User Manual for baudcom models including: 64 Port High power amplifier, 64 Port, High power amplifier
2021-11-02 — Website: www.baudcom.com.cn. Tel: 86 21 37709251. Email: info@baudcom.com.cn. Catalog. Using Safety Precautions.
SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Website: www.baudcom.com.cn Tel: 86 21 37709251 Email: info@baudcom.com.cn Application
File Info : application/pdf, 16 Pages, 831.59KB
DocumentDocumentSHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Operating Manual 64 Port High power amplifier Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Catalog Using Safety Precautions........................................................................................................................................................... 1 Application ................................................................................................................................................................................ 2 Feature .................................................................................................................................................................................. 2 Description:........................................................................................................................................................................... 2 Block Diagram ...................................................................................................................................................................... 2 Optical characteristics .......................................................................................................................................................... 4 Environmental characteristics .............................................................................................................................................. 4 Electrical Characteristics...................................................................................................................................................... 4 Starting up................................................................................................................................................................................. 5 Equipment Powered Instructions ......................................................................................................................................... 5 LED/ Key Description........................................................................................................................................................... 5 Display Menu Description..................................................................................................................................................... 5 Indicator................................................................................................................................................................................ 6 Interface ................................................................................................................................................................................ 7 Web............................................................................................................................................................................................ 8 Login ..................................................................................................................................................................................... 8 Device Infomation ................................................................................................................................................................. 9 Network Config..................................................................................................................................................................... 9 User Management ............................................................................................................................................................... 10 SNMP Config ...................................................................................................................................................................... 12 SNMP ...................................................................................................................................................................................... 13 Laser Safety Information ........................................................................................................................................................ 13 Order Information .................................................................................................................................................................. 13 Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Using Safety Precautions Before installing and using this product, please read the following carefully. The Company does not assume any responsibility for any loss due to security breaches caused. Lasers and erbium-doped fiber amplifier output power laser radiation is not visible, can not look directly at the device connector end when it works to avoid burning eyes and skin. Equipment includes precision optics, in order to avoid damage to the severe impact of its constitution, please avoid excessive vibration and impact. Pigtail easily sacrificed, so be careful. Equipment containing electrostatic sensitive devices, handle it carefully and make sure the ground is good, the power supply is normal. Attention of optic fiber end face: 1Before using, please be sure to keep the input and output end face of the optic fiber clean, especially if the output end face is dirt, then it is easy to make the output end face burned and the output power will be decreasing. When cleaning the optical fiber end face or insert patch cords, please turn off the input light first. 2The correct order of plugging optical port is: Inserting: first insert optical patch cord of output port, then insert optical patch cord of input port. Pulling out: first pull optical patch cord of input port, then pull optical patch cord of output port. 3This kind amplifier is a high precision and high stability product, in order to have high stability output power, please use optical patch cord with good quality and which connectors are match with the device to connect with the output port. In principle, the optical patch cord should be as short as possible, and do not let it voluntary movement. If there are any questions, please contact our company. Do not disassemble the module, otherwise it will cause irreparable damage Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Application Analog CATV Transmission FTTH Optical Access Optical Distribution Free Space Optical R&D and Training Feature High PowerUp to 2W total1 Unit for 20004000 optical node Low Noise FigureBelow 5.5dB ( +5dBm input) Er Yb co-doped DCF Amplify TechnologyPatent Pump Dump Technology Low CSO: -70dBc 23dBm×N20dBm×N or 17dBm×N output is optional Controllability and maneuverability: Dual CPU to deal Control loop and Communication separately High Stability And ReliabilityMTTF150000 Hours Redundancy Hot Swap power module: 110/220VAC and 48VDC can plug Mix Perfect Network InterfaceEthernet Support SNMP network management Intelligent Temperature Control System: using a dedicated Temperature control chip which make cooling and power loss reduce 30% than competitors Output Power can be Adjustable by network and manual Integrated 1310nm1490nm1550nm WDM (Optional) OEM, Module is available Description The product is high output power C-Band Er-Yb co-doped double cladding optical fiber amplifier. The key components of the product are high reliability multimode PUMP laser and the double cladding optical fiber. A proprietary ATC (Automatic Temperature Control) and APC (Automatic Power Control) circuit insures the high stability and reliability output power, the unique optical circuit design ensures the excellent optical performance. The high stability and high precision MPU system to ensure the control, adjustment and display are intelligent and easy. This amplifier employ double cladding Erbium Ytterbium co-doped fiber, and employ the high power multimode pump, with a 10 times Conversion efficiency higher than the single mode general technology, and therefore have a lower relative cost and more compact size and lower power consumption, in particular, for FTTH or FTTB or other large distribution system applications. Employ intelligent temperature control system: (1)Adopt special temperature control circuitheat radiating and power consumption can be reduced 30%, (2)The professional air flow design can also ensure the best temperature stability, at the same time powerful fan will start when the case temperature is over 45, meanwhile it will stop as the temperature is under 40.The technology makes sure the thermal stability of system and fan's long life. Intelligent network management system. Perfectly network interface: Ethernet networkand the open network management interface ensure the connectivity with all other network management system. These products are widely used in CATV transmission system and the high power distributing system FTTH requirement. It can be used for CATV analog/digital signal distribution, or match with PON system to construction the triple network integration. (Triple wavelength WDM is optional) Block Diagram Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Optical characteristics Parameter Operating Wavelength Saturated Output Power Note1 Input Power Gain Noise Figure Note2 Output Power Stability Input Isolator Output Isolator Input Pump Leakage Output Pump Leakage Return Loss Polarization Dependent Gain Polarization Mode Dispersion Symbol c Po Pi G NF Po ISOi ISOo PLi PLo RL PDG PMD Note 1Optional Note 2Tested at +5dBm Input MIN 1540 13 -3 --------------30 30 ----------------------------- TYP 1550 --------------------±0.05 ------------------------------------------- MAX 1565 33 +10 30 5.5 ±0.2 -----------35 -45 -45 0.3 0.5 UNITS nm dBm dBm dB dB dB dB dB dBm dBm dB dB ps Environmental characteristics Parameter Symbol MIN TYP MAX UNITS Operating Temperature Storage Temperature Humidity Note Tw Ts ------ -5 ----- 60 -40 ----- 80 10 ------ 90 % Note: No Condensate Electrical Characteristics Parameter Power Supply1 Power consumption Symbol MIN TYP MAX Vps 170 264 P ----- ----- 50 1: 110VAC220VAC and -48VDC is optional, and duplicate supply is optional. UNITS VAC W Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Starting up Before starting up, Please check the input voltage to the rated input voltage, grounding is good. The product adopts independent 220 VAC power supply. Equipment Powered Instructions Special Note: 1. The power module must be properly inserted in the device, so it can be supplied power. 2. Do not insert the charged power module into the device directly. LED/ Key Description key Upper button. Press this button can check each parameter of products from bottom to top. key Down button. Press this button can check each parameter of products from top to bottom. key Menu button. Press it can enter the menu. key Return button. Press it can return to the standby screen Display Menu Description 1Display device start up process when power on High Power Amplifier 2 Press the Menu button to display products model MODEL : EDFA 1550 3Press the down button to display internal temperature INTERNAL TEMP ** 4Press the down button to display the current of pump 1 LD1 CURRENT ***MA 5Press the down key to display the cooling current of pump 1 TEC1 CURRENT ***MA 6Press the down button to display the current of pump 2 LD2 CURRENT *.* A Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD 7Press the down button to display the temperature of pump 2 LD2 COOLER **.* 8 Press the down button to display the operating current of pump 3 LD3 Current *.* A 9Press the down button to display the temperature of pump tube 3: LD3 COOLER **.* 10 Press the down button to display input optical power: Input *.**mW *.*dBm 11 Press the down button to display output optical power: OUTPUT ***MW **.*DBM 12Press the down button to display working status: AGC Conerol *** In this screen, press the Menu button to display "ON" opens AGC function . If a high-power pump is damage, the other pump will increase the pumping power automatically to maintain the stability of output power. Press the Return key to display "OFF", this function is off. 13 Press the down button to display the status of the pump: PUMP CONTROL ** In this screen, press the Menu button to display "ON" pump working. Press the Return key to display "OFF" pumped off. Indicator Pump1 Pump 1 indicator off is normal, pump 1 flashing is alarming. Pump2 Pump 2 indicator off is normal, pump 2 flashing is alarming. Alarm Alarm Indicator: input and output light turns red when alarming. Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD AGC When the AGC function is turned on the light turns green. Interface Front-PanelBack-Panel Connectors Input 1~16 RJ45 Power1/2 Reset(optional) Description Optical input port Optical output ports Ethernet control port Power input 110/220V AC Short press: reboot net control board Long press: reset all net parameter to default Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Web Managment Login 1. Open Internet Explorer; 2. Input IP address into address box; 3. After the [Login] page have shown up, input UserName and password; 4. Press Login botton; Note: *1: Default IP address is 192.168.1.1 which can be modified at [Network Config] web page; *2: Default UserName and password both are admin which can be modified at [User Management] web page; Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Device Infomation After at successful login, the [Device Information] page will show up. There're three sections. 1. Device PowerMode: The name of electrical power source is using; LaserCount: Total number of laser pump is used; LaserType: 01=standard pump; Temperature: The case temperature of the device; InputPower: The input optical power of the device; OutputPower: The output optical power of the device; SystemStatus: OK=every thing goes well; otherwise the error message will be shown; 2. Laser Bias: the current of main pump; TEC: the current of the Thermo Electric Cooler; Temperature: the core temperature of the pump; 3. Power The main electrical power and backup electrical power supply status; Network Config Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD This page modifies the network parameters. User Management This page modifies the login account. You can change the user name and password here. Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD SNMP Config This page modifies the SNMP Community. You can changed the community of read or write here.(Only read community is using.) Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD SNMP Management SNMP Version 1 protocol is supported. The device related mib are defined as below. mib 1.3.6.1.4.1.17409.1.11.2.0 1.3.6.1.4.1.17409.1.11.3.0 1.3.6.1.4.1.17409.1.11.4.1.2.1 1.3.6.1.4.1.17409.1.11.4.1.2.2 1.3.6.1.4.1.17409.1.11.4.1.2.3 1.3.6.1.4.1.17409.1.11.4.1.3.1 1.3.6.1.4.1.17409.1.11.4.1.3.2 1.3.6.1.4.1.17409.1.11.4.1.3.3 1.3.6.1.4.1.17409.1.11.4.1.4.1 1.3.6.1.4.1.17409.1.11.4.1.4.2 1.3.6.1.4.1.17409.1.11.4.1.4.3 1.3.6.1.4.1.17409.1.11.7.1.2.1 1.3.6.1.4.1.17409.1.11.7.1.2.2 1.3.6.1.4.1.17409.1.3.1.13.0 1.3.6.1.4.1.17409.1.3.3.2.2.1.12.1 function Optical Input Power value*0.1dBm Optical Output Power value*0.1dBm Bias Current.1 value*1mA Bias Current.2 value*1mA(Reserved) Bias Current.3 value*1mA(Reserved) Tec Current.1 value*0.1A Tec Current.1 value*0.1A(Reserved) Tec Current.2 value*0.1A(Reserved) Pump Temperature.1 value*0.1deg Pump Temperature.1 value*0.1deg(Reserved) Pump Temperature.2 value*0.1deg(Reserved) DCPower Voltage.1 value*0.1V DCPower Voltage.2 value*0.1V Internal Temperature value*1deg Device Temperature value*1deg Laser Safety Information Class IV laser products. 9m/125m single-mode fiber pigtail with connector. Wavelength=0.90~1.68m Maximum Power=10W Order Information Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Category Application Input Power -- Output -- ports Power Power Interfa Network EDFA-1500 1 Power supply1 supply2 ce Management X 20 64 2 4 2 0 1U/ 2U/3U Rack 1: CATV 1-5~+10dBm 13:13dBm 1:1 port 1110VAC 1110VAC 1:SC/UPC 0None Dual power 2: DCM 2:+5~+15dBm 24:24dBm 2:2 port 2220VAC 2220VAC 2:SC/APC 1SNMP supply 3.Telecom single channel 3:0~+10dBm 4:4 port 4-48VDC 4-48VDC 3:FC/UPC 4:Telecom DWDM 4:-8~+10dBm 8:8 port 0: None 4:FC/APC 5:Wide Band single Channel 5:-35dBm~-25dBm( 16:16 port 5:LC/UPC Pre) 32:32 port 6:LC/APC 6:-25dBm~-10dBm( 64:64 port Online) 7:-10dBm~+6dBm( Booster) 9:Other Note 1EDFA-1500 for 1U rackMaxim ports number 16w/ WDMor 32w/o WDM Note 2High End configure with SNMP Net management. Note 3: 2U and 3U rack maxim 64 port with WDM Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn