Instruction Manual for Elitech models including: Repeated LogEt 260 4G Real Time Temperature and Humidity Data Logger, Repeated LogEt 260, 4G Real Time Temperature and Humidity Data Logger, Real Time Temperature and Humidity Data Logger, Temperature and Humidity Data Logger, Humidity Data Logger, Data Logger, Logger

LogEt 260外贸说明书-20240517

[PDF] LogEt 260外贸说明书

Page 5. Technical parameter. 1.Add equipment. Log on to the platform website: http://new.i-elitech.com, or scan the code to download and install the APP.

Elitech Loget 260 Product Instruction

Elitech Loget 260-TH 4G Real-time Temperature & Humidity Data Logger — ElitechEU

Tải xuống

Nhiệt ẩm kế tự ghi 4G Elitech Loget 260-TH - Elitech Việt Nam


File Info : application/pdf, 8 Pages, 5.02MB

PDF preview unavailable. Download the PDF instead.

huong-dan-su-dung-elitech-loget-260-th
Repeated LogEt 260 instruction manual
Platform login website: https://new.i-elitech.com

Safety Instructions
To ensure installing and using the product correctly, please read carefully and abide by the following instructions:
Battery  Please use the original battery rather than any other ones, to avoid possible damage or error to device.  Do not disassemble battery without permission. No squeezing, hitting, heating or burning the battery, otherwise battery may explode and lead to a fire.
External Power Supply  When need external power supply, please use the provided power adapter. Any other power adapter which does not meet the technical specifications is not allowed. Otherwise, due to which, the device may be damaged, or even cause a fire. 
the activity of lithium cell.
Device  This device is prohibited to be used in environments with flammable or explosive gas, otherwise, an explosion/fire may be caused.  contact manufacturer or supplier.
Precautions
° If the device will not be in use for a long period of time, the device should be removed and stored in the package box in a dry and cool environment.
° even damage the device.
° Do not use the device outdoors, to avoid short circuit, burn, and other malfunctions caused by bad weather such as raining and thunder-lightings.
° networking status.
° Use the data logger within its measurement range. ° Do not impact the data logger with force. °
³ Temperature deviation: Stabilizing time too short for placing the device in the measurement environment. Near or even exposed to a heat/cold source.
³ Humidity deviation: Stabilizing time too short for placing the device in the measurement environment. Long time exposed in steam, fog, waterfall or condensation environment.
³ Pollution: Exposed to dust or other polluted environment.

Product presentation
This product integrates temperature, light, vibration monitoring and 4G network functions. The product adopts high-precision sensor with high measurement accuracy, which can be applied to the collection and monitoring of temperature and humidity data in various complex environments. Interact with the device through the cloud platform or APP to set parameters, view and export data.


 















Backmounted hanging hole Start-stop button Power supply + data interface Activation / Flight mode button

 Liquid crystal display  Serial number  Built-in sensor  External sensor

 LED pilot lamp  Light sensor

  

 


Operative mode  Function declaration  Airplane mode  Signal condition

Battery capacity  Light and vibration alarm signs

Time and the number of record notes

 Temperature and humidity value

Note: To ensure the reliability of the data, when the battery power is less than 10% to 20%, please do not open the record (20%)
1

Selection table
(standard light and vibration sensors)

Model LogEt 260 T LogEt 260 TH

LogEt 260 TE

LogEt 260 THE

LogEt 260 TLE

Probe Type

Built-in temperature

Built-in T&H

External + internal temperature

External T&H+ internal temperature

External ultra low T + internal temperature

Measuring Range

-30°C~60°C

-30°C ~ 60°C 0%RH~100%RH

-40°C ~ 85°C

External:-200°C ~ 150°C External:-200°C ~ 150°C

Built-in: -30°C ~ 60°C

Built-in: -30°C ~ 60°C

Accuracy

±0.5°C

±0.5°C ±5%RH

±0.5°C

±0.5°C ±5%RH

±0.5°C (-40°C~85°C) ±1°C (100°C~150°C)
±2°C (other)

Note: The built-in probe should not be used when charging, so as not to cause abnormal temperature; Do not charge in the environment below 0°C;

Technical parameter

Shock range Light intensity range Resolution ratio Button Led light Display screen Location mode Memory point Shadow data Interrecord gap Upload interval Data upload method Mode of starting freight Freight stop mode Repeat the start Airplane mode Alarm mode Battery type OTA upgrade Classification of waterproof Work environment Storage environment Specification and dimension

0g~16g 0~52000Lux 0.1°C/0.1%RH/0.1g/1Lux Double button design Red and green, red and blue LED indicator lights Broken code display LBS + GPS 10W Prestant +Afterstop 1min~24h; default: 5min 5min~24h; default: 60min 4G Button pressing, platform, and timing Button, platform, and fill up 3 times (not off shelf life) Key button, timing, electronic fence Overlimit, low power 3.7 V polymer lithium battery 3000mAh Upgrade is available through the data management software and the platform IP65 (built-in) -30°C~70°C, 0% RH~100% RH (no condensation) 15~30°C20~75%RH 103 x 61.3 x 30 (mm)

2

Technical parameter
1.Add equipment Log on to the platform website: http://new.i-elitech.com, or scan the code to download and install the APP Register, sign in, and add devices as prompted.

2.Activation Long press the button for 5 seconds, and the
screen appears normally, indicating that the device is activated.
Note: Click the button screen to display normally, indicating that the device is activated;

3.Airplane mode
Open: long press the button for 5 seconds, the screen is successfully started;

display logo indicates that the flight mode

Close: long press the button for 5 seconds, the screen

sign indicates that the flight mode is closed;

Note: For other flight modes, please operate through the platform or APP.

4.Start the record
Press the button for 5 seconds and the screen  sign indicates the startup record; if the sign is flashing, the delay countdown state is entered. After the delay, the record starts automatically;

5.Stop recording
Long press the button for 5 seconds, the screen display µsign instructions to stop recording successfully;

3

6.Data export
The device is connected to the computer USB interface through the data cable, and automatically generates data reports in PDF + CSV format. You can copy the generated report to your computer for saving.

Report generation

Device is connected to the computer

The LED indicator light has the instructions

Device Status/Operation Malfunction/Low Battery (below 5%) No Calibration No Activation No Start Start Recording Delayed/Scheduled Start
Recording
Stop Recording
Recording Stopped
Report Generating USB Connecting Clear Report Label Communication Normal Communication Error Start Airplane Mode Stop Airplane Mode Clear the report logo

LED Indicator Display No Flashing Green & Red Flashing x 2 Red & Red Flashing x 2 Green & Red Flashing x 1 Green Flashing x 5 Green to Red Flashing x 1 Green Flashing x 1 (OK) Red Flashing x 1 (Alarming) Red Flashing x 5 Green Flashing x 2 (OK) Red Flashing x 2 (Alarming) Green to Red Flashing x 1 Green & Red On Green & Red Flashing Blue Flashing x 3 Red & Blue Flashing x 3 Blue Flashing x 5 Blue Flashing x 5 At the same time flashing

Triggering Method Short Press Button Short Press Button Short Press Button Short Press Button Short Press Button x 5s
Short Press Button x 10s or Auto Flashing
Long Press Right Button x 5s
Short Press Button
/ Connect USB Long Press Left Button x 5s Flashing When Connecting to Network Flashing When Connecting to Network Long Press Left Button x 5s Long Press Left Button x 5s Long Press Left Button x 5s (USB connected)

4

LCD explicit declaration
Record points Current time Data not uploaded, unable to open

not uploaded points low battery probe fault

5

V 1.0



References

Adobe PDF library 17.00 Adobe Illustrator(R) 24.0