Instruction Manual for TeeJet TECHNOLOGIES models including: 116950, 116961, 116961-7, 116950 Nozzle Body Shutoff Valves, 116950, Nozzle Body Shutoff Valves, Body Shutoff Valves, Shutoff Valves, Valves

Binder1

Moore, Alex

PDF preview unavailable. Download the PDF instead.

MI116950

116950 e-ChemSaver® ES Valve Maintenance Instruction
 Ver. 1
The 116950 e-ChemSaver® ES Valve is a solenoid-actuated shutoff compatible with a wide range of TeeJet® nozzle bodies equipped with a diaphragm check valve. It can be used for end-of-boom nozzles as well as individual tip shutoff control.
The valve is normally closed and opens when the solenoid is energized. The 116950 has a 2-Pin Superseal 1.5 connector molded into the body for a clean, weather-tight electrical connection.
Application Note(s): Rinse system with clean water after each application. 80 mesh strainer screen or finer is recommended with all e-ChemSaver® ES Valve applications.
General Disassembly and Reassembly
 Unscrew the valve assembly from the nozzle body by rotating the interface cap/locking ring (Item  counterclockwise until the assembly separates.
 Remove FKM gasket (1).
 Loosen and remove the nylon interface cap/locking ring (2) from the coil assembly (3-7) by compressing the interface cap/locking ring against the coil assembly and turning counterclockwise until separated.
All repairable parts should be accessible at this point. The installation spring (3), plunger subassembly (), stainless steel spring (), and o-ring (6) can be replaced without further disassembly.
 During reassembly, please ensure that the o-ring (6) is pressed down to the outside base of the threads on the coil assembly(7/7A) to avoid damaging the o-ring when reassembling. Then, place the stainless steel spring (), and plunger sub-assembly () in the coil assembly (7/7A).
Note: The conical shaped stainless steel spring () should be oriented with the wider end restingin the groove of the coil assembly (7/7A) and the narrower end facing outward (visible). Then,place the plunger sub-assembly () with the black insert facing outward (visible) and insert it intothe narrower end of the spring () when placed in the coil assembly (7/7A). Then place the installation spring (3) onto base of coil assembly so that the three tabs lay flat on the base of the coil assembly.
 Tighten the nylon interface cap/locking ring (2) from the coil assembly (3-7) by compressing the interface cap/locking ring against the coil assembly and turning clockwise until tight. Then place gasket (1) into interface cap and locking ring sub assembly.
Torque Specifications: Tighten interface cap/locking ring (2) & coil assembly (3-7) to 12 in-lbs (1.36 N-m)
 Recommended: At the time of installation, spray a sufficient quantity of corrosion prevention (CorrosionX®, CorrosionX® Heavy Duty, or CorrosionX® Aviation) compound into the connector to wet the terminals prior to plugging the connector in.
**Item Numbers (1-10) correspond to Parts List: PL115880

1

2, 2A

3

4

5

6

7, 7A

*TABS OF WAVE SPRING (ITEM 3) FACE COIL

ITEM

PART NUMBER

DESCRIPTION

1 CP116247-VI-10X

GASKET, FKM (10-PACK)

2 116961

INTERFACE CAP & LOCKING RING SUB-ASSEMBLY

2A 116961-7

INTERFACE CAP & LOCKING RING SUB-ASSEMBLY (ARAG BODIES)

3 CP116963-CE

INSTALLATION SPRING, CELCON-BLACK

4 116956

PLUNGER SUB-ASSEMBLY

5 CP116960-SS

SPRING, STAINLESS STEEL

6 CP7717-M17X1.5-VI-10X O-RING, FKM (10-PACK)

7 116951-12

COIL ASSEMBLY, 12V

7A 116951-24

COIL ASSEMBLY, 24V

SPARE KITS AB116950-1-12-KIT, 12V COIL KIT (INCLUDES ITEMS 6 AND 7) AB116950-1-24-KIT, 24V COIL KIT (INCLUDES ITEMS 6 AND 7A) AB116950-2-KIT, SPARE PARTS KIT (INCLUDES ITEMS 4 AND 5) AB116950-3-KIT, SPARE PARTS KIT (INCLUDES ITEMS 2 AND 3) AB116950-4-KIT, SPARE PARTS KIT (INCLUDES ITEMS 2, 3, 4, 5, AND 6)

DESCRIPTION: TEEJET_ e-CHEMSAVER ES SOLENOID OPERATED ELECTRIC SHUTOFF VALVE
c Spraying Systems Co.

REVISION NO.
1
REFERENCE:

Parts List No.
PL116950

9/1/21 SHEET: 1 OF 1

DWG SIZE:

A


Acrobat Distiller 24.0 (Windows)