LAMLAMCK LED Flood Light with Motion Sensor
Manufacturer: Shenzhen Jintenger Shangmao Youxiangongsi
Address: shenzhenshifutianqushatoujiedaotiananshequtairanwulu 4haotianzhandashasancengF2.6-3D323A
Contact: +8613435771837 | jintengeramz@163.com
EU Representative: O RIER SL, CALLE RIO TORMES NUM. 1, PLANTA 1, DERECHA, OFICINA 3, Fuenlabrada, Madrid, 28947 Spain
Warnings/Notice
- This lamp is a Class 1 luminaire and must be properly grounded; grounding is mandatory.
- Turn off the power before installation or maintenance. Installation should be performed by a qualified electrician.
- Select the power cable according to actual power requirements and use separate phases for power distribution.
- The lamp should be installed in locations out of reach to avoid accidental contact.
- Do not touch or install the lamp when it is in contact with water. Avoid touching the lamp during use to prevent burns.
- To ensure proper operation and prevent water stains, the sensor surface of the motion detector must face downward.
- Do not stare directly at the illuminated light for prolonged periods.
- The lamp is designed for rainproof and moisture-proof use only and should not be submerged in water, as this may cause electrical leakage.
- The light source and external cables of this lamp are non-replaceable; when the light source reaches the end of its life or the cable is damaged, the entire lamp should be replaced.
Product Components and Structure Diagram
This diagram illustrates the physical appearance of the LAMLAMCK LED floodlight, showing its housing, the integrated motion sensor, and mounting bracket. It indicates typical sensor detection ranges (2-5 meters, 8-10 meters) and the detection angle (180°).
Product Specifications
Model | Power | Luminous Flux | Input Voltage | Cable Length | Installation Height | Lighting Range | Product Dimensions | Product Weight |
---|---|---|---|---|---|---|---|---|
JIN-C15-GY-50W | 50W | 5000LM | AC 220V-240V | 50cm | 3-5m | 30-50m² | 17*19.5*4 | 0.52 |
JIN-C15-GY-100W | 100W | 10000LM | AC 220V-240V | 50cm | 6-8m | 50-100m² | 23.2*22*4.5 | 0.83 |
Colour Temperature: 6500K
Frequency: 50Hz
Material: Aluminum + Tempered Glass + Iron
Waterproof Rating: IP66
Operating Temperature: -20~40℃
LED Type: SMD2835 LED Chips
Installation Instructions
Wiring:
- Blue Cable: Neutral Wire
- Yellow-Green Cable: Ground Wire ⏚
- Brown-Red Cable: Live Wire
Steps:
- Determine mounting hole distance and drill holes.
- Connect the lamp's cables to the power supply (L, N, and Ground).
- Turn on the power supply.
- Adjust sensor angles as needed.
- Tighten the screws to secure the lamp.
Diagrams show the wiring connections (L, N, Ground symbol) and the physical mounting process.
Sensor Installation
Diagrams illustrate the sensor mounting and adjustment capabilities, showing detection ranges of 2-5 meters and 8-10 meters, with a detection angle of 180° and a wider 240° option.
Sensor Function Description
LUX Setting
Controls the ambient light level at which the sensor activates:
- When the knob points to ☀️ (Day/Night): The sensor triggers the light during both day and night.
- When the knob points to ? (Night): The sensor triggers the light only at night and will not function during the day.
SENS Setting
Adjusts the motion detection sensitivity:
- When the knob points to -: Minimum sensitivity.
- When the knob points to +: Maximum sensitivity.
TIME Setting
Determines the duration the light stays on after motion is detected:
- When the knob points to _: Illumination time is 5 seconds.
- When the knob points to +: Illumination time is 12 minutes.
Demonstration Setting: LUX knob set to ☀️, SENS knob set to +, TIME knob set to +.
Manual Mode
Manual mode is suitable for customers who require the light to operate continuously for extended periods.
Activating Manual Mode
- Turn the power off and on twice within 2 seconds (off, on, off, on).
- After the light flashes, manual mode is activated, and the light will stay on continuously.
- The product will automatically deactivate this mode and return to sensor mode after 5 hours and 30 minutes of continuous operation.
Exiting Manual Mode Early
- Power down the light for 10-30 seconds and then restart it.
- Alternatively, perform the power off and on sequence twice consecutively.
- The product will revert to sensor mode.
Frequently Asked Questions (FAQ)
- What should I do if the floodlight fails to illuminate?
This product requires professional installation by an electrician to ensure proper installation and cable connections.
- Is the sensor a twilight sensor?
No, this product uses a motion sensor, not a twilight sensor.
- What should I do if the floodlight cannot be completely turned off and remains faintly lit for a long time?
Please switch the positive and negative poles of the cable to ensure that the live wire of the fixture is completely disconnected from the mains.
- Does the floodlight come with a plug?
No, this product does not include a plug.
- What should I do if the sensor sensitivity is poor?
Ensure that the operating environment temperature is not too high and that there are no obstructions blocking the sensor.
- What should I do if there's a problem with the lamp I received?
If you receive a defective or malfunctioning product, please contact our customer service. Our after-sales team will promptly assist you in resolving any product issues.