Instructions for Ss brewtech models including: Jacketed Tank Kit, Tank Kit, Kit

FTSs Touch | Jacketed Tank Kit

Quick Start Guides - Ss Brewtech


File Info : application/pdf, 7 Pages, 1.37MB

PDF preview unavailable. Download the PDF instead.

2022 FTSs jacketed Unitank product guide final ?v=1666044126
ENGINEERING BETTER BEER
FTSs Touch Jacketed Tank

IN THE BOX

FTSs TOUCH | JACKETED TANK KIT

Check Valve Assembly

1.5" TC Sleeved Thermowell Adapter

Silicone Thermowell Cover

Hose Clamps

Hose Barbs 3/8" to 1/2" MPT

FTSs Touch Pump Harness Extension

Page 2

INTRODUCTION
SYSTEM OVERVIEW
The basic principle of the Fermentation Temperature Stabilization System (FTSs) is to pump chilled glycol through the jacket of your vessel when the temperature of your wort is greater than the controller set-point.
Warm Glycol Return
Low Pressure Closed Loop System
Cold Glycol Supply The FTSs is intended to be a low pressure closed loop system. Glycol pumped from the glycol chiller to the fermenter is then returned to the glycol chiller to be used again.
Page 3

ASSEMBLY INSTRUCTIONS
INSTALLING THE 1.5" TC SLEEVED THERMOWELL ADAPTER

Silicone TC Gasket

1.5" TC Clamp
1.5" Sleeved Thermowell Adapter Thermoprobe
Silicone Thermowell Cover

1.5" TC Sleeved Thermowell Adapter Location
Page 4

ASSEMBLY INSTRUCTIONS
Next submerge the pump(s) in the glycol solution, and top off the reservoir to about the 90% full level, making sure the evaporator coil is sufficiently submerged. This will allow glycol to flow through each fermenter's jacket without risking the chance of flowing back to the reservoir and overflowing the reservoir. Use the reservoir's sight glass as an indicator for glycol level. Reinstall the reservoir lid, and route the pump's lead wire(s) through the notch when the evaporator coil enters the reservoir.
Lid Silicone Tubing

Glycol Solution at 90% Full Level

Sight Glass

Evaporator Coil

Glycol Chiller

Pump

Page 5

ASSEMBLY INSTRUCTIONS (CONTINUED)
Supply Line- Extend a length of silicone tubing between the glycol chiller's outlet barb and the hose barb on the check valve at the tank (Fig. A). Be sure to install the tubing to the barb that corresponds to the pump's outlet. Secure each end of the tubing to the barbs using hose clamps. Return Line- Extend a length of silicone tubing between the hose barb on the tank's jacket outlet (Fig. B) and the glycol chiller's return barb. Secure each end of the tubing using hose clamps. Note: If additional tubing is required to span the distance between the chiller and fermenter, you can purchase more at www.ssbrewtech.com or pick some up at your local hardware store.

RETURN LINE FIG. B

3/8" Hose Barb to 1/2" MPT

3/8" Silicone Tube to Glycol Chiller

Unitank Fitting

3/8" Hose Clamp

SUPPLY LINE FIG. A

Check Valve Assembly

3/8" Hose Clamp

Unitank Fitting

Silicone Check Valve

3/8" Hose Barb to 1/2" MPT

3/8" Silicone Tube to Pump

*Note: Be sure to use Teflon tape on any threaded fittings