User Manual for DMX4ALL models including: DMX RDM Sensor, RDM Sensor, Sensor
DMX/RDM-Sensor 4
File Info : application/pdf, 19 Pages, 748.82KB
DocumentDocumentDMX/RDM-Sensor 4 User Manual DMX/RDM-Sensor 4 2 For your own safety, please read this user manual and warnings carefully before installation. Contents Description.................................................................................................................. 3 Content ....................................................................................................................... 4 Connection ................................................................................................................. 5 Operation Mode .......................................................................................................... 6 DMX ........................................................................................................................ 6 RDM........................................................................................................................ 7 RGB-LED-Display....................................................................................................... 7 Configuration .............................................................................................................. 8 RDM ........................................................................................................................... 9 Lock device settings.............................................................................................. 12 Factory Reset........................................................................................................ 13 Dimension................................................................................................................. 14 Accessory ................................................................................................................. 15 Revision History........................................................................................................ 16 CE-Conformity .......................................................................................................... 17 Disposal.................................................................................................................... 17 Warning .................................................................................................................... 17 Risk-Notes ................................................................................................................ 18 DMX/RDM-Sensor 4 3 Description The DMX/RDM-Sensor 4 is a converter with 4 signal inputs and can be used both as a DMX output device / DMX source or as an RDM device. Different Operation Modes The DMX/RDM-Sensor 4 can be run as DMX output device (inputs to DMX channels) or RDM device (inputs to sensor values). Four Analog- or Digital Inputs Each of the 4 inputs can be set independently as analog input (0-5V or 0-10V) or as digital input (Active Low, Active High or Toggle). RDM Support The DMX/DMX-sensor 4 can be configured via RDM using DMX. Sensor Values Via the RDM-Parameter SENSOR_VALUE for each of the 4 inputs the sensor values can be requested. Settable Average-Filter The average filter can be set for each input and can be used to create an average value that compensates for fluctuations in the input signal. Settable Slope Correction The output curve can be set for each input using the adjustable slope correction. Settable DMX-Addresses The DMX addresses can be set for each input, allowing the input signal to be output on up to 8 DMX channels. Settable Device Label The device label can be set for each input to name each sensor uniquely via RDM. Lockable Device settings The RDM parameters Lock Pin and Lock State allow or avoid changing saved RDM parameters to prevent unauthorized changes. Free RDM-Software For setting the parameters via RDM, our free RDM Configurator software is available for download on our website www.dmx4all.de. Top hat rail housing available The top-hat rail housing 350 or the top-hat rail housing 350 flat are available as accessories for the DMX/RDM-Sensor 4. DMX/RDM-Sensor 4 4 Data Sheet Power supply: 12-24V DC (150mA@12V / 100mA@24V) Protocol: DMX512 or RDM Operation modes: DMX (Inputs to DMX channels) RDM (Inputs to RDM sensor values) Inputs: 4 Analog (0-10V) or Digital Inputs Connections: Screw terminals Dimension: 29,2mm x 82mm Content 1x DMX/RDM-Sensor 4 1x Quick guide german and english DMX/RDM-Sensor 4 5 Connection POWER 12-24V DMX / RDM 12-24V GND GND DMXDMX+ D M X-S ens or 4 IN1 IN2 IN3 IN4 GND 0-10V 0-5V DMX/RDM-Sensor 4 6 Operation Mode The DMX/RDM-Sensor 4 can be used for two different operating modes. This is selected via the jumper: Pin 1 and 2 = DMX Pin 2 and 3 = RDM DMX Within the DMX operation mode, the DMX/RDM-Sensor 4 is a DMX source. The input signals are outputted according to the DMX addresses and DMX personality specified in the configuration. POWER 12-24V DMX-Gerät DMX-Gerät 12-24V GND GND DMXDMX+ D M X-S ens or 4 IN1 IN2 IN3 IN4 GND The RDM parameter DMX_CHANNELS specifies the DMX addresses on which the output should take place. Up to 8 DMX addresses must be specified, separated by commas or minus for range. DMX/RDM-Sensor 4 7 RDM Within the RDM operation mode, the DMX/RDM-Sensor 4 is a RDM device. The input signals are provided according to the configuration via RDM sensor values. POWER 12-24V DMX/RDM Gerät DMX/RDM Gateway 12-24V GND GND DMXDMX+ D M X-S ens or 4 IN1 IN2 IN3 IN4 GND RGB-LED-Display The DMX/RDM-Sensor 4 has one RGB-LED-Display, showing the current device status: Off RED lights RED flashes GREEN lights BLUE lights Power supply not connected No operation mode selected No DMX input signal selected The device works with operation mode RDM The device works with operation mode DMX DMX/RDM-Sensor 4 8 Configuration The DMX/RDM-Sensor 4 must be configured in RDM mode. - Jumper must be plugged for RDM (Pin 2 and 3) - Connect the DMX/RDM-Sensor 4 with a ArtNet-RDM Gateway - Use a RDM-Software, to set parameters The free RDM Configurator is recommended in combination with a DMX-Stage Profi RDM Gateway. DMX/RDM-Sensor 4 9 RDM RDM is the short form for Remote Device Management. As soon as the device is within the system, device-dependent settings can occur remotely via RDM command due to the uniquely assigned UID. A direct access to the device is not necessary. This device supports the following RDM commands: Parameter ID DISC_UNIQUE_BRANCH Discovery SET GET ANSI/ Command Command Command PID E1.20 DISC_MUTE E1.20 DISC_UN_MUTE E1.20 DEVICE_INFO E1.20 SUPPORTED_PARAMETERS E1.20 PARAMETER_DESCRIPTION E1.20 SOFTWARE_VERSION_LABEL E1.20 DEVICE_LABEL E1.20 MANUFACTURER_LABEL E1.20 DEVICE_MODEL_DESCRIPTION E1.20 IDENTIFY_DEVICE E1.20 FACTORY_DEFAULTS E1.20 DMX_PERSONALITY E1.20 DMX_PERSONALITY_DESCRIPTION E1.20 DISPLAY_LEVEL E1.20 SENSOR_DEFINITION E1.20 SENSOR_VALUE E1.20 LOCK_STATE E1.37 LOCK_STATE_DESCRIPTION E1.37 LOCK_PIN E1.37 Parameter ID SERIAL_NUMBER1) AVERAGE_FILTER1) SLOPE_ADJUST1) DMX_CHANNELS1) DMX/RDM-Sensor 4 10 Discovery Command SET Command GET Command ANSI/ PID PID: 0xD400 PID: 0xD470 PID: 0xD471 PID: 0xD472 1) Manufacturer depending RDM control commands (MSC - Manufacturer Specific Type) Manufacturer depending RDM control commands: SERIAL_NUMBER PID: 0xD400 Outputs a text description (ASCII-Text) of the device serial number. GET Send: PDL=0 Receive: PDL=21 (21 Byte ASCII text) AVERAGE_FILTER PID: 0xD470 This parameter sets the average filter value (Average-Filter). GET Send: PDL=0 Receive: PDL=1 (1 Byte number of filter values) SET Send: PDL=1 (1 Byte number of filter values) Receive: PDL=0 SLOPE_ADJUST PID: 0xD471 This parameter sets the slope correction. GET Send: PDL=0 Receive: PDL=2 (2 Byte value of slope correction) SET Send: PDL=2 (2 Byte value of correction) Receive: PDL=0 DMX/RDM-Sensor 4 11 DMX_CHANNELS PID: 0xD472 This parameter sets the DMX channels. GET Send: PDL=0 Receive: PDL=32 (32 Byte ASCII-String) SET Send: PDL=2 (32 Byte ASCII-String) Receive: PDL=32 DMX/RDM-Sensor 4 12 Lock device settings The RDM parameters Lock Pin and Lock State allow or prohibit changing saved RDM parameters. Lock Pin The four-digit pin code number for the lock function can be set using the Lock Pin parameter. After entering the correct currently used PIN (Old PIN) in the RDM software (e.g. RDM Configurator), the new, desired PIN can be entered in the New PIN field and saved by setting the parameter. When delivered, the lock pin is always 0000. Lock State The device settings can be locked or unlocked using the Lock State parameter. The following lock states can be selected: Value Name Description 0 Unlocked Parameters are editable 1 RDM Parameters cannot be edited via RDM Locked When delivered, the device is always Unlocked. The Lock Pin (PIN Code) is required to change the Lock State parameter. The RDM parameters Identify Device, Reset Device and Display Level can always be executed, regardless of the lock state. DMX/RDM-Sensor 4 13 Factory Reset To reset the DMX/RDM-Sensor 4 into delivery status, select and execute the parameter FACTORY_DEFAULTS via RDM. DMX/RDM-Sensor 4 14 Dimension All details in mm DMX/RDM-Sensor 4 15 Accessory Top-hat rail housing 350 Top-hat rail housing 350flat Wall bracket for top-hat rail housing Power supply 12V DMX/RDM-Sensor 4 16 Revision History Firmware V1.00 - First Release DMX/RDM-Sensor 4 17 CE-Conformity This assembly (board) is controlled by a microprocessor and uses high frequency. In order to maintain the properties of the module with regard to CE conformity, installation into a closed metal housing in accordance with the EMC directive 2014/30/EU is necessary. Disposal Electronical and electronic products must not be disposed in domestic waste. Dispose the product at the end of its service life in accordance with applicable legal regulations. Information on this can be obtained from your local waste disposal company. Warning This device is no toy. Keep out of the reach of children. Parents are liable for consequential damages caused by nonobservance for their children. DMX/RDM-Sensor 4 18 Risk-Notes You purchased a technical product. Conformable to the best available technology the following risks should not excluded: Failure risk: The device can drop out partially or completely at any time without warning. To reduce the probability of a failure a redundant system structure is necessary. Initiation risk: For the installation of the board, the board must be connected and adjusted to foreign components according to the device paperwork. This work can only be done by qualified personnel, which read the full device paperwork and understand it. Operating risk: The Change or the operation under special conditions of the installed systems/components could as well as hidden defects cause to breakdown within the running time. Misusage risk: Any nonstandard use could cause incalculable risks and is not allowed. Warning: It is not allowed to use the device in an operation, where the safety of persons depend on this device. DMX4ALL GmbH Reiterweg 2A D-44869 Bochum Germany Last changes: 24.09.2024 © Copyright DMX4ALL GmbH All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another procedure) without written permission or processed, multiplied or spread using electronic systems. All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless, errors are to be excluded not completely. It is pointed out that neither a guarantee nor the legal responsibility or any liability for consequences which are due to incorrect information is assumed. This document does not contain assured characteristics. The guidance and the features may be changed at any time and without previous announcement.