Mitsubishi MLZ-KX09NL & SUZ-AA09NL
9,000 BTU/H Ceiling-Mounted Indoor Unit
9,000 BTU/H Heat Pump Outdoor Unit
Indoor Unit Model: MLZ-KX09NL
Outdoor Unit Model: SUZ-AA09NL
Indoor Unit Features
- Adjustable fan speeds and vane directions.
- Auto Vane Control: Outlet vanes can be moved left and right, and up and down using the remote controller. This improved air flow control feature solves the problem of drafts.
- Built-in condensate lift mechanism (19.6"): Reduces the need for an additional pump to remove condensate water.
- Econo Cool: Temporarily and automatically adjusts airflow based on heat exchanger temperature. The set temperature is increased slightly, saving energy while maintaining comfort.
- Fits between 16" joists spacing.
- Multiple control options: Hand-held Remote Controller (provided), comfort app, third-party interfaces, and both wired and wireless controllers.
- Serviceable from the bottom (electrical and flare connections).
- Stylish, square design panel.
- Washable antibacterial and deodorizing filter.
- Weekly Timer Function: Set desired temperatures and operation ON/OFF times to match lifestyle patterns. Reduces wasted energy consumption by preventing forgetting to turn off the unit and eliminating temperature setting adjustments.
- Wi-Fi enabled units pair with the Comfort app for complete control over temperature, fan speeds, modes, schedules, and more.
Outdoor Unit Features
- Blue Fin Coating: Anti-corrosion treatment applied to aluminum fins of the heat exchanger to protect against corrosion from salt, sulfur, and other airborne contaminants, especially in coastal and industrial areas.
- High-performance grooved piping: Increases heat exchange efficiency.
- Hot-Start Technology: Ensures the fan only activates once the heat exchanger is warm, preventing cold air blasts during start-up.
- INVERTER-driven compressor: Generates precise capacity needed to maintain a temperature set point.
- Joint Lap DC Motor: Leads to high efficiency and reliability.
- Outdoor unit directed power: The outdoor unit powers the indoor unit; the system automatically restarts when power returns after an outage.
- Pulse Amplitude Modulation technology: Enhances energy efficiency by adjusting power supply to optimize compressor performance, ensuring precise capacity control and reduced energy consumption.
- Quiet operation: Units are as quiet as a typical conversation; most indoor units are whisper quiet.
- Single-zone: One outdoor unit connects to one indoor unit to control comfort in a single space.
Specifications
Indoor Unit Specifications
Category | Item | Value | Unit | Notes |
---|---|---|---|---|
Cooling at 95°F | Maximum Capacity | 9,000 | Btu/h | |
Rated Capacity | 9,000 | Btu/h | ||
Minimum Capacity | 2,200 | Btu/h | ||
Maximum Power Input | 760 | W | ||
Rated Power Input | 760 | W | ||
Moisture Removal | 1.6 | Pints/h | ||
Sensible Heat Factor | 0.8 | - | ||
Power Factor [208V/230V] | 91/91 | % | ||
Heating at 47°F | Maximum Capacity | 13,000 | Btu/h | |
Rated Capacity | 12,000 | Btu/h | ||
Minimum Capacity | 5,000 | Btu/h | ||
Maximum Power Input | 1,050 | W | ||
Rated Power Input | 910 | W | ||
Power Factor [208V/230V] | 95/95 | % | ||
Heating at 17°F | Maximum Capacity | 7,800 | Btu/h | |
Rated Capacity | 7,800 | Btu/h | ||
Maximum Power Input | 740 | W | ||
Rated Power Input | 740 | W | ||
Heating at 5°F | Maximum Capacity | 6,300 | Btu/h | |
Maximum Power Input | 615 | W | ||
Heating at -4°F | Maximum Capacity | 5,300 | Btu/h | |
Efficiency | SEER2 | 20.9 | - | |
EER2¹ | 11.8 | - | ||
HSPF2 [IV] | 12.2 | - | ||
COP at 47°F² | 3.8 | - | ||
COP at 17°F at Maximum Capacity³ | 3 | - | ||
COP at 5°F at Maximum Capacity⁴ | 3 | - | ||
COP at -4°F at Maximum Capacity⁵ | 2.46 | - | ||
ENERGY STAR® Certified | Yes | - | ||
Electrical | Voltage, Phase, Frequency | 208/230, 1, 60 | V AC / V AC, Hz | |
Guaranteed Voltage Range | 198 - 253 | V AC | ||
Voltage: Indoor - Outdoor, S1-S2 | 208/230 | V AC | ||
Voltage: Indoor - Outdoor, S2-S3 | 12-24 | V DC | ||
Short-circuit Current Rating [SCCR] | 5 | kA | ||
Recommended Fuse/Breaker Size (Outdoor) | 15 | A | ||
Recommended Wire Size [Indoor - Outdoor] | 14 | AWG | ||
MCA | 1 | A | ||
Indoor Unit | Fan Motor Output | 30 | W | |
Airflow Rate at Cooling, Dry | 201, 254, 282, 311 | CFM | ||
Airflow Rate at Heating, Dry | 212, 247, 290, 325 | CFM | ||
Sound Pressure Level [Cooling] | 27, 31, 34, 38 | dB (A) | ||
Sound Pressure Level [Heating] | 26, 29, 34, 37 | dB (A) | ||
Drain Pipe Size O.D. | 1-1/16 [26] | inch [mm] | ||
Unit Dimensions (W x D x H) | 43-3/8 x 14-3/16 x 7-5/16 [1,102 x 360 x 185] | inch x inch x inch [mm x mm x mm] | ||
Package Dimensions (W x D x H) | 46-3/8 x 11-3/16 x 15-3/4 [1,177 x 284 x 400] | inch x inch x inch [mm x mm x mm] | ||
Unit Weight | 34 [15.50] | lbs [kg] | ||
Package Weight | 42 [19] | lbs [kg] | ||
Fan Motor Type | DC Motor | - |
Outdoor Unit Specifications
Category | Item | Value | Unit | Notes |
---|---|---|---|---|
MCA | 13 | A | ||
MOCP | 22 | A | ||
Fan Motor Output | 55 | W | ||
Airflow Rate Cooling | 1,229 | CFM | ||
Airflow Rate Heating | 1,172 | CFM | ||
Defrost Method | Reverse Cycle | - | ||
Coating on Heat Exchanger (Bluefin, Sea Coast) | Yes, Yes | - | ||
Outdoor Unit | Sound Pressure Level, Cooling¹ | 48 | dB (A) | |
Sound Pressure Level, Heating² | 50 | dB (A) | ||
Compressor Type | Twin Rotary | - | ||
Compressor Model | SRB092FQFMC | - | ||
Compressor Oil [Type // Charge] | RM68EH // 11.83 | Type // oz | ||
External Finish Color | Munsell No.3Y 7.8/1.1 | - | ||
Base Pan Heater | Optional | - | ||
Unit Dimensions (W x D x H) | 31-1/2 x 11-1/4 x 21-5/8 [800 x 285 x 550] | inch x inch x inch [mm x mm x mm] | ||
Package Dimensions (W x D x H) | 37-1/16 x 15 x 24-13/16 [940 x 380 x 630] | inch x inch x inch [mm x mm x mm] | ||
Unit Weight | 81 [37] | lbs [kg] | ||
Package Weight | 88.18 [40] | lbs [kg] | ||
ODU Operating Temp. Range | Cooling Intake Maximum Air Temp [Maximum / Minimum*] | 115 / 14 | °FDB | |
Cooling Thermal Lock-out / Re-start Temperatures** | -1 / 3 | °FDB | ||
Heating Air Temp [Maximum / Minimum] | 75, 65 / -4, -5 | °FDB, °FWB / °FDB, °FWB | ||
Heating Thermal Lock-out / Re-start Temperatures** | -14 / -4 | °FDB | ||
Piping | Type | R454B | - | |
Pre-Charged Refrigerant Amount | 2 | lbs | ||
Maximum Pre-Charged Piping Length | 65 [7.60] | ft [m] | ||
Additional Refrigerant Charge Per Additional Piping Length | 0 | oz/ft | ||
Gas Pipe Size O.D. [Flared] | 3/8 [9.52] | inch [mm] | ||
Liquid Pipe Size O.D. [Flared] | 1/4 [6.35] | inch [mm] | ||
Maximum Piping Length | 65 [19.80] | ft [m] | ||
Maximum Height Difference | 40 [12.10] | ft [m] | ||
Maximum Number of Bends | 10 | - |
Accessories
Indoor Unit Accessories
- Disconnect Switch: TAZ-MS303 (Black), TAZ-MS303W (White)
- Condensate Pumps: Blue Diamond Advanced Mini (X87-721), MaxiBlue Advanced Mini (X87-711), MegaBlue Advanced (X87-835), MicroBlue Mini (X86-003). Sensor Extension Cable (C13-103). Refco (COMBI), Sauermann (S130-230).
- Control Interface: Airzone Wired Blueface (AZZBSBLUEZEROCN/CB), Wireless Lite (AZZBSLITERN/B), Wireless Think (AZZBSTHINKRN/B). IT Extender (PAC-WHS01IE-E), kumo station (PAC-WHS01HC-E). M-Net I/O (MAC-334IF-E), Procon BACnet/Modbus (PAC-UKPRC001-CN-1), Thermostat Interface (PAC-US445CN-1), Wireless Adapter (PAC-USWHS002-WF-2).
- Lineset Insulation: MLS143812T-15, MLS143812T-30, MLS143812T-50, MLS143812T-65.
- Remote Sensor: M21EAA307, PAC-USWHS003-TH-1.
- Wired Remote Controller: Deluxe MA (PAR-42MAAUB), Simple Direct (PAC-SDW01RC-1), Simple MA (PAC-YT53CRAU-J), Touch MA (PAR-CT01MAU-SB).
- Drain Hose: DRX-16.
- Filter: Anti-allergy Enzyme Filter (MAC-408FT-E), Microparticle Filter (MAC-EMF515FT-E).
- Grille: MLP-449WU.
- Power Supplies and Auxiliary Components: Backup Heat Relay Kit (CN24RELAY-KIT-CM3).
- Wireless Remote Controller: Lockdown Bracket (RCMKP1CB), RedLINK Wireless Remote Controller (MHK2).
Outdoor Unit Accessories
- Control/Service Tool: M- & P-Series Maintenance Tool Cable Set (M21EC0397), Maintenance Tool Interface (PAC-USCMS-MN-1).
- Air Outlet Guide: MAC-881SG-E.
- Optional Defrost Heater: MAC-640BH-U1.
- Stand: 18 Single Fan Stand (QSMS1801M), 24 Single Fan Stand (QSMS2401M).
- Condenser Wall Bracket: QSWB2000M-1 (Standard), QSWBSS (Stainless Steel).
- Outdoor Unit Mounting Base: DSD-400P (Plastic Pair), QSMS1201M (12 High Stand).
- Mini-Split Wire: 14 Gauge 4 wire Armored (SW144-250 / SW144-50), 14 Gauge 4 wire (S144-250 / S144-50).
- Centralized Drain Pan: PAC-SG63DP-E.
- Drain Socket: MAC-871DS.
- Snow/Rain Diverter: SRD-1.
- Hail Guards: HG-B4.
- Mounting Pad: ULTRILITE1.
- Muffler: MAC-001MF-E.
Dimensions
Indoor Unit Dimensions
Indoor Unit Outline Drawing: Provides top, front, and right-side views with dimensions for overall unit size, suspension bolt pitch (e.g., 41-3/8 inches), electrical box location, and pipe/drain connections. The top view indicates the ceiling opening hole and suspension bolt pitch are consistent with the grille.
Grille Outline Drawing: Details the grille dimensions, flap protrusion, and reception window.
Indoor Unit Detail View: Shows top and front views illustrating internal components, air outlet/inlet areas, drain pan, and pipe connection details, including gas and liquid pipe sizes and drain hose connection. The diagram specifies rigid PVC pipe O.D. of 1 inch (26mm) for the drain.
Outdoor Unit Dimensions
Outdoor Unit Dimensions: Presents top, front, and side views of the outdoor unit with key dimensions. It includes details on refrigerant pipe joints (gas and liquid pipe sizes) and drain hole locations. The diagram specifies refrigerant pipe sizes: 1/4 inch for liquid and 3/8 inch for gas (AA09/12) or 1/2 inch (AA15).
Required Space Diagram: Illustrates the necessary clearances around the outdoor unit for proper ventilation. It specifies a minimum of 4 inches (100 mm) for the front and sides, and 8 inches (200 mm) for the rear when two sides are clear. It also notes a minimum of 14 inches (350 mm) for the front.