User Guide for dacor models including: HDPR30S Heritage Dual Fuel Pro Range, HDPR30S, Heritage Dual Fuel Pro Range, Dual Fuel Pro Range, Fuel Pro Range, Pro Range, Range
DACOR HERITAGE HDPR48S (01) PDF MANUAL - MANUAL-HUB.COM
File Info : application/pdf, 3 Pages, 1.04MB
DocumentDocumentHDPRS/HDERS Doc #: PGH-HDPR/ER.01 Revised 22 May 2018 Page1of 3 All tolerances: ±¹/" (±1.6 mm), unless otherwise stated. Heritag e® 30", 36", 48" Wide, Dual-Fuel Ranges PLANNING GUIDE WARNING · Observe all governing codes and ordinances during planning and installation. Contact your local building department fordetails.t · The range must be installed as specified in its installation instructions. Critical Depth/Height Dimensions HDPRS model shown; common dimensions given; unique HDPRS/HDERS dimensions indicated Range-Only Installation All specifications subject to change without notice. Range-With-Downdraft Installation www.dacor.com https://manual-hub.com/ Ph. 800.793.0093 HDPRS/HDERS Page 2 of 3 All tolerances: ±¹/" (±1.6 mm), unless otherwise stated. Heritag e® 30", 36", 48" Wide, Dual-Fuel Ranges PLANNING GUIDE ELECTRICAL REQUIREMENTS Model Required Circuit Total Connected Load HDPR30S, HDER30S 240Vac*, 60 Hz, 30 Amp. HDPR36S, HDER36S 5.75kW(24.0 Amp.) HDPR48S, HDER48S 240Vac*, 60 Hz, 50 Amp. 10.1kW(41.9Amp.) *4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground; these ratings are for reference only; see the range's data label (back of range) forexact specifications. The wiring must be long enough that the range can be pulled out for service, without being disconnected. Wiring to the range must: · meet NEMA standards and the requirements in the abovetable · include a strain relief · be terminated by tinned leads, closed-loop terminals, oropen- ended spade lugs with upturned ends · connect to a junction box or receptacle installed by a licensed electrician. The range maybe connected via one of these two methods: · 4-wire conduit connected to a 4-wire junction box · 3-wire conduit (where local code permits, not for use with new branch circuit installations) connected to a 3-wire junction box. Using a power cord: · A 4-wire power cord with a NEMA14-50P plug connected to a NEMA 14-50R receptacle: MINIMUM GAS-SUPPLY PRESSURE REQUIREMENTS* Gas Type Min. Manifold Pressure Min. Gas-Supply Pressure** Natural 5" watercolumn 6" watercolumn LP (propane) 10" water column 11"water column *Gas-supply pressure for testing the regulator setting shall be at least 1"water column (249 Pa) above the specified manifold pressure; **Max gas-supply pressure, all models: 1/2psi. The above ratings are for reference only; see the rating label (upper-rearof range) for exactspecifications. 48" modelshown · A 3-wire power cord (where permitted) with a NEMA10-50P plug connected to a NEMA 10-50R receptacle · The power-cord plug must be UL listed type SRD or SRDT. · Range models DYRP36D-C-S and DYRP48D-C-S come with a factory installed 4-wire appliance cord with NEMA14-50P plug. For freestanding ranges installed in Canada, a factory installed 4-wire appliance cord with NEMA 14-50P plug is required, without modification. GAS-/ELECTRICAL-ACCESS DIMENSIONS Model A B* C D* E** HDPR30S/ HDER30S HDPR36S/ HDER36S HDPR48S/ HDER48S 3 1/4" (8.3 cm) 6 3/4" (17.1cm) 4 1/4" (10.8 cm) 27" (68.6 cm) 27" (68.6 cm) 27" (68.6 cm) 6 3/4" (17.1cm) 12" (30.5 cm) 9" (22.9 cm) 6 3/4 (17.1cm) 7/8" (2.2 cm) dia. *Measurement with range legs adjusted to their lowest height; **the hole size for the electrical wiring may be increased to11/8"(2.9 cm) by removing the conduit bracket in the bottom of the electrical box. All specifications subject to change without notice. www.dacor.com https://manual-hub.com/ Ph. 800.793.0093 HDPRS/HDERS Page 3 of 3 All tolerances: ±¹/" (±1.6 mm), unless otherwise stated. Heritag e® 30", 36", 48" Wide, Dual-Fuel Ranges PLANNING GUIDE Cabinet Layout · All maximum/minimum dimensions and clearances in the diagrams below must be maintained for safeoperation. · Place the range away from drafts (open doors and windows,and home heating/cooling systems). · Do not install cabinets over the range, or to reduce risk of burn injury from reaching over a hot cooktop, install a range hood that projects horizontally at least 5"beyond the cabinet bottoms. · The range may be installed against the rear wall. Dacor strongly recommends installing a backguard or non-combustible material on the rear wall between the range vent hood. · Seal openings in the wall behind the range and in the floor below. · The grey area in the diagram below shows the suggested gas/ electrical utilities. Existing utilities may be used if they do not hinder range placement. · Gas/electrical utilities must be located so the range can be moved for service without beingdisconnected. · An external, manual shut-off valve must be installed between the gas inlet and range so gas to the range can be shut on/off. · Installation must allow access to the gas shut-off valve and circuit-breaker panel/fuse box when the range is in place. Model HDPRS/HDERS 30 HDPRS/HDERS 36 HDPRS/HDERS 48 CUTOUT DIMENSIONS F: recommended/min. G: min./max. 36"(91.4cm) / 30" (76.2cm) 30" (76.2 cm) / 30 1/8"(76.5cm) 42" (106.7 cm) / 36"(91.4cm) 36"(91.4cm) / 36 1/8"(91.8cm) 54"(137.2cm) / 48" (122.0cm) 48" (121.9cm) / 48 1/8"(122.2cm) H 27 3/8"(69.5 cm) 33 1/2"(84.8 cm) 43 1/2"(110.5cm) Standard Cutoutwith Range Hood APPROVED DOWNDRAFTVENTS Range Downdraft Vent HDPRS/HDERS 30 MRV3015 HDPRS/HDERS 36 MRV36-ER HDPRS/HDERS 48 MRV48-ER IMPORTANT: See downdraft installation instructions for duct and electrical installation requirements. Use only approved Dacordowndraft vents. All specifications subject to change without notice. Countertop Cutout For Downdraft Vent 1. Vertical from range grate level to combustible overhead surface; if installing an overhead hood, see hood specifications for minimum required clearances. 2. Cabinet/countertop depth is at customer discretion, but cabinet face must not protrude beyond rear of range front panel. (See Pg. 1fordimensions.) 3. Consult localcodes for exact location requirements. 4. Vertical from grate level to combustible surface. 5. Not applicable to cabinets that horizontally are over10" (25.4 cm) from range edge. www.dacor.com Ph. 800.793.0093 https://manual-hub.com/