Mercoid Series AP Pressure Switches

Bulletin O6S - Specifications - Installation and Operating Instructions

Introduction

Series AP Diaphragm Operated Pressure Switches are reliable, convenient, compact, low-cost switches for instrument air or other low-pressure applications. Visible set point and external adjustment add convenience. Used on air, non-corrosive gas or liquid service compatible with wetted parts. These switches are available with optional weather-proof and explosion-proof housings.

Physical Description and Dimensions

The diagram illustrates the physical features and dimensions of the Mercoid Series AP pressure switch. Key features include:

  • A 7/8" (22.23 mm) conduit hole and a 7/8" (22.23 mm) knock-out hole.
  • A 1/4" NPT process connection.
  • Mounting holes are indicated.
  • Overall dimensions are provided in inches with millimeter equivalents in brackets, such as 15/16" [23.81], 1-7/16" [36.51], 2-13/32" [61.12], 2-7/8" [73.03], 4-1/8" [104.78], and 3-1/8" [79.38].
  • An adjustment screw with sealing wire is visible.

Specifications

SPECIFICATIONS
Wetted MaterialsNylon reinforced Buna-N and steel. PTFE and 316 SS optional.
Temperature Limits-30 to 150°F (-35 to 66°C).
Pressure LimitSee model chart.
Enclosure RatingGeneral purpose. Weatherproof and explosion-proof optional.
Switch TypeSPDT mercury switch or SPDT snap switch. Other switch types available.
Electrical Rating (Mercury Switch)4A @ 120 VAC/DC, 2A @ 240 VAC/DC.
Electrical Rating (Snap Switch)15A @ 120 VAC, 8A @ 240VAC, 0.5A @ 120 VDC, 0.25A @ 240 VDC.
Electrical ConnectionsScrew terminal.
Conduit Connection7/8" (22.23 mm) hole for 1/2" (12.7 mm) conduit hub.
Process Connection1/4" female NPT.
Mounting OrientationVertical for mercury switch models, any position for snap switch models.
Set Point AdjustmentExternal screw.
Weight (General purpose)2 lb (0.9 kg).
DeadbandSee model chart.
Agency ApprovalsCE, UL, CSA. For FM consult factory. (Mercury switch units are not CE approved.)

Operating Ranges - Type AP & AP-41 (Mercury Switch)

Range NumberSuffix NumberSwitch TypeLow PressureHigh Pressure
33-2SPST Opens8 in w.c. (205)10" w.c. (250)
33-3SPST Closes8 in w.c. (205)10" w.c. (250)
33-88SPST Closes3 in w.c. (80)3 in w.c. (80)
33-89SPST Opens4 in w.c. (102)4 in w.c. (102)
33-153SPST5 in w.c. (127)6 in w.c. (152)
36-2SPST Opens1.0 psig [0.07]2.0 psig [0.14]
36-3SPST Closes1.0 psig [0.07]2.0 psig [0.14]
36-26SPST Closes1.5 psig [0.10]2.5 psig [0.17]
36-36SPST Opens1.5 psig [0.10]2.5 psig [0.17]
36-88SPST Closes4 in w.c. (102)8 in w.c. (205)
36-89SPST Opens6 in w.c. (152)12" w.c. (305)
36-153SPST0.3 psig [0.02]0.5 psig [0.03]
37-2SPST Opens2.0 psig [0.14]3.0 psig [0.21]
37-3SPST Closes2.0 psig [0.14]3.0 psig [0.21]
37-26SPST Closes2.5 psig [0.17]3.5 psig [0.24]
37-36SPST Opens2.5 psig [0.17]3.5 psig [0.24]
37-88SPST Closes6 in w.c. (152)12 in w.c. (305)
37-89SPST Opens8 in w.c. (205)16 in w.c. (406)
37-153SPST0.8 psig [0.06]1.5 psig [0.11]
39-2SPST Opens6 psig [0.41]16 psig [1.10]
39-3SPST Closes8 psig [0.55]17 psig [1.17]
39-26SPST Closes8 psig [0.55]20 psig [1.38]
39-36SPST Opens8 psig [0.55]20 psig [1.38]
39-88SPST Closes1.5 psig [0.10]3.0 psig [0.21]
39-89SPST Opens1.5 psig [0.10]3.0 psig [0.21]
39-153SPST4 psig [0.28]10 psig [0.69]

Operating Ranges - Type AP (Snap Switch)

Range NumberAdjustable Pressure RangeMax. Approx. Operating Press.Single SPDTApprox. Switch Deadband(2) SPDT Snap Switches
psigLowHighLowHighLowHigh
3310" vac-50 in w.c. (250 vac-1250)15 [1.0]8 in w.c. (205)10 in w.c. (250)4.5 in w.c. (127)5 in w.c. (127)4.5 in w.c. (127)5 in w.c. (127)
361-20 psig [0.07-1.4]60 [4.1]0.5 psig [0.04]1.5 psig [0.11]0.75 psig [0.05]1.5 psig [0.11]0.75 psig [0.05]1.5 psig [0.11]
371-30 psig [0.07-2.1]60 [4.1]0.75 psig [0.05]1.5 psig [0.11]0.75 psig [0.05]1.5 psig [0.11]0.75 psig [0.05]1.5 psig [0.11]
3910-125 psig [0.7-8.6]160 [11]3 psig [0.2]7 psig [.49]1.25 psig [0.09]4 psig [0.3]1.25 psig [0.09]4 psig [0.3]

Model Chart - Series AP

ExampleConstructionReset OptionsHousing OptionsCircuit (Switching) OptionsWetted MaterialsAdjustable Pressure Ranges & Maximum Operating PressuresAgency Approvals
APAPGeneral Purpose enclosure, NEMA-1.Mercury switch type. Plated steel pressure port, Buna-N diaphragm.Adjustable range 10" wc VAC-50" wc (250 mm VAC to 1250 mm wc), maximum pressure 15 psig.UL CSA
ASASLow pressure steam switch, NEMA-1, range 34 only. Circuits, 2, 3, 26, 36, 153 only. PTFE covered diaphragm, plated steel pressure port.Adjustable range 1-15 psig (0.07 to bar), AS only, maximum pressure 30 psig (2.1 bar), maximum temperature 275°F (135°C) psig.UL CSA
FFFactory Mutual approved, NEMA-1, circuit 153 only. Range 37 only. APF-153-37 or APF-7021-153-37 only.Adjustable range 1-30 psig (0.07-2.1 bar), maximum pressure 60 psig (4.1 bar).UL FM CSA
RRManual reset - operates on decrease automatically. NEMA-1 only. Not available with circuit 88, 89 or snap switch type.UL CSA
UUManual reset - operates on increase automatically. NEMA-1 only. Not available with circuit 88, 89 or snap switch type.UL CSA
SSLess enclosureUL CSA
WTWTWeather-proof enclosure, NEMA-4.UL CSA
WWWeather-proof enclosure with condensate drain, NEMA-2, 3R.UL CSA
HHExplosion-proof enclosure, NEMA-7, 9, Class I Group, C & D; Class II Group E, F & G.UL CSA
2SPST mercury switch, Electrical Code P* - opens on pressure increase.Mercury switch type. Plated steel pressure port, Buna-N diaphragm.Adjustable range 1-20 psig (0.07-1.4 bar), maximum pressure 60 psig (4.1 bar)UL CSA
3SPST mercury switch, Electrical Code P*- closes on pressure increase.Mercury switch type. 316 stainless steel pressure port, PTFE diaphragm.Adjustable range 1-30 psig (0.07-2.1 bar), maximum pressure 60 psig (4.1 bar).UL CSA
26SPST mercury switch, Electircal Code R* - closes on pressure increase. Not available with range 33.Snap switch type. Plated steel pressure port, Buna-N diaphragm.Adjustable range 10-125 psig (0.7-8.6 bar), maximum pressure 160 psig (11 bar).UL CSA
36SPST mercury switch, Electrical Code R* - opens on pressure increase. Not available with range 33.Snap switch type. Plated steel pressure port, Buna-N diaphragm.UL CSA
88SPST magnetic mercury switch, Electrical Code T* - closes on pressure increase.Snap switch type, 316 stainless steel pressure port, PTFE diaphragm.UL CSA
89SPST magnetic mercury switch, Electrical Code T* - opens on pressure increase.Snap switch type, 316 stainless steel pressure port, PTFE diaphragm.UL CSA
153SPDT mercury switch, Electrical Code S*.UL CSA
()Other circuits available, consult factory.UL CSA
70_ - 153SPDT snap acting switch, rated 15A at 120 VAC, 8A at 240 VAC, 0.5A at 120 VDC, 0.25A at 240 VDC, 3/4 hp at 120 VAC, 1 hp at 240 VAC.UL CSA
70__ 804DPDT: 2 each SPDT snap acting switches, rated 5A at 120/240 VAC, 5A at 30 VDC resistive SPDT snap acting switch, rated 15A at 120 VAC, 8A at 240 VAC, 4A at 480 VAC, 6A at 24 VDC resistive, 0.5A at 120 VDC, 0.25A at 240 VAC, 3/4 hp at 120 VAC, 1.5 hp at 240 VAC.UL CSA
80_ - 153UL CSA
41Mercury switch type. Plated steel pressure port, Buna-N diaphragm.UL CSA
7021Mercury switch type. 316 stainless steel pressure port, PTFE diaphragm.UL CSA
8021Snap switch type. Plated steel pressure port, Buna-N diaphragm.UL CSA
7041Snap switch type. Plated steel pressure port, Buna-N diaphragm.UL CSA
8041Snap switch type, 316 stainless steel pressure port, PTFE diaphragm.UL CSA

Electrical Rating - Mercury Switch

CodeCircuit Suffix No.AC CapacityDC CapacityHorsepower
120V240V440V120V240VACDC
P-2, -310A5A3A10A5A3/41/3
R-26, -3617A AT 120/240/277 VAC, Resistive balance same as above.
S-1534A2ANA4A2A1/8NA
T-88, -890.5A0.25ANA0.25A0.125A

Operation and Application

Type AP and AP-41 with Suffix No's. -153, -2, -3, -26, 36, -88, -89 (Mercury Switch)

Operation: A variation in control pressure causes the diaphragm to actuate the hermetically sealed mercury switch to open or close the electrical contact.

Application: Type AP with suffix numbers -153, -2, -3, -26, -36, -88, -89 are for use with mediums not injurious to steel, silver solder or Fairprene diaphragm. Type AP-41 with suffix numbers -153, -2, -3, -26, -36, -88, -89 are for use with mediums not injurious to 316 SS and PTFE.

Type AP and AP-41 with Suffix No's. 153, -2, -3, -26, 36, -88, -89 (Snap Switch)

Operation: A variation in control pressure causes the diaphragm to actuate the snap action switch.

Applications: Type AP, APH, APW, APWT with suffix numbers 7021-153 or 8021-153 are for use with mediums not injurious to steel, silver solder, Nylon/Buna-N diaphragm. Type AP, APH, APW, APWT with suffix numbers 7041-153 or 8041-153 are for use with mediums not injurious to 316 SS and PTFE covered diaphragm.

Mounting

Mercury Switch Models

Install control firmly in a LEVEL POSITION on a panel or smooth wall surface by means of two mounting ears. Where pipe mounting is desired, control may be connected by means of the 1/4" I.P.S. connection. Do not mount control by twisting the case; use a wrench on the square part of the 4" bottom pipe connection. To level, sight across the two cover screws or check the lower end of the glass opening in the cover to see that instrument is lined up horizontally.

Snap Switch Models

Mount in any position. Type AP (general purpose) can be installed on a panel or smooth surface using the two mounting ears or the 4" NPT bottom connection. Do not mount by twisting the case; use a wrench on the square part of the 4" bottom pipe connection. Type APW-NEMA 3 (weather-resistant): 4" male NPT bottom connection. Type APWT-NEMA 4 (water-tight): 4" male NPT bottom connection. Type APH (explosion-proof): 4" male NPT bottom connection. Or use mounting bracket No. PP-135-95

Wiring

Wire in accordance with local electrical codes or equipment manufacturers' instructions. See nameplate attached to inside of control case for terminal markings and electrical rating. Do not overload. Do not oil any parts. Do not tamper with switch wires. Position of these wires is essential for proper operation. Tampering with these wires will void warranty.

For snap switch models, wire in accordance with the national Electrical code and local regulations. Observe wiring diagram inside enclosure and details below for type No. and electrical rating. Where control is connected directly into the load circuit, it must be wired into hot side of line. Do not overload. Do not oil any parts.

Wiring Diagram

All Types Single-Pole, Double-Throw (-153) or Double-Pole, Double Throw (-804) Operation

  • -153 - SP-DT: Common, On Hi, On Lo
  • -804 - DP-DT: Common, On Hi, On Lo (for each pole)

Adjustments

Turn adjustment screw "A" until pointer on dial indicates desired operations pressure.

Electrical Rating - Snap Switch Models

SERIESSWITCH TYPERATING
7021-153 & 7041-153SPDT15A max. 120V AC; 8A MAX. 240V AC
8021-153 & 8041-153SPDT15A max. 120V AC; 8A 240V AC; 0.5A max. 120V DC; 0.25A 240V DC 4A 480V AC 3/4 Hp. 120V AC. 1 Hp. 240V AC
7021-804 & 7041-804(2 SPDT)5A 120/240 AC -- 30V DC resistive

Contact Information

For more information or to find quality products online, please visit:

Mercoid Division

Dwyer Instruments, Inc.

Phone: 219/879-8000 | Fax: 219/872-9057

Email: info@dwyermail.com | sales@GlobalTestSupply.com

Copyright © 2014 Dwyer Instruments, Inc. Printed in U.S.A. 2/14

PDF preview unavailable. Download the PDF instead.

ap-7021-153-37-manual

Related Documents

Preview Mercoid Series 3100 Explosion-Proof Differential Pressure Transmitter: Specifications, Installation, and Operating Instructions
A comprehensive guide detailing the specifications, installation, operation, and maintenance of the Mercoid Series 3100 Explosion-Proof Differential Pressure Transmitter, including safety precautions and troubleshooting.