User Guide for MOES models including: BRT-100 Radiator Thermostat, BRT-100, BRT-100 Thermostat, Radiator Thermostat, Thermostat, Radiator

BRT-100 MOES英文说明书 210419

Notice BRT-100 EN

MOES - Tête thermostatique intelligente Zigbee 3.0 - Blanc

Notice BTR-100

MOES - Zigbee 3.0 intelligent thermostatic head - White

MOES - Zigbee 3.0 intelligent thermostatic head - Black


File Info : application/pdf, 2 Pages, 1.01MB

PDF preview unavailable. Download the PDF instead.

BRT-100 User manual
Enjoy Our Smart Life
BRT-100 Radiator Thermostat(TRV)
User Guide

Zigbee Type

Welcome
Thank you for your purchase. MOES always made high-quality products with our high-end technology, high-quality craftsmanship, safe and reliable materials .The new radiator thermostat will bring you a more comfortable smart life . Please read this installation/ programming manual for installing and operating. Please also make sure someone qualified to install the radiator . Comply with all local regulations.

FEATURES

1. LED display, no window, wider perspective 2. Colorful display 3. Graceful arc waist shape 4. Rubber stretch paint, feel like baby skin 5. Night Halo colors your home 6. Low power consumption,battery can last 1 year for normal use and standby for 2 years. 7. Low battery tip 8. Diagram of temperature curve added in APP 9. Vary colors are available like white, Black, gray etc.

In the box you will find

Raditor Thermostat User Guide RA Adapter RAV Adapter RAVL Adapter Comap Adapter T+A Herz Adapter Herz Adapter

1pc 1pc 1pc 1pc 1pc 1pc 1set 1pc

Special note: The Zigbee version of the temperature control valve should be used with a Zigbee gateway compatible with "Tuya iot'". The package does not include the battery and gateway.

APPLICATION

DIMENSION

Unit: mm

52.0 48.5

71.5 85.0

M30*1.5 53.0
HOME SCREEN QUICK REFERENCE
Week

Valve open Error warning
Battery reminder Zigbee
Room temp.
Energy saving mode Set temp.
temp.display Manual mode

Low temp. protection Holiday mode Minute Hour Key lock
Open window
Programming mode

Down

Up

menu

TECHNICAL DATA
Power Supply: 3 V,2xAA Batteries, Packaging not have battery.
Maximum stroke: 4.5mm Accuracy: ± 0.5°C Set Temp. Range: 5~45 °C Display temp. Range: 0~70°C Ambient Temp.: 0 ~ 45 °C Ambient Humidity: 5 ~ 95 % RH (Non Condensing) Storage Temp.: -5~ 45 °C Timing Error: < 1% Protection Class: IP 20 Buttons: Capacitive Touch Buttons

Before installing
To avoid damages to the product during installation, please read the manual carefully before installing TRV.

INSTALLATION
Step 1: Select the adapter.TRV is usually
connected with M30*1.5mm valve. If you have different valves, please determine your valve type according to the picture below, and choose the correct adapter from the package. If you do not find the valve that matches your use in the picture below, please buy it carefully.

Step 2: Install the adapter.Install the adapter on
your valve as the picture below. If you don't need an adapter, please ignore this step.

RA

RAV

Comap

RAVL

T+A Herz

Step 3: Install the thermostat mounting plate.
Remove the mounting plate of the thermostat (Part 1 in the picture below) counterclockwise.

Part 1
Follow the instructions in the figure below to install the mounting plate on the valve. Pay attention to the red label in the picture.
Step 4: Install battery
Follow the picture below to install the battery in the correct direction. After the battery is installed correctly, the thermostat will be turned on. At this time, click the (only once),the thermostat will display and flash "F1",

Fig. 1

when the "F1" stops flashing, the thermostat motor It will all shrink to facilitate the connection of the thermostat and the mounting plate.
Step 5: Connect the thermostat and the mounting
board When "F1" stops flashing, find the "mark point" of the thermostat, shown Fig. 1.Turn clockwise to complete the connection between the thermostat and the mounting plate. After clicking the
(only once), the thermostat will display "F2". When "F2 "disappears, while the screen remains on, turn the thermostat clockwise to adjust the screen to your liking direction.
Installation finished.
OPERATION
1. Power: After installing the battery, it will automatically turn on. It can't be turned off till the battery is removed. When the TRV is turned on, it will enter the self-check program, and all icons will be displayed firstly. Press , the screen flashes "F1", indicating that the temperature control valve is shrinking; when "F1" stops flashing, press again, The screen displays "F2",Indicates that the temperature control valve is measuring.; when the screen displays the room temperature, it indicates that the temperature control valve has completed the stroke measurement, and you can start using the temperature control valve normally.
2. Mode selection Press to switch between manual, programming, vacation modes. Manual mode - In this mode, the device executes manual temperature setting. When the set temperature is lower than the"minimum temperature", the valve is closed (forced closed); Programming mode -In this mode, the device executes a preset week programming temperature time and temperature; Holiday mode - In this mode, for example, the vacation mode is set for 10 days and the temperature is set to 15 degrees Celsius. After 10 days, the device will automatically switch to programming mode; Temporary manual mode - In this mode, icon will flash.At this time, the device executes the manually set temperature and returns to the weekly programming mode in the next time period.
3. Set the temperature Press "+"/"-" key to adjust the temperature.
4. Set the clock Press and hold for 3 seconds, the screen will display "h" and numbers, indicating that the hour is being set, set the hour by press "+" / "-" keys; press again, the screen will display "m", indicating that the minute is being set, press "+" /"-" keys to set the minutes; press again, the screen will display "number", indicating that the day of the week is being set, and

the day of the week can be set by "+" /"-"; press again, the screen will flash "number, h, m", indicating that the number of days in the vacation mode is set,
which can be set by the "+" and "-" keys;

5. Lock your Radiator Press the +" and"-" keys together for 3 seconds to lock or unlock the keys.

6. Low voltage reminder When the voltage is lower than 1.8V, the screen will display .

7. Boost heating
Press and hold "+" for 3 seconds, the device will
enter the boost heating mode, and the will flash.The countdown will be displayed in the APP.

8. Adjusting/Setting the Programmable Schedules
Method one; Manually set a week of programming settings, specific operations are as follows:
Method Two; Use APP for one week of programming settings, please refer to the second page "Programming your Radiator"
Manual editing: Press and hold for 3 seconds. When you see the flashing numbers on the screen, press 4 times to skip the clock setting. When the screen displays "" (means Monday to Friday), flashing numbers and "h", you can set the hour with "+" and "-"; press again, flashing numbers and "m", you can use " +" "-" Set the minutes; press again, the screen displays "Set", and the temperature can be set by "+" "-". This completes the setting of the programmed temperature for one week in the morning from Monday to Friday. By analogy, refer to the one-week programming temperature default table to complete one-week programming settings.

9. Programming setting

MON.-FRI. Time ( shows on scteen)

display

TIME

TEMP.

SAT. ( shows on scteen)

TIME

TEMP.

Period 1 6:00~11:30

20

6:00~12:00

24

Period 2 Period 3 Period 4

11:30~13:30 13:30~17:30 17:30~6:00

21

12:00~14:30

23

22

14:30~17:30

22

23

17:30~6:00

21

SUN. ( shows on scteen)

TIME
6:00~12:30 12:30~14:30 14:30~18:30 18:30~6:00

TEMP.
19 20 21 20

10. Setting the Functions and Options
Press and hold the "-" and 3 seconds together , entering into the advanced option settings. The screen displays "A1" (function), after 2 seconds, the number (settings and options) will display, and the options can be set by the "+"/"-" key.

Code Function

A1

Temperature compensation

Open window detection

(After the valve is opened,

the room temperature is

A2

5- N°C, every 5 minutes, check whether the room

temperature is lower than

the previous detection by

3°C)

Setting and options -9 ~ 9
00close 01open

Default -2
00

Step 2 Connect the temperature control valve
Check the tutorial below to complete the connection and setup.

When A2 is set to "01", the

device detects whether the

A3 room temperature has

N5-25

5

dropped by N°C compared

with the previous time

A4

When A2 is set to "01", close the valve time

5-60min

15

A5 Min.temp.

5-15

5

A6 Max.temp.

15-35

35

A7 Forced heating countdown

100-900s

300 (screen display 30)

A8 Detection valve head opening Open: ON Closed: OF Can only show

A9 Dead zone tempe.

0.5-5

1

AA Energy saving mode

00close 01open

00

AB

Energy saving mode temperature

5-35

20

AC Low temp. protection

0-10

5

AD Standby screen brightness

0-9

00

AE Factory reset AF version number

00: do not reset 01: reset

00

U1

11. Command priority
Priority judgment: In manual mode, Set to force close> Start low-temperature protection to force opening > Test window-opening to force closing > Boost heating

12. CE standard EMC, LVD,RF,ROHS
Common Abnormity and Processing Method

Scan QR code.

Error reminder

Failure description

Solution

icon+screen display E1

The temperature sensor is disconnected orshort-circuited

Contact seller for replacement

"Exclamation mark" icon The thermostat cannot detect the Reinstall the

+ screen flashing E2 stroke

battery to release

icon

Battery voltage is lower than 1.8V

Replacement battery

About Zigbee Step 1 Downlosd your APP (Fig. 2)

Fig. 2

IOS / Android

Search for "Smartlife" in the Apple Store or Google Play or scan the QR code above and follow the instructions of the APP to complete the installation.

Note: Tuya zigbee wireless gateway is used by default. If you use a wired gateway, please check your gateway connection tutorial.

flash

Fig.4

After-sales service in warranty period
Your thermostat is guaranteed for 24 months since the date of purchase. Service beyond the warranty period would need extra charges. For more details, please contact us directly.

Thank you for your support and purchase at we Moes,we are always here for your complete satisfaction,just feel free to share your great shopping experience with us.

If you have any other need,please do not hesitate to contact us first,we will try to meet your demand.

APP interface description

Battery power

Long press "-" for 3s, as shown in the figure below (Fig. 3), the "Zigbee" icon will flash on the screen (Fig. 4).

Room temp.

Settings Set temp.

Manual Auto

Countdown to Boost heating.
TempHand Holidays

Fig.3

Temp. curve

One week programming Advanced option settings

Temperature graph.
According to the temperature graph, you can understand the temperature change in the past time.

@moessmart @moes_smart @moes_smart

moes @moes_smart moes.net

WENZHOU NOVA NEW ENERGY CO.,LTD Address: Power Science and Technology Innovation Center, NO.238, Wei 11 Road, Yueqing Economic Development Zone, Yueqing, Zhejiang, China Tel:+86-577-57186815 Email:service@moeshouse.com
AMZLAB GmbH Laubenhof 23, 45326 Essen Made In China

210419



References

Adobe Illustrator CC 23.0 (Windows) 3-Heights™ PDF Optimization Shell 6.3.1.5 (http://www -tools.com)