INSTRUCTIONS FOR USE: To ensure proper operation of the delivery set, please follow all instructions and illustrations below. INF1200-E 1200ml Enteral Pump Delivery ...

INF1200-E


File Info : application/pdf, 1 Pages, 443.40KB

PDF preview unavailable. Download the PDF instead.

INF1200-E-IFU
1200ml Enteral Pump Delivery Set with ENFit® Connector

INF1200-E
Zevex, Inc. Salt Lake City, Utah 84123 USA
USA toll free: (800) 970-2337 tel: (801) 264-1001
www.infinityfeedingpump.com

INSTRUCTIONS FOR USE: To ensure proper operation of the delivery set, please follow all instructions and illustrations below.

1. Fill feeding bag to desired level and close cap securely.

5. To expel air from tube using pump prime feature, refer

A

B

2. Unscrew the protective cover counterclockwise from the ENFit connector (image A).

to pump and Operator's Manual for instructions.

Note: If set is to be used with a carry pack, all air must be removed from the bag and tubing. Continue to step #3 for instructions on removing the air. If set is

Note: Priming with the pump

is recommended when using

thick formulas because it is

faster than priming by gravity.

C

D

to be hung above pump, i.e. on an IV pole,

6. Position silicone tubing

air may remain in bag. Skip to step #4.

around pump wheel stretching

3. Turn bag upside down and gently squeeze. Tilt bag to keep air at the tubing port (image B). At the same time, follow the instructions in step #4.

lightly. Seat cassette into the pump (image D). Close pump door.

4. Gently pinch the teal colored tubing below the " " symbol (image C). Hold this position until air is expelled from tubing. Gently squeeze bag at the same time to assist fluid flow. If

7. Screw the ENFit connector
clockwise into feeding tube firmly by hand (image E). Be careful not to overtighten.

E

fluid does not flow, pinch may be too tight.

WARNINGS AND PRECAUTIONS
· It is important to keep the air sensor free of debris including spilled fluids or food that may adhere to the sensor and prevent detection of air in the tubing. Use a cotton swab to clean the pathways of the cassette receptacle. (Refer to the pump Operator's Manual for further cleaning instructions).
· When using a programmed dose, infinite dose or interval feeding setting, the volume of food in the bag/bottle should be monitored throughout the feeding cycle to ensure the appropriate dose has been received by the patient.
· Follow manufacturer guidelines related to maximum nutrition hang time.
· Device contains small parts. Dispose of or store connector cap when not in use to avoid choking hazard for children under 3 years.

· Avoid leaving tubing and cords where infants, children, or those deemed at high risk for medical line entanglement, can become entangled. Be aware that if these items become wrapped around a patient's neck, there is an increased risk of strangulation or death. Caregivers of patients who are at risk for entanglement should discuss with their health care provider how to properly manage their lines and properly monitor patients based on their needs while in use.
WARNING: This product can expose you to chemicals including vinyl chloride, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.

THE INFINITY DELIVERY SET IS INTENDED TO
CONNECT TO ENTERAL FEEDING TUBES

NOT MANUFACTURED WITH NATURAL RUBBER LATEX

DELIVERY SETS ARE MADE WITH MATERIALS THAT DO NOT CONTAIN
BISPHENOL A (BPA) IN THE FLUID PATH.