OP-SBWF01 installer Instructions

mie

Download

OP-SBWF01 Wi-Fi Socket Box Timer – TFC Group – Tower


File Info : application/pdf, 2 Pages, 161.69KB

PDF preview unavailable. Download the PDF instead.

OP-SBWF01 installer Instructions-2
3,Backplate wiring: Example (Volt Free)

123 45

230V AC Supply

To appliance

Power / Set-up Button

Wiring diagram (Volt Free) M~

E

1

2

3

4

5

L

N

230V AC

mains supply

Live in to appliance

Live out to appliance

OP-SBWF01 Installation Instructions

WiFi Signal Indicator

Specification

COMMS: WiFi ISM 2.4GHz; WLAN 802.11 b/g/n

PROG CAPACITY: 15 On/Off Programmes Total

COUNTDOWN: Countdown On or Off

RANDOM:

Output switches randomly during set period.

REPEAT:

A repeating cycle that can be set between the ON and OFF times.

DIMENSIONS: 92 x 92 x 60 WEIGHT: 170g POWER: 1vA @ 230V 50Hz
RESISTIVE LOAD: 16 Amperes INDUCTIVE LOAD: 4 Amperes (cos Ø 0.6)
TEMP RATING: -10T55 ACCURACY: Internet Synchronised
MIN. SWITCHING: 1 Minute OVERRIDE: On / Timed / Off

Class II control / Protection class IP20

Complies with European Norm

EN 61058-1:2002+A2:2008 Switches for Appliances: General Requirements,and European Directives:

LVD; EMC; RoHS; RED

www.tfc-group.co.uk TFC Group Tonbridge TN9 1TB

WiFi Socket Box Time Switch
For general purpose use
Installation instructions
OP-SBWF01 WiFI Socket Box Timer Min switching 1 Minute
1. Installation procedure 2. Backplate wiring Example (230V AC 50-60Hz) 3. Backplate wiring Example (Volt Free) 4. Specification
OP-SBWF01 Installation Instructions

Please read the instructions fully before attempting installation.
IMPORTANT
Installation must be carried out in accordance with the current edition of
the I.E.E. Wiring Regulations. It is recommended that installation is
undertaken only by a qualified electrician.
 Timer must not be mounted on a flammable surface.
 Ensure that the timer does not come into contact with any combustible materials such as towels or bedding.
 Ensure at least a 300 mm air space is allowed around the timer.

 The timer should not be mounted on an unearthed metal or metallised surface.

screws, in accordance with circuit diagram label beneath terminals.

2. Backplate wiring: Example (230V AC 50-60Hz)

 If the timer is to be connected to an appliance that is required to be earthed the supply earthing conductor and the appliance earthing conductor should be terminated together in the earth terminal provided within the timer.
1. Installation procedure

Note: Do not connect unprepared stranded wires. Use ferrules supplied to crimp stranded wire terminations.
3. Fix backplate to socket box.
4. Connect wiring in accordance with wiring diagram.

123 45

2

4

230V AC Supply

To appliance

1. Switch the supply off at the mains. Means of disconnection from the supply having at least 3 mm contact separation in all poles must be incorporated in the fixed wiring mains supply.

5. Fit cover over module and reassemble to backplate. Ensuring fixed blue wires are stowed neatly without being trapped.
6. Re-fit and tighten two screws.

Wiring diagram (230V AC 50-60Hz)

~M

2. Unscrew the two screws located top right and bottom left of front module cover; remove cover and gently pull module from backplate. Do not put undue stress on, `or' interfere with fixed connecting wires. Bare wires back for 6 mm (1/4 inch) maximum; insert into terminals and secure with the

7. Switch on mains.

E

1

2

3

4

5

N

L

mains supply

N

L

to appliance

OP-SBWF01 Installation Instructions

