User Guide for Edge-core models including: ECS5520-18X, ECS5520-18T, ECS5520-18X 16 Port L2 Plus 10G Switch with Two 40G Uplinks, ECS5520-18X, 16 Port L2 Plus 10G Switch with Two 40G Uplinks, L2 Plus 10G Switch with Two 40G Uplinks, Two 40G Uplinks, Uplinks

ECS5520 Series Quick Start Guide

Edgecore Networks Corporation

Download

ECS5520-18T – Edgecore Networks

ECS5520-18X – Edgecore Networks


File Info : application/pdf, 4 Pages, 614.27KB

ECS5520-18X-18T QSG-R01 1205
Quick Start Guide
16-Port L2+/L3 Lite 10G Switch with Two 40G Uplinks
ECS5520-18X | ECS5520-18T
Package Contents

www.edge-core.com

1

2

3

4

5

6

1. ECS5520-18X or ECS5520-18T (with 1 AC PSU) 2. Rack Mounting Kit--2 brackets and 8 screws 3. Four adhesive rubber feet 4. Power cord
Caution: This equipment is not suitable for use in locations where children are likely to be present. Attention: Cet équipement ne convient pas à une utilisation dans des endroits où des enfants sont susceptibles d'être présents.
1 Mount the Switch
1
2

5. Console cable--RJ-45 to DB-9 6. Documentation--Quick Start Guide (this document) and Safety
and Regulatory Information

Caution: The device must be installed in a restricted-access location. It should have a separate protective earthing terminal on the chassis that must be permanently connected to earth to adequately ground the chassis and protect the operator from electrical hazards. Attention: L'appareil doit être installé dans un emplacement à accès restreint. Il doit comporter une borne de terre de protection distincte sur le châssis, qui doit être connectée en permanence à la terre pour assurer une mise à la terre adéquate du châssis et protéger l'opérateur des risques électriques.
3 Connect Power

a. Connecting AC Power

1

2

3

1. Attach the brackets to the switch. 2. Use the screws and cage nuts supplied with the rack to secure the
switch in the rack. Note: The switch can also be installed on a desktop or shelf using the included adhesive rubber foot pads.
2 Ground the Switch
1
2

1. PSU Vendor: Great Wall model GW-T150WV12 2. PSU Vendor: UMEC model UPD1501SA 3. Install one or two universal AC PSUs in the switch and connect an
external AC power source to the PSUs.

Note: For international use, you may need to change the AC line cord. You must use line cord sets that have been approved for the socket type in your country.
Note: AC PSUs from different vendors must not be installed at the same time.

b. (Optional) Connecting DC Power

1

1

1. Ensure the rack on which the switch is to be mounted is properly grounded and in compliance with ETSI ETS 300 253. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment)
2. Attach a lug (not provided) to a #18 AWG minimum grounding wire (not provided), and connect it to the grounding point on the switch rear panel. Connect the other end of the wire to rack ground.
Caution: The earth connection must not be removed unless all supply connections have been disconnected. Attention: Le raccordement à la terre ne doit pas être retiré sauf si toutes les connexions d'alimentation ont été débranchées.

3 2

A

B

C

1

1. Install one or two DC PSUs in the switch.
2. Connect the DC power supply wires to the supplied connector as follows:  A ­ Blue Wire: DC Return  B ­ Brown Wire: -36 ­ -72 VDC  C­ Yellow Wire - Chassis Ground



­ 1 ­

E122023-CS-R01 150200002649H

Quick Start Guide

3. Insert the DC supply connector into the DC PSU power input socket. Caution: Use a UL/IEC/EN 60950-1 and/or 62368-1 certified power supply to connect to a DC converter, and #18 AWG wire to connect to a DC PSU. Attention: Utilisez une alimentation certifiée UL/IEC/EN 60950-1 et/ou 62368-1 pour le connecter à un convertisseur CC et un câble AWG #18 pour vous connecter à une alimentation CC.
4 Verify Switch Operation
1
1
1. Verify basic switch operation by checking the system LEDs.When operating normally, the PSU1/PSU2 and the DIAG LED should all be on green.
5 Perform Initial Configuration
1. At this point you may need to make a few basic switch configuration changes before connecting to the network. It is suggested to connect to the switch console port to perform this task.
2. The serial port's configuration requirements are as follows: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.
3. You can log in to the command-line interface (CLI) using default settings: User "admin" with password "admin".
1
4. For information on initial switch configuration, refer to the CLI Reference Guide.
6 Connect Network Cables

2. As connections are made, check the port status LEDs to be sure the links are valid:  On/Blinking Green -- Port has a valid link. Blinking indicates network activity

Hardware Specifications

Switch Chassis Size (WxDxH)
Weight Temperature

ECS5520-18X: 43.8 x 28.0 x 4.3 cm (17.26 x 11.02 x 1.71 in.) ECS5520-18T: 44.0 x 28.0 x 4.4 cm (17.32 x 11.02 x 1.73 in.)
ECS5520-18X: 3.9 kg (8.6 lb) with 1 PSU ECS5520-18T: 4.1 kg (9.04 lb) with 1 PSU
Operating: 0° C to 50° C (32° F to 122° F), ECS5520-18T 0° C to 55° C (32° F to 131° F) Storage: -40° C to 70° C (-40° F to 158° F)

Humidity

Operating: 5% to 95% (non-condensing)

AC PSU Power Specification (Great Wall model GW-T150WV12)

AC Input Power

100­240 VAC 50­60 Hz, 3­1.5 A

PSU Power Rating 150 W x 2 AC PSU

AC PSU Power Specification (UMEC model UPD1501SA)

AC Input Power

100­240 VAC 50­60 Hz, 4­2 A

PSU Power Rating 150 W x 2 AC PSU

DC PSU Power Specification

DC Input Power

-36­ -72 VDC, 6­3 A

PSU Power Rating 150 W x 2 DC PSU

Regulatory Compliances

Emissions

EN 55032 EN 61000-3-2, Class A EN 61000-3-3 FCC, Class A VCCI, Class A AS/NZS CISPR 32 ICES-003 Issue 7 Class A CNS 15936

Immunity

EN55035

Safety

UL (CSA 22.2 No 62368-1 & UL 62368-1) CB (IEC/EN 62368-1) BSMI CNS 15598-1

Taiwan RoHS

CNS 15663

2

1
1. For the SFP/SFP+/QSFP+ slots, first install SFP/SFP+/QSFP+ transceivers and then connect fiber optic cabling to the transceiver ports. The following transceivers are supported:  1000BASE-SX (ET4201-SX)  1000BASE-LX (ET4201-LX)  10GBASE-SR (ET5402-SR)  10GBASE-LR (ET5402-LR)  40GBASE-SR4 (ET6401-SR4)  40GBASE-LR4 (ET6401-LR4)

­ 2 ­


10G
ECS5520-18X | ECS5520-18T



www.edge-core.com

1
1. ECS5520-18X  ECS5520-18T (  AC  ) 2.  3. 4 
 : 
1 

2

3

4

5

6

4.  5.  --RJ-45  DB-9 6.  --  

3 

a.  AC 

1

2

3

1
2
1.  2. 
 : 
2 
1

1. PSU Vendor: Great Wall model GW-T150WV12 2. PSU Vendor: UMEC model UPD1501SA 3.  1  2  AC  AC 


 :    :  AC 
b. (  )  DC 

1

1

3 2

2
1.  ETSI ETS 300 253   
2.  18  AWG    :   :   

A

B

C

1

1.  1  2  DC 
2.   A ­  : DC   B ­  : -36 ­ -72 VDC  C ­  : Chassis Ground
3.  DC  DC PSU 

 :  DC Converter  UL/IEC/EN 609501  /  62368-1  DC PSU  #18 AWG  DC 

­ 3 ­



4 
1 1
1.  LED PSU1/PSU2  DIAG 
5 
1.  2. 115200 bps8 1 
8  3.  (  admin admin ) 
 (CLI)
1
4.  CLI 
6 
2
1
1.  SFP/SFP+/QSFP+  SFP/SFP+/QSFP+   :  1000BASE-SX (ET4201-SX)  1000BASE-LX (ET4201-LX)  10GBASE-SR (ET5402-SR)  10GBASE-LR (ET5402-LR)  40GBASE-SR4 (ET6401-SR4)  40GBASE-LR4 (ET6401-LR4)
2.  LED   /  --  





 (WxDxH)

ECS5520-18X: 43.8 x 28.0 x 4.3 cm (17.26 x 11.02 x 1.71 in.) ECS5520-18T: 44.0 x 28.0 x 4.4 cm (17.32 x 11.02 x 1.73 in.)



ECS5520-18X: 3.9 kg (8.6 lb)  1  ECS5520-18T: 4.1 kg (9.04 lb)  1 



 : 0° C to 50° C (32° F to 122° F), ECS5520-18T 0° C to 55° C (32° F to 131° F)  : -40° C to 70° C (-40° F to 158° F)



 : 5% to 95% (  )

AC PSU  (Great Wall model GW-T150WV12)

AC 

100­240 VAC 50­60 Hz, 3­1.5 A

PSU Power Rating 150 W x 2 AC PSU

AC PSU  (UMEC model UPD1501SA)

AC 

100­240 VAC 50­60 Hz, 4­2 A

PSU Power Rating 150 W x 2 AC PSU

DC PSU  DC 

-36­ -72 VDC, 6­3 A

PSU Power Rating 150 W x 2 DC PSU





EN 55032 EN 61000-3-2, Class A EN 61000-3-3 FCC, Class A VCCI, Class A AS/NZS CISPR 32 ICES-003 Issue 7 Class A CNS 15936

 

EN55035
UL (CSA 22.2 No 62368-1 & UL 62368-1) CB (IEC/EN 62368-1) BSMI CNS 15598-1

Taiwan RoHS

CNS 15663

­ 4 ­



References

Adobe PDF Library 17.0