Instructions for HIOKI models including: BT5525, BT5525 Sample Application, BT5525 Application, Sample Application, Application

HIOKI

BT5525 Sample Application Manual

PDF preview unavailable. Download the PDF instead.

BT5525SampleApplicationManual en 02
Revision 02
BT5525 Sample Application Manual
Overview BT5525 Sample Application (this application) can perform the following operations on the BT5525:  Setting for BT5525  Display of measured values (measurement or update of measured values at specified time
intervals)  Backup and Restoration of the instrument's settings  Sending and receiving communication commands  Displaying and saving monitor data  Displaying and saving BDD data
System requirements  CPU: 1 GHz or greater  Memory: 512 MB or more  OS: Windows10, Windows11  Microsoft .NET Framework 6.0  Interface: USB 2.0 (virtual COM port), LAN  Monitor resolution: 1024 x 768 dots or greater  Hard disk: 5 MB free space or more (However, if .NET Framework 6.0 is not installed,
approximately 2.5 GB is required separately)
Installing the application 1. Double-click " setup_BT5525 Sample Application.exe". 2. The installer screen will appear. 3. Click Next every time when it appears. 4. Installation will begin. When the installation is complete, a shortcut icon
will be created on the desktop.
Uninstalling the application  Windows10, 11 The application can be uninstalled by opening the Windows Setting, choosing Apps.
Connecting the instrument to your computer  Connecting the instrument via USB
Works with standard Windows drivers.
1

 Connecting the instrument via LAN You'll need a LAN cross cable.

Revision 02

Launching and connecting to the application 1. Double-click the application's shortcut on the desktop. The measurement screen will be displayed. 2. Select the Function and Interface then click [Connect].

3. If you get an error message like the one on the right, please make sure that you are using the correct IP address and port. Also, the port may be used by other applications.
Application interface This application will force the following settings upon connection. When the application is closed, the following settings will be restored to the original settings at the time of connection. If it does not exit successfully or cannot communicate on exit, the settings remain as follows.
Response of measured value and status. :MEASure:VALid 255 Command monitor OFF. Automatic data output setting OFF.
2

Selecting the delimiter character for text (CSV) files  This application has the ability to save data to a text (CSV) file  You can set the separator used for data delimitation from the menu.
Please set the separator according to your environment.
Comma (",") separator Semicolon (";") separator

Revision 02

3

Revision 02

Insulation Resistance Test Insulation Resistance Test
Operate this instrument from the application to perform an insulation resistance test.

 Overview of Main Screen  When this application is launched, it synchronizes with the settings of the instrument.  When you change the settings on the screen, the settings on the instrument will automatically change as well. Please note that if you change the settings from the
instrument, the settings on the screen will not be reflected.

You can set up and check the instrument.

Displays the measured value.

Displays measurement results.

Interval Measurement Records test results at each set time interval.

Press the button to perform the TEST, which can also be operated with the F5/F4 keys.

4

 MEAS1MEAS2  All test settings that can be configured on the instrument can be changed.

Revision 02

 COMPARATOR SETTING

Reflects the setting in this instrument.

 PANEL
Specify the panel number. 

 Saves the settings to the specified panel number. If panel data already exists, it is overwritten.
 Loads the settings for the specified panel number.
 Renames the specified panel number. (Max. 10 single-byte alphanumeric characters)
 Deletes the setting of the specified panel number.
5

 SYS, IF

Revision 02

 [RESET] : The settings of the instrument other than the communication settings and panel are initialized.
 LAN: To change the LAN settings, press [Reflect]. The instrument's LAN settings will not be changed until [Reflect] is pressed; if a LAN connection has been made, it will be reconnected.
 Some functions cannot be set from the application.
 INFO Information on this instrument can be checked.
 Obtains error information from the instrument. For details on various errors, refer to the ":SYSTem:ERRor?" command page in the instrument's instruction manual.
6

 Various Tools The following windows open from [Tool] on the top toolbar. When the window is closed, it returns to the original screen. The instrument will be synchronized with the instrument at that time.
 Command test

Revision 02

Send and receive arbitrary commands.

 Backup  Restore

 Backs up the instrument's settings and saves a dedicated settings file.
 Check the items to be backed up and click [Backup] to open the folder selection screen. When "Complete Backup" is displayed, the backup is complete. If multiple PANELs are set up, it may take some time.
 Restore the instrument's settings from the dedicated settings file created by the above backup.
 Press [File] and select the backup file from the folder.
 Press [Restore] to execute the restoration, which is complete when "Complete Restore" is displayed. If multiple PANELs are set up, it may take some time.
7

BDD Analysis

Revision 02

BDD Analysis

Insulation resistance test is performed, and when the test stops, monitor voltage and current values

(reference values) from the start of the test are acquired, displayed on the data grid, and waveforms

are displayed on the graph.

Waveform data can be saved as CSV. (Note that this is different from the actual detection waveform

of the BDD function.)

 Overview of Main Screen  When this application is launched, it synchronizes with the settings of this instrument.  When the screen settings are changed, the settings of this unit are automatically changed as
well.

Press the button to perform the test.

You can set up and check the instrument. Displays monitor data and BDD data acquired after the test.

Display a graph of monitored data and a list of test results.

8

 SETTING  Graph setting
 BDD setting

Revision 02
 Sets the number of waveforms sampled.  Sets the degree to which sampled waveforms
are thinned out. Larger values result in lower resolution, but allow acquisition of waveforms of longer duration.  The recording time with the above settings is shown.  If checked, the voltage and current graphs are displayed separately.
Enable BDD setting, set threshold  CCV: Detects V in CC (charging) state  CVV: Detects V in CV (steady) state  CVI: Detects I in CV (steady) state  When turned ON, the test is stopped when the
BDD count reaches 1 or more.

 TEST
Displays the test status of the instrument. IDLE: Waiting TEST: Testing DISCHARGE: Discharging INTERLOCK: Waiting at interlock

Displays measurement results.

Displays the number of BDD counts and their breakdown.

When checked, the test status of this instrument is monitored; check this box if you want to control the test with EXT I/O. The operation of this instrument will not be possible because it will always be in the remote state (RMT). Uncheck the check box if you want to operate the instrument.
9

 BDD data / MONITOR data  Graph / TEST data

Revision 02
 After the test STOP, it is read from the instrument and the display is updated.
 It can be saved as CSV by [SAVE].  Vmoni and Imoni are reference values.  BDD data displays the result when BDD
COUNT is 1 or more, and the unit of BDD value is [V] when Type is CCV or CVV, and [%] when CVI. Note that the % of CVI is a percentage of the BT5525's own reference value and cannot be converted to a current value.
Graph  Displays monitor value
waveforms of voltage and current.  Displays the detection time and magnitude of BDD as dots with bars.  Move, zoom in/out, and copy images on the graph by mouse operation.  Check boxes allow you to switch between showing/hiding the waveforms and fixing the axes.
TEST data  Lists the test results. For details, refer to the ":MEASure?" and ":CONTactcheck:CAPacitance?" command pages of the instrument's user manual.
10

 Option The [Tool] on the top toolbar opens the [Option] window.

Revision 02

 Auto save function

 At the end of the test, the checked items are automatically saved in CSV format. If none of the items are checked, the file will not be automatically saved.
 Enter the location to save the CSV file.  Click [OK] to save the settings and apply
them from the next test.

The file name to be saved automatically changes depending on the data checked. File name  yyyy-MM-dd_HH-mm-ss_auto_xxxx.csv xxxx is the type of storage and number of data
Date and time the file was saved, information.
 Measurement Setting Saves when SETTING is checked.
 TEST result Saves when TEST data is checked.

 BDD data, MONITOR data If either BDD data or MONITOR data is checked, it will be saved. If both BDD data and MONITOR data are checked, both data are combined and sorted by Time and saved.

11

 Application acceleration

Revision 02
 Checking the option speeds up the operation of this application. If you have a lot of data you want to auto-save and the test interval is short, etc., and data cannot be read out in time, please try speeding up the process.
 Press [OK] to save and apply the settings.

Disclaimer This application is free software. HIOKI ELECTRIC CO., LTD. assumes no responsibility for any damage caused by the use of this application. Also, HIOKI Electric Corporation assumes no responsibility for any bugs or other inconveniences that may occur with the software. Please note that HIOKI is unable to respond to questions about this software. Thank you for your understanding.
12


Microsoft Word 2013 Microsoft Word 2013