Instruction Manual for AUTOMATE models including: MT03-0301-411005, DC Power Distribution Panel

Programming Instructions: DC Power Distribution Panel ...

6 | Automate™ Installation Instructions | DC Power Distribution Panel ROLLEASE ACMEDA ROLLEASE ACMEDA MOTORS MTDCRF25-1.1 MTDCRF28-2 MTDCRF35-3 MTDCRFQ45-3 MTDCRF45-10 MTDCRF-CL-0.6-50 MT01-3001- 069001 TILT-1 14V 14V 12V 12V 14V 12V CABLE RUN LENGTH TOTAL (m) ≤15m 24 AWG 24 AWG 22 AWG 20 AWG 20 AWG 18 AWG 20m 24 AWG 24 AWG 20 AWG 20 AWG 20 AWG 18 AWG

DC Power Distribution Panel

MOTOR PROGRAMMING INSTRUCTIONS DC Power Distribution Panel

6 | Automate™ Installation Instructions | DC Power Distribution Panel ROLLEASE ACMEDA ROLLEASE ACMEDA MOTORS MTDCRF25-1.1 MTDCRF28-2 MTDCRF35-3 MTDCRFQ45-3 MTDCRF45-10 MTDCRF-CL-.6-50 MT01-3001- 069001 TILT-1 14V 14V 12V 12V 14V 12V CABLE RUN LENGTH TOTAL (m) ≤15m 24 AWG 24 AWG 22 AWG 20 AWG 20 AWG 18 AWG 20m 24 AWG 24 AWG 20 AWG 20 AWG 20 AWG 18 AWG


File Info : application/pdf, 16 Pages, 2.65MB

PDF preview unavailable. Download the PDF instead.

Programming Instructions - DC Power Distribution Panel
MOTOR PROGRAMMING INSTRUCTIONS
DC Power Distribution Panel

RELIABLE, COST LED STATUS EFFECIVE POWER

SECURE LOCK

DIFFERENT WIRE TYPES

AUTOMATE | DC Power Distribution Panel provides power for up to 18 separate ARC DC motors. Higher 15V output allows for greater cable lengths from motor to power panel, freeing up routing options within an installation.

Removes the need for multiple individual power adaptors for each DC motor in an installation, combining each power source into a single location. Channels may also be wired in parallel to provide additional power to larger motors. Additional information and updates are available at https://www.rolleaseacmeda.com

FEATURES: · Capacity for up to 18 ARC DC motors (25mm and 28mm motors) · Ability to parallel connect motor supplies for higher current motors (35mm and 45mm motors) · LED status indication for checking whether power is being applied to panel · LED status indication for each individual motor supply

Part #: MT03-0301-411005 Automate |15V DC,24A,360W, 18CH Power 100-240VAC

INSTR. MT03-0301-411005 V1.7 JAN 2021

CONTENTS

1 FEATURES

3

2 SAFETY INSTRUCTIONS

4

3 INSTALLATION

6

3.1 Cable Run Reference Table (Maximum Lengths)

6

3.2 Motor Power Distribution Setup

7

3.3 Wiring Diagram ­ Individual Connection (MTDCRF28/25)

8

3.4 Wiring Diagram ­ Two Wire Entry Connections in Parallel (MTDCRF45/35)

8

3.5 JST Connector Recommendations for Custom Cable Adaptors

9

3.6 Status LED Indication

10

4 SPECIFICATIONS

10

5 TROUBLESHOOTING

11

6 WIRE GAUGE DIMENSIONS

11

APPENDIX CONTENTS

12

2 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

1 FEATURES
1. Internal power Switch 2. Mains Power supply (120V/240V) 3. 18 wire entries with clamp screws 4. IEC-C14 Connector for Mains Power Input 5. 18 Individual fuses for channel protection
(Quick Blow Fuse 3.15A M205) 6. 18 Channel Status LEDs 7. Plastic Plugs (For cable routing) 8. Potentiometer for output voltage adjustment 9. Cooling fan 10. Terminal Block
Note: Keys can't be replaced if lost.

2 1

8 1

1 1

1 4 3 1

OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 OUT 13 OUT 14 OUT 15 OUT 16 OUT 17 OUT 18

7 1
6 5 91 101

3 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

2 SAFETY INSTRUCTIONS
WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury, which may result in death and will void manufacturer's liability and warranty. AVERTISSEMENT: Consignes de sécurité importantes à lire avant l'installation. Une installation incorrecte peut entraîner des blessures graves, voire mortelles, et annule la responsabilité et la garantie du fabricant.

OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 OUT 13 OUT 14 OUT 15 OUT 16 OUT 17 OUT 18 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 OUT 13 OUT 14 OUT 15 OUT 16 OUT 17 OUT 18

CAUTION · Do not expose to moisture or extreme environments. · Do not allow children to play with this device. · Use or modification outside the scope of this instruction manual will void warranty. · Installation and setup to be performed by a suitably qualified installer. · For use with DC powered motorized shading devices. · Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. · Keep clear when in operation. · For use with DC motors only (NOT suitable for charging Li-ion Battery powered motors). · Do not cut power cables · Do not drill into motor body or distribution panel. · The routing of cable through walls shall be protected by isolating bushing or grommets. · Ensure motor power cable and aerial is clear and protected from moving parts.
· If cable or power connector is damaged do not use.

MISE EN GARDE

·

Ne pas exposer à l'humidité ou à des environnements extrêmes.

·

Ne laissez pas les enfants jouer avec cet appareil.

·

Toute utilisation ou modification en dehors de ce manuel d'instructions annulera la garantie.

·

L'installation et la configuration doivent être effectuées par un installateur qualifié.

·

À utiliser avec les dispositifs d'ombrage motorisés alimentés en courant continu.

·

Inspectez fréquemment l'utilisation non conforme. Ne pas utiliser si une réparation ou un réglage est nécessaire.

·

Restez à l'écart lors de l'exploitation.

·

À utiliser uniquement avec des moteurs à courant continu (NE convient PAS pour charger des moteurs alimentés

par batterie Li-ion).

·

Ne pas couper les câbles d'alimentation

·

Ne percez pas dans le corps du moteur ou le panneau de distribution.

·

Le passage des câbles à travers les murs doit être protégé en isolant les traversées ou les passe-câbles.

·

Assurez-vous que le câble d'alimentation du moteur et l'antenne sont dégagés et protégés des pièces mobiles.

·

Si le câble ou le connecteur d'alimentation est endommagé, ne l'utilisez pas.

4 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

2 SAFETY INSTRUCTIONS
Important safety instructions to be read prior to operation. · It is important for the safety of persons to follow the enclosed instructions. · Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge
should not be allowed to use this product. · Frequently inspect for improper operation. Do not use if repair or adjustment is necessary.

Consignes de sécurité importantes à lire avant utilisation.

·

Pour la sécurité des personnes, il est important de suivre les instructions fournies.

·

Les personnes (y compris les enfants) dont les capacités physiques, sensorielles ou mentales sont réduites ou qui

manquent d'expérience et de connaissances ne devraient pas être autorisées à utiliser ce produit.

·

Gardez les télécommandes hors de la portée des enfants.

·

Inspectez fréquemment l'utilisation non conforme. Ne pas utiliser si une réparation ou un réglage est nécessaire.

Save these instructions for future reference. Conservez ces instructions pour référence future.
Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. Ne pas jeter avec les déchets ordinaires. Veuillez recycler les piles et les produits électriques endommagés de manière appropriée.
5 | AutomateTM Installation Instructions | DC Power Distribution Panel

5014360 ROLLEASE ACMEDA

3 INSTALLATION 3.1 Cable Run Reference Table (Maximum Lengths)
IMPORTANT!
MOTOR POWER CABLE RUN LENGTHS MUST NOT EXCEED THE DISTANCES IN THE REFERENCE TABLE BELOW WHEN VOLTAGE HAS BEEN REDUCED FOR USE WITH AUTOMATE PULSE 2 HUB AND APPLICATION. Failure to do so will result in loss of voltage along the cable run, subsequently resulting in insufficient voltage at the motor input terminals. Before connection of any motors to the power distribution panel, check cable lengths and wire gauge (AWG), against this table in order to ensure system will operate to specification.

MTDCRF25-1.1 MTDCRF28-2 MTDCRF35-3 MTDCRFQ45-3 MTDCRF45-10
MTDCRFCL-0.6-50 MT01-3001-
069001 MTDCRF-
TILT-1

CABLE RUN LENGTH TOTAL (m)

ROLLEASE ACMEDA MOTORS

14V

14V

12V

12V

14V

15m

24 AWG

24 AWG

22 AWG

20 AWG

20 AWG

20m

24 AWG

24 AWG

20 AWG

20 AWG

20 AWG

25m

24 AWG

22 AWG

20 AWG

20 AWG

20 AWG

30m

24 AWG

22 AWG

18 AWG

20 AWG

20 AWG

35m

22 AWG

20 AWG

18 AWG

20 AWG

20 AWG

40m

22 AWG

20 AWG

18 AWG

20 AWG

20 AWG

45m

22 AWG

20 AWG

18 AWG

20 AWG

20 AWG

50m - 60m

20 AWG

18 AWG

16 AWG

20 AWG

20 AWG

65m

20 AWG

18 AWG

16 AWG

18 AWG

20 AWG

70m

20 AWG

18 AWG

16 AWG

18 AWG

20 AWG

75m

20 AWG

18 AWG

N/A

18 AWG

20 AWG

80m

18 AWG

16 AWG

N/A

18 AWG

18 AWG

85m

18 AWG

16 AWG

N/A

18 AWG

18 AWG

90m

18 AWG

16 AWG

N/A

18 AWG

18 AWG

95m

18 AWG

16 AWG

N/A

18 AWG

18 AWG

100m

18 AWG

16 AWG

N/A

16 AWG

18 AWG

105m

18 AWG

16 AWG

N/A

16 AWG

18 AWG

110m

18 AWG

16 AWG

N/A

16 AWG

18 AWG

115m

18 AWG

16 AWG

N/A

16 AWG

18 AWG

120m - 160m 16 AWG

N/A

N/A

16 AWG

16 AWG

165m

16 AWG

N/A

N/A

N/A

16 AWG

170m

16 AWG

N/A

N/A

N/A

16 AWG

175m

16 AWG

N/A

N/A

N/A

16 AWG

180m

16 AWG

N/A

N/A

N/A

16 AWG

185m - 210m

N/A

N/A

N/A

N/A

16 AWG

215m

N/A

N/A

N/A

N/A

N/A

*Refer to section 6 on page 11 for detailed American Wire Gauge (AWG) dimensions

12V 18 AWG 18 AWG 18 AWG 18 AWG 18 AWG 18 AWG 18 AWG 16 AWG 16 AWG 16 AWG
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

6 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

3.2 Motor Power Distribution Setup
OVERVIEW
· One wire entry is connected to one of MTDCRF28/25 motors. · Two wire entries are connected to one of MTDCRF45/35 motors. · All motor connections must be made before power applies to the distribution panel. · Use of two parallel connections ensures the power supply is not overloaded during
larger motor operation.
Mains Power (120V/240V) MT03-0304-050007 - Automate|1.8M/6FT 3 PIN US Plug AC Power Cord Adaptor (required one per Panel) Cable Run

OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 OUT 13 OUT 14 OUT 15 OUT 16 OUT 17 OUT 18

MT03-0301-069012 - Automate Connection Harness for DCRF Motors-JST sc (required one per motor)
7 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

3.3 Wiring Diagram ­ Individual Connection (MTDCRF28/25)
Low power motors may be connected individually to one wire entry of the terminal block, with care being taken to ensure polarity is correct (see page 4). Incorrect polarity will stop the motor from functioning.
Cable Run

This connection may only be used when wiring 28mm & 25mm motors to the distribution panel, as these motors do not exceed the 1.33 A current limit per channel.
3.4 Wiring Diagram ­ Two Wire Entry Connections in Parallel (MTDCRF45/35)
IMPORTANT!
WARNING: Important instructions to read before commencing wiring of 45mm and 35mm motors. Due to higher power demands, these motors must be wired in a parallel configuration (shown below) utilizing two wire entries in order to avoid overloading the power circuit and blow the protection fuses. AVERTISSEMENT: Les instructions importantes à lire avant de commencer le câblage de 45mm et Moteurs 35mm. En raison de demandes de puissance plus élevées, ces moteurs doivent être câblés dans une configuration parallèle (illustrée ci-dessous) en utilisant deux canaux afin d'éviter de surcharger le circuit d'alimentation et d'endommager le tableau de distribution.

Positive Negative

Due to 1.33A limit per channel, working current can be doubled to 2.66A with parallel configuration as shown above, allowing connection of 45mm and 35mm motors.
En raison de la limite de 1,33 A par canal, le courant de travail peut être doublé à 2,66 A avec une configuration en parallèle, comme indiqué ci-dessus, permettant la connexion de moteurs de 45 mm et 35 mm.

8 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

CAUTION: Before plugging in this equipment to mains power;

·

Ensure the internal power switch 1 (page 2) is in the OFF position.

·

Check the mains input 2 (page 2) DC output for any loose wires, ensuring the plastic safety covers are covering the main power supply.

·

Check motor connection terminal blocks 10 (page 2) for loose wires, as well as polarity check each connection (See below)

ATTENTION: Avant de brancher cet équipement sur le secteur;

·

Assurez-vous que l'interrupteur d'alimentation interne 1 (page 2) est en position OFF.

·

Vérifiez que l'entrée secteur 2 (page 2) ne comporte pas de fils desserrés à la sortie CC, en veillant à ce que les capots de protection en

plastique soient en place. couvrant les borniers.

·

Vérifiez que les borniers de connexion du moteur 10 (page 2) ne présentent pas de fils desserrés, ainsi que la polarité. connexion (voir

ci-dessous)

Overmolded 2 PIN terminal block part, white

2PIN JST connector, Red

Motor

Cable Run

Power Panel
PART #: MT03-0301-069012 DESCRIPTION: Automate Connection Harness for DCRF Motors - JST to Screw connectors

WIRING POLARITY FROM PANEL TO MOTOR

Female (Power Output)

Grey Dashes (Positive)

Male (Motor Input)

Solid White (Positive)

3.5 JST Connector Recommendations for Custom Cable Adaptors

Rollease Acmeda recommends the following JST connectors for DC power connections:

RECOMMENDED JST CONNECTORS

DESCRIPTION

PART NO.

MANUFACTURER

Male Connector (White)

SYR-02TV

JST SALES AMERICA INC.

Male Connector (Red)

SYR-02T

JST SALES AMERICA INC.

Male Pin Contact

SYM-001T-P0.6(N)

JST SALES AMERICA INC.

Digikey.com PART NO. 455-2655-ND 455-2653-ND 455-1909-1-ND

9 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

3.6 Status LED Indication
IMPORTANT!
Status LEDs for each motor channel indicate the condition of the inline fuse. If the status LED is not lit up when power is supplied to the panel, then the inline fuse for that channel has blown. Disconnect all power to the Panel and inspect the individual motor and supply cable to the motor in order to determine why the fault occurred. Once the fault has been determined, make the appropriate repairs and replace the fuse with a 3.15A M205 quick blow fuse.

3.15A M205 fuse in plastic cradle

Green Fuse Status LED

In order to replace fuse, carefully pry the fuse out of the plastic cradle using a small tool (such as a small screwdriver or pen). To replace, gently press the new fuse into the cradle.
To test LED, apply power to the distribution panel, and observe whether the channel LED is glowing.
4 SPECIFICATIONS

TECHNICAL SPECIFICATIONS PARAMETERS Input Voltage Range Output Voltage Range Maximum Output Current (all 18 channels) Power Output Rating Single Channel Absolute Maximum Current Output Ingress Protection

VALUE 100 VAC - 240 VAC
11.4 - 15 VDC 24 A 360 W 1.33 A IP20

10 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

5 TROUBLESHOOTING

IMPORTANT!
WARNING: Distribution panel is connected to (120V/240V) mains power. Do not attempt to troubleshoot panel without first disconnecting all power and waiting a period of 5 minutes. AVERTISSEMENT: le panneau de distribution est connecté au secteur (120V / 240V). Ne pas tenter dépanner le panneau sans d'abord couper l'alimentation et attendre un certain temps de 5 minutes.

PROBLEM No Motors are responding
Individual Motor is not responding

CAUSE A/C power supply not plugged in
Internal power switch turned off
A/C terminal block wiring is incorrect
Motor channel fuse has blown Motor wiring is incorrect Motor is in sleep mode

REMEDY
Check exterior LED
Check Panel to power connection and IEC connector and AC plug
Power is supplied to panel, but exterior LED is not lit. Open panel and switch internal power switch to ON position
CAUTION: Do NOT attempt to rewire mains power terminal block. Only to be performed by a suitably qualified installer
Check individual LED's
Replace fuse as necessary (refer to section 1.5)
Refer to wiring diagram on page 6
Refer to motor's programming instructions in order to change motor sleep status

6 WIRE GAUGE DIMENSIONS

WIRE GAUGE 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG

AMERICAN WIRE GAUGE DIMENSIONS DIAMETER
0.51054 mm (0.0201 in) 0.64516 mm (0.0254 in)
0.8128 mm (0.032 in) 1.02362 mm (0.0403 in) 1.29032 mm (0.0508 in)

11 | AutomateTM Installation Instructions | DC Power Distribution Panel

CROSS-SECTIONAL AREA 0.205 mm2 (0.00032 in2) 0.326 mm2 (0.00051 in2) 0.518 mm2 (0.00080 in2) 0.823 mm2 (0.00128 in2) 1.31 mm2 (0.00203 in2) ROLLEASE ACMEDA

APPENDIX CONTENTS

A APPENDIX 1 | DC POWER DIST. PANEL + PULSE 2.0 HUB & APP.

12

A.1 PULSE 2.0 HUB - ADDITIONAL INSTALLATION/SET UP INSTRUCTIONS

13

A.2 ADJUSTMENT PROCEDURE

13

A.3 TROUBLE SHOOTING

14

A.4 NOTES

15

A APPENDIX 1 | DC POWER DIST. PANEL + PULSE 2.0 HUB & APP.

12 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

A.1 PULSE 2.0 HUB - ADDITIONAL INSTALLATION/SET UP INSTRUCTIONS

IMPORTANT!

If motors powered by the DC Power Distribution Panel are to be used with the Automate Pulse 2 Hub and Application, the output voltage of the Distribution Panel MUST be adjusted to allow for proper communication between the Hub and Motor.
Output Voltage (11.4VDC to 15VDC) of the DC Power Distribution Panel can be adjusted via the Trim-Pot located on the converter within the Distribution Panel. NOTE: Adjusted Output voltage is applicable to all 18 Channels.

IMPORTANT!
If motors are connected to the Automate Pulse 2 Hub, it is RECOMMENDED the motors of the same type (MTDCRF28/25 or MTDCRF45/35) are used in the installation. It is NOT recommended to power motors of differing types from one DC Power Distribution Panel.

A.2 ADJUSTMENT PROCEDURE

IMPORTANT!
WARNING: DANGEROUS LIVE VOLTAGE. DO NOT ATTEMPT UNLESS QUALIFIED TO OPERATE AC MAINS VOLTAGE DEVICES.

Output Voltage of the Distribution Panel must be monitored as it is adjusted. This involves probing the output of the Panel while it is live. Monitor output voltage using a multimeter, and adjust potentiometer using an appropriately sized Philips Head screwdriver. When motors are to be controlled via the Automate Pulse 2 Hub, the maximum allowable voltages for each motor is as shown:

14V

12V

MOTOR MTDCRF35-3 MTDCRFQ45-3 MTDCRF45-10 MTDCRF-CL-0.6-50 MTDCRF-TILT-1 MTDCRF25-1.1 MTDCRF28-2 MT01-3001-069001

13 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

A.3 TROUBLE SHOOTING

IMPORTANT!
WARNING: Distribution panel is connected to (120V/240V) mains power. Do not attempt to troubleshoot panel without first disconnecting all power and waiting a period of 5 minutes.
AVERTISSEMENT: le panneau de distribution est connecté au secteur (120V / 240V). Ne pas tenter dépanner le panneau sans d'abord couper l'alimentation et attendre un certain temps de 5 minutes.

PROBLEM
Motor is not responding to the App/ updating App animation and motor position

CAUSE Panel Output Voltage is too low

REMEDY Adjust Trim-Pot to increase output voltage

Motor showing as offline

Voltage at motor terminal is too high/too low

Adjust Trim-Pot to decrease/increase the output voltage

14 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

A.4 NOTES

15 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA

ROLLEASE ACMEDA | USA
Level 7 / 750 East Main Street Stamford, CT 06902, USA
T +1 800 552 5100 | F +1 203 964 0513

ROLLEASE ACMEDA | AUSTRALIA
110 Northcorp Boulevard, Broadmeadows VIC 3047, AUS
T +61 3 9355 0100 | F +61 3 9355 0110

16 | AutomateTM Installation Instructions | DC Power Distribution Panel

ROLLEASE ACMEDA | EUROPE Via Conca Del Naviglio 18, Milan (Lombardia) Italy T +39 02 8982 7317 | F +39 02 8982 7317
ROLLEASE ACMEDA


Adobe PDF Library 15.0 Adobe InDesign 16.1 (Windows)