Instruction Manual for TFC GROUP models including: OP-SBWF01 WiFi Socket Box Time Switch, OP-SBWF01, WiFi Socket Box Time Switch, Socket Box Time Switch, Box Time Switch, Time Switch, Switch
OP-SBWF01 Wi-Fi Socket Box Timer – TFC Group – Tower
File Info : application/pdf, 2 Pages, 161.69KB
DocumentDocument3,Backplate wiring: Example (Volt Free) 123 45 230V AC Supply To appliance Power / Set-up Button Wiring diagram (Volt Free) M~ E 1 2 3 4 5 L N 230V AC mains supply Live in to appliance Live out to appliance OP-SBWF01 Installation Instructions WiFi Signal Indicator Specification COMMS: WiFi ISM 2.4GHz; WLAN 802.11 b/g/n PROG CAPACITY: 15 On/Off Programmes Total COUNTDOWN: Countdown On or Off RANDOM: Output switches randomly during set period. REPEAT: A repeating cycle that can be set between the ON and OFF times. DIMENSIONS: 92 x 92 x 60 WEIGHT: 170g POWER: 1vA @ 230V 50Hz RESISTIVE LOAD: 16 Amperes INDUCTIVE LOAD: 4 Amperes (cos Ø 0.6) TEMP RATING: -10T55 ACCURACY: Internet Synchronised MIN. SWITCHING: 1 Minute OVERRIDE: On / Timed / Off Class II control / Protection class IP20 Complies with European Norm EN 61058-1:2002+A2:2008 Switches for Appliances: General Requirements,and European Directives: LVD; EMC; RoHS; RED www.tfc-group.co.uk TFC Group Tonbridge TN9 1TB WiFi Socket Box Time Switch For general purpose use Installation instructions OP-SBWF01 WiFI Socket Box Timer Min switching 1 Minute 1. Installation procedure 2. Backplate wiring Example (230V AC 50-60Hz) 3. Backplate wiring Example (Volt Free) 4. Specification OP-SBWF01 Installation Instructions Please read the instructions fully before attempting installation. IMPORTANT Installation must be carried out in accordance with the current edition of the I.E.E. Wiring Regulations. It is recommended that installation is undertaken only by a qualified electrician. Timer must not be mounted on a flammable surface. Ensure that the timer does not come into contact with any combustible materials such as towels or bedding. Ensure at least a 300 mm air space is allowed around the timer. The timer should not be mounted on an unearthed metal or metallised surface. screws, in accordance with circuit diagram label beneath terminals. 2. Backplate wiring: Example (230V AC 50-60Hz) If the timer is to be connected to an appliance that is required to be earthed the supply earthing conductor and the appliance earthing conductor should be terminated together in the earth terminal provided within the timer. 1. Installation procedure Note: Do not connect unprepared stranded wires. Use ferrules supplied to crimp stranded wire terminations. 3. Fix backplate to socket box. 4. Connect wiring in accordance with wiring diagram. 123 45 2 4 230V AC Supply To appliance 1. Switch the supply off at the mains. Means of disconnection from the supply having at least 3 mm contact separation in all poles must be incorporated in the fixed wiring mains supply. 5. Fit cover over module and reassemble to backplate. Ensuring fixed blue wires are stowed neatly without being trapped. 6. Re-fit and tighten two screws. Wiring diagram (230V AC 50-60Hz) ~M 2. Unscrew the two screws located top right and bottom left of front module cover; remove cover and gently pull module from backplate. Do not put undue stress on, `or' interfere with fixed connecting wires. Bare wires back for 6 mm (1/4 inch) maximum; insert into terminals and secure with the 7. Switch on mains. E 1 2 3 4 5 N L mains supply N L to appliance OP-SBWF01 Installation Instructions