FortiSwitch 124G Series QuickStart Guide
FS-124G, FS-124G-FPOE
The Essentials
Secure your Network
Register at https://support.fortinet.com for the latest threat protection updates.
GUI
- Connect Port 1 to an Ethernet port or USB-RJ45 Ethernet adapter on your computer using an Ethernet cable (not included).
- Open a browser to https://192.168.1.99
CLI
- Connect the console cable (not included) to the Console Port.
- Open a Terminal app using 115200-8-N-1.
Default Logins
- URL: https://192.168.1.99
- Username: admin
- Password: leave blank
- FortiCloud Login: Username: user-defined, Password: user-defined
Fortinet Documents Library
For getting started documentation, admin guides, up-to-date hardware manuals, and reference resources, visit https://docs.fortinet.com/.
FortiEdge Cloud
Experience simplified cloud provisioning, zero touch deployment, configuration management, and reporting at https://fortiedge.forticloud.com.
Package Contents
FortiSwitch 124G Series
FS-124G, FS-124G-FPOE
- 1x FortiSwitch Device
- 1x QuickStart Guide
- 4x Rubber Feet
- 1x AC Power Cable
- 2x Rackmount Brackets, 6x Bracket Screws
Setup
GUI
Connection: Port 1 to Computer Ethernet Port
Access: https://192.168.1.99
Login: Username: admin, Password: (blank)
If Static IP: 192.168.1.1/24
CLI
Connection: Console Port via Console Cable
Terminal Settings: Speed: 115200, Data bits: 8, Stop bits: 1, Parity: None, Flow Control: None
FortiLink
- Login to the FortiGate and go to WiFi and Switch Controller -> FortiLink Interface.
- Add a FortiGate Port in the FortiLink interface.
- When the device is discovered, select Authorize.
Optional: To automatically authorize the device upon discovery, enable "Automatically authorize devices" in the FortiLink Interface settings.
FortiEdge Cloud
- Visit https://support.fortinet.com for registration and cloud management license.
- Sign in at https://fortiedge.forticloud.com to manage your Inventory List.
RackMount
- Secure the ears using the provided screws.
- Install in a rack using the provided screws.
Front FS-124G
1 CONSOLE Port (RJ-45): CLI management
2 PWR: Green: Device is on; Off: Device is off
ALARM: Amber: Fault detected; Off: No fault detected
BT/BLE (for future use): Blue: Bluetooth on; Off: Bluetooth off
3 RESET: Press and hold for 10secs to restore factory default settings
4 Ports 1 to 24 (RJ45):
- Left LED (100M/10M Mbps): Amber: Connected; Flashing Amber: Data activity; Off: Not connected
- Right LED (2.5/1 Gbps): Blue: 2.5 Gbps connected; Flashing Blue: 2.5 Gbps data activity; Green: 1 Gbps connected; Flashing Green: 1 Gbps data activity; Off: Not connected
5 USB 2.0 Port (USB A): for future use
6 Ports 25 to 30 (SFP+):
- Link/Activity: Blue: 10 Gbps connected; Flashing Blue: 10 Gbps data activity; Green: 1 Gbps/100 Mbps connected; Flashing Green: 1 Gbps/100 Mbps data activity; Off: Not connected
Rear FS-124G
1 Power Input: 100-240V AC, 1.5A Max, 50/60Hz
Front FS-124G-FPOE
1 CONSOLE Port (RJ45): CLI management
2 PWR: Green: Device is on; Off: Device is off
ALARM: Amber: Fault detected; Off: No fault detected
BT/BLE (for future use): Blue: Bluetooth on; Off: Bluetooth off
POE MAX (up to 780W): Amber: Max PoE power reached; Off: PoE power available
3 RESET: Press and hold for 10secs to restore factory default settings
4 Ports 1 to 8 (RJ45) PoE++:
- Left LED: Amber: Supplying PoE; Off: Not supplying PoE
- Right LED: Blue: 2.5 Gbps connected; Flashing Blue: 2.5 Gbps data activity; Green: 1000/100/10 Mbps connected; Flashing Green: 1000/100/10 Mbps data activity; Off: Not connected
5 Ports 9 to 24 (RJ45) PoE/PoE+:
- Left LED: Amber: Supplying PoE; Off: Not supplying PoE
- Right LED: Blue: 2.5 Gbps connected; Flashing Blue: 2.5 Gbps data activity; Green: 1000/100/10 Mbps connected; Flashing Green: 1000/100/10 Mbps data activity; Off: Not connected
6 USB 2.0 Port (USB A): for future use
7 Ports 25 to 30 (SFP+):
- Link/Activity: Blue: 10 Gbps connected; Flashing Blue: 10 Gbps data activity; Green: 1 Gbps/100 Mbps connected; Flashing Green: 1 Gbps/100 Mbps data activity; Off: Not connected
Rear FS-124G-FPOE
1 Power Input: 100-240V AC, 12A Max, 50/60Hz
Cautions and Warnings
Environmental specifications
Ambient operating temperature: 0°C to 45°C
Rack Mount Instructions:
- Elevated Operating Ambient: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Consider installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
- Reduced Air Flow: Installation of the equipment in a rack should not compromise the amount of air flow required for safe operation.
- Mechanical Loading: Mounting of the equipment in the rack should not create a hazardous condition due to uneven mechanical loading.
- Circuit Overloading: Consider the connection of the equipment to the supply circuit and the effect of overloading on overcurrent protection and supply wiring. Use equipment nameplate ratings.
- Reliable Earthing: Reliable earthing of rack-mounted equipment should be maintained. Pay attention to supply connections other than direct connections to the branch circuit (e.g., use of power strips).
Refer to the specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude).
Safety
Battery: Risk of explosion if the battery is replaced by an incorrect type. Do not dispose of batteries in a fire. Dispose of used batteries according to local regulations. (Switzerland: Annex 4.10 of SR814.013 applies to batteries.)
CAUTION: There is a danger of explosion if a battery is incorrectly replaced. Replace only with the same or equivalent type. Dispose batteries according to manufacturer's instructions. Disposing a battery into fire, a hot oven, or mechanically crushing or cutting it can result in an explosion. Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion. A battery subjected to extremely low air pressure may result in leakage of flammable liquid, gas, or an explosion.
WARNUNG: Lithium-Batterie Achtung: Explosionsgefahr bei fehlerhafter Batteriewechsel. Ersetzen Sie nur den gleichen oder gleichwertigen Typ. Batterien gemäß den Anweisungen des Herstellers entsorgen. Beseitigung einer BATTERIE in Feuer oder einen heißen Ofen oder mechanisches Zerkleinern oder Schneiden einer BATTERIE, die zu einer EXPLOSION führen kann. Verlassen einer BATTERIE in einer extrem hohen Umgebungstemperatur, die zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder Gas führen kann. Eine BATTERIE, die einem extrem niedrigen Luftdruck ausgesetzt ist, der zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder Gas führen kann.
Caution: This equipment is to be used in a Network Environment 0 per IECTR 62101. This product is connected only to PoE networks without routing to the outside plant.
Grounding: To prevent damage to your equipment, connections that enter from outside the building should pass through a lightning/surge protector and be properly grounded. Use an electrostatic discharge workstation (ESD) and/or wear an anti-static wrist strap. In addition to the grounding terminal of the plug, on the back panel, there is another, separate terminal for earthing. This separate protective earthing terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size #14AWG and the connection is to be installed by qualified service personnel.
Regulatory Notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
WARNING: Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Innovation, Science and Economic Development (ISED) – Canada
CAN ICES-003 (A) / NMB-003 (A)
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
This radio transmitter (IC: 7280B-240701) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
This device and its antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC multi-transmitter product procedures.
Antenna No. | Antenna Type | Antenna Peak Gain | Network |
---|---|---|---|
1 | FPC | 2.0 dBi | Bluetooth |
European Conformity (CE) - EU
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
CE
The product transmits within the frequency ranges and less than or equal to the power listed below: 2402-2480MHz less than 20dBm (EIRP).
This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including combinations of software, firmware, and hardware) provided by Fortinet or Fortinet's authorized partners to the end customer directly for use within the EU or countries that have implemented the EU Directives and/or spectrum regulation. Any Fortinet products not obtained directly from Fortinet or Fortinet's authorized partners may not comply with EU Directives, and Fortinet makes no assurances for such products.
Български: Този продукт е в съответствие с Директива 2014/53/EC.
Česky: Tento produkt je v souladu se směrnicí 2014/53/EU.
Dansk: Dette produkt er i overensstemmelse med direktiv 2014/53/EU.
Deutsch: Dieses Produkt entspricht der Richtlinie 2014/53/EU.
Eesti: See toode vastab direktiivile 2014/53/EL.
English: This product is in compliance with Directive 2014/53/EU.
Español: Este producto cumple con la Directiva 2014/53/UE.
Ελληνική: Το προϊόν αυτό συμμορφώνεται με την Οδηγία 2014/53/ΕΕ.
Français: Ce produit est conforme à la Directive 2014/53/UE.
Hrvatski: Ovaj proizvod je u skladu s Direktivom 2014/53/EU.
Italiano: Questo prodotto è conforme alla Direttiva 2014/53/EU.
Latviski: Šis produkts atbilst Direktīvai 2014/53/EU.
Lietuvių: Šis gaminys atitinka direktyvą 2014/53/ES.
Malti: Dan il-prodott huwa konformi mad-Direttiva 2014/53/UE.
Magyar: Ez a termék megfelel a 2014/53/EU irányelvnek.
Nederlands: Dit product is in overeenstemming met Richtlijn 2014/53/EU.
Norsk: Dette produktet er i samsvar med direktiv 2014/53/EU.
Polski: Ten produkt jest zgodny z dyrektywą 2014/53/UE.
Português: Este produto está em conformidade com a Diretiva 2014/53/UE.
Rumunski: Acest produs este în conformitate cu Directiva 2014/53/UE.
Slovensky: Tento produkt je v súlade so smernicou 2014/53/EÚ.
Slovensko: Ta izdelek je v skladu z Direktivo 2014/53/EU.
Suomi: Tämä tuote on direktiivin 2014/53/EU mukainen.
Svenska: Denna produkt överensstämmer med direktiv 2014/53/EU.
Note: The full declaration of conformity for this product is available at the link: https://site.fortinet.com/ProductRegulatory/EU
UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to the power listed below: 2402-2480MHz less than 20dBm (EIRP).
This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
This product is in compliance with Statutory Instrument 1206 Radio Equipment Regulations 2017.
The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/UK
Voluntary Control Council for Interference (VCCI) – Japan
この装置は、クラスA機器です。この装置を住宅環境で使用すると電波妨害を引き起こすことがあります。この場合には使用者が適切な対策を講ずるよう要求されることがあります。
VCCI-A
Product Safety Electrical Appliance and Material (PSE) – Japan
日本では電気用品安全法(PSE)の規定により、同梱している電源コードは本製品の専用電源コードとして利用し、他の製品に使用しないでください。
Bureau of Standards Metrology and Inspection (BSMI) – Taiwan
The presence conditions of the restricted substance (BSMI ROHS table) are available at the link below: 限用物質含有情況表 (RoHS Table) 請到以下網址下載: https://www.fortinet.com/bsmi
警告: 為避免電磁干擾,本產品不應安裝或使用於住宅環境。
請仔細閱讀以下說明
本設備勿置於潮濕處。
連接至電源前,請先檢查電壓。
當設備不用時,請將所有電源線拔除,避免電壓不穩而造成傷害。
勿將任何液體濺入設備中,避免線路短路。
基於安全理由,只有受到專業訓練的從業人員,才可以打開本設備。
請勿自行調整或修理已通電的設備,以確保您的安全。
如不小心受傷,請立刻找急救人員給予您適當的救護,千萬別因傷勢輕微而忽略自己的傷勢。
請依照台灣法規處置電池。
若不正確替換電池可能導致爆炸危險,替換電池時,請使用設備生產商推薦使用的電池。
請勿拆卸、刺穿或以其他方式損壞電池。
雷射設備非用戶維修設備,請與生產商聯繫維修事宜。
英屬蓋曼群島商防特網股份有限公司台灣分公司 地址:台北市內湖區行愛路176號2樓 電話:(02)27961666
National Telecommunications Commission (NCC) – Taiwan
NCC警語 取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前述合法通信,指依電信管理法規定作業之無線電通信。低功率射頻器材須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。
China
警告:在居住环境中,运行此设备可能会造成无线电干扰。
Copyright and Warranty
January 23, 2025
Copyright © 2025 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments, and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties, whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinet's SVP Legal and above, with a purchaser that expressly warrants that the identified product will perform according to certain expressly-identified performance metrics and, in such event, only the specific performance metrics expressly identified in such binding written contract shall be binding on Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet's internal lab tests. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied. Fortinet reserves the right to change, modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable.
For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf
FortiSwitch-124G-Series-QSG-20250123