User Manual for Sunco models including: DL_SMDR56-13W-3K_65K, DL_SMDR56-13W-3K_65K LED Retrofit Selectable Smooth Downlight, LED Retrofit Selectable Smooth Downlight, Retrofit Selectable Smooth Downlight, Selectable Smooth Downlight, Smooth Downlight, Downlight

View

Installation Guides, Manuals, and Specs | Sunco – Sunco Lighting


File Info : application/pdf, 10 Pages, 439.14KB

PDF preview unavailable. Download the PDF instead.

DL SMDR56-13W-3K 65K ManualMasterCopy ?v=170196598
Lighting made better.
User Manual
5/6" LED Retrofit Selectable Smooth Downlight
SKU: DL_SMDR56-13W-3K_65K

support@sunco.com (844) 334-9938

AMERICAN COMPANY

Whats in the Box?
Retrofit Downlight

Le(tlittheerraellbye) light!

x1 Light Fixture

x1 TP24 Connector
1

x1 E26 Base

Before You Start

Safety Information

To reduce the risk of fire, electric shock, or physical injury:

· Turn off circuit breaker before installing this fixture. · This product should be installed by a person familiar with
the construction and operation of the product the hazards involved. Safety eyeglasses and gloves are recommended. · Abide by related regional and local laws or regulations. · Proper grounding is required to ensure safety. · Do not alter, relocate, or remove wiring during installation. · Do not make or alter any open holes in wiring enclosure or electrical components during installation. · Check for shipping damage before insatalling. If the product is damaged, do not use it. · Keep fixture away from corrosive substances.

· Suitable for damp locations at temperature ranging from 4°F to 113°F. Not for use where directly exposed to water.
· Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
· Use safety precautions and abide by regional and local laws or regulations.
· This product is not compatible with 3rd party sensors. · This product is not compatible with photo controls. · This product is not compatible with occupancy sensors. · This product is not compatible with timing devices.
WARNING: Cancer & Reproductive Harm- www.P65Warnings.ca.gov

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.) This device may not cause harmful interference.

2.) This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.

Quickstart Guide

1

2

Step 1
Locate the recessed housing.

Step 2

Step 3

Determine type of connector available.

Thread the adapter to make connection.

22

Step 4
Push downlight into can until secure.

Installation Guide

STEP 1 a. Turn off circuit breaker before installation. b. Locate the housing. NOTE: Remove previous fixture. Fixture may be hot so allow time to cool after turning off power.
STEP 2 a. Determine the size of the opening. b. Secure the clip springs firmly within the retrofit connector.

1

2

STEP 3 Determine the type of connector available. -TP24 Connector(1) -E26 Base(2)
3

Installation Guide (Cont.)
STEP 4 a. Thread the appropriate adapter to make connection in the housing. NOTE: the wires may come lose from the connectors so ensure they are attached.
b. Tuck all wires into the can.

STEP 5

a. On back of retrofit fixture, slide the CCT Selection Switch to

6500K 6000K 5000K

choose from five color temperatures. Try each CCT to

4000K

3000K

determine best fit.

b. Turn off light switch after selecting your choice and continue install.

STEP 6 a. Line up trim ring with opening.
b. Push downlight into can until secure. Compression clips will hold retrofit light in place. Push up spring clips and insert into ceiling.
c. Turn on circuit breaker and test light. 4

Product Details
Recommended Dimmers Brand
LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON

Model
MACL-153M-WH CTCL-153PDH-WH DVCL-153PR-WH DVCL-153P-WH MACL-153MH-WH RRD-6CL SLV-600P TGCL-153PH

Sccaonmfpoarttihbleefduillmmer list!

Specifications
Voltage Wattage Wattage Equivalency Beam Angle Weight Housing Material Dimmable

120V 13W 120W 90° 0.45lbs Polycarbonate Yes

Average Lifetime Lumens Moisture Rating CRI Usage IC Rated Warranty

50,000 hrs 965LM Damp 80+ Indoor Yes 7 Years

5

Common Troubleshooting

Feeling in the dark about an issue with your product? No

If you still need some assistance, please feel free to

worries! Our troubleshooting section is here to shed some light contact us with any questions. Our team of lighting experts

and provide you with easy-to-follow solutions for any problem. are happy to help brighten your day.

Installation Light isn't turning on.

Double check if fixture is properly connected and circuit breaker hasn't been tripped.

Light unexpectedly fails. Dimming
Light not dimming to lowest setting.
Light not dimming smoothly.
Light not compatible with dimmer switch. Flickering
Light is flickering when turning on. Light flickering with other lights on the same circuit. Light flickering when turned on. Light flickering when dimmed. Buzzing Fixture buzzing with power outages.
Fixture buzzing with appliances or electronic devices.
Fixture buzzing when dimmed.

For further assistance, contact our customer support.
Ensure minimum dimmer load requirement is met.
Verify dimmer compatibility with fixture. Check light-dimmer compatibility. Consider purchasing compatible switch if necessary. Check that fixture wiring connections are secure. Check that the lights on the same circuit are not overloading the circuit. Verify fixture compatibility. Verify dimmer switch compatibility.
Verify light is connected to surge protector securely. Look for nearby interferences that can cause buzzing. Such as televisions, radios, computers, etc. Verify dimmer switch compatibility.

6

Light Distribution Angle

Not No

awloirgrhietisn, ygonuercda?n

skip

this

page

AVERAGE BEAM ANGLE (50%): 101.6 DEG C0/180 101.3° C90/270 101.8°
UNIT:cd Luminous Intensity Distribution 1

Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles:
A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting.

An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more.
It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated.

7

Customer Support

Warranty Policy
This product is covered by our industry leading 7 year warranty.
It gets even better - scan the QR code for 2 extra years of protection!

Secxatnramyeeafrosr! two

30 Day Return Policy

At Sunco, we value our customers and stand by the quality and performance of our products.

If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.

Customer Service
Our Los Angeles team of lighting experts is here to assist you with all your needs! Contact us at:

Email: support@sunco.com

Call or Text: (844) 334-9938

8

Lighting made better.

support@sunco.com

(844) 334-9938

REV1.1

AMERICAN COMPANY



References

Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)