Instruction Manual for neptronic models including: CMMB106 Remote I and O Communication Module, CMMB106, Remote I and O Communication Module, I and O Communication Module, Communication Module, Module
Controls ation
File Info : application/pdf, 20 Pages, 735.81KB
DocumentDocumentRemote I/O Communication Module Specification and Installation Instructions Models CMMB106 Description The CMMB extends your BACnet or Modbus network when your application requires additional inputs and outputs on a physical controller. Combining the 20 inputs and outputs of the CMMB with your Building Automation System provides simple expansion of a new or existing controller and reduces unnecessary costs of additional components. Features Power & Communication · 24Vac or 30Vdc supply · BACnet® MS/TP or Modbus communication port (selectable) Inputs & Outputs · 8 universal inputs · 2 digital inputs · 2 universal outputs (supervised) · 2 analog outputs (supervised) · 6 digital outputs (supervised) Installation · 10 override switches to manually control each output · LED status indication of each input and output · DIN rail mounting · Removable, non-strip, raising clamp terminals CMMB106 Network Communication · BACnet® MS/TP or Modbus communication port (selectable via DIP switch) · Select MAC address via DIP switch or via network BACnet® · MS/TP @ 9600, 19200, 38400 or 76800 bps · Automatic baud rate detection · Automatic device instance configuration · Copy & broadcast configuration to other CMMB modules Modbus · Modbus @ 9600, 19200, 38400 or 57600 bps · RTU Slave, 8 bits (configurable parity and stop bits) · Connects to any Modbus master Technical Specifications Specifications Input Voltage Consumption Universal Inputs Digital Inputs Universal Outputs Analog Outputs Digital Relay Outputs BACnet Modbus Communication Connections Electrical Connections Operational Temperature Storage Temperature Relative Humidity Weight Dimensions CMMB106 24 Vac or 27-33 Vdc 5VA (331mA @ 24 Vac) 8 [0.00-10.00Vdc, 10K/20K/30K, on/off (dry contact), 4.00-20.00mA] / 12b hardware resolution with oversampling 2 [normally open/closed or direct/reverse] 2 [0-10Vdc, pulsed signal (20mA drive), on/off, 4-20mA] / 1mV resolution 2 [0-10Vdc] / 1mV resolution 6 [normally open/closed, independent common per relay, 5A resistive] BACnet® MS/TP @ 9600, 19200, 38400 or 76800 bps (BAS-C) Modbus RTU slave @ 9600, 19200, 38400 or 57600. Selectable parity and stop bit configuration: · No parity, 2 stop bit · Even parity, 1 stop bit · Odd parity, 1 stop bit 24 AWG twisted-shield cable (Belden 9841 or equivalent) 0.8 mm2 [18 AWG] minimum 0ºC to 50ºC [32ºF to 122ºF] -30ºC to 50ºC [-22ºF to 122ºF] 5 to 95% non condensed 0.4 kg [0.9 lb] A C A = 6.30" / 160 mm B = 5.00" / 126 mm C = 2.25" / 57 mm B ON 1234 12345678 CMMB106-BACnet-Modbus-V1.16-240305-ESA Page | 1 Remote I/O Communication Module Specification and Installation Instructions Connections and Configurations Please note that all jumper settings must also be set to the same value through BACnet. Some additional configurations are only available through BACnet (see Network Conditions on page 4). MAC Address | DS2 The 8 DIP switches represent a binary logic to calculate the MAC address. Default = all OFF BACnet all OFF = 0 Modbus all OFF = 1 End of Line | JP3 / JP4 120 Ohms None* * default setting Network Port | TB10 A+: BACnet/Modbus A+ B-: BACnet/Modbus B- Universal Inputs | TB12-15 ** Selectable ** AI1: Universal Input 1 COM: Common AI2: Universal Input 2 AI3: Universal Input 3 COM: Common AI4: Universal Input 4 AI5: Universal Input 5 COM: Common AI6: Universal Input 6 AI7: Universal Input 7 COM: Common AI8: Universal Input 8 Digital Inputs | TB16 ** Configurable ** DI1: Digital Input 1 COM: Common DI2: Digital Input 2 Voltage Input | TB17 ** 100mA max ** COM: Common 24V: 24 Vac or 27-33 Vdc Network | DS1 4 Mode OFF BACnet* ON Modbus 3 Mode Options If BACnet OFF Auto Detect* ON Manual (see DS1-1 & DS1-2) If Modbus OFF Config via Modbus Register ON No parity, 2 stop bits * default setting 1 2 3 4 56 7 8 A+ BA+ B- AI 2 AI1 COM AI2 AI3 COM AI4 AI 3 AI 6 AI5 COM AI6 AI7 COM AI8 AI 7 DI1 COM DI2 COM 24V PO WER STA TUS JP3 JP4 BACnet/Modbus DS2 ON TX RX TX RX AI 1 AI 4 AI 5 AI 8 1234 DS1 ON Baud Rate | DS1 1 2 Result OFF OFF 9,600 ON OFF 19,200 OFF ON 38,400 ON ON BACnet: 76,800 Modbus: 57,600 JP1 = AO4 AO4 COM AO3 JP2 = AO3 AO2 COM AO1 AO3-AO4 Signal | JP1-JP2 0-10 Vdc* 4-20 mA * default setting Universal Outputs | TB1 ** Selectable ** AO4: Universal Output 4 COM: Common AO3: Universal Output 3 Analog Outputs | TB2 ** 0-10 Vdc ** AO2: Analog Output 2 COM: Common AO1: Analog Output 1 NC COM NO DO6 NC COM NO DO5 NC COM NO DO4 NC COM NO DO3 NC COM NO DO2 NC COM NO DO1 Digital Outputs | TB4-9 NC: Normally Closed COM: Common NO: Normally Open AI1-AI8 Signal | JP5-JP12 I = 4-20mA T*= 10K Ohms / on-off V= 0-10Vdc * default setting AO1-AO4 Switches | SW1-SW4 Off = 0Vdc / 0mA Auto*= Automatic On = 10Vdc / 20mA * default setting DO1-DO6 Switches | SW5-SW10 Off = Deactivated (normal state) Auto*= Automatic On = Activated (opposite state) * default setting www.neptronic.com Page | 2 Remote I/O Communication Module Specification and Installation Instructions MAC Address DIP Switch (DS2) MAC address for BACnet and Modbus communication, are selectable by DIP switch DS2 using binary logic. BACnet · Highest MAC address is 254. · Default is all switches OFF = MAC address 0 · If you do not change device instance in program mode, it will be automatically modified according to the MAC address. MAC Address 0 1 2 3 4 ... 126 ... 254 DS.1 = 1 OFF ON OFF ON OFF ... OFF ... OFF DS.2 = 2 OFF OFF ON ON OFF ... ON ... ON DS.3 = 4 OFF OFF OFF OFF ON ... ON ... ON DS.4 = 8 OFF OFF OFF OFF OFF ... ON ... ON DS.5 = 16 OFF OFF OFF OFF OFF ... ON ... ON DS.6 = 32 OFF OFF OFF OFF OFF ... ON ... ON DS.7 = 64 OFF OFF OFF OFF OFF ... ON ... ON DS.8 = 128 OFF OFF OFF OFF OFF ... OFF ... ON Default Device Instance 153000 153001 153002 153003 153004 ... 153126 ... 153254 Modbus · Highest MAC address is 247. · Default is all switches OFF = MAC address 1 · MAC address is binary value +1 · There is no device instance for Modbus. MAC Address 0+1 = 1 1+1 = 2 2+1 = 3 3+1 = 4 4+1 = 5 ... 126+1 = 127 ... 246+1 = 247 DS.1 = 1 OFF ON OFF ON OFF ... OFF ... OFF DS.2 = 2 OFF OFF ON ON OFF ... ON ... ON DS.3 = 4 OFF OFF OFF OFF ON ... ON ... ON DS.4 = 8 OFF OFF OFF OFF OFF ... ON ... OFF DS.5 = 16 OFF OFF OFF OFF OFF ... ON ... ON DS.6 = 32 OFF OFF OFF OFF OFF ... ON ... ON DS.7 = 64 OFF OFF OFF OFF OFF ... ON ... ON DS.8 = 128 OFF OFF OFF OFF OFF ... OFF ... ON DS1 ON 1234 DS2 ON 12345678 LEDs POWER Power On Off = Input voltage normal = No power STATUS BACnet TX RX TX RX Status Flashing = Normal operation (watchdog) RX/TX (BACnet) Flashing = Receiving (RX) and/or transmitting (TX) data. Modbus RX/TX (Modbus) Flashing = Receiving (RX) and/or transmitting (TX) data. Input Status On = Input on Off = Input off Flashing = Input not connected (thermistor setting only) Analog = When Universal Inputs are set to analog values (Vdc, mA, or 10K); the LED intensity corresponds to the input value. For example: At 10Vdc, the LED will be fully on. At 5Vdc, the LED will be at 50% intensity. At 0 Vdc, the LED will be off. Output Status Input Status LEDs (one per input) Output Status LEDs (one per output) On = Activated Off = Deactivated Flashing = Output pulsed Analog = When Universal and Analog outputs are set to analog values (Vdc or mA); the LED intensity corresponds to the output value. For example: At 10Vdc, the LED will be fully on. At 5Vdc, the LED will be at 50% intensity. At 0 Vdc, the LED will be off. www.neptronic.com Page | 3 Remote I/O Communication Module Specification and Installation Instructions Network Conditions Please note that all jumper settings must also be set to the same value through BACnet or Modbus. The following is a list of conditions and additional BACnet or Modbus objects. Universal Inputs (AI1-AI8) · When the jumper is set to Thermistor, you can select either °C or °F or you can set the input as a digital on/off input. · If the universal input is set as a digital on/off input, you can also set the polarity to direct or reverse. For example, in Reverse an "on" signal would be recognized as an "off" signal. · When the jumper is set to 0-10 Vdc, you can also set the range to 0-5 Vdc. Digital Inputs (DI1-DI2) · You can set the polarity to direct or reverse. For example, in Reverse an "on" signal would be recognized as an "off" signal. Universal/Analog Outputs (AO1-AO4) · You can set the polarity to direct or reverse. For example, in reverse the output range would be 10-0 Vdc instead of 0-10 Vdc. The polarity applies to all settings 0-10Vdc, 4-20mA, on/off and pulsed. · You can also set the outputs to pulsed or digital on/off. · A fixed output value can only be modified via BACnet when the override switch is in the "Automatic" position. Digital Outputs (DO1-DO6) · A fixed output (open/closed) can only be modified via BACnet when the override switch is in the "Automatic" position. · The displayed text can be set to either Open/Closed, On/Off, or Alarm/Normal (BACnet only). Supervised Outputs · All outputs are fully supervised via BACnet. This provides the actual state of the output including any manual overrides done using the on-board switches. Pulse Counting Feature The pulse counting feature enables counting the number of pulses detected by the universal or digital inputs. · When an active edge is detected, the Pulse Count is incremented by 1 up to the Prescaler value. When the Prescaler value is reached, the Accumulator is incremented by 1 and the Pulse Count is reset to 0. · For digital inputs, there is a 1ms debouncing for the detection of the edge. · For universal inputs, a value that is higher than 80% of the input's saturation confirms a high level. A value that is lower than 20% of the input's saturation confirms a low level. · On both types of inputs, the maximum frequency is 100Hz and the minimum pulse length is 5ms/50%D.C. www.neptronic.com Page | 4 BACnet Objects Table ID1 Name AI.1 UniversalInput1 AI.2 UniversalInput2 AI.3 UniversalInput3 AI.4 UniversalInput4 AI.5 UniversalInput5 AI.6 UniversalInput6 AI.7 UniversalInput7 AI.8 UniversalInput8 AV.1 AV.2 AV.3 AV.4 AV.5 AV.6 AV.7 AV.8 AV.9 AV.10 AV.11 AV.12 AV.13 AV.14 AV.15 AV.16 AV.17 AV.18 AV.19 AV.20 UI1PulseCount UI2PulseCount UI3PulseCount UI4PulseCount UI5PulseCount UI6PulseCount UI7PulseCount UI8PulseCount DI1PulseCount DI2PulseCount UI1Accumulator UI2Accumulator UI3Accumulator UI4Accumulator UI5Accumulator UI6Accumulator UI7Accumulator UI8Accumulator DI1Accumulator DI2Accumulator 1 ID is equal to ObjectType.Instance www.neptronic.com Remote I/O Communication Module Specification and Installation Instructions Description Universal input 1 mode selected by MSV.1 Universal input 2 mode selected by MSV.12 Universal input 3 mode selected by MSV.15 Universal input 4 mode selected by MSV.48 Universal input 5 mode selected by MSV.57 Universal input 6 mode selected by MSV.58 Universal input 7 mode selected by MSV.59 Universal input 8 mode selected by MSV.60 Universal input 1 pulse count. Universal input 2 pulse count. Universal input 3 pulse count. Universal input 4 pulse count. Universal input 5 pulse count. Universal input 6 pulse count. Universal input 7 pulse count. Universal input 8 pulse count. Digital input 1 pulse count. Digital input 2 pulse count. Universal input 1 pulse counter rollovers. Universal input 2 pulse counter rollovers. Universal input 3 pulse counter rollovers. Universal input 4 pulse counter rollovers. Universal input 5 pulse counter rollovers. Universal input 6 pulse counter rollovers. Universal input 7 pulse counter rollovers. Universal input 8 pulse counter rollovers. Digital input 1 pulse counter rollovers. Digital input 2 pulse counter rollovers. Writable? Out of service Out of service Out of service Out of service Out of service Out of service Out of service Out of service Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 Page | 5 Remote I/O Communication Module Specification and Installation Instructions ID1 AV.52 AV.53 AV.54 AV.55 AV.72 AV.73 AV.118 AV.119 AV.120 AV.121 AV.124 AV.125 AV.226 AV.227 AV.228 AV.229 AV.230 AV.231 AV.232 AV.233 AV.468 AV.469 Name AnalogOutput1Min AnalogOutput2Min AnalogOutput1Max AnalogOutput2Max AnalogOutput1 AnalogOutput2 AnalogOutput3Min AnalogOutput4Min AnalogOutput3Max AnalogOutput4Max AnalogOutput3 AnalogOutput4 UniversalInput1Offset UniversalInput2Offset UniversalInput3Offset UniversalInput4Offset UniversalInput5Offset UniversalInput6Offset UniversalInput7Offset UniversalInput8Offset CopyCfgStartAdd CopyCfgEndAdd Description Writable? Min. voltage of analog output 1 Min. voltage of analog output 2 Max. voltage of analog output 1 Max. voltage of analog output 2 Analog output 1 value Analog output 2 value Min. voltage of analog output 3 Min. voltage of analog output 4 Max. voltage of analog output 3 Max. voltage of analog output 4 Analog output 3 value Analog output 4 value Universal input 1 offset Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Universal input 2 offset Present Value Universal input 3 offset Present Value Universal input 4 offset Present Value Universal input 5 offset Present Value Universal input 6 offset Present Value Universal input 7 offset Present Value Universal input 8 offset Present Value Copy configuration start address Present Value Copy configuration end address Present Value AV.470 CopyCfgResult2 Copy configuration result Present Value AV.500 AV.501 AV.502 AV.503 AV.504 AV.505 AV.506 AV.507 AV.508 AV.509 AV.510 U1_MinInputValue U1_MaxInputValue U1_MinValue U1_MaxValue U2_MinInputValue U2_MaxInputValue U2_MinValue U2_MaxValue U3_MinInputValue U3_MaxInputValue U3_MinValue Universal input 1 minimum input value Universal input 1 maximum input value Universal input 1 minimum scaled value Universal input 1 maximum scaled value Universal input 2 minimum input value Universal input 2 maximum input value Universal input 2 minimum scaled value Universal input 2 maximum scaled value Universal input 3 minimum input value Universal input 3 maximum input value Universal input 3 minimum scaled value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value 2 Write 526address in present value, result will be available in description. www.neptronic.com Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) 0* Volt to AV.54 | Resolution 0.1 Volt 0* Volt to AV.55 | Resolution 0.1 Volt AV.52 to 10.0* Volt | Resolution 0.1 Volt AV.53 to 10.0* Volt | Resolution 0.1 Volt 0-100% | Resolution 0.1% 0-100% | Resolution 0.1% 0* Volt to AV.120 | Resolution 0.1 Volt 0* Volt to AV.121 | Resolution 0.1 Volt AV.118 to 10.0* Volt | Resolution 0.1 Volt AV.119 to 10.0* Volt | Resolution 0.1 Volt 0-100% | Resolution 1% 0-100% | Resolution 1% -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.01 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.01 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.01 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.01 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.01 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.01 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.01 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.01 ºC/ºF/Volt/mA 0-254 Address of first CMMB to copy Available only if BV.101 is set to No AV.468 (AV.468 + 64) Address of last CMMB to copy Available only if BV.101 is set to No AV.468 AV.469 Result of copy is available on Description property and is available only if BV.101 is set to Yes. Results: Succeed, Prog_Error, Type_Error, Model_Error, FW_Error, Mem_Error, Size_Error, Comm_Error, SlaveDevice, InProgress, AllSucceed 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA -32768 to 32767, Resolution: 0.01 -32768 to 32767, Resolution: 0.01 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA -32768 to 32767, Resolution: 0.01 -32768 to 32767, Resolution: 0.01 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA -32768 to 32767, Resolution: 0.01 Page | 6 ID1 AV.511 AV.512 AV.513 AV.514 AV.515 AV.516 AV.517 AV.518 AV.519 AV.520 AV.521 AV.522 AV.523 AV.524 AV.525 AV.526 AV.527 AV.528 AV.529 AV.530 AV.531 AV.532 AV.533 AV.534 AV.535 AV.536 AV.537 AV.538 AV.539 AV.540 AV.541 AV.542 Name U3_MaxValue U4_MinInputValue U4_MaxInputValue U4_MinValue U4_MaxValue U5_MinInputValue U5_MaxInputValue U5_MinValue U5_MaxValue U6_MinInputValue U6_MaxInputValue U6_MinValue U6_MaxValue U7_MinInputValue U7_MaxInputValue U7_MinValue U7_MaxValue U8_MinInputValue U8_MaxInputValue U8_MinValue U8_MaxValue AO1FailsafePreset AO2FailsafePreset AO3FailsafePreset AO4FailsafePreset TimeoutValue UI1_PulsePrescaler UI2_PulsePrescaler UI3_PulsePrescaler UI4_PulsePrescaler UI5_PulsePrescaler UI6_PulsePrescaler www.neptronic.com Remote I/O Communication Module Specification and Installation Instructions Description Writable? Universal input 3 maximum scaled value Universal input 4 minimum input value Universal input 4 maximum input value Universal input 4 minimum scaled value Universal input 4 maximum scaled value Universal input 5 minimum input value Universal input 5 maximum input value Universal input 5 minimum scaled value Universal input 5 maximum scaled value Universal input 6 minimum input value Universal input 6 maximum input value Universal input 6 minimum scaled value Universal input 6 maximum scaled value Universal input 7 minimum input value Universal input 7 maximum input value Universal input 7 minimum scaled value Universal input 7 maximum scaled value Universal input 8 minimum input value Universal input 8 maximum input value Universal input 8 minimum scaled value Universal input 8 maximum scaled value Analog output 1 failsafe preset value Analog output 2 failsafe preset value Analog output 3 failsafe preset value Analog output 4 failsafe preset value Network Timeout value Universal input 1 pulse counter rollover threshold. Universal input 2 pulse counter rollover threshold. Universal input 3 pulse counter rollover threshold. Universal input 4 pulse counter rollover threshold. Universal input 5 pulse counter rollover threshold. Universal input 6 pulse counter rollover threshold. Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) -32768 to 32767, Resolution: 0.01 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA -32768 to 32767, Resolution: 0.01 -32768 to 32767, Resolution: 0.01 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA -32768 to 32767, Resolution: 0.01 -32768 to 32767, Resolution: 0.01 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA -32768 to 32767, Resolution: 0.01 -32768 to 32767, Resolution: 0.01 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA -32768 to 32767, Resolution: 0.01 -32768 to 32767, Resolution: 0.01 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA 0-10Volt or 4-20mA, Resolution: 0.01Volt or 0.01mA -32768 to 32767, Resolution: 0.01 -32768 to 32767, Resolution: 0.01 0 to 100%, Resolution: 0.1% 0 to 100%, Resolution: 0.1% 0 to 100%, Resolution: 0.1% 0 to 100%, Resolution: 0.1% 5 to 600 sec, Resolution: 5 sec 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 Page | 7 Remote I/O Communication Module Specification and Installation Instructions ID1 AV.543 AV.544 AV.545 AV.546 BI.1 Name UI7_PulsePrescaler UI8_PulsePrescaler DI1_PulsePrescaler DI2_PulsePrescaler DigitalInput1 BI.2 DigitalInput2 BV.22 ContactOutput1 BV.23 ContactOutput2 BV.24 ContactOutput3 BV.25 ContactOutput4 BV.26 ContactOutput5 BV.27 BV.33 BV.34 BV.66 BV.67 BV.68 BV.69 BV.93 BV.94 BV.95 BV.96 BV.97 BV.98 BV.99 BV.100 ContactOutput6 DigitalInput1Polarity DigitalInput2Polarity AnalogOutput1Direction AnalogOutput2Direction AnalogOutput3Direction AnalogOutput4Direction UI1_DI_Polarity UI2_DI_Polarity UI3_DI_Polarity UI4_DI_Polarity UI5_DI_Polarity UI6_DI_Polarity UI7_DI_Polarity UI8_DI_Polarity BV.101 CopyCfgExecute BV.102 SystemUnit www.neptronic.com Description Universal input 7 pulse counter rollover threshold. Universal input 8 pulse counter rollover threshold. Digital input 1 pulse counter rollover threshold. Digital input 2 pulse counter rollover threshold. Digital input 1 status Digital input 2 status Digital output 1 status Digital output 2 status Digital output 3 status Digital output 4 status Digital output 5 status Digital output 6 status Polarity of digital input 1 Polarity of digital input 2 Polarity of analog output 1 Polarity of analog output 2 Polarity of analog output 3 Polarity of analog output 4 Polarity of universal input 1 when used in digital input mode Polarity of universal input 2 when used in digital input mode Polarity of universal input 3 when used in digital input mode Polarity of universal input 4 when used in digital input mode Polarity of universal input 5 when used in digital input mode Polarity of universal input 6 when used in digital input mode Polarity of universal input 7 when used in digital input mode Polarity of universal input 8 when used in digital input mode Start or stop copy configuration Select the unit system to use on the device Writable? Present Value Present Value Present Value Present Value Out of service Out of service Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0= Open / Ouvert * 1= Close / Fermé Text depends of selection in MSV.76 0= Open / Ouvert * 1= Close / Fermé Text depends of selection in MSV.77 0= Open / Ouvert / Off / Arret / Normal * 1= Close / Fermé / On / Marche / Alarm Text depends of selection in MSV.66 0= Open / Ouvert / Off / Arret / Normal * 1= Close / Fermé / On / Marche / Alarm Text depends of selection in MSV.67 0= Open / Ouvert / Off / Arret / Normal * 1= Close / Fermé / On / Marche / Alarm Text depends of selection in MSV.68 0= Open / Ouvert / Off / Arret / Normal * 1= Close / Fermé / On / Marche / Alarm Text depends of selection in MSV.69 0= Open / Ouvert / Off / Arret / Normal * 1= Close / Fermé / On / Marche / Alarm Text depends of selection in MSV.70 0= Open / Ouvert / Off / Arret / Normal * 1= Close / Fermé / On / Marche / Alarm Text depends of selection in MSV.71 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= No * 1= Yes Start copy and give results, must be reset by user. 0= Celsius * 1= Fahrenheit Page | 8 Remote I/O Communication Module Specification and Installation Instructions ID1 BV.103 BV.104 MSV.1 MSV.12 MSV.15 MSV.48 MSV.54 MSV.55 MSV.57 Name Inhibit Output Override TimeoutStatus UniversalInput1Function UniversalInput2Function UniversalInput3Function UniversalInput4Function AnalogOutput1Mode AnalogOutput2Mode UniversalInput5Function Description Writable? Inhibit the override of the outputs Present Value Network timeout status Selected analog input 1 mode Present Value Selected analog input 2 mode Present Value Selected analog input 3 mode Present Value Selected analog input 4 mode Present Value Select analog output 1 mode Select analog output 2 mode Present Value Present Value Selected analog input 5 mode Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) 0= Off * 1= On 0= Inactive * 1= Active 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel 1= Analog * 2= On_Off 3= Pulsing 1= Analog * 2= On_Off 3= Pulsing 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel www.neptronic.com Page | 9 Remote I/O Communication Module Specification and Installation Instructions ID1 MSV.58 MSV.59 MSV.60 MSV.66 MSV.67 MSV.68 MSV.69 MSV.70 MSV.71 MSV.76 Name UniversalInput6unction UniversalInput7Function UniversalInput8Function ContactOutput1Text ContactOutput2Text ContactOutput3Text ContactOutput4Text ContactOutput5Text ContactOutput6Text DigitalInput1Text Description Writable? Selected analog input 6 mode Present Value Selected analog input 7 mode Present Value Selected analog input 8 mode Present Value Contact output 1 inactive & active text Present Value Contact output 2 inactive & active text Present Value Contact output 3 inactive & active text Present Value Contact output 4 inactive & active text Present Value Contact output 5 inactive & active text Present Value Contact output 6 inactive & active text Present Value Digital input 1 inactive & active text Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel 1= Open_Close * 2= Ouvert_Fermé 3= On_Off 4= Marche_Arret 5= Alarm_Normal 1= Open_Close * 2= Ouvert_Fermé 3= On_Off 4= Marche_Arret 5= Alarm_Normal 1= Open_Close * 2= Ouvert_Fermé 3= On_Off 4= Marche_Arret 5= Alarm_Normal 1= Open_Close * 2= Ouvert_Fermé 3= On_Off 4= Marche_Arret 5= Alarm_Normal 1= Open_Close * 2= Ouvert_Fermé 3= On_Off 4= Marche_Arret 5= Alarm_Normal 1= Open_Close * 2= Ouvert_Fermé 3= On_Off 4= Marche_Arret 5= Alarm_Normal 1= Open_Close * 2= Ouvert_Fermé www.neptronic.com Page | 10 ID1 Name MSV.77 DigitalInput2Text MSV.81 AnalogOutput3Mode MSV.82 AnalogOutput4Mode MSV.83 CfgBO1FailsafeMode MSV.84 CfgBO2FailsafeMode MSV.85 CfgBO3FailsafeMode MSV.86 CfgBO4FailsafeMode MSV.87 CfgBO5FailsafeMode MSV.88 CfgBO6FailsafeMode MSV.89 CfgAO1FailsafeMode MSV.90 CfgAO2FailsafeMode MSV.91 CfgAO3FailsafeMode MSV.92 CfgAO4FailsafeMode Remote I/O Communication Module Specification and Installation Instructions Description Writable? Digital input 2 inactive & active text Present Value Select analog output 3 mode Present Value Select analog output 4 mode Present Value Configuration of the binary output 1 failsafe mode Present Value Configuration of the binary output 2 failsafe mode Present Value Configuration of the binary output 3 failsafe mode Present Value Configuration of the binary output 4 failsafe mode Present Value Configuration of the binary output 5 failsafe mode Present Value Configuration of the binary output 6 failsafe mode Present Value Configuration of the analog output 1 failsafe mode Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) 1= Open_Close * 2= Ouvert_Fermé 1= Analog * 2= On_Off 3= Pulsing 4= 4_20mA 1= Analog * 2= On_Off 3= Pulsing 4= 4_20mA 1= LastState * 2= Open 3= Close 1= LastState * 2= Open 3= Close 1= LastState * 2= Open 3= Close 1= LastState * 2= Open 3= Close 1= LastState * 2= Open 3= Close 1= LastState * 2= Open 3= Close 1= LastState * 2= Preset Configuration of the analog output 2 failsafe mode Present Value 1= LastState * 2= Preset Configuration of the analog output 3 failsafe mode Present Value 1= LastState * 2= Preset Configuration of the analog output 4 failsafe mode Present Value 1= LastState * 2= Preset www.neptronic.com Page | 11 Remote I/O Communication Module Specification and Installation Instructions Modbus Registers · Register address o As per protocol base (base 0); for PLC add 1 to protocol base. o As per holding register (base 40001) · Functions : o 03 Read Holding Register o 06 Write Single Register o 16 Write Multiple Registers · Error Codes : o 02 Illegal Data Address o 03 Illegal Value o 06 Slave Device Busy · W = Writable register, [blank] = read only. · No Real number in modbus register, use scale to calculate real number. Register = Real number * Scale => Real number = Register / Scale. Scale could be 1, 10 or 100 · Attention when writing a register that contains a bit string. If bit is writable (conditional or not), the write will always be accepted. If bit is reserved or not writable, the write will be ignored and will keep its actual state. · Use READ-MODIFY-WRITE sequence. Protocol Holding Base Register Description Data Type MSB/LSB Units/Values Writable Default Value MB LB 0 40001 MSB = Neptronic Device ID LSB = MAC Address Unsigned 1 40002 Device Baud Rate Unsigned Scale 0.01 COM Port Configuration IMPORTANT: The default value is "no parity, 2 stop bits". To change the value, 2 40003 you must set DIP switch DS1-3 to OFF. Unsigned If set to ON, it will always remain at the default value. Refer to Connections and Configurations on page 2. 3 40004 Product Name (characters 8 & 7) 2 x ASCII 4 40005 Product Name (characters 6 & 5) 2 x ASCII 5 40006 Product Name (characters 4 & 3) 2 x ASCII 6 40007 Product Name (characters 2 & 1) 2 x ASCII 7 40008 Firmware Version 8 40009 Application Version Unsigned Scale 100 Unsigned Scale 100 105 (69h) [96] [192] [384] [576] [1..247] (1h- F7h) * MAC address is writable if all DIP switches of DS2 are OFF. W* 9,600 19,200 38,400 57,600 0 = no parity, 2 stop bits [0..2] 1 = even parity, 1 stop bit W 2 = odd parity, 1 stop bit char 8 char 7 Valid ASCII character: 32 (20h) 122 (7ah), Empty = 0 W char 6 char 5 Valid ASCII character: 32 (20h) 122 (7ah), Empty = 0 W char 4 char 3 Valid ASCII character: 32 (20h) 122 (7ah), Empty = 0 W char 2 char 1 Valid ASCII character: 32 (20h) 122 (7ah), Empty = 0 W 115 1.15 103 1.03 69h 1h 96 0 43h [C] 40h [M] 31h [1] 36h [6] 115 103 40h [M] 42h [B] 30h [0] 20h [ ] www.neptronic.com Page | 12 Remote I/O Communication Module Specification and Installation Instructions Protocol Holding Base Register Description Data Type MSB/LSB Units/Values 9 40010 System Status 1 Bit String [B0..B15] 0 = Normal 1 = Fault - - - - - - - - - - - - - - - - - - B0 = System operation 10 40011 System Status 2 Bit String [B0..B15] Always 0 11 40012 Analog Input 1 12 40013 Analog Input 2 13 40014 Analog Input 3 14 40015 Analog Input 4 15 40016 Analog Input 5 16 40017 Analog Input 6 17 40018 Analog Input 7 18 40019 Analog Input 8 19 40020 Digital Input 20 40021 Analog Output 1 0-10V: Type: Unsigned, Scale:100, Unit: Volt, Range: 0.00-10.00V, Resolution: 0.01 4-20mA: Type: Unsigned, Scale:100, Unit: mA, Range: 4.00-20.00 mA, Resolution: 0.01 10K Type 3A1, 10K Type 4AI, 10K Type 2, 20K Type 6AI, 30K Type 6AI: Type: Signed, Scale:100, Unit: ºC, Range: -40.00 - 100.00 ºC, Resolution: 0.01 Type: Signed, Scale:100, Unit: ºF, Range: -40.00 - 212.00 ºF, Resolution: 0.02 10K Type 3/G: Type: Signed, Scale:100, Unit: ºC, Range: -40.00 - 150.00 ºC, Resolution: 0.01 Type: Signed, Scale:100, Unit: ºF, Range: -40.00 - 302.00 ºF, Resolution: 0.02 DI: Type: Unsigned, Scale:1, No Unit, Range: 0-1, Resolution: 1 Scaled Input (Volt), Scaled Input (mA): Type: Unsigned, Scale:1 , Resolution: 1 No Unit, Range: Ux_MinValue - Ux_MaxValue, Bit String [B0..B1] B0 = DI1 B1 = DI2 21 40022 Analog Output 2 22 40023 Analog Output 3 Unsigned Scale 10 [0..1000] Unit: %, Range: 0-100.0%, Resolution: 0.1 23 40024 Analog Output 4 24 40025 Relay Output Bit String Output Overwrite Status 25 40026 Indicates that the output is overridden Bit String by the hardware switch (SW5-SW10). 26 40027 Universal Input 1 Function 27 40028 Universal Input 2 Function 28 40029 Universal Input 3 Function 29 40030 Universal Input 4 Function 30 40031 Universal Input 5 Function Unsigned [B0..B5] [B0..B9] [1..12] B0 = Relay 1 B1 = Relay 2 B2 = Relay 3 B3 = Relay 4 B4 = Relay 5 B5 = Relay 6 B0 = Relay 1 B1 = Relay 2 B2 = Relay 3 B3 = Relay 4 B4 = Relay 5 B5 = Relay 6 B6 = AO1 B7 = AO2 B8 = AO3 B9 = AO4 1= 0_10Volt 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 www.neptronic.com Writable Default Value MB LB 0000, 0001, 1111, 1110b 0000, 0000, 0000, 0000b 32767 32767 32767 32767 32767 32767 32767 32767 0000, 0000, 0000, 0000b 0 0 W 0 0 W 0000, 0000, 0000, 0000b 0000, 0000, 0000, 0000b 3 3 W 3 3 3 Page | 13 Remote I/O Communication Module Specification and Installation Instructions Protocol Holding Base Register Description 31 40032 Universal Input 6 Function 32 40033 Universal Input 7 Function 33 40034 Universal Input 8 Function 34 40035 Universal Input 1 Offset 35 40036 Universal Input 2 Offset 36 40037 Universal Input 3 Offset 37 40038 Universal Input 4 Offset 38 40039 Universal Input 5 Offset 39 40040 Universal Input 6 Offset 40 40041 Universal Input 7 Offset 41 40042 Universal Input 8 Offset 42 40043 Analog Output 1 Mode 43 40044 Analog Output 1 Minimum Voltage 44 40045 Analog Output 1 Maximum Voltage 45 40046 Analog Output 2 Mode 46 40047 Analog Output 2 Minimum Voltage 47 40048 Analog Output 2 Maximum Voltage 48 40049 Analog Output 3 Mode 49 40050 Analog Output 3 Minimum Voltage 50 40051 Analog Output 3 Maximum Voltage 51 40052 Analog Output 4 Mode 52 40053 Analog Output 4 Minimum Voltage 53 40054 Analog Output 4 Maximum Voltage www.neptronic.com Data Type MSB/LSB Signed Scale 100 [-500..500] Unsigned Signed Scale 10 Unsigned Signed Scale 10 Unsigned Signed Scale 10 Unsigned Signed Scale 10 [1..3] [0..100] [1..3] [0..100] [1..4] [0..100] [1..4] [0..100] Units/Values 9= DigitalInput 10= ScaledValue_Volt 11= ScaledValue_mA 12= 10K_NTC_Carel Range: +/- 5.00, Resolution: 0.10 1 = Analog 2 = On/Off 3 = Pulse Unit: Volt, Range: 0 V - Register 44, Resolution: 0.1 Unit: Volt, Range: Register 43 - 10.0V, Resolution: 0.1 1 = Analog 2 = On/Off 3 = Pulse Unit: Volt, Range: 0 V - Register 47, Resolution: 0.1 Unit: Volt, Range: Register 46 - 10.0V, Resolution: 0.1 1 = Analog 2 = On/Off 3 = Pulse 4 = 4-20mA Unit: Volt, Range: 0 V - Register 50, Resolution: 0.1 Unit: Volt, Range: Register 49 - 10.0V, Resolution: 0.1 1 = Analog 2 = On/Off 3 = Pulse 4 = 4-20mA Unit: Volt, Range: 0 V - Register 53, Resolution: 0.1 Unit: Volt, Range: Register 52 - 10.0V, Resolution: 0.1 Writable Default Value MB LB 3 3 3 0 0 0 0 W 0 0 0 0 W 1 0 W 100 W 1 0 W 100 W 1 0 W 100 W 1 0 W 100 Page | 14 Remote I/O Communication Module Specification and Installation Instructions Protocol Holding Base Register Description Data Type MSB/LSB System Options 54 40055 * = digital input mode only Bit String [B0..B15] 55 40056 Universal Input 1 Minimum Input Value Unsigned Scale 100 56 40057 Universal Input 1 Maximum Input Value Unsigned Scale 100 57 40058 Universal Input 1 Minimum Value Signed Scale 1 58 40059 Universal Input 1 Maximum Value Signed Scale 1 59 40060 Universal Input 2 Minimum Input Value Unsigned Scale 100 60 40061 Universal Input 2 Maximum Input Value Unsigned Scale 100 61 40062 Universal Input 2 Minimum Value Signed Scale 1 62 40063 Universal Input 2 Maximum Value Signed Scale 1 63 40064 Universal Input 3 Minimum Input Value Unsigned Scale 100 64 40065 Universal Input 3 Maximum Input Value Unsigned Scale 100 65 40066 Universal Input 3 Minimum Value Signed Scale 1 66 40067 Universal Input 3 Maximum Value Signed Scale 1 67 40068 Universal Input 4 Minimum Input Value Unsigned Scale 100 www.neptronic.com [0..100] [0..100] [-32768...32767] [-32768...32767] [0..100] [0..100] [-32768...32767] [-32768...32767] [0..100] [0..100] [-32768...32767] [-32768...32767] [0..100] Units/Values Writable Default Value MB LB 0 = Direct 1 = Reverse - - - - - - - - - - - - - - - - - - B0 = AO1 polarity B1 = AO2 polarity B2 = AO3 polarity B3 = AO4 polarity B4 = AI1 polarity * B5 = AI2 polarity * B6 = AI3 polarity * B7 = AI4 polarity * B8 = AI5 polarity * B9 = AI6 polarity * B10 = AI7 polarity * B11 = AI8 polarity * B12 = DI1 polarity B13 = DI2 polarity 0 = Off 1 = On - - - - - - - - - - - - - - - - - - - B14 = Inhibit Output Override - - - - - - - - - - - - - - - - - - - 0 = Celsius 1 = Fahrenheit - - - - - - - - - - - - - - - - - - - B15 = System Unit W Unit: Volt, Range: 0.00 V - Register 56, Resolution: 0.01 Unit: mA, Range: 4.00 mA - Register 56, Resolution: 0.01 W Unit: Volt, Range: Register 55 10.00 V, Resolution: 0.01 Unit: mA, Range: Register 55 20.00 mA, Resolution: 0.01 W 0000, 0000, 0000, 0000b 0 1000 No Unit, Range: -32768 - Register 58, Resolution: 0.01 W 0 No Unit, Range: Register 57 - 32767, Resolution: 0.01 W Unit: Volt, Range: 0.00 V - Register 60, Resolution: 0.01 Unit: mA, Range: 4.00 mA - Register 60, Resolution: 0.01 W Unit: Volt, Range: Register 59 10.00 V, Resolution: 0.01 Unit: mA, Range: Register 59 20.00 mA, Resolution: 0.01 W No Unit, Range: -32768 - Register 62, Resolution: 0.01 W 1000 0 1000 0 No Unit, Range: Register 61 - 32767, Resolution: 0.01 W Unit: Volt, Range: 0.00 V - Register 64, Resolution: 0.01 Unit: mA, Range: 4.00 mA - Register 64, Resolution: 0.01 W Unit: Volt, Range: Register 63 10.00 V, Resolution: 0.01 Unit: mA, Range: Register 63 20.00 mA, Resolution: 0.01 W No Unit, Range: -32768 - Register 66, Resolution: 0.01 W 1000 0 1000 0 No Unit, Range: Register 65 - 32767, Resolution: 0.01 W Unit: Volt, Range: 0.00 V - Register 68, Resolution: 0.01 Unit: mA, Range: 4.00 mA - Register 68, Resolution: 0.01 W 1000 0 Page | 15 Remote I/O Communication Module Specification and Installation Instructions Protocol Holding Base Register Description Data Type MSB/LSB 68 40069 Universal Input 4 Maximum Input Value Unsigned Scale 100 69 40070 Universal Input 4 Minimum Value Signed Scale 1 70 40071 Universal Input 4 Maximum Value Signed Scale 1 71 40072 Universal Input 5 Minimum Input Value Unsigned Scale 100 72 40073 Universal Input 5 Maximum Input Value Unsigned Scale 100 73 40074 Universal Input 5 Minimum Value Signed Scale 1 74 40075 Universal Input 5 Maximum Value Signed Scale 1 75 40076 Universal Input 6 Minimum Input Value Unsigned Scale 100 76 40077 Universal Input 6 Maximum Input Value Unsigned Scale 100 77 40078 Universal Input 6 Minimum Value Signed Scale 1 78 40079 Universal Input 6 Maximum Value Signed Scale 1 79 40080 Universal Input 7 Minimum Input Value Unsigned Scale 100 80 40081 Universal Input 7 Maximum Input Value Unsigned Scale 100 81 40082 Universal Input 7 Minimum Value Signed Scale 1 82 40083 Universal Input 7 Maximum Value Signed Scale 1 83 40084 Universal Input 8 Minimum Input Value Unsigned Scale 100 84 40085 Universal Input 8 Maximum Input Value Unsigned Scale 100 85 40086 Universal Input 8 Minimum Value Signed Scale 1 86 40087 Universal Input 8 Maximum Value Signed Scale 1 87 40088 Binary Output 1 Fail Safe Mode Unsigned [0..100] [-32768...32767] [-32768...32767] [0..100] [0..100] [-32768...32767] [-32768...32767] [0..100] [0..100] [-32768...32767] [-32768...32767] [0..100] [0..100] [-32768...32767] [-32768...32767] [0..100] [0..100] [-32768...32767] [-32768...32767] [1..3] www.neptronic.com Units/Values Unit: Volt, Range: Register 67 10.00 V, Resolution: 0.01 Unit: mA, Range: Register 67 20.00 mA, Resolution: 0.01 No Unit, Range: -32768 - Register 70, Resolution: 0.01 No Unit, Range: Register 69 - 32767, Resolution: 0.01 Unit: Volt, Range: 0.00 V - Register 72, Resolution: 0.01 Unit: mA, Range: 4.00 mA - Register 72, Resolution: 0.01 Unit: Volt, Range: Register 71 10.00 V, Resolution: 0.01 Unit: mA, Range: Register 71 20.00 mA, Resolution: 0.01 No Unit, Range: -32768 - Register 66, Resolution: 0.01 No Unit, Range: Register 65 - 32767, Resolution: 0.01 Unit: Volt, Range: 0.00 V - Register 64, Resolution: 0.01 Unit: mA, Range : 4.00 mA - Register 64, Resolution: 0.01 Unit: Volt, Range: Register 63 10.00 V, Resolution: 0.01 Unit: mA, Range: Register 63 20.00 mA, Resolution: 0.01 No Unit, Range: -32768 - Register 78, Resolution: 0.01 No Unit, Range: Register 77 - 32767, Resolution: 0.01 Unit: Volt, Range: 0.00 V - Register 80, Resolution: 0.01 Unit: mA, Range: 4.00 mA - Register 80, Resolution: 0.01 Unit: Volt, Range: Register 79 10.00 V, Resolution: 0.01 Unit: mA, Range: Register 79 20.00 mA, Resolution: 0.01 No Unit, Range: -32768 - Register 82, Resolution: 0.01 No Unit, Range: Register 81 - 32767, Resolution: 0.01 Unit: Volt, Range: 0.00 V - Register 84, Resolution: 0.01 Unit: mA, Range: 4.00 mA - Register 84, Resolution: 0.01 Unit: Volt, Range: Register 83 10.00 V, Resolution: 0.01 Unit: mA, Range: Register 83 20.00 mA, Resolution: 0.01 No Unit, Range: -32768 - Register 86, Resolution: 0.01 No Unit, Range: Register 85 - 32767, Resolution: 0.01 1= LastState 2= Open 3= Close Writable Default Value MB LB W 1000 W 0 W 1000 W 0 W 1000 W 0 W 1000 W 0 W 1000 W 0 W 1000 W 0 W 1000 W 0 W 1000 W 0 W 1000 W 0 W 1000 W 1 Page | 16 Remote I/O Communication Module Specification and Installation Instructions Protocol Holding Base Register Description Data Type MSB/LSB 88 40089 Binary Output 2 Fail Safe Mode Unsigned [1..3] 89 40090 Binary Output 3 Fail Safe Mode Unsigned [1..3] 90 40091 Binary Output 4 Fail Safe Mode Unsigned [1..3] 91 40092 Binary Output 5 Fail Safe Mode Unsigned [1..3] 92 40093 Binary Output 6 Fail Safe Mode Unsigned [1..3] 93 40094 Analog Output 1 Fail Safe Mode Unsigned [1,2] 94 40095 Analog Output 1 Fail Safe Preset Value Unsigned Scale 10 [0..1000] 95 40096 Analog Output 2 Fail Safe Mode Unsigned [1,2] 96 40097 Analog Output 2 Fail Safe Preset Value Unsigned Scale 10 [0..1000] 97 40098 Analog Output 3 Fail Safe Mode Unsigned [1,2] 98 40099 Analog Output 3 Fail Safe Preset Value Unsigned Scale 10 [0..1000] 99 40100 Analog Output 4 Fail Safe Mode Unsigned [1,2] 100 40101 Analog Output 4 Fail Safe Preset Value Unsigned Scale 10 [0..1000] 101 40102 Timeout Status Unsigned [0,1] 102 40103 Network Timeout Value 103 40104 UI1 Pulse Prescaler (0) 104 40105 UI1 Pulse Prescaler (1) 105 40106 UI2 Pulse Prescaler (0) 106 40107 UI2 Pulse Prescaler (1) 107 40108 UI3 Pulse Prescaler (0) 108 40109 UI3 Pulse Prescaler (1) 109 40110 UI4 Pulse Prescaler (0) Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 [5..600] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] www.neptronic.com Units/Values 1= LastState 2= Open 3= Close 1= LastState 2= Open 3= Close 1= LastState 2= Open 3= Close 1= LastState 2= Open 3= Close 1= LastState 2= Open 3= Close 1= LastState 2= Preset Unit: %, Range: 0 100.00 %, Resolution: 0.1 1= LastState 2= Preset Unit: %, Range: 0 100.00 %, Resolution: 0.1 1= LastState 2= Preset Unit: %, Range: 0 100.00 %, Resolution: 0.1 1= LastState 2= Preset Unit: %, Range: 0 100.00 %, Resolution: 0.1 0= Inactive 1= Active Unit: Seconds (sec), Range: 5 600 sec, Resolution: 5 sec Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Writable Default Value MB LB W 1 W 1 W 1 W 1 W 1 W 1 W 100 W 1 W 100 W 1 W 100 W 1 W 100 0 W 30 W 0 W 0 W 0 W 0 Page | 17 Protocol Holding Base Register Description 110 40111 UI4 Pulse Prescaler (1) 111 40112 UI5 Pulse Prescaler (0) 112 40113 UI5 Pulse Prescaler (1) 113 40114 UI6 Pulse Prescaler (0) 114 40115 UI6 Pulse Prescaler (1) 115 40116 UI7 Pulse Prescaler (0) 116 40117 UI7 Pulse Prescaler (1) 117 40118 UI8 Pulse Prescaler (0) 118 40119 UI8 Pulse Prescaler (1) 119 40120 DI1Pulse Prescaler (0) 120 40121 DI1 Pulse Prescaler (1) 121 40122 DI2 Pulse Prescaler (0) 122 40123 DI2 Pulse Prescaler (1) 123 40124 UI1 Pulse Count (0) 124 40125 UI1 Pulse Count (1) 125 40126 UI2 Pulse Count (0) 126 40127 UI2 Pulse Count (1) 127 40128 UI3 Pulse Count (0) 128 40129 UI3 Pulse Count (1) 129 40130 UI4 Pulse Count (0) 130 40131 UI4 Pulse Count (1) 131 40132 UI5 Pulse Count (0) 132 40133 UI5 Pulse Count (1) 133 40134 UI6 Pulse Count (0) 134 40135 UI6 Pulse Count (1) 135 40136 UI7 Pulse Count (0) 136 40137 UI7 Pulse Count (1) 137 40138 UI8 Pulse Count (0) 138 40139 UI8 Pulse Count (1) www.neptronic.com Remote I/O Communication Module Specification and Installation Instructions Data Type MSB/LSB Units/Values Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Writable Default Value MB LB W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 Page | 18 Protocol Holding Base Register Description 139 40140 DI1 Pulse Count (0) 140 40141 DI1 Pulse Count (1) 141 40142 DI2 Pulse Count (0) 142 40143 DI1 Pulse Count (1) 143 40144 UI1 Accumulator (0) 144 40145 UI1 Accumulator (1) 145 40146 UI2 Accumulator (0) 146 40147 UI2 Accumulator (1) 147 40148 UI3 Accumulator (0) 148 40149 UI3 Accumulator (1) 149 40150 UI4 Accumulator (0) 150 40151 UI4 Accumulator (1) 151 40152 UI5 Accumulator (0) 152 40153 UI5 Accumulator (1) 153 40154 UI6 Accumulator (0) 154 40155 UI6 Accumulator (1) 155 40156 UI7 Accumulator (0) 156 40157 UI7 Accumulator (1) 157 40158 UI8 Accumulator (0) 158 40159 UI8 Accumulator (1) 159 40160 DI1 Accumulator (0) 160 40161 DI1 Accumulator (1) 161 40162 DI2 Accumulator (0) 162 40163 DI2 Accumulator (1) Remote I/O Communication Module Specification and Installation Instructions Data Type MSB/LSB Units/Values Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Writable Default Value MB LB W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 www.neptronic.com Page | 19 Recycling at end of life: please return this product to your Neptronic local distributor for recycling. If you need to find the nearest Neptronic authorized distributor, please consult www.neptronic.com. 400 Lebeau blvd, Montreal, Qc, H4N 1R6, Canada www.neptronic.com Toll free in North America: 1-800-361-2308 Tel.: (514) 333-1433 Fax: (514) 333-3163 Customer service fax: (514) 333-1091 Monday to Friday: 8:00am to 5:00pm (Eastern time)