Instruction Manual for Elitech models including: Repeated LogEt 260 4G Real Time Temperature and Humidity Data Logger, Repeated LogEt 260, 4G Real Time Temperature and Humidity Data Logger, Real Time Temperature and Humidity Data Logger, Temperature and Humidity Data Logger, Humidity Data Logger, Data Logger, Logger
Page 5. Technical parameter. 1.Add equipment. Log on to the platform website: http://new.i-elitech.com, or scan the code to download and install the APP.
Elitech Loget 260-TH 4G Real-time Temperature & Humidity Data Logger — ElitechEU
Nhiệt ẩm kế tự ghi 4G Elitech Loget 260-TH - Elitech Việt Nam
File Info : application/pdf, 8 Pages, 5.02MB
DocumentDocumentRepeated LogEt 260 instruction manual Platform login website: https://new.i-elitech.com Safety Instructions To ensure installing and using the product correctly, please read carefully and abide by the following instructions: Battery Please use the original battery rather than any other ones, to avoid possible damage or error to device. Do not disassemble battery without permission. No squeezing, hitting, heating or burning the battery, otherwise battery may explode and lead to a fire. External Power Supply When need external power supply, please use the provided power adapter. Any other power adapter which does not meet the technical specifications is not allowed. Otherwise, due to which, the device may be damaged, or even cause a fire. the activity of lithium cell. Device This device is prohibited to be used in environments with flammable or explosive gas, otherwise, an explosion/fire may be caused. contact manufacturer or supplier. Precautions ° If the device will not be in use for a long period of time, the device should be removed and stored in the package box in a dry and cool environment. ° even damage the device. ° Do not use the device outdoors, to avoid short circuit, burn, and other malfunctions caused by bad weather such as raining and thunder-lightings. ° networking status. ° Use the data logger within its measurement range. ° Do not impact the data logger with force. ° ³ Temperature deviation: Stabilizing time too short for placing the device in the measurement environment. Near or even exposed to a heat/cold source. ³ Humidity deviation: Stabilizing time too short for placing the device in the measurement environment. Long time exposed in steam, fog, waterfall or condensation environment. ³ Pollution: Exposed to dust or other polluted environment. Product presentation This product integrates temperature, light, vibration monitoring and 4G network functions. The product adopts high-precision sensor with high measurement accuracy, which can be applied to the collection and monitoring of temperature and humidity data in various complex environments. Interact with the device through the cloud platform or APP to set parameters, view and export data. Backmounted hanging hole Start-stop button Power supply + data interface Activation / Flight mode button Liquid crystal display Serial number Built-in sensor External sensor LED pilot lamp Light sensor Operative mode Function declaration Airplane mode Signal condition Battery capacity Light and vibration alarm signs Time and the number of record notes Temperature and humidity value Note: To ensure the reliability of the data, when the battery power is less than 10% to 20%, please do not open the record (20%) 1 Selection table (standard light and vibration sensors) Model LogEt 260 T LogEt 260 TH LogEt 260 TE LogEt 260 THE LogEt 260 TLE Probe Type Built-in temperature Built-in T&H External + internal temperature External T&H+ internal temperature External ultra low T + internal temperature Measuring Range -30°C~60°C -30°C ~ 60°C 0%RH~100%RH -40°C ~ 85°C External:-200°C ~ 150°C External:-200°C ~ 150°C Built-in: -30°C ~ 60°C Built-in: -30°C ~ 60°C Accuracy ±0.5°C ±0.5°C ±5%RH ±0.5°C ±0.5°C ±5%RH ±0.5°C (-40°C~85°C) ±1°C (100°C~150°C) ±2°C (other) Note: The built-in probe should not be used when charging, so as not to cause abnormal temperature; Do not charge in the environment below 0°C; Technical parameter Shock range Light intensity range Resolution ratio Button Led light Display screen Location mode Memory point Shadow data Interrecord gap Upload interval Data upload method Mode of starting freight Freight stop mode Repeat the start Airplane mode Alarm mode Battery type OTA upgrade Classification of waterproof Work environment Storage environment Specification and dimension 0g~16g 0~52000Lux 0.1°C/0.1%RH/0.1g/1Lux Double button design Red and green, red and blue LED indicator lights Broken code display LBS + GPS 10W Prestant +Afterstop 1min~24h; default: 5min 5min~24h; default: 60min 4G Button pressing, platform, and timing Button, platform, and fill up 3 times (not off shelf life) Key button, timing, electronic fence Overlimit, low power 3.7 V polymer lithium battery 3000mAh Upgrade is available through the data management software and the platform IP65 (built-in) -30°C~70°C, 0% RH~100% RH (no condensation) 15~30°C20~75%RH 103 x 61.3 x 30 (mm) 2 Technical parameter 1.Add equipment Log on to the platform website: http://new.i-elitech.com, or scan the code to download and install the APP Register, sign in, and add devices as prompted. 2.Activation Long press the button for 5 seconds, and the screen appears normally, indicating that the device is activated. Note: Click the button screen to display normally, indicating that the device is activated; 3.Airplane mode Open: long press the button for 5 seconds, the screen is successfully started; display logo indicates that the flight mode Close: long press the button for 5 seconds, the screen sign indicates that the flight mode is closed; Note: For other flight modes, please operate through the platform or APP. 4.Start the record Press the button for 5 seconds and the screen sign indicates the startup record; if the sign is flashing, the delay countdown state is entered. After the delay, the record starts automatically; 5.Stop recording Long press the button for 5 seconds, the screen display µsign instructions to stop recording successfully; 3 6.Data export The device is connected to the computer USB interface through the data cable, and automatically generates data reports in PDF + CSV format. You can copy the generated report to your computer for saving. Report generation Device is connected to the computer The LED indicator light has the instructions Device Status/Operation Malfunction/Low Battery (below 5%) No Calibration No Activation No Start Start Recording Delayed/Scheduled Start Recording Stop Recording Recording Stopped Report Generating USB Connecting Clear Report Label Communication Normal Communication Error Start Airplane Mode Stop Airplane Mode Clear the report logo LED Indicator Display No Flashing Green & Red Flashing x 2 Red & Red Flashing x 2 Green & Red Flashing x 1 Green Flashing x 5 Green to Red Flashing x 1 Green Flashing x 1 (OK) Red Flashing x 1 (Alarming) Red Flashing x 5 Green Flashing x 2 (OK) Red Flashing x 2 (Alarming) Green to Red Flashing x 1 Green & Red On Green & Red Flashing Blue Flashing x 3 Red & Blue Flashing x 3 Blue Flashing x 5 Blue Flashing x 5 At the same time flashing Triggering Method Short Press Button Short Press Button Short Press Button Short Press Button Short Press Button x 5s Short Press Button x 10s or Auto Flashing Long Press Right Button x 5s Short Press Button / Connect USB Long Press Left Button x 5s Flashing When Connecting to Network Flashing When Connecting to Network Long Press Left Button x 5s Long Press Left Button x 5s Long Press Left Button x 5s (USB connected) 4 LCD explicit declaration Record points Current time Data not uploaded, unable to open not uploaded points low battery probe fault 5 V 1.0