13 hours ago — WARNING: The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is ...
1 day ago — WARNING: The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is ...
INSTALLATION MANUAL Z102 PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user's safety at risk. The word ATTENTION preceded by the symbol indicates conditions or actions that could damage the instrument or connected equipment. The warranty shall become null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed. WARNING: The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is available using the QR-CODE shown on page 1. The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electrostatic discharges. Take appropriate measures during any operation. Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling). The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste. Z102 DOCUMENTATION SENECA s.r.l.; Via Austria, 26 35127 PADOVA ITALY; Tel. +39.049.8705359 - Fax +39.049.8706287 CONTACT INFORMATION Technical support supporto@seneca.it Product information commerciale@seneca.it This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes. MI00621-1-EN INSTALLATION MANUAL 1/4 MODULE LAYOUT 17.5 mm 111 mm 102.5 mm 1 2 3 4 5 6 PWR FAIL ZERO SPAN 7 8 9 SW1 SW2 Dimensions LxHxD: 17.5 x 102.5 x 111 mm; Weight: 110 g; Enclosure: PA6, black SIGNALS VIA LED ON FRONT PANEL LED STATUS PWR On Off FAIL On TECHNICAL SPECIFICATIONS LED meaning Device powered Device not powered Input in error CERTIFICATIONS POWER SUPPLY Voltage: 10 ÷ 40Vdc; 19 ÷ 28Vac 50 ÷ 60Hz, Absorption: Max.: 2.0 W INPUT Resistor with rheostat connection (2 wires): fields 0 ÷ 300 (I = 6 mA), 0 ÷ 500 (I = 3.6 mA) and 0 ÷ 1K (I = 1.8mA). Resistor with potentiometer connection (3 wires): 200 ÷ 1M (Vref = 1.8 Vcc). OUTPUT Current 0..20 / 4..20 mA, max load resistance 600. Voltage 0..5 V / 0..10 V / 1..5 V / 2..10 V, min load resistance 2000. Operating temperature: from -25°C to +70°C ENVIRONMENTAL Humidity: 10% ÷ 90% non condensing. CONDITIONS Storage temperature: from -30°C to +85°C Protection rating: IP20 POWER SUPPLY/ OUTPUT PROTECTION against impulse voltage overload 400W/ms. PASS-BAND 15 Hz; Response time 10%-90%: 20ms ERRORS RELATED TO THE INPUT MEASURING RANGE: FACTORY CALIBRATION ERROR For rheostat input: 0.3%; For potentiometer input: 1%. THERMAL COEFFICIENT LINEARITY ERROR 0.02%/°C 0.05% MI00621-1-EN INSTALLATION MANUAL 2/4 ELECTRICAL CONNECTIONS CAUTION Switch the module off before connecting inputs and outputs. To meet the electromagnetic immunity requirements: - use shielded signal cables; - connect the shield to a preferential instrumentation earth system; - separate shielded cables from other cables used for power installations (transformers, inverters, motors, etc...). POWER SUPPLY Vac / Vdc 1 Vac / Vdc 2 3 The upper power supply limits must not be exceeded, as this might cause serious damage to the module. The power supply source must be protected from any failures in the module by means of a suitably sized fuse. INPUTS Rheostat connection (2 wires): SW1 SW1 SW1 7 8 9 Potentiometer connection (3 wires): For potentiometer between 200 and 1M SW1 7 8 9 NOTE: DIP 4 of DIP-SWITCH SW1 is reserved for internal uses. OUTPUTS ACTIVE OUTPUT CURRENT 1 2 3 + mA 6 For the current output, the ACTIVE connection must be used when the output loop must be powered directly by the module, while the PASSIVE connection must be used if the current loop supply comes from outside. The module can drive a maximum load of 600, on the loop, with loop power supply protected against short circuit. PASSIVE OUTPUT 1 2 3 4 VOLTAGE OUTPUT 4 5 6 + mA + Vext V + SW2 DIP-SWITCH 1 2 3 4 OUT 0 ÷ 5V 1 ÷ 5V 0 ÷ 10V 2 ÷ 10V 0 ÷ 20mA 4 ÷ 20mA MI00621-1-EN INSTALLATION MANUAL 3/4 INSTALLATION REGULATIONS The module has been designed for vertical installation on a DIN 46277 rail. For optimal operation and long life, adequate ventilation must be provided. Avoid positioning ducting or other objects that obstruct the ventilation slots. Avoid mounting modules over heat-generating equipment. Installation in the bottom part of the electrical panel is recommended. HARSH OPERATING CONDITIONS The following constitute harsh operating conditions: · High power supply voltage (> 30Vdc / > 26Vac). · Sensor power supply at input. · Using the impressed current output. When the modules are mounted side by side it may be necessary to separate them by at least 5 mm in the following cases: · Panel temperature above 45°C in at least one of the above harsh operating conditions. · Panel temperature above 35°C in at least two of the above harsh operating conditions. MI00621-1-EN INSTALLATION MANUAL 4/4Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)