CVGAUDIO NEXT T-LITE Series

Quick Start User Manual

PROFESSIONAL PUBLIC ADDRESS D-CLASS INTEGRATION MIXER-AMPLIFIER

General Information

The CVGAUDIO NEXT T-lite is a series of compact professional public address mixer-amplifiers designed for commercial background sound and announcement systems. The series includes four models with power ratings of 40W/100V, 80W/100V, 120W/100V, and 240W/100V. Low-impedance connection is not provided in these models. All models in the series operate in Class D.

The amplifiers feature two selective line inputs (AUX1 / AUX2), the ability to connect an external remote universal signal source (e.g., MP3/FLAC player, Bluetooth, FM tuner) with a volume control, and one universal microphone input with phantom power capability and priority activation over line inputs. With active priority, the signal attenuation level can be controlled from full muting to mixing. A separate two-band graphic equalizer is provided for line and microphone inputs.

The amplifier has a compact metal housing with an aluminum front panel. Volume controls for microphone and line inputs, when pressed, sit flush with the front panel.

The standard CVGAUDIO NEXT T-lite package includes two brackets for easy wall mounting, securing on a horizontal surface, under a tabletop, or on the ceiling. The amplifier housing height is standard 1U. Brackets for rack mounting are optional (mounting holes are provided on the chassis).

For integration with emergency fire alarm systems, EXT.MUTE contacts are available. The contact is 'normally open'; when closed, the broadcast is interrupted.

Amplifier Installation Rules

  1. Ventilation openings for cooling the output stage heatsink must be unobstructed. Nothing should impede free air circulation.
  2. When choosing an installation location, avoid areas with poor ventilation, restricted air circulation, or high ambient temperatures.
  3. Do not connect the amplifier to the mains power supply if the power cord is damaged or worn.
  4. Use grounded electrical outlets.
  5. Observe polarity when connecting loudspeaker systems and ensure the amplifier's rated power matches the connected load (maximum total loudspeaker system power for T-lite 40 = 40W/100V; T-lite 80 = 80W/100V; T-lite 120 = 120W/100V; T-lite 240 = 240W/100V).
  6. Connecting low-impedance (4ohm/8ohm/16ohm) speakers to NEXT T-lite series amplifiers is prohibited. The amplifiers are compatible only with 100V line transformer speakers.

Warranty Obligations

Subject to compliance with all the above installation and operation rules, all CVGAUDIO NEXT T-lite series amplifier models are provided with a free warranty service period of 1 year from the date of purchase by the end customer. Information about service centers can be found on the company's website.

ATTENTION: To prevent electrical shock, do not remove covers. No user-serviceable parts inside. Refer all servicing to qualified personnel only.

Front Panel of Amplifier

Controls and Indicators:

Rear Panel of Amplifier

Connectors and Controls:

Safety Warning: НЕ ВСКРЫВАТЬ КОРПУС ПРИ ВКЛЮЧЕННОМ ЭЛЕКТРОПИТАНИИ (~220V, 50Hz) - Do not open the case while the power is on.

Amplifier Connection

Connections for External Devices:

Connecting Remote Panels:

External remote volume control panels and panels with a universal signal source can be used with NEXT series amplifiers. The maximum recommended distance is 50 meters. CAT5E/CAT6 'twisted pair' cable is recommended for simultaneous transmission of power, audio signal, and volume control.

Only one volume control (NVC) or one universal panel (NVC-SRC) can be connected at a time. Two panels with signal sources cannot be used simultaneously.

Possible connection options:

  1. NVC volume control only.
  2. NVC-SRC universal panel with volume control and signal source only.
  3. N-SRC signal source panel only.
  4. NVC volume control plus N-SRC signal source panel.

To enable remote volume control, activate DIP-switch #3 (ON - upper position) on the rear panel. The external signal source on a remote panel is effectively connected to AUX1 input. It is recommended not to connect other signal sources to AUX1 when using remote panels with signal sources.

The amplifier has two selective unbalanced line inputs (AUX1/AUX2). Only one can be active at a time, selected via buttons on the front panel. AUX1 is activated by default upon power-up.

The microphone input can accommodate dynamic or condenser/electret microphones. Phantom power and priority activation are configurable via DIP-switch (14). If priority is active, line inputs are muted when a signal is present on the microphone input. The attenuation level is adjusted by the PRIORITY MUTE control (12).

Dual-band equalizers are provided separately for line and microphone inputs for frequency correction.

The PREAMP OUT linear output is used for connecting additional zonal amplifiers, active subwoofers, recording devices, etc. The signal level at this output is affected by all preamplifier controls (MUSIC/SPEAK volume, input gain controls, EQ settings).

The EXT.MUTE contact pair is essential for public spaces, integrating the local music system with the global fire alarm system. When activated by a fire alarm module, it mutes the background music to ensure emergency announcements are clear.

Connecting Loudspeaker Systems to the Amplifier

NEXT-T series amplifiers are designed exclusively for 100V line transformer loudspeaker systems. All connected loudspeakers must be wired in parallel. Multiple branches are permissible, but within each branch and between branches, loudspeakers must be connected in parallel.

The total power of all connected loudspeaker systems must not exceed the amplifier's rated power:

Exceeding the power threshold will result in amplifier failure.

Connect the loudspeaker cables to the amplifier's 100V/COM output. Ensure correct polarity: the COM terminals of the loudspeakers must connect to the amplifier's COM output, and the selected power tap terminals on the loudspeakers must connect to the amplifier's 100V output.

Convenient screw terminals are provided at the output, accommodating cables up to 2.5mm² in cross-section.

Technical Specifications

ParameterNEXT T-lite 40NEXT T-lite 80NEXT T-lite 120NEXT T-lite 240
NameProfessional compact mixer-amplifier
Amplifier ClassD-CLASS
Power40W/100V80W/100V120W/100V240W/100V
SPEAKERS OUTScrew terminal, max cable section 2x2.5mm², 100V speakers only
LINE IN2 selective stereo RCA line inputs, input for external remote signal source
MIC INBalanced XLR(m), phantom power, ON/OFF MIC priority
PREAMP OUTPUT2RCA
TONE CONTROLS (2 EQ separate for MIC / LINE)BASS +/- 10dB @ 100Hz, TREBLE +/- 10dB @ 10kHz
FREQUENCY RESPONSE80 - 18500Hz
MIC INPUT SENSITIVITY6mV
LINE INPUT SENSITIVITY250mV
S/N RATEDLine in-72dB / MIC in-68dB
THD<0.5% @ 1kHz, 1/3 rated output power
DIMENSIONS (HxWxD)260mm x 217mm x 44mm
RACK UNITS1U (brackets for installation - optional)
WEIGHT[Weight not specified in source]
POWER SUPPLYAC~200-240V/50-60Hz
POWER CONSUMPTION[Power consumption not specified in source]
PROTECTIONOverheating protection, intelligent active cooling for 120W and 240W models, short-circuit protection, overload protection.

Technical specifications are subject to change by the manufacturer without prior notice.

Product Passport

FieldDetails
BRANDCVGAUDIO (RUSSIA)
MODEL[To be filled in upon sale]
SERIAL NUMBER[To be filled in upon sale]
DATE OF MANUFACTURE[To be filled in upon sale]
DATE OF SALE[To be filled in by the selling company for the end consumer]
MANUFACTURER'S STAMP/SIGNATURE (CVGAUDIO)[Signature of authorized representative of the Manufacturer]
DISTRIBUTOR'S STAMP/SIGNATURE[Signature of authorized representative of the Seller]
WARRANTY PERIOD1 year from the date of sale to the end user / commissioning of the object.
PURCHASER'S SIGNATURE
FULL NAME / COMPANY[Purchaser's Full Name / Company]
DATE OF PURCHASE
Models: NEXT T-LITE Professional Public Address D class Integration Mixer Amplifier, NEXT T-LITE, Professional Public Address D class Integration Mixer Amplifier, Address D class Integration Mixer Amplifier, D class Integration Mixer Amplifier, Integration Mixer Amplifier, Mixer Amplifier

File Info : application/pdf, 8 Pages, 5.21MB

PDF preview unavailable. Download the PDF instead.

CVGAudio NEXT T-LITE 40

References

CorelDRAW 2019 3-Heights™ PDF Toolbox API 6.12.0.6 (http://www -tools.com)