Owner's Manual for LG models including: AMNW18GDCL0, LMN186HVT, AMNW18GDCL0 Room Air Conditioner, Room Air Conditioner, Air Conditioner, Conditioner
LG AMNW18GDCL0 LMN186HVT (01) PDF MANUAL - Manual-Hub.com
File Info : application/pdf, 6 Pages, 1.46MB
DocumentDocumentInternal Use Only http://www.lge.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AMNW18GDCL0 [LMN186HVT] CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. https://manual-hub.com/ 1. Specification Indoor Model Power Supply Ø / V / Hz Capacity(*) Btu/h Class Current Running Current A Fan Motor Type Fan Type Motor Output(W) x No. of Unit Air Flow Rate CMM (H / M / L) CFM External Static Pressure mmAq Capacitor F / Vac Drive Coil Row x Column x FPI Dimensions Body mm (W x H x D) inch Decorative Panel mm inch Net Weight Body kg (lbs) Decorative Panel kg (lbs) Air Filter Sound Level (H / M / L) dB(A)+3 Piping Liquid mm (inch) Connections Gas mm (inch) Drain(OD/ID) mm (inch) Dehumidification Rate l/h Safety Devices Temperature Sensor Refrigerant Refrigerant Control Transmission Interunit Cable No. x AWG AMNW18GDCL0 [LMAN186HV] 1/208-230/60 18,000 0.28 BLDC Cross Flow Fan 20x1 12/10/8.2 247/230/212 Direct Drive 3R x 18C x 22 1030 x 325 x 250 40-9/16 x 12-25/32 x 9-27/32 11(24.5) Long Life Filter 37/33/28 6.35 (1/4) 12.7 (1/2) 21.5/16 (0.846/0.630) 1.9 Fuse, Thermal Protector for Fan Motor Thermistor R410A EEV(in Outdoor unit or BD) 4×18(including earth) Note: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB - Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB - Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. Conversion Formula kW = Btu/h x 0.0002931 cfm = CMM x 35.3 Copyright ©2009 LG Electronics. Inc. All right reserved. Only for training and service purposes -2- https://manual-hub.com/ LGE Internal Use Only 2. Piping Diagrams Indoor Th4 Heat exchanger CFF Gas pipe connection port (flare connection) Th3 Th1 Th2 Liquid pipe connection port (flare connection) COOLING HEATING LOC. Th1 Th2 Th3 Th4 Description Thermistor for sunction air temperature Thermistor for evaporator inlet temperature Thermistor for evaporator outlet temperature Thermistor for evaporator middle temperature PCB Connector CN-TH1(Indoor) CN-TH2(Indoor) CN-TH3(Indoor) Copyright ©2009 LG Electronics. Inc. All right reserved. Only for training and service purposes -3- https://manual-hub.com/ LGE Internal Use Only 3. Wiring Diagrams Indoor Unit RY-COMP(3) CN-IN/N CN-SUB CN-DISP3 CN-U/D CN-12V CN-L/R CN-HVB CN-DISP1 CN-TH1 CN-TH2 CN-TH3 CN-DISPLAY CN-12V CN-SUB1 CN-U/D1 CN-COM CN-OPTION CN-SW CN-SUB CN-UD CN-U/D2 CN-L/R Copyright ©2009 LG Electronics. Inc. All right reserved. Only for training and service purposes -4- https://manual-hub.com/ LGE Internal Use Only 4. Exploded View 135316 152301 152313 159830B 159830A 135313 268711G 268711F W6631A 131410 135511 267110 359011 342800 149303 733010 135500C 149304 W50400 354212 352150 146811B 354210 W51620B W51620A 352116 35211B 352115 135090 346810 263230C 135500A 268711E 268711C W6640 266090 147582 135311 147581B 146811C 146811A 147581A 268711D 135500B 249951 263230A 263230B Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://www.lge.com) Copyright ©2009 LG Electronics. Inc. All right reserved. Only for training and service purposes -5- LGE Internal Use Only https://manual-hub.com/ P/NO : MFL61777626 NOVEMBER, 2010 https://manual-hub.com/