PTAC WALL SLEEVE INSTALLATION INSTRUCTIONS The wall sleeve must be installed before the air conditioner or heat pump chassis can be set in place. Read the instructions thoroughly before proceeding. When 230/208 volt units are to be installed, the power supply may be either cord connected or permanent wiring. Permanent wiring may be done through the hard wire junction box, or the accessory subbase. When 265 volt units are to be installed, the power supply must be permanent wiring. Permanent wiring may be done through the accessory hard wire junction box, or the accessory subbase. An exposed cord connection on 265 volt units is not permitted. The subbase accessory includes leveling legs. If added wall sleeve support is required and the subbase is not to be used an accessory leveling leg kit may be installed. Made in USA Contents KIT ACCESSORIES ..................................................................................................... 2 DRAIN KIT ....................................................................................................... 2 SUBBASE, LEVELING LEGS, MAIN DUCT, AND HYDRONIC HEAT KITS ........................ 2 PRE-INSTALLATION CONSIDERATIONS .................................................................. 3 OUTDOOR ENCLOSURE PANEL REMOVAL .............................................................. 3 WALL SLEEVE INSTALLATION .................................................................................. 4 RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION ATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation. Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use. Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good safety practices...follow them. The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence. Part No. A3495105 Printed in USA August 2005 KIT ACCESSORIES DRAIN KIT An indoor/outdoor drain kit is available as an accessory item. When a drain kit is to be installed, do so before installing the wall sleeve in the wall. See the drain kit for actual installation instructions. SUBBASE, LEVELING LEGS, MAIN DUCT, AND HYDRONIC HEAT KITS Installation of these kits requires drilling of mounting holes on both sides of the wall sleeve. The minimum required clearance distance between the wall sleeve and wall is shown in Table 1. If the distance between wall sleeve and wall will be at or near the minimum clearance distance, mount these kits on the sleeve before installing the sleeve in the wall. The kit installation instructions are included with the accessory kits. 16 1/16" 410 mm M1in0i7m452um1m/m4" 16 1/4" 415 mm Minimum Finished Floor Dimension "B" in Table 1 Figure 2 - Minimum Wall Opening Dimensions Outside Wall 42" 1065 mm Internal Adjacent Wall Top of Wall Sleeve "A" Minimum "A" Minimum Allow Front Clearance (See Table 1) Internal Adjacent Wall Wall Receptacle Within 58" From Bottom Right Side Corner on 208/230 VAC Units Only 14 1/8" 359 mm Figure 1 - Wall Sleeve Dimensions Figure 3 - Minimum Unit Clearances Outside Wall Cabinet Side 1/4" 6 mm Minimum Room Side "C" in Table 1 Carpet or Finished Floor "B" in Table 1 Figure 4 - Minimum Interior and Exterior MINIMUM CLEARANCES AND PROJECTIONS OPTION MINIMUM CLEARANCES A (Figure 2) B (Figure 3) Inches mm Inches mm MINIMUM PROJECTION C (Figure 4) Inches mm Wall Sleeve Only 3 75 0 0 0 0 Subbase Kit 3 75 3 1/4 85 2 3/4 70 Leveling Legs Kit 3 75 3 75 2 50 Duct Kit 3 75 0 0 2 3/8 35 Hydronic Heat Kit "A Series" 9 230 0 to 3 1/43 0 to 853 32 752 Hydronic Heat Kit "J Series" 6 150 0 0 2 1/2 65 Drain Kit 3 75 '01 '01 0 0 Hardwire Kit 3 75 1 1/4 30 0 0 1 If inside mounted then B = 1 1/2 inches (40 mm) 2 To achieve a flush fit between the hydronic front and the finished wall, Dimension "C" must be between 3" and 3 1/8". If this dimension is more than 3 1/8" there will be a gap between the front and the wall. This gap could permit occupant access to hydronic lines or other dangerous parts. 3 This dimension can be from 0" to 3-1/4", but cannot exceed 3-1/4". If this dimension exceeds 3-1/4", the skirt around the front will not reach the floor. Table 1 2 PRE-INSTALLATION CONSIDERATIONS Before proceeding with the sleeve installation, ensure the following guidelines for locating the wall opening and sleeve are met: · The wall opening must be the correct size. See Figure 1 for wall sleeve dimensions and Figure 2 for minimum wall opening size. · The wall sleeve will need to be installed with minimum clearances to the floor and adjacent walls. Minimum projections of the sleeve into and out of the room will also have to be met. See Figures 3 and 4 as well as Table 1 for details. · If installed in a concrete or masonry wall, a lintel must be provided in the wall opening for support. Do not use the wall sleeve as a lintel. See Figure 5 for a typical lintel construction. · When installed in the opening, the wall sleeve must be horizontally level from side to side and pitched (one quarter bubble in the sight glass) to the outside. DO NOT SLOPE THE WALL SLEEVE TOWARD THE ROOM. (Figure 5) · The installer must determine and supply the mounting bolts and/or screws to attach the wall sleeve to the sides of the wall opening. Make sure the wall opening is adequate for strong support. · The installer must provide adequate sealing and insulation around the sleeve after it is installed. See Figure 6 for one of many types of constructions. · If used, a 208/230-volt wall receptacle must be located within 58 inches of the lower right sleeve corner. Extension cords must not be used with the unit. See the note on Figure 1. · For installations in walls deeper than 13-7/8 inches, special care is necessary to prevent problems with rain water, condensate drainage and intake/discharge air. Under these circumstances, careful job site analysis and precautions are required. You must consult with your Sales Representative and receive approval before attempting such installations. OUTDOOR ENCLOSURE PANEL REMOVAL The sleeve stiffener must be taken out before the enclosure panel can be removed from the sleeve. 1. Remove the zig-zag folded cardboard sleeve stiffener (Figure 7). 2. Remove the rear closure panel by folding the four flaps as indicated in Figure 8. 3. Grasping the top and bottom flanges of the rear closure panel as shown in Figure 9, the entire panel is pulled out diagonally from one side. Install the wall sleeve condenser air grille by using the screws and holes provided. (See the Installation Instructions provided for the grille kits.) Lintel Wood Frame Figure 5 - Framing with Lintel Concrete Lintel 13 1/2" (340 mm) Maximum (No Accessories) 1/4" 6 mm Minimum Projection 13 3/4" 350 mm Steel Lintel Caulk Top, Bottom, and Both Sides Finished Floor Power Supply Conduit Receptacle Figure 6 - Block and Brick Veneer Installation Sleeve Stiffener Figure 7- Sleeve Stiffener Remova Rear Closure Panel Flaps Figure 8 - Rear Enclosure Panel 3 Figure 9 - Panel Removal WALL SLEEVE INSTALLATION After the wall opening is checked and approved for location, size, and clearances, complete the following to install the wall sleeve. 1. Remove the outside enclosure panel from the wall sleeve. 2. Slide the wall sleeve into the wall opening. Do not distort the cabinet shape to fit the wall opening; the unit chassis must fit snugly and uniformly into the wall sleeve. 3. Locate the sleeve within the range of minimum projections, as shown in Figures 3 and 4, so both sides are at least the minimum projection from the wall. Mounting Holes (Drilled by Installer) Alternative Fastening Method (Field Supplied) Wood Screw Toggle Bolt Expansion Anchor Bolt Plastic Screws Anchor 4. Check the level of the wall sleeve. For proper drainage, the sleeve should be level from side to side and one-quarter bubble in the sight glass sloping to the outside. Figure 10 - Wall Sleeve Attachment to Opening 5. Two holes will need to be drilled in both sides of the wall sleeve for mounting into the wall. Drill holes of proper size and in the proper location so the screws will engage into strong supporting members of the wall. DO NOT DRILL THROUGH BOTTOM OF SLEEVE. Figure 10 shows possible fastening methods. 6. Check the level of the wall sleeve and adjust if necessary. 7. Caulk or seal around the outside of the entire sleeve. 8. If the unit chassis will not be installed immediately, replace the enclosure panel on the outside opening of the sleeve. This will prevent weather damage to the building interior. 9. Recycle or dispose of packaging materials per local codes. 4Acrobat Distiller 7.0.5 (Windows)