This guide describes how to install the UR32 and how to log in the Web GUI to configure the device. Once you complete the installation, ...

Quick Start Guide

Quick-Start-UR32 - ICPDAS-EUROPE

Thank you for choosing Milesight UR32 industrial cellular router. ... C. When you log in with the default username and password, you will be asked to modify ...


File Info : application/pdf, 15 Pages, 2.42MB

PDF preview unavailable. Download the PDF instead.

Quick-Start-UR32
UR32
Quick Start Guide
Xiamen Milesight IoT Co., Ltd.

UR32 Quick Start Guide

Welcome
Thank you for choosing Milesight UR32 industrial cellular router.

This guide describes how to install the UR32 and how to log in the Web GUI to configure the device. Once you complete the installation, refer to the Milesight UR32 User Guide for instructions on how to perform configurations on the device.

Related Documents

This Start Guide only explains the installation of Milesight UR32 router. For more functionality and

advanced settings, please refer to the relevant documents as below.

Document

Description

UR32 Datasheet

Datasheet for UR32 industrial cellular router.

UR32 User Guide

Users could refer to the guide for instruction on how to log in the web GUI, and how to configure all the settings.

The related documents are available on Milesight website: https://www.milesight-iot.com

Declaration of Conformity
UR32 are in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.

© 2011-2021 Xiamen Milesight IoT Co., Ltd. All rights reserved. All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means without written authorization from Xiamen Milesight IoT Co., Ltd.
For assistance, please contact Milesight technical support: Email: iot.support@milesight.com Tel: 86-592-5085280 Fax: 86-592-5023065

Revision History
Date Apr. 26, 2019 May 11, 2020 Nov. 25, 2020

Doc Version V 1.0 V 1.1 V 2.0

Description Initial version Web interfaces upgrade Layout Replace

www.milesight-iot.com

2

UR32 Quick Start Guide
1. Packing List
Before you begin to install the UR32 router, please check the package contents to verify that you have received the items below.

1 × UR32

1 × Ethernet Cable

1 × Power Adapter

2 × Magnetic Cellular Antennas

1 × 6-Pin Pluggable Terminal

1 × DIN Rail Kit

4 × Setscrews

1 × Warranty Card

1 × Quick Start Guide

1 × Stubby Wi-Fi Antenna
(Wi-Fi Version Only)

1 × GPS Antenna (GPS Version Only)

2 × Stubby Cellular Antennas (Optional)

If any of the above items is missing or damaged, please contact your sales representative.

www.milesight-iot.com

3

2. Hardware Introduction 2.1 Overview
2.2 Dimensions (mm)

UR32 Quick Start Guide
1 Main Cellular Antenna Connector 2 GPS/WIFI Antenna Connector 3 AUX Cellular Antenna 4 LED Indicator Area
POWER: Power Indicator SYSTEM: Status Indicator SIM : Status Indicator
: Signal Strength Indicator 5 Serial Port & I/O 6 Ethernet LAN1/WAN Port 7 Ethernet LAN2 Port 8 Power Connector 9 SIM and Reset Button Holder

www.milesight-iot.com

4

2.3 Connectors

UR32 Quick Start Guide

PIN RS232 RS485* DI

DO

Description

1

---

---

--- OUT Digital Output

2

---

---

IN

---

Digital Input

3

GND

---

---

---

Ground

4

---

---

COM COM Common Ground

5

RXD

B

---

---

Receive Data

6

TXD

A

---

---

Transmit Data

78 *: Only for -485 model.

PIN

Description

7

Positive

8

Negative

2.4 LED Indicators

LED POWER SYSTEM
SIM
Signal Strength

Indication Power Status
System Status

Status Off On
Green Light
Red Light
Off

Green Light SIM Card Status

Orange Light

Signal 1/2/3

Off Green Light

Description The power is switched off The power is switched on Static: Start-up Blinking slowly: the system is running properly The system goes wrong SIM1 or SIM2 is registering or fails to register (or there are no SIM cards inserted) Blinking slowly: SIM1 has been registered and is ready for dial-up Blinking rapidly: SIM1 has been registered and is dialing up now Static: SIM1 has been registered and dialed up successfully Blinking slowly: SIM2 has been registered and is ready for dial-up Blinking rapidly: SIM2 has been registered and is dialing up now Static: SIM2 has been registered and dialed up successfully No signal Static/Off/Off: weak signals with 1-10 ASU (please check if the antenna is installed correctly, or move the antenna to a suitable location to get better signal)

www.milesight-iot.com

5

UR32 Quick Start Guide

Static/Static/Off: normal signals with 11-20 ASU (average signal strength) Static/Static/Static: strong signals with 21-31 ASU (signal is good)

2.5 Reset Button

Reset button is under the SIM slots.

Description Function
SYSTEM LED

Action

Blinking

Press and hold the reset button for more than 5 seconds.

Reset

Static Green  Rapidly Blinking

Release the button and wait.

Off  Blinking

The router is now reset to factory defaults.

2.6 Ethernet Port Indicator

Indicator Link Indicator (Orange)

Status On Blinking Off

Description Connected Transmitting data Disconnected

www.milesight-iot.com

6

UR32 Quick Start Guide

3. Hardware Installation
Environmental Requirements
- Power Input: 9-48 VDC - Power Consumption: Typical 1.9W (Max 2.4 W) - Operating Temperature: -40°C to 70°C (-40°F -158°F) - Relative Humidity: 0% to 95% (non-condensing) at 25°C/77°F

3.1 SIM Card/Micro SD Card Installation
A. Unscrew the cover of the SIM card then screw it up.

B. Put SIM card/Micro SD into the slot and take it off.

3.2 Antenna Installation
Rotate the antenna into the antenna connector accordingly. The external antenna should be installed vertically always on a site with a good signal.

3.4 Router Installation
The router can be placed on a desktop or mounted to a wall or a DIN rail.
3.4.1 Wall Mounting (Measured in mm)
Use 4 pcs of M3 × 6 flat head Phillips screws to fix the router on the wall.
Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.

www.milesight-iot.com

7

UR32 Quick Start Guide
3.4.2 DIN Rail Mounting (Measured in mm)
Use 2 pcs of M3 × 6 flat head Phillips screws to fix the DIN rail to the router, and then hang the DIN rail on the mounting bracket. It is necessary to choose a standard bracket.
Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.

www.milesight-iot.com

8

UR32 Quick Start Guide
4. Log in the Web GUI of Router
4.1 PC Configuration
Please connect PC to LAN port of UR32 router. PC can obtain an IP address, or you can configure a static IP address manually. The following steps are based on Windows 10 operating system for your reference. (Note: As remote access is disabled by default, you can't access to the router's Web GUI if you connect PC to WAN port of the router. But it will function properly if you enable it on Web GUI.)

 Click "Search Box" to search "Control Panel" on the Windows 10 taskbar.

 Click "Control Panel" to open it, and then click "View network status and tasks".

 Click "Ethernet" (May have different names).

 Click "Properties".

www.milesight-iot.com

9

UR32 Quick Start Guide

 Double Click "Internet Protocol Version 4 (TCP/IPv4)" to configure IP address and DNS server.

 Method 1: click "Obtain an IP address automatically";

(Note: Remember to click "OK" to finish configuration.)

Method 2: click "Use the following IP address" to assign a static IP manually within the same subnet of the router.

4.2 Log in the Router
If this is the first time you configure the router, please use the default settings below: IP Address: 192.168.1.1 Username: admin Password: password
A. Start a Web browser on your PC (Chrome is recommended), type in the IP address, and press Enter on your keyboard. B. Enter the username and password, click "Login".

www.milesight-iot.com

10

UR32 Quick Start Guide If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes. C. When you log in with the default username and password, you will be asked to modify the password. It's suggested that you change the password for the sake of security. Click "Cancel" button if you want to modify it later.
D. After you log in the Web GUI, you can view system information and perform configuration on the router.

www.milesight-iot.com

11

UR32 Quick Start Guide
5. Network Configuration
This chapter explains how to connect UR32 to network via WAN connection or cellular.
5.1 Ethernet WAN Configuration
A. Go to "Network > Interface > Port" to change LAN1 to WAN port.
B. Go to "Network > Interface > WAN" to configure WAN parameters. Take static IP configuration as an example. DHCP client and PPPoE type are optional according to your requirements.

Click "Save & Apply" button to make the changes take effect. C. Connect WAN port to another router or modem. D. Log in UR32 web GUI via WAN port IP address and go to "Status > Network" to check if status is "up".

www.milesight-iot.com

12

E. Go to "Network > Interface > Link Failover" to rise the WAN priority to 1.

UR32 Quick Start Guide

F. Open your preferred browser on PC, then type any available web address into address bar and see if it is able to visit Internet via UR32 router.
5.2 Cellular Connection Configuration
Take inserting SIM card into SIM1 slot as an example; please refer to the following detailed operations. A. Click "Network > Interface > Cellular > Cellular Setting" to configure the cellular info, like APN and network type. B. Click "Save" and "Apply" for configuration to take effect.

If you select "Auto", the router will obtain ISP information from SIM card to set APN, Username, and Password automatically. This option will only be taken effect when the SIM card is issued from a well-known ISP.
C. Go to "Network > Interface > Link Failover" to enable SIM1 and rise link priority of SIM1.

www.milesight-iot.com

13

UR32 Quick Start Guide

D. Click

to configure ICMP ping detection information.

E. Click "Status > Cellular" to view the status of the cellular connection. If it shows "Connected", it means SIM1 has dialed up successfully. On the other hand, you can check the status of SIM indicator. If it keeps on green light statically, it means SIM1 has dialed up successfully.

www.milesight-iot.com

14

UR32 Quick Start Guide F. Open your preferred browser on PC, then type any available web address into address bar and see if it is able to visit Internet via UR32 router.
[END]