1/2 [445] 16 17/64 [413] 16 13/64 [412]
FF8521 21 [533] 19 49/64 [502] 19 45/64 [500]
FF10021 21 [533] 19 49/64 [502] 19 45/64 [500]
FF11524 24 1/2 [662] 23 17/64 [591] 23 13/64 [589]

Blower Performance Data

The following table provides blower performance data, including CFM [L/s] air delivery at various external static pressures for different motor speeds and taps. Shaded cells indicate acceptable static pressures for heating speed. Installer must verify static pressure and furnace operation within the published rise range.

FURNACE MODEL BLOWER SIZE [mm] MOTOR H.P. [W] MOTOR TAP MOTOR LEAD WIRE COLOR SPEED 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 0.8 [.19] 0.9 [.22]
FF40173 TS92M 11 x 7 [279 x 178] 1/2 [373] 1 Red Low 874 [413] 820 [387] 765 [361] 710 [335] 658 [311] 575 [271] 523 [247] 482 [228] 448 [211]
2 Yellow Medium Low* 1029 [486] 982 [463] 930 [439] 881 [416] 833 [393] 780 [368] 716 [338] 665 [314] 621 [293]
3 Purple Medium 1098 [518] 1055 [498] 1008 [476] 962 [454] 920 [434] 870 [411] 822 [388] 755 [356] 705 [332]
4 Blue Medium High** 1253.6 [592] 1209.1 [571] 1164.4 [550] 1128.1 [532] 1082.2 [511] 1043.7 [493] 1000 [472] 960 [453] 907.2 [428]
5 Black High 1380.6 [652] 1345.5 [635] 1313.1 [620] 1276 [602] 1239.2 [585] 1202.3 [567] 1166 [550] 1132.7 [535] 1098.9 [519]
FF60173 TS92M 11 x 8 [279 x 203] 1/2 [373] 1 Red Low 818 [386] 766 [362] 720 [340] 668 [315] 594 [280] 548 [259] 494 [233] 444 [210] 416 [196]
2 Yellow Medium Low* 968 [457] 913 [431] 885 [418] 841 [397] 796 [376] 739 [349] 685 [323] 641 [303] 596 [281]
3 Purple Medium 1018 [480] 981 [463] 931 [439] 903 [426] 860 [406] 815 [385] 756 [357] 703 [332] 656 [310]
4 Blue Medium High** 1173 [554] 1142 [539] 1108 [523] 1059 [500] 1025 [484] 989 [467] 951 [449] 912 [430] 855 [404]
5 Black High 1338 [631] 1327 [626] 1288 [608] 1245 [588] 1227 [579] 1193 [563] 1165 [550] 1134 [535] 1099 [519]
FF70173 TS92M 11 x 8 [279 x 203] 1/2 [373] 1 Red Low 947 [447] 908 [429] 871 [411] 834 [394] 796 [376] 755 [356] 716 [338] 681 [321] 656 [310]
2 Yellow Medium Low 1044 [493] 997 [471] 968 [457] 934 [441] 902 [426] 862 [407] 828 [391] 795 [375] 765 [361]
3 Purple Medium** 1148 [542] 1113 [525] 1092 [515] 1056 [498] 1029 [486] 995 [470] 962 [454] 928 [438] 895 [422]
4 Blue Medium High** 1213 [572] 1180 [557] 1155 [545] 1126 [531] 1096 [517] 1062 [501] 1032 [487] 993 [469] 969 [457]
5 Black High 1324 [625] 1283 [606] 1254 [592] 1221 [576] 1198 [565] 1169 [552] 1141 [538] 1107 [522] 1080 [510]
FF85215 TS92M 11 x 10 [279 x 254] 1 [746] 1 Red Low 1459 [689] 1407 [664] 1359 [642] 1297 [612] 1248 [589] 1200 [567] 1152 [544] 1102 [520] 1066 [503]
2 Yellow Medium Low* 1656 [782] 1621 [765] 1574 [743] 1533 [723] 1485 [701] 1434 [677] 1375 [649] 1328 [627] 1281 [605]
3 Purple Medium 1692 [799] 1653 [780] 1606 [758] 1557 [735] 1508 [712] 1459 [689] 1409 [665] 1363 [643] 1312 [619]
4 Blue Medium High** 1881 [888] 1831 [864] 1804 [851] 1757 [829] 1713 [808] 1668 [787] 1628 [768] 1568 [740] 1528 [721]
5 Black High 1978 [934] 1942 [917] 1906 [900] 1862 [879] 1833 [865] 1793 [846] 1751 [826] 1702 [803] 1652 [780]
FF100215 TS92M 11 x 10 [279 x 254] 1 [746] 1 Red Low 1637 [773] 1593 [752] 1545 [729] 1494 [705] 1441 [680] 1382 [652] 1329 [627] 1274 [601] 1236 [583]
2 Yellow Medium Low* 1745 [824] 1697 [801] 1651 [779] 1600 [755] 1560 [736] 1500 [708] 1443 [681] 1394 [658] 1342 [633]
3 Purple Medium 1766 [833] 1723 [813] 1686 [796] 1633 [771] 1585 [748] 1537 [725] 1482 [699] 1428 [674] 1380 [651]
4 Blue Medium High** 1967 [928] 1929 [910] 1895 [894] 1852 [874] 1805 [852] 1754 [828] 1708 [806] 1668 [787] 1612 [761]
5 Black High 2137 [1009] 2102 [992] 2062 [973] 2020 [953] 1975 [932] 1946 [918] 1908 [900] 1817 [858] 1685 [795]
FF115245 TS92M 11 x 11 [279 x 279] 1 [746] 1 Red Low 1476 [697] 1432 [676] 1406 [664] 1332 [629] 1291 [609] 1247 [589] 1207 [570] 1163 [549] 1117 [527]
2 Yellow Medium Low* 1615 [762] 1568 [740] 1524 [719] 1487 [702] 1452 [685] 1401 [661] 1356 [640] 1325 [625] 1278 [603]
3 Purple Medium** 1709 [807] 1674 [790] 1633 [771] 1591 [751] 1551 [732] 1519 [717] 1477 [697] 1436 [678] 1397 [659]
4 Blue Medium High 1772 [836] 1746 [824] 1706 [805] 1667 [787] 1627 [768] 1593 [752] 1553 [733] 1521 [718] 1482 [699]
5 Black High 1887 [891] 1852 [874] 1828 [863] 1784 [842] 1748 [825] 1713 [808] 1678 [792] 1648 [778] 1619 [764]

*Low Static Heating Speed
**High Static Heating Speed

Accessories

Various accessories are available for the FF***TS92 Series furnaces:

Vent Termination Kits

Filter Racks

MODEL RXGF-CB (UPFLOW/ HORIZONTAL) RXGF-CD (UPFLOW) RXGF-CC (DOWNFLOW)
FF4017 15 3/4 x 25 [400 x 635] 15 3/4 x 25 [400 x 635] 14 x 20 [356 x 508]
FF6017 15 3/4 x 25 [400 x 635] 15 3/4 x 25 [400 x 635] 14 x 20 [356 x 508]
FF7017 15 3/4 x 25 [400 x 635] 15 3/4 x 25 [400 x 635] 14 x 20 [356 x 508]
FF8521 19 1/4 x 25 [489 x 635] 15 3/4 x 25 [400 x 635] 14 x 20 [356 x 508]
FF10021 19 1/4 x 25 [489 x 635] 15 3/4 x 25 [400 x 635] 14 x 20 [356 x 508]
FF11524 22 3/4 x 25 [578 x 635] 15 3/4 x 25 [400 x 635] 14 x 20 [356 x 508]

Indoor Coil Casings

Other Accessories

Limited Warranty

Fujitsu General America, Inc. provides a limited warranty for replacement of parts that fail under normal use and service within the specified periods. Conditional Parts (Registration Required) are covered for Ten (10) Years. The Heat Exchanger is covered for a Limited Lifetime.

For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or Fujitsu General America, Inc. for a copy of the product warranty certificate.

Installation and Compliance Notes

Before proceeding with installation, refer to the installation instructions packaged with each model. Ensure compliance with all Federal, State, Provincial, and Local codes, regulations, and practices.

Fujitsu General America, Inc. reserves the right to make changes without notice in keeping with its policy of continuous progress and product improvement.

PDF preview unavailable. Download the PDF instead.

pdf-gfj-552-ff-ts92-03 QuarkXPress(R) 14.21

Related Documents

Preview Fujitsu FF***CS80D Downflow Gas Furnace: Features & Specifications
Explore the features, technical specifications, dimensions, and accessories of the Fujitsu FF***CS80D Downflow Gas Furnace series. Learn about its 80% AFUE rating, DSI ignition, and durable construction for residential heating.
Preview Fujitsu FF***LM98 Series Modulating Upflow Gas Furnace: Features, Specs, and Performance
Detailed information on the Fujitsu FF***LM98 Series Modulating Upflow Gas Furnace, including 98% AFUE efficiency, technical specifications, dimensions, blower performance, and accessories.
Preview Fujitsu FF***LT96 Series Two-Stage Variable Speed Gas Furnaces
Detailed specifications, features, and accessories for the Fujitsu FF***LT96 Series of two-stage, variable speed, multi-position gas furnaces, highlighting their energy efficiency, advanced technology, and installation flexibility.
Preview Fujitsu 18RLXFZH AIRSTAGE H-Series 18,000 BTU Multi Zone XLTH System Submittal Document
Technical submittal document detailing the Fujitsu 18RLXFZH AIRSTAGE H-Series 18,000 BTU Multi Zone XLTH System. Includes product features, model numbers, efficiency ratings, operational ranges, capacities, sound pressure, fan data, lineset requirements, electrical specifications, warranty information, and connectable indoor units.
Preview Fujitsu WA14 Series Air Conditioners: Specifications and Features
Comprehensive overview of Fujitsu WA14 Series air conditioners, detailing features, technical specifications, dimensions, refrigerant line sizing, performance data, and limited warranty information.
Preview Fujitsu RQPL Series Package Heat Pump: Features, Specifications, and Installation Guide
Comprehensive guide to the Fujitsu RQPL Series Package Heat Pump, detailing features, technical specifications, model identification, electrical data, installation guidelines, and limited warranty information.
Preview Fujitsu AIRSTAGE ASUH12LPAS Inverter Driven Heat Pump - 12,000 BTU Wall Mount Specifications
Technical specifications and features for the Fujitsu AIRSTAGE ASUH12LPAS, a 12,000 BTU inverter-driven heat pump with wall-mount type. Details include product features, lineset requirements, electrical specifications, sound pressure, fan data, and warranty information.
Preview Fujitsu L1010 Laptop: Fashionable and Functional Computing
Explore the Fujitsu L1010 laptop, featuring Intel Centrino 2 processor technology, Windows Vista Business, a 14.1-inch SuperFine WXGA display, and NVIDIA GeForce graphics. Discover its comprehensive specifications, accessories, and global support.