Feature | Cooling | Heating |
---|---|---|
Capacity (BTU/h) | 36,000 (5,700~36,400) | 38,000 (9,500~44,000) |
SEER/SEER2 | 17.2/17.2 | N/A |
EER/EER2 | 11.7/11.7 | N/A |
COP | N/A | 3.39 |
HSPF4/HSPF2-4 | N/A | 9.5 |
HSPFS/HSPF2-5 | N/A | 8 |
Operational Temperature Range
Environment | Mode | Temperature Range (°F) |
---|---|---|
Indoor | Cooling | 60~90 |
Heating | 32~86 | |
Outdoor | Cooling | -22~122 |
Heating | -22~75 |
Warranty Information
This warranty should be registered on the Cooper & Hunter website (www.cooperandhunter.us) within 60 days of installation. The warranty is only valid when installed by a Licensed HVAC Technician. A warranty period of Seven (7) years on the compressor applies to the original registered end-user. A warranty period of Five (5) years on all parts applies to the original registered end-user. Warranty applies only to products remaining in their original installation location.
Indoor Unit Features
- Auto restart function
- Quiet operation
- Multiple fan speeds
- Auxiliary heater
- Turbo mode
- Adjustable static pressure
- Multi position
- Anti-cold air function
- Fast cool/heat function
- Aluminium coil
- WIFI ready
- Intelligent air flow
- Refrigerant leak detect
- Sleep mode
- Gold fin
Outdoor Unit Features
- Inverter technology
- Variable speed (fan motor & compressor)
- Heating operation in temperatures down to -13 °F
- 3-Minute restart delay
- Self-diagnosis
- Drain pan heater and compressor heating belt
- Auto restart function
- Defrost
- High-efficiency pipes
- High-frequency racer technology
- Intelligent dusting switch
- Gold fin
Included Accessories
- Wireless remote
- Wall thermostat
Indoor Unit Specifications
Specification | Value |
---|---|
Indoor Model | CH-RS36LCAHU |
Power supply | 208-230V, 1Ph, 60Hz |
Voltage range | 187-253 V |
Connection wiring | AWG 20-2 |
Cooling Capacity | 36,000 BTU/h (5,700~36,400) |
Cooling Input | 3,080 W (660~3,800) |
Cooling Rated current | 13.4 A (4.8~17) |
Cooling EER/EER2 | 11.7 / 11.7 Btu/w |
Cooling SEER/SEER2 | 17.2 / 17.2 Btu/w |
Heating Capacity | 38,000 BTU/h (9,500~44,000) |
Heating Input | 3,289 kW (810~4,160) |
Heating Rated current | 14.3 A (4.4~18.5) |
Heating COP | 3.39 W/W |
Heating HSPF4/HSPF2-4 | 9.5 Btu/w |
Heating HSPF5/HSPF2-5 | 8 Btu/w |
Min. circuit ampacity | 6 A |
Max. fuse | 15 A |
Indoor fan motor Qty | 1 |
Indoor fan motor Output | 375 W |
Indoor fan motor RLA | 4.5 A |
Indoor air flow (Turbo/Hi/Med/Lo) (No duct) | 1,189/1,083/971.2/865.2 CFM |
ESP Range | 0-0.8 In.wg. |
Indoor noise level (Hi/Med/Lo) | 47/42/30.5 dB(A) |
Dehumidification | 7.59 pnt/h |
Indoor unit Dimensions (WxDxH) | 21.02 x 21.02 x 49.02 in |
Indoor unit Packing (WxDxH) | 24.41 x 26.57 x52.56 in |
Indoor unit Net/Gross weight | 127.87/152.78 lbs |
Drainage water pipe diameter | 3/4" in |
Refrigerant piping Liquid side/Gas side | 3/8"/3/4" in |
Controller | wire controller + remote controller available |
Room temperature Cooling | 60~90 °F |
Room temperature Heating | 32~86 °F |
Outdoor Unit Specifications
Specification | Value |
---|---|
Outdoor Model | CH-RHP36LCU-230VO |
Power supply | 187-253 V, 1Ph, 60Hz |
Min. circuit ampacity | 38 A |
Max. fuse | 40 A |
Compressor Model | EKPQ420D1UMUA |
Compressor Type | TWIN-ROTARY |
Compressor Brand | GMCC |
Capacity | 40,940 Btu/h |
Input | 3,265 W |
Refrigerant oil | VG75 49.4 OZ |
Compressor Qty | 1 |
Outdoor fan motor Output | 250 W |
Outdoor fan motor RLA | 2.1 A |
Outdoor fan motor Speed | 750/650/550 r/min |
Outdoor air flow (Max) | 3,001.9 CFM |
Outdoor noise level (Max) | 65.5 dB(A) |
Outdoor unit Dimensions (WxDxH) | 38.58 x 16.34 x 38.39 in |
Outdoor unit Packing (WxDxH) | 45.08 x 19.68 x 42.52 in |
Outdoor unit Net/Gross weight | 206.57/237.44 lbs |
Refrigerant Type/Quantity | R454B / 126.99 OZ |
Refrigerant precharge | 25 ft |
Additional charge for each ft | 0.32 OZ |
Refrigerant piping Liquid side/Gas side | 3/8"/3/4" in |
Refrigerant piping Max. pipe length | 246 ft |
Refrigerant piping Max. difference in level | 98.4 ft |
Ambient temperature Cooling | -22 ~ 122 °F |
Ambient temperature Heating | -22~75 °F |
Diagram Descriptions
Indoor Unit Connection Diagram (Page 4): Depicts the indoor unit with various connection points and dimensions. Key elements include: Supply air opening, Line voltage inlets (top and right side), Low voltage inlets (top and left side), knock holes for wiring (for electricity and communication wires, noting they should not share the same hole), control box, display window, piping plate, condensate drains (primary for gravity drain, secondary for emergency draining), filter access, and filter cover. The piping plate shows connections for suction line, liquid line, and drain pipes.
Outdoor Unit Dimensions Diagram (Page 5): Illustrates the external dimensions of the outdoor unit from side, front, and top views, providing measurements in inches and millimeters for overall height, width, and depth.