User Guide for Icron models including: 00-00437, 00-00438, 00-00439, 00-00440, 00-00441, USB 3-2-1 Raven 3124 USB Multimode Fiber Point to Point Extender System, USB 3-2-1 Raven 3124, USB Multimode Fiber Point to Point Extender System, Multimode Fiber Point to Point Extender System, Fiber Point to Point Extender System, Point to Point Extender System, Extender System, System
On the LEX and REX units, check that the Power, Status, Link, USB 2 and USB 3 LEDs are on. ... date of purchase. Icron's hardware warranty extends to Licensee, ...
File Info : application/pdf, 19 Pages, 402.31KB
DocumentDocumentIcron USB 3-2-1 RavenTM 3124 4-Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 RavenTM 3124. Please read this guide thoroughly. This document applies to the following part numbers: Model North American System European System United Kingdom System Australia System Japan System Icron USB 3-2-1 Raven 3124 00-00437 00-00438 00-00439 00-00440 00-00441 FCC Radio Frequency Interference Statement Warning This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. CE Statement We, Icron Technologies Corporation, an Analog Devices brand, declare under our sole responsibility that the USB 3-2-1 RavenTM 3124, to which this declaration relates, is in conformity with European Standards EN 55032, EN 55035, EN 61000, EN 62368-1 and RoHS Directive 2011/65/EU + 2015/863/EU. IC Statement This Class B digital apparatus complies with Canadian ICES-003. CAN ICES-3 (B)/NMB-3 (B) WEEE Statement The European Union has established regulations for the collection and recycling of all waste electrical and electronic equipment (WEEE). Implementation of WEEE regulations may vary slightly by individual EU member states. Please check with your local and state government guidelines for safe disposal and recycling or contact your national WEEE recycling agency for more information. Product Operation and Storage Please read and follow all instructions provided with this product, and operate for intended use only. Do not attempt to open the product casing as this may cause damage and will void warranty. Use only the power supply provided with this product (if applicable). When not in use, product should be stored in a dry location between -20°C and 70°C. ©2023 All rights reserved. Document #90-01579-A02 Contents Introduction .............................................................................................................3 Product Contents ................................................................................................................................ 3 Features .................................................................................................................................................. 3 The LEX Unit .......................................................................................................................................... 4 The REX Unit.......................................................................................................................................... 5 Installation Guide ....................................................................................................6 Installing the USB 3-2-1 Raven 3124 System............................................................................. 6 Fiber Optic Cabling............................................................................................................................. 6 Requirements ....................................................................................................................................... 6 Preparing Your Site ............................................................................................................................. 6 Installing the LEX Unit ...................................................................................................................... 7 Connecting the LEX to the REX ..................................................................................................... 7 Installing the REX Unit....................................................................................................................... 7 Checking the Installation ................................................................................................................. 7 Connecting a USB Device................................................................................................................. 8 Compatibility ........................................................................................................................................ 8 Optional Ethernet Pass Through Connection ........................................................................... 8 Optional USB Extender Mounting Options ...........................................................9 Troubleshooting ....................................................................................................11 Warranty Information ...........................................................................................14 Obtaining Warranty Service .................................................................................14 Specifications.........................................................................................................15 Contacting Technical Support ..............................................................................16 Technical Glossary .................................................................................................17 Introduction This guide provides product information for the USB 3-2-1 RavenTM 3124, installation instructions and troubleshooting guidelines. The instructions in this guide assume a general knowledge of computer installation procedures, familiarity with cabling requirements and some understanding of USB devices. note NOTE: Notes provide additional information that could be useful. CAUTION: Cautions provide important information about an operational requirement. Product Contents Your Raven 3124 extender system contains: · LEX (Local Extender) · REX (Remote Extender) · USB 3.1 Gen 1 Cable · LEX 24V DC 1A International Power Adapter · REX 24V DC 2.71A International Power Adapter · 2 x Country Speci c Power Cables · Quick Start Guide Features The Raven 3124 incorporates ExtremeUSB-CTM technology, enabling users to extend USB 3.1 beyond the standard 3m cable limit for USB 3.1 peripheral devices. This extender system is composed of two individual units, the LEX and the REX, and has the following key features: · Up to 200m of extension when directly connected over OM3 multimode ber · Support for new USB 3.1 Gen 1/2 host controllers and devices (up to 5 Gbps) · Support for all device USB types · Backwards compatible to USB 2.0 devices The Raven 3124 includes the ExtremeUSB-CTM suite of features: · Transparent USB extension supporting USB 3, 2 and 1 · True plug and play; no software drivers required · Works with all major operating systems: Windows®, macOSTM, Linux® and Chrome OSTM note The Raven 3124 only works with OM3 multimode ber or higher grade. 3 The LEX Unit The LEX unit connects to the computer using a standard USB 3.1 Gen 1 cable. Power for this unit is provided by the included 24V 1A adapter. Front View Power 1 Mode Config 2 3 Rear View Status Link USB 2 USB 3 4567 Link LAN USB 24V 1A 8 ITEM TYPE 1 Power LED 9 DESCRIPTION 10 11 LED is SOLID ON when DC is supplied to the extender unit. LED is OFF when no power is supplied by the AC Adapter 2 Mode Reserved for manufacturer use. 3 Config Reserved for manufacturer use. 4 Status LED LED is SOLID ON when system is functioning normally. LED BLINKS when system is booting OR to indicate a temperature warning in unison with the LINK, USB 2, and USB 3 LEDs. 5 Link LED LED is SOLID ON when LEX is linked to an opposite REX. LED is OFF when there is no connection between the LEX and REX units. 6 USB 2 LED LED is SOLID ON when an active USB 2 connection is established through the extender system. LED BLINKS when the USB 2 connection is suspended/asleep. LED is OFF when no USB 2 connection is detected. 7 USB 3 LED LED is SOLID ON when an active USB 3 connection is established through the extender system. LED BLINKS when the USB 3 connection is suspended/asleep. LED is OFF when no USB 3 connection is detected. 8 LAN Port (100 Mbps) Ethernet pass through channel connects to a network or Ethernet device. 9 Link Port Extension link Duplex LC ber optic transceiver port. 10 USB Host Port USB 3 Type B receptacle used to connect LEX to USB 3 Host computer. 11 DC Power Port Locking connector for the included power adapter accepts 24VDC 1A. 4 The REX Unit The REX unit provides USB 3.1 Type A ports for standard USB devices and allows you to connect up to four USB devices directly. Additional devices may be connected by attaching up to three USB hubs to the REX. The REX is powered by an external AC 24V 2.71A adapter, supplying up to 1.2 Amp per USB port. Front View Power 1 Mode Config 2 3 Rear View Status Link USB 2 USB 3 4567 Link LAN 10 10 USB USB 10 10 USB USB 24V 2.71A 8 ITEM TYPE 1 Power LED 9 11 DESCRIPTION LED is SOLID ON when DC is supplied to the extender unit. LED is OFF when no power is supplied by the AC Adapter. 2 Mode Reserved for manufacturer use. 3 Config Reserved for manufacturer use. 4 Status LED LED is SOLID ON when system is functioning normally. LED BLINKS when system is booting OR to indicate a temperature warning in unison with the LINK, USB 2, and USB 3 LEDs. 5 Link LED LED is SOLID ON when LEX is linked to an opposite REX. LED is OFF when there is no connection between the LEX and REX units. 6 USB 2 LED LED is SOLID ON when an active USB 2 connection is established through the extender system. LED BLINKS when the USB 2 connection is suspended/asleep. LED is OFF when no USB 2 connection is detected. 7 USB 3 LED LED is SOLID ON when an active USB 3 connection is established through the extender system. LED BLINKS when the USB 3 connection is suspended/asleep. LED is OFF when no USB 3 connection is detected. 8 LAN Port (100 Mbps) Ethernet pass through channel connects to a network or Ethernet device. 9 Link Port Extension link Duplex LC ber optic transceiver port. 10 Device Ports (Type A) Accepts all USB devices. 11 DC Power Port Locking connector for the included power adapter accepts 24VDC 2.71A. 5 Installation Guide Installing the USB 3-2-1 Raven 3124 System Requirements To complete the installation, you will also require the following items that are not included with this system: · USB compatible computer (host computer) with a USB compliant operating system · USB compatible device(s) · OM3 Fiber optic cabling Fiber Optic Link Cabling The LEX and REX extenders are interconnected by fiber optic cabling. Duplex multimode ber cabling is required for the Raven 3124 for extending up to 200m using 50/125m OM3 grade cable. The cabling subsystem must provide a duplex connection with crossover, and must be terminated with Duplex LC connectors at both ends. Host USB Cable OM3 Fiber Optic Link Cable USB Devices USB 3-2-1 up to 200m over MMF LEX LAN REX IP Control Optional Network Connections Preparing Your Site Before installing the Raven 3124 extender, you will need to prepare your site: 1. Place the computer where desired and set it up. 2. Ensure to locate the USB device(s) within the cable-length of the computer. If not, adjust the location of the device(s) and/or computer accordingly. 3. If you are using surface cabling, the Raven 3124 supports a maximum distance of 200m over OM3 multimode ber. 4. If using premise cabling, ensure compatible ber optic cabling is installed between the two locations and does not to exceed the speci ed distance. 6 Installing the LEX Unit 1. Place the LEX unit near the computer. 2. Assemble the power adapter and country speci c power cord together and connect them into a suitable AC outlet. 3. Connect the supplied USB 3.1 Gen cable between the LEX host port and a USB 3 port on the host computer. Connecting the LEX to the REX With Surface Cabling: 1. Plug one end of the ber optic cabling (not included) into the Link port on the LEX. 2. Plug the other end of the ber optic cabling into the Link port on the REX. With Premise Cabling: 1. Plug one end of a ber optic patch cord (not included) into the Link port on the LEX. 2. Plug the other end of the patch cord into the ber optic information outlet near the host computer. 3. Plug one end of the second ber optic patch cord (not included) into the Link port on the REX. 4. Plug the other end of the second patch cord into the ber optic information outlet near the USB device. Installing the REX Unit 1. Place the REX near the USB device(s). 2. Connect the power adapter to the REX. Checking the Installation 1. On the LEX and REX units, check that the Power, Status, Link, USB 2 and USB 3 LEDs are on. If the Link LEDs are permanently o , then the cabling between the LEX and REX units may not be installed properly or is defective. 2. For Windows users (XP, 7, 8, 8.1, 10), open Device Manager to con rm that the extender system has been installed correctly. Expand the entry for Universal Serial Bus controllers by clicking the "+" sign. If the extender system has been installed correctly, you should find two separate instances of "Generic SuperSpeed USB Hub" listed. note To open Device Manager in Windows XP: Right click "My Computer" then select: Properties >> Hardware tab >> Device Manager note To open Device Manager in Windows 7: Open the Start Menu, right click on "Computer" then select: Manage >> Device Manager note To open Device Manager in Windows 8, 8.1 or 10: Right click the Start Menu and then select: Device Manager 7 3. For macOS users, open the System Profiler to con rm that the extender system has installed correctly. In the left-hand column under Hardware, select "USB" and inspect the right hand panel. If the extender has been installed correctly, you should find it listed as two separate instances of "Hub" under the USB SuperSpeed Bus. note To open System Profiler in macOS: Open the Finder, select Applications, then open the Utilities folder and double click on the System Pro ler icon. 4. If the extender system is not detected correctly or fails to detect, please consult the Troubleshooting section in this guide. Connecting a USB Device 1. Install any software required to operate the USB device. Refer to the documentation for the USB device, as required. 2. Connect the USB device to the device port on the REX. 3. Check that the device is detected and installed properly in the operating system. Compatibility The USB 3-2-1 Raven 3124 complies with USB 2.0 and USB 3.1 Gen 1 speci cations governing the design of USB devices. However, there is no guarantee that all USB devices or hosts will be compatible as there are a number of di erent characteristics that may impact the operation of USB devices over extended distances. Optional Ethernet Pass Through Connection The Raven 3124 o ers a 100 Mbps Ethernet pass through connection that can be used for a variety of purposes including: · Connecting network devices · Providing remote network access to the same location as the REX unit · Leveraging existing cabling to provide USB 3-2-1 connectivity without losing network connectivity Up to 200m LAN over OM3 MMF Network Device Up to 100m LEX CAT 5e/6/7 REX Up to 100m CAT 5e/6/7 Connect any network device or access port into the RJ45 socket label "LAN" using up to 100 meters of standard CAT 5e, 6 or 7 cabling. 8 Optional USB Extender Mounting Options The bottom of the enclosure features four convenient pre-drilled holes for optional mounting. Based on your requirements, choose from two available mounting options: 1. USB Extender Mounting Kit (Purchased separately Order Part #10-00620 USB Mounting Kit - Silver) 2. USB Extender Direct Surface Mounting (Using your own hardware, stencil provided on page 10) OPTION 1: USB Extender Mounting Kit - each kit includes: · 2 mounting brackets · 4 (M3) locking washers · 4 (M3 x 10mm) Phillips screws · Mounting bracket installation guide (see diagram below) 1 kit required to mount per LEX or REX Using a Phillips screwdriver, in the order as illustrated below, fasten and secure the provided screws, locking washers and brackets into place. Once the bracket mounting is secured onto the extender, it is ready for mounting onto a surface. Please note you will need to provide your own screws to secure the extender using the available slots on each bracket. 9 OPTION 2: USB Extender Direct Surface Mounting (using your own hardware) The bottom of the enclosure features four pre-drilled holes for optional surface mounting. Distance between the enclosure mounting holes: 42.0mm x 205.5mm mounting hole 1. Mark the center point of each of the four holes on your mounting surface either by directly measuring or printing a stencil from www.icron.com/pdf/R-M-stencil.pdf. 2. Hardware recommendation: M3 locking washers and M3 screws (4 of each per extender) noting screw length will depend upon thickness of mounting surface. 3. Drill through each of the four-hole markings on the mounting surface using a 3.97mm (5/32") drill bit. 4. Align the bottom enclosure holes to the newly drilled out holes on the mounting surface. 5. Place a locking washer on each of the four screws and using a screwdriver, fasten the extender into place. note Do not exceed a screw depth of 10mm (0.4") into the unit or damage may occur. Direct Surface Mounting Measurement Stencil The stencil illustration pictured below is only 50% of the original size. To access this stencil le (to scale), simply go to: www.icron.com/pdf/R-M-stencil.pdf. 4.0mm (5/32") in 4 places 205.5mm (8.1") 42.0mm (1.6") 10 Troubleshooting The following table provides troubleshooting tips. The topics are arranged in the order in which they should be executed in most situations. If you are unable to resolve the problem after following these instructions, please contact Icron Technologies' Technical Support for further assistance. PROBLEM ALL LEDs are OFF on the LEX and/or REX. CAUSE 1. The LEX and/or REX is not receiving power from the AC power adapter. POWER LED is 1. The unit has malfunctioned ON, STATUS LED and requires re-programming. is OFF. Link LEDs on the 1. There is no connection LEX and REX are between the LEX and REX OFF. units. SOLUTION 1. Ensure that the AC power adapter is properly connected to the LEX and/or REX. 2. Check that the AC adapter is connected to a live source of AC power. Check that the LEX and/or REX Power LED is illuminated. 1. Contact Technical Support for assistance. 1. Ensure that a crossover OM3 multimode ber optic cable of no more than 200m is connected between the LEX and REX. LINK LEDs on 1. The host computer is not the LEX and REX powered on. are SOLID ON, 2. The LEX is not connected to a but the USB 2 computer. and USB 3 LEDs 3. The host computer does not are OFF. support USB Hubs. 4. The unit is malfunctioning. The USB 2 LED 1. The LEX is not connected to a is SOLID ON, but USB 3 port. the USB 3 LED is OFF. 2. The LEX is connected to the host using a USB 2 cable. 2. Connect a short ber optic patch cable between the LEX and REX. Recheck the link status. If the LINK LED is now SOLID ON, the previous cable is defective or not capable of supporting the link. 1. Disconnect all USB devices from the REX. 2. Disconnect LEX from the host computer. 3. Disconnect AC adapters from LEX and REX. 4. Reconnect the LEX to the host computer. 5. Reconnect the AC adapters to the LEX and REX. 6. Check that the LEX and REX have enumerated as USB hubs in Windows Device Manager, macOS System Pro ler or using "Isusb" command in a Linux Terminal. 7. If the problem is not resolved, contact Technical Support. 1. Ensure that the LEX is connected to a USB 3 port on the host computer. 2. Ensure that the included USB 3.1 Gen 1 cable is being used between the host computer and LEX. 3. The USB 3 cable connecting the LEX to the host computer is defective. 3. Cold boot the host computer. 4. Replace the USB 3.1 Gen 1 cable with a di erent cable. 4. The host computer's USB 3 5. If the problem is not resolved, contact Technical controller has malfunctioned. Support. 11 PROBLEM The USB 3 LED is SOLID ON, but the USB 2 LED is OFF. CAUSE 1. The USB cable connecting the LEX to the host computer is defective. SOLUTION 1. Ensure that the included USB 3.1 Gen 1 cable is being used between the host computer and LEX. 2. The host computer's USB 2.0 controller has malfunctioned. 3. The host computer does not support USB 2. 2. Cold boot the host computer. 3. Replace the USB 3.1 Gen 1 cable with a di erent cable. 4. If the problem is not resolved, contact Technical Support. Both the LEX and REX extenders are working, but the USB 2 or USB 3 LEDs on the LEX and REX are blinking. 1. The LEX and/or REX is in 1. Recover/resume the operating system from suspend mode. For a variety of sleep or hibernate modes (refer to your reasons, the host computer operating system's documentation). may place the LEX/REX into suspend mode. Typically, it 2. Connect a USB device to the REX. is because there are no USB devices attached, the USB 3. Use the connected device. device is asleep, or the host computer is in a sleep state or 4. If the problem persists, contact Technical hibernating. Support. ALL LEDs on 1. The USB device is both the LEX and malfunctioning. REX units are SOLID ON, but 2. The computer does not the USB device recognize the USB device. is not operating correctly, or is 3. The application software for detected as an the USB device is not "Unknown Device" operating. in the operating system. 4. The USB extender is malfunctioning. 1. Disconnect the extender from the computer. 2. Connect the USB device directly to the host computer. 3. If the device does not operate as expected, consult the user documentation for the device. 4. Update the host computer BIOS, chipset or USB controller drivers from the manufacturer's website. 5. If the device operates as expected when directly connected to the computer, connect another device to the extender and reconnect it to the host computer. 6. If the second device does not operate, the extender may be malfunctioning. Contact Technical Support for assistance. 7. If the second device operates as expected, then the rst device may not be compatible with this extender. Contact Technical Support. 12 PROBLEM A USB 3 device is not enumerating as USB 3, or the operating system is notifying the user that the device can "Perform Faster if connected to a USB 3 port". CAUSE 1. The USB device is malfunctioning. 2. The computer does not recognize the USB device. 3. The application software for the USB device is not operating. 4. The USB 3 port on the computer is malfunctioning. 5. The USB extender is malfunctioning. SOLUTION 1. Disconnect the extender from the computer. 2. Connect the USB 3 device directly to the host computer. 3. If the device does not operate as expected as a USB 3 device, consult the user documentation for that device or try a di erent USB port on the host computer. 4. Update the host computer BIOS, chipset or USB controller drivers from the manufacturer's website. 5. If the device operates as USB 3 device when directly connected to the computer, connect another USB 3 device to the extender and reconnect it to the host computer. 6. If the second device does not operate as a USB 3 device, the extender may be malfunctioning. Contact Technical Support for assistance. 7. If the second device operates as a USB 3 device as expected, the rst device may not be compatible with this extender. Contact Technical Support. All LEDs are ashing and the system is operational. 1. Unit is or was operating at an 1. Check ambient temperature. Ensure unsafe temperature. temperature does not exceed 50°C (122°F). 2. Power cycle the unit to remove LED status. All LEDs are ashing and the system is NOT operational. 1. Unit has exceeded safe operating temperature. 1. Remove external sources of heat or change location of the unit. 2. Power cycle the unit to return to operation. LEDs are scrolling LEFT to RIGHT, starting with STATUS. 1. Unit is programming. 1. Wait for the unit to nish programming. 13 Warranty Information Limited Hardware Warranty Icron warrants that any hardware products accompanying this documentation shall be free from signi cant defects in material and workmanship for a period of two years from the date of purchase. Icron's hardware warranty extends to Licensee, its customers and end users. The Warranty does not include repair of failures caused by: misuse, neglect, accident, modi cation, operation outside a normal operating environment, failure caused by service of the device by nonauthorized servicers, or failure caused by a product for which Icron is not responsible. Opening the enclosures will void warranty. Hardware Remedies Icron's entire liability and the Licensee's exclusive remedy for any breach of warranty shall be, at Icron's option, either (a) return of the price paid or (b) repair or replacement of hardware; which will be warranted for the remainder of the original warranty period or 30 days, whichever is longer. These remedies are void if failure of the hardware has resulted from accident, abuse, or misapplication. Limitation of Liability The hardware warranty set forth in this agreement replaces all other warranties. Icron expressly disclaims all other merchantability and tness for a particular purpose and noninfringement of third-party rights with respect to the hardware. Icron dealer, agent, or employee is not authorized to make any modi cation extension or addition to this warranty. Under no circumstances will Icron, its suppliers or licensors be liable for any costs of procurement or substitute products or services, lost pro ts, loss of information or data, or any other special, indirect, consequential, or incidental damages arising in any way out of the sale of, use of, or inability to use Icron product or service, even if Icron, its suppliers or licensors have been advised of the possibility of such damages. In no case shall Icron, its suppliers and licensors' liability exceed the actual money paid for the products at issue. Since some jurisdictions do not allow the limitation of implied warranties of liability for incidental, consequential, special or indirect damages, the above limitation may not always apply. The above limitation will not apply in case of personal injury where and to the extent that applicable law requires such liability. Obtaining Warranty Service To obtain warranty service, you must rst contact Icron within the warranty period for a Return Material Authorization (RMA) number. Icron will not accept returns without an authorized RMA number. Be sure to include the serial numbers of the LEX unit and REX unit in any of your online correspondence. Package the product appropriately for safe shipment and mark the RMA number on the outside of the package. The package must be sent prepaid to Icron Technologies Corporation. We recommend that you insure it or send it by a method that provides for tracking of the package. The repaired or replaced item will be shipped to you, at Icron's expense, not later than thirty days after Icron receives the defective product. 14 Specifications RANGE Point-to-Point USB DEVICE SUPPORT Maximum Throughput Tra c Types Device Types Maximum Number of Devices and/or Hubs LOCAL EXTENDER (LEX) USB Connector Link Connector Network Pass Through: Dimensions Enclosure Material Power Supply REMOTE EXTENDER (REX) USB Connector Link Connector Network Pass Through: Dimensions Enclosure Material Available Current Power Supply ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity COMPLIANCE Certi cations SUPPORT Warranty Up to 200m (656 ft) over OM3 or better multimode ber 5 Gbps All Tra c Types All Device Types Up to 30 devices 1 x USB 3.1 Gen 1 Type B Receptacle 1 x Duplex LC 1 x RJ45 137.3mm x 232.1mm x 33.0mm (5.4" x 9.1" x 1.3") Silver Anodized Aluminum 100-240V AC Input, 24V 1A DC Output 4 x USB 3.1 Gen 1 Type A Receptacles 1 x Duplex LC 1 x RJ45 137.3mm x 232.1mm x 33.0mm (5.4" x 9.1" x 1.3") Silver Anodized Aluminum Up to 1.2 Amp (6W) to each USB port 100-240V AC Input, 24V 2.71A DC Output 0°C 50°C (32°F 122°F) -20°C 70°C (-4°F 158°F) 20% to 80% relative humidity, non-condensing 10% to 90% relative humidity, non-condensing FCC (Class B), CE (Class B), RoHS2/3 (CE), ICES-003 Issue 7, EN 62368-1 2-year 15 Contacting Technical Support If you are experiencing problems not referenced in the Troubleshooting section, contact Icron Technical Support: www.icron.com/support Tel: +1 604 638 3939 To help us serve you better, please include the following information with your technical support request: · Host computer make and model · Type of Operating System installed (e.g. Windows 10, macOS 10.12, etc.) · Part number and serial number for both the LEX and REX units · Make and model of any USB device(s) attached to this extender system · Description of the installation such as Host computer model, transmission media used and information about the USB device(s) · Description of the problem Address the returned product to: Icron Technologies Corporation Att: RMA Coordinator 4664 Lougheed Highway, Suite 221 Burnaby, BC V5C 5T5 Canada Contacting Sales Email: www.icron.com/contact Tel: +1 604 638 3920 16 Technical Glossary USB 3 and USB 2.0 Cables USB cables have two distinct full-sized connectors. The Type A connector is used to connect the cable from a USB device to the Type A port on a computer or hub. The Type B connector is used to attach the USB cable to a USB device. USB Type A port Duplex LC USB Type A connector USB 3 Type A connector USB Type B port USB Type B connector USB 3Type B port USB 3 Type B connector When a crossover ber-optic cable is called for, the cable has the transmit signal on one end connected to the receive signal at the other end. 17 Icron Technologies Corporation 4664 Lougheed Highway, Suite 221 Burnaby, BC Canada V5C 5T5 Tel: +1 604 638 3920 Fax: +1 604 638 3930 www.icron.com 18